Worked Example

Local web checks: both modes must pass (Web Bearing and Buckling)

Task: Understand why local buckling can govern despite a generous bearing margin.

Original question · Lecture notes Chapter 3, p. 18 (Example 1)
Original question with the given values boxed
Yellow boxes: values the question gives, the same values marked yellow in the Given table below.

The question in short: A 533×210×82 UB in S355 has a support reaction of 292.3 kN, which enters the 9.6 mm thick web through a bearing 160 mm wide. Decide whether the web is crushed or buckles sideways.

What differs from the previous example of this type: The previous example only chose a trial section. This one takes that section and checks local bearing and buckling of the web at the support, where buckling only just passes.

GivenValue and Unit
Applied forceSupport reaction 292.3 kN (from the shear diagram in the question)
BearingStiff bearing b1=160 mm\htmlClass{given}{b_1=160\ \mathrm{mm}}; ae=80 mm\htmlClass{given}{a_e=80\ \mathrm{mm}}; be = 0
Section533×210×82 UB (chosen in the previous example), S355; d=476.5\htmlClass{read}{d=476.5}, t=9.6\htmlClass{read}{t=9.6}, T=13.2\htmlClass{read}{T=13.2}, r=12.7 mm\htmlClass{read}{r=12.7\ \mathrm{mm}}; pyw=355 N/mm2\htmlClass{read}{p_{yw}=355\ \mathrm{N/mm^{2}}}

Yellow: values given in the question. The same values are marked where they are substituted in the steps below.
Orange box: values read directly from the Data File, the same values boxed orange in the lookup screenshots. A value interpolated between two table rows is a calculation, so it has no box.

Data file lookup · Data Page 9 · Universal Beams — Dimensions
533×210×82 UB: t = 9.6 mm, T = 13.2 mm, r = 12.7 mm, d = 476.5 mm; k = T + r = 25.9 mm.
533×210×82 UB: t=9.6 mmt=9.6\ \mathrm{mm}, T=13.2 mmT=13.2\ \mathrm{mm}, r=12.7 mmr=12.7\ \mathrm{mm}, d=476.5 mmd=476.5\ \mathrm{mm}; k=T+r=25.9 mmk=T+r=25.9\ \mathrm{mm}.Yellow: given parameter, row or columnOrange: value read from the table, boxed orange in the text too
Data file lookup · Data Page 1 · Design strength pyp_y
A rolled section is classified by its thickest element: flange T = 13.2 mm, so the T ≤ 16 mm row, S355 column gives py = 355 N/mm²; the web checks use this value as pyw.
A rolled section is classified by its thickest element: flange T=13.2 mmT=13.2\ \mathrm{mm}, so the T≤16 mmT\le16\ \mathrm{mm} row, S355 column gives py=355 N/mm2p_y=355\ \mathrm{N/mm^{2}}; the web checks use this value as pywp_{yw}. How the grade and thickness choose this row →Yellow: given parameter, row or columnOrange: value read from the table, boxed orange in the text too

Solution Route: Identify the same force location→choose the end-distance branch→calculate both resistances→compare with the same demand.

Interactive 3D model · drag to turn

This browser cannot show the 3D model.

The beam end sits on a 160 mm stiff bearing. The reaction spreads up through the flange and root radius, so at the root of the web it acts over b1+nkb_1+nk (red strip). Web bearing checks the web over this length; web buckling treats the web as a strut of height dd.Yellow: values given in the question; orange box: values read from the Data File; white: calculated results; red arrows: forces.
Load path · the stations the force passes through, in order

The reaction enters the web from the bearing plate through the bottom flange. The web is thin, so two local failures are checked; this is separate from the shear capacity of the whole beam.

  1. Support reaction
    292.3 kN
    Step 1
  2. Bearing plate and flange
    The force spreads upwards over a length b1+nkb_1+nk
    Step 2–3
  3. Web bearing
    Demand 292.3 kNCapacity 721.8144 kN
    Utilisation 0.40
    Step 3
  4. Web buckling
    Demand 292.3 kNCapacity 297.5 kN
    Utilisation 0.98 · closest to the limit
    Step 4–6
Red frame: the station closest to its limit. Each station links to the step that calculates it. Press “Show on the 3D model” to light up that part of the model above; press again to clear.
  1. Step 1 · Identify local loading

    Why this step: The reaction is not shared by the whole web. It is concentrated in a short length above the support, and that short length may fail first.

    The support transmits 292.3 kN through a 160 mm contact width into the web, distinct from overall AvA_v shear resistance VcV_c.

    ▶ The lecturer on this part: 17 October 00:29:21

  2. Step 2 · Select nn for this end condition

    Why this step: The force spreads out as it passes through the flange and root fillet. kk and nn are used to find how long a piece of web it presses on when it arrives.

    be = 0, so n=2+0.6n=2+0.6be/k = 2; k=T+r=13.2+12.7=25.9 mmk=T+r=13.2+12.7=25.9\ \mathrm{mm}, with TT and rr read from the section table. These are geometric and formula conditions, not results of moment equilibrium.

    New symbols in this step
    • kk, nn: Rolled-section junction length in mm; dimensionless end-condition factor
    k=T+r=13.2+12.7=25.9 mmn=2+0.6be/k=2+0.6(0)/25.9=2\begin{aligned}k&=T+r={\htmlClass{read}{13.2}}+{\htmlClass{read}{12.7}}=25.9\ \mathrm{mm}\\n&=2+0.6b_e/k=2+0.6({\htmlClass{given}{0}})/25.9=2\end{aligned}
    k=T+r=13.2+12.7=25.9 mmn=2+0.6be/k=2+0.6(0)/25.9=2\begin{aligned}k&=T+r={\htmlClass{read}{13.2}}+{\htmlClass{read}{12.7}}=25.9\ \mathrm{mm}\\n&=2+0.6b_e/k\\&=2+0.6({\htmlClass{given}{0}})/25.9\\&=2\end{aligned}
  3. Step 3 · Web bearing

    Why this step: This guards against the web above the support yielding and being squashed. The capacity is the most force this length of web can carry.

    Effective bearing length is b1+nkb_1+nk. Multiply by web thickness and strength, then convert N to kN.

    New symbols in this step
    • b1b_1, aea_e: Bearing contact width and course end-distance parameter; mm
    • PbwP_{bw}, PxP_x: Local bearing and buckling resistances; kN
    Pbw=(b1+nk)tpyw=(160+2(25.9))(9.6)(355)/1000=721.8144 kNP_{bw}=(b_1+nk)tp_{yw}=({\htmlClass{given}{160}}+2(25.9))({\htmlClass{read}{9.6}})({\htmlClass{read}{355}})/1000=721.8144\ \mathrm{kN}
    Pbw=(b1+nk)tpyw=(160+2(25.9))(9.6)(355)/1000=721.8144 kN\begin{aligned}P_{bw}&=(b_1+nk)tp_{yw}\\&=({\htmlClass{given}{160}}+2(25.9))({\htmlClass{read}{9.6}})({\htmlClass{read}{355}})/1000\\&=721.8144\ \mathrm{kN}\end{aligned}

    Where the numbers come from: 25.925.9 from Step 2.

    Units: mm times mm gives mm², times N/mm² gives N, and dividing by 1000 gives kN, because 1 kN is 1000 N.

    Load path · How the reaction enters the web
    R = 292.3 kNb1​ = 160ae​ = 80b1​ + nkd = 476.5k = 25.9Sketch, not to scaleb1​ + nk = 160 + 2(25.9) = 211.8 mmBearing: only this length of web shares the reactionBuckling: this strip of web acts like a strut (red dashed lines)Bearing: Pbw​ = 721.8 kN, utilisation 0.405Buckling: Px​ = 297.5 kN, utilisation 0.983 ← closer to the limit
    The reaction enters the bottom flange from the bearing plate and spreads upwards through the flange and root radius; at the root of the web the loaded length has grown from b1b_1 to b1+nkb_1+nk (yellow). Web bearing asks whether the web over this length crushes; web buckling treats the same strip of web as a strut of height dd.
  4. Step 4 · Select the buckling branch

    Why this step: The support is close to the beam end, leaving little web beyond it to share the force, so the reduced buckling formula applies.

    The lecturer uses the near-end branch with ae<0.7da_e<0.7d. Compare the lengths first; do not skip this prerequisite.

    New symbols in this step
    • dd, tt: Effective web depth and thickness; mm
    ae=80<0.7d=0.7(476.5)=333.55 mma_e={\htmlClass{given}{80}}<0.7d=0.7({\htmlClass{read}{476.5}})=333.55\ \mathrm{mm}
    ae=80<0.7d=0.7(476.5)=333.55 mm\begin{aligned}a_e&={\htmlClass{given}{80}}\\&<0.7d\\&=0.7({\htmlClass{read}{476.5}})\\&=333.55\ \mathrm{mm}\end{aligned}

    ▶ The lecturer on this part: 17 October 00:49:52

  5. Step 5 · Write the complete course buckling expression

    Why this step: A taller, thinner web bulges sideways more easily. The formula starts from the bearing capacity and adjusts it for the web's depth and thickness.

    The first ratio addresses end distance; the second includes web slenderness and local geometry. Multiply by bearing resistance last. Both ratios are dimensionless.

    Px=ae+0.7d1.4d25εt(b1+nk)dPbwP_x=\frac{a_e+0.7d}{1.4d}\frac{25\varepsilon t}{\sqrt{(b_1+nk)d}}P_{bw}
  6. Step 6 · Substitute term by term

    Why this step: Substituting gives the force the web can take before it bulges sideways. It is much smaller than the bearing capacity, showing that a thin web is more at risk from buckling.

    Using course-rounded ε=0.88\varepsilon=0.88 and Pbw=721.8 kNP_{bw}=721.8\ \mathrm{kN} reproduces approximately 297.5 kN.

    New symbols in this step
    • pywp_{yw}, ε\varepsilon: Web design yield strength N/mm²; dimensionless classification/buckling strength factor
    ε=275/pyw=275/355≈0.88Px=80+0.7(476.5)1.4(476.5)25(0.88)(9.6)(160+2(25.9))(476.5)(721.8)≈297.5 kN\begin{aligned}\varepsilon&=\sqrt{275/p_{yw}}=\sqrt{275/{\htmlClass{read}{355}}}\approx0.88\\P_x&=\frac{{\htmlClass{given}{80}}+0.7({\htmlClass{read}{476.5}})}{1.4({\htmlClass{read}{476.5}})}\frac{25(0.88)({\htmlClass{read}{9.6}})}{\sqrt{({\htmlClass{given}{160}}+2(25.9))({\htmlClass{read}{476.5}})}}(721.8)\approx297.5\ \mathrm{kN}\end{aligned}
    ε=275/pyw=275/355≈0.88Px=80+0.7(476.5)1.4(476.5)25(0.88)(9.6)(160+2(25.9))(476.5)(721.8)≈297.5 kN\begin{aligned}\varepsilon&=\sqrt{275/p_{yw}}=\sqrt{275/{\htmlClass{read}{355}}}\approx0.88\\P_x&=\frac{{\htmlClass{given}{80}}+0.7({\htmlClass{read}{476.5}})}{1.4({\htmlClass{read}{476.5}})}\frac{25(0.88)({\htmlClass{read}{9.6}})}{\sqrt{({\htmlClass{given}{160}}+2(25.9))({\htmlClass{read}{476.5}})}}(721.8)\\&\approx297.5\ \mathrm{kN}\end{aligned}

    Where the numbers come from: 25.925.9 from Step 2.

  7. Step 7 · Compare both failure modes

    Why this step: A web that is not crushed can still buckle. The buckling utilisation is close to one, so a slightly larger reaction would make it fail.

    Compare each capacity with the same reaction RR. The smaller buckling resistance is close to governing.

    ηbearing=F/Pbw=292.3/721.8≈0.405ηbuckling=F/Px=292.3/297.5≈0.983\begin{aligned}\eta_{bearing}&=F/P_{bw}={\htmlClass{given}{292.3}}/721.8\approx0.405\\\eta_{buckling}&=F/P_x={\htmlClass{given}{292.3}}/297.5\approx0.983\end{aligned}
    ηbearing=F/Pbw=292.3/721.8≈0.405ηbuckling=F/Px=292.3/297.5≈0.983\begin{aligned}\eta_{bearing}&=F/P_{bw}\\&={\htmlClass{given}{292.3}}/721.8\\&\approx0.405\\\eta_{buckling}&=F/P_x\\&={\htmlClass{given}{292.3}}/297.5\\&\approx0.983\end{aligned}

    Where the numbers come from: 297.5297.5 from Step 6.

Conclusion

Bearing and local buckling both pass, but buckling margin is small. A different support position or contact length requires reselecting the expression branch.

All the symbols of this example

SymbolsMeaning and Units
b1b_1, aea_eBearing contact width and course end-distance parameter; mm
dd, ttEffective web depth and thickness; mm
kk, nnRolled-section junction length in mm; dimensionless end-condition factor
pywp_{yw}, ε\varepsilonWeb design yield strength N/mm²; dimensionless classification/buckling strength factor
PbwP_{bw}, PxP_xLocal bearing and buckling resistances; kN

Video positions: 17 October 00:30:00 · 17 October 00:50:00

↑ Top