DESIGN FLOWS

The design flow for each type of question

Questions of one type always pass the same stations. See what must be checked, in what order, and which failure each station prevents, before working an example. Every station links to the steps of an example that do it.

Ordinary bolted connection

The force passes from one plate through the bolts to the other plate. Every station on the way can fail, so demand and capacity are compared station by station; the weakest one decides the connection.

  1. 1Design force

    Fix the force the connection must pass on; unfactored loads are multiplied by 1.4 and 1.6 first.

    F=1.4Gk+1.6QkF=1.4G_k+1.6Q_k

    Example: Two M20 bolts connecting an angle: link the checks (Bolted Angle), Step 1

  2. 2Force on one bolt

    Shared equally when the force passes through the centre of the bolt group; with eccentricity, add the shear caused by the moment.

    Fs=F/nF_s=F/n

    Example: Two M20 bolts connecting an angle: link the checks (Bolted Angle), Step 2

  3. 3Bolt in shear

    Stops the bolt being cut where the plates meet. Double shear has two shear planes, so the capacity is doubled.

    Ps=psAsP_s=p_sA_s

    Table: Data Page 4 · Bolt tablesExample: Two M20 bolts connecting an angle: link the checks (Bolted Angle), Step 3–4

  4. 4Bearing on the bolt

    Stops the bolt shank being crushed by the hole wall. Use the thinner side.

    Pbb=dtppbbP_{bb}=dt_pp_{bb}

    Table: Data Page 4 · Bolt tablesExample: Two M20 bolts connecting an angle: link the checks (Bolted Angle), Step 5

  5. 5Bearing on the plate

    Stops the hole wall being crushed, or the bolt tearing out the end of the plate or the steel between holes. Take the smallest of four values.

    Pbs=min⁡(kbsdtppbs, 0.5kbsetppbs, 1.5letpUs, 2dtpUb)P_{bs}=\min(k_{bs}dt_pp_{bs},\ 0.5k_{bs}et_pp_{bs},\ 1.5l_et_pU_s,\ 2dt_pU_b)
    Pbs=min⁡(kbsdtppbs, 0.5kbsetppbs, 1.5letpUs, 2dtpUb)\begin{aligned}P_{bs}&=\min(k_{bs}dt_pp_{bs},\\&\quad \ 0.5k_{bs}et_pp_{bs},\\&\quad \ 1.5l_et_pU_s,\ 2dt_pU_b)\end{aligned}

    Table: Data Page 4 · Bearing of connected partExample: Two M20 bolts connecting an angle: link the checks (Bolted Angle), Step 6–8

  6. 6Plate or angle in tension

    Stops the plate breaking through the holes. Use the effective area with the holes taken out; an angle connected by one leg is reduced further.

    Pt=pyAeP_t=p_yA_e

    Table: Data Page 2 · Tension membersExample: Two M20 bolts connecting an angle: link the checks (Bolted Angle), Step 9–11

  7. 7Hole spacing and end distance

    After the capacities pass, confirm the hole layout meets the minimum and maximum distances.

    Example: 750 kN double-cover splice: separate capacity and spacing (Double-cover Splice), Step 8–10

Examples of this type: Two M20 bolts connecting an angle: link the checks (Bolted Angle) · 750 kN double-cover splice: separate capacity and spacing (Double-cover Splice) · Q3: combine shear at each bolt in an eccentric in-plane group (In-plane Eccentric Bolts) · Q4: bracket-bolt shear, tension and interaction (Shear–Tension Interaction) · 960 kN test question: four checks (Four Checks) · M27 plate bearing: calculate all four bounds (Four Bearing Limits)

Fillet-welded connection

The force passes from one piece to the other through the throat of the weld. First find what one millimetre of weld can carry, then how much length is needed and whether the force is shared equally between the welds.

  1. 1Design force

    Fix the force the welds must pass on; factor the loads first if they are unfactored.

    F=1.4Gk+1.6QkF=1.4G_k+1.6Q_k

    Example: Single welded angle: check the member, then allocate welds (Welded Angle), Step 1

  2. 2Throat and capacity per millimetre

    A weld shears through its thinnest part, the throat, so the throat is used, not the leg.

    a=0.7s,qw=apwa=0.7s,\qquad q_w=ap_w

    Table: Data Page 3 · Design strength of fillet weld pwp_wExample: 850 kN lap weld: effective and provided lengths (Lap Weld), Step 1–2

  3. 3Effective length needed

    Demand divided by the capacity per millimetre gives the length of weld needed.

    Ltotal=F/qwL_{total}=F/q_w

    Example: 850 kN lap weld: effective and provided lengths (Lap Weld), Step 3–4

  4. 4Actual length

    A length at each end of a weld is not counted, so two leg sizes are added to the effective length.

    Lactual≥Leff+2sL_{actual}\ge L_{eff}+2s

    Example: 850 kN lap weld: effective and provided lengths (Lap Weld), Step 5–6

  5. 5When the force is not shared equally

    The pull in an angle is not midway between its two welds; the weld nearer the centroid takes more. An eccentric load on a weld group adds the shear caused by the moment, summed point by point.

    FXcX=FYcYF_Xc_X=F_Yc_Y

    Table: Data Page 12 · Unequal AnglesExample: Single welded angle: check the member, then allocate welds (Welded Angle), Step 3–6

  6. 6The connected steel

    After the welds pass, confirm the plate or angle itself does not break in tension.

    Pt=pyAgP_t=p_yA_g

    Table: Data Page 1 · Design strength pyp_yExample: 850 kN lap weld: effective and provided lengths (Lap Weld), Step 8–9

Examples of this type: 850 kN lap weld: effective and provided lengths (Lap Weld) · Single welded angle: check the member, then allocate welds (Welded Angle) · 65×50×8 angle: centroid and unequal weld lengths (Unequal Weld Lengths) · 350 kN double angles: total areas and side distribution (Double Angles) · Eccentric weld Q6: from geometry to resultant (Eccentric Weld Group) · Q7: separate flange and web weld roles (Bracket Flange and Web Welds)

Laterally restrained beam

The floor load becomes a line load on the beam, then shear and moment inside it. The beam must be strong enough (in shear and in bending) and must not sag too much.

  1. 1Loads

    Area load times tributary width gives the line load. Strength uses the factored load; deflection uses the unfactored imposed load. Keep the two sets apart.

    w=1.4gk+1.6qkw=1.4g_k+1.6q_k

    Example: B1 floor beam: from slab load to strength and deflection (Complete Beam Walkthrough), Step 1–5

  2. 2Reactions, shear and moment

    Find the largest shear and moment in the beam: these are the demands.

    V=wL/2,M=wL2/8V=wL/2,\qquad M=wL^2/8

    Example: B1 floor beam: from slab load to strength and deflection (Complete Beam Walkthrough), Step 6–7

  3. 3Design strength and section classification

    Take pyp_y from grade and flange thickness; then see whether the flange or web is thin enough to wrinkle first. Only Class 1 or 2 may use the plastic modulus.

    ε=275/py\varepsilon=\sqrt{275/p_y}

    Table: Data Page 1 · Table 7.1 Limiting width-to-thickness ratiosExample: B1 floor beam: from slab load to strength and deflection (Complete Beam Walkthrough), Step 8

  4. 4Shear

    Stops the web shearing near the support. When the shear is not more than 0.6 of the capacity, the moment capacity needs no reduction.

    Vc=pyAv/3V_c=p_yA_v/\sqrt3

    Table: Data Page 9 · Universal Beams — DimensionsExample: B1 floor beam: from slab load to strength and deflection (Complete Beam Walkthrough), Step 9–11

  5. 5Bending

    Stops the section yielding where the moment is largest.

    Mc=min⁡(pySx, 1.2pyZx)M_c=\min(p_yS_x,\ 1.2p_yZ_x)

    Table: Data Page 10 · Universal Beams — PropertiesExample: B1 floor beam: from slab load to strength and deflection (Complete Beam Walkthrough), Step 12–13

  6. 6Deflection

    Stops the beam sagging so much that finishes crack. Use the unfactored imposed load and turn the limit into mm.

    Δ=5wL4384EI≤L/360\Delta=\frac{5wL^4}{384EI}\le L/360

    Table: Data Page 2 · Table 5.1 Deflection limitsExample: B1 floor beam: from slab load to strength and deflection (Complete Beam Walkthrough), Step 14–16

  7. 7The web at a support

    The reaction presses on a short length of web. The web may be crushed or may buckle like a short column: check both.

    Pbw=(b1+nk)tpywP_{bw}=(b_1+nk)tp_{yw}

    Example: Local web checks: both modes must pass (Web Bearing and Buckling), Step 2–7

Examples of this type: B1 floor beam: from slab load to strength and deflection (Complete Beam Walkthrough) · B2: the internal beam in the same floor (Interior Beam) · B3: a support reaction loads the next beam (Reaction Transfer) · B3 support: local web bearing and buckling (B3 Local Web Checks) · Initial section selection from load demand (Trial Section Selection) · Local web checks: both modes must pass (Web Bearing and Buckling) · 6 m revision beam: coexisting shear and deflection (Coexistent Shear) · 8 m revision beam: resistance and deformation again (Beam Check Practice)

Unrestrained beam (lateral-torsional buckling)

If nothing holds the compression flange sideways, it moves sideways and twists the whole beam. The moment capacity is then smaller than that of the section alone and has to be calculated separately.

  1. 1Finish the beam checks first

    Loads, shear, moment, classification and deflection are done as for a restrained beam.

    Example: B3 with midspan restraint: complete the LTB procedure (Restrained Segments), Step 1

  2. 2Length without restraint

    The longer the distance between two lateral restraints, the more easily the beam buckles sideways.

    λ=LE/ry\lambda=L_E/r_y

    Table: Data Page 10 · Universal Beams — PropertiesExample: Unrestrained B2: a strong section can still buckle (Unrestrained Beam), Step 1

  3. 3Equivalent slenderness

    Allows for how well the section resists twisting, giving the λLT\lambda_{LT} used to enter the table.

    λLT=uvλβw\lambda_{LT}=uv\lambda\sqrt{\beta_w}

    Table: Data Page 10 · Universal Beams — PropertiesExample: Unrestrained B2: a strong section can still buckle (Unrestrained Beam), Step 2

  4. 4Bending strength and buckling resistance

    The larger λLT\lambda_{LT}, the smaller the bending strength pbp_b that can be used. Usually interpolated between two rows.

    Mb=pbSxM_b=p_bS_x

    Table: Data Page 5 · Table 8.3aExample: Unrestrained B2: a strong section can still buckle (Unrestrained Beam), Step 3

  5. 5Compare

    When the moment is not at its maximum along the whole length, mLTm_{LT} reduces the demand before comparing with MbM_b.

    mLTMx≤Mbm_{LT}M_x\le M_b

    Table: Data Page 6 · Table 8.4aExample: Unrestrained B2: a strong section can still buckle (Unrestrained Beam), Step 4–5

Examples of this type: Unrestrained B2: a strong section can still buckle (Unrestrained Beam) · B3 with midspan restraint: complete the LTB procedure (Restrained Segments) · Overhanging beam Q5: separate load patterns and check AB (Overhanging Beam)

Column: axial force with moments

A column is mainly in compression, and a slender one bows sideways before it is crushed. When a beam reaction is off the centre of the column, the column also carries moment; the fractions used up by axial force and by moment are then added.

  1. 1Axial force and moments

    Add the forces from every floor and beam. In simple construction a beam reaction acts 100 mm outside the column face, and the eccentricity causes moment.

    M=ReM=Re

    Example: Simple-construction column: how beam reactions produce moments (Beam Reactions into Columns), Step 1–4

  2. 2Effective length and slenderness

    Turn the actual length into an effective length by the end conditions; do each axis separately, the larger slenderness buckles more easily.

    λ=LE/r\lambda=L_E/r

    Table: Data Page 11 · Universal Columns — PropertiesExample: Pure-compression UC column: from two-axis lookup to capacity (Axial Compression), Step 1–3

  3. 3Compressive strength and buckling resistance

    Choose the buckling curve, then read pcp_c from λ\lambda and pyp_y. Take the smaller capacity of the two axes.

    Pc=AgpcP_c=A_gp_c

    Table: Data Page 7 · Table 8.7 Buckling curvesExample: Pure-compression UC column: from two-axis lookup to capacity (Axial Compression), Step 4–5

  4. 4Cross-section check

    Stops the most heavily loaded section yielding: add the fractions used by the axial force and by the moments about both axes.

    FcAgpy+MxMcx+MyMcy≤1\frac{F_c}{A_gp_y}+\frac{M_x}{M_{cx}}+\frac{M_y}{M_{cy}}\le1

    Table: Data Page 1 · Design strength pyp_yExample: Example 5: biaxial checks for a non-sway-frame column (Biaxial Column), Step 2–5

  5. 5Member check 1: buckling

    Stops the whole column bowing sideways. The axial term uses the buckling resistance PcP_c and the moment terms are multiplied by m factors.

    FcPc+mxMxpyZx+myMypyZy≤1\frac{F_c}{P_c}+\frac{m_xM_x}{p_yZ_x}+\frac{m_yM_y}{p_yZ_y}\le1

    Table: Data Page 7 · Table 8.9Example: Example 5: biaxial checks for a non-sway-frame column (Biaxial Column), Step 6–10

  6. 6Member check 2: lateral-torsional buckling

    Moment about the major axis may make the column buckle like a beam, so that term is divided by MbM_b.

    FcPc+mLTMLTMb+myMypyZy≤1\frac{F_c}{P_c}+\frac{m_{LT}M_{LT}}{M_b}+\frac{m_yM_y}{p_yZ_y}\le1

    Table: Data Page 5 · Table 8.3aExample: Example 5: biaxial checks for a non-sway-frame column (Biaxial Column), Step 11

Examples of this type: Pure-compression UC column: from two-axis lookup to capacity (Axial Compression) · Example 5: biaxial checks for a non-sway-frame column (Biaxial Column) · Column Q2: section and member checks for 305×305×118 UC (Column Q2) · Column Q3: biaxial bending of 305×305×198 UC (Column Q3) · Q5: utilisation slightly above 1, judged marginally OK by the lecturer (Marginal Utilization) · Simple-construction column: how beam reactions produce moments (Beam Reactions into Columns) · Column interaction revision: where each ratio comes from (Column Interaction Review)