Single welded angle: check the member, then allocate welds (Welded Angle)
Task: Understand that angle resistance and weld transfer are separate checks, and allocate both weld lengths by centroid equilibrium.
Go straight to Step 1 ↓Design flow for this type of question: Fillet-welded connection →

The question in short: A 75×50×6 angle carries a tension from a dead load of 95 kN and an imposed load of 40 kN, and is fixed to a connecting plate with 4 mm fillet welds. Check that the angle itself is not pulled apart, then decide how long the weld on each side must be.
What differs from the previous example of this type: The previous example was a symmetric plate with four equal welds. Here the member is an angle whose centroid is off-centre, so the two side welds differ in length, and the design force must first be found using load factors.
| Given | Value and Unit |
|---|---|
| Section and loading | 75×50×6 angle, S355; DL 95, LL 40 kN |
| Dimensions on the figure | Leg centreline lengths 72 and 47 mm; centroid 24.4 mm from side and 50.6 mm from side |
| Welds | Try a 4 mm fillet weld; (the question does not state the electrode; the lecturer takes class 42) |
Yellow: values given in the question. The same values are marked where they are substituted in the steps below.
Orange box: values read directly from the Data File, the same values boxed orange in the lookup screenshots. A value interpolated between two table rows is a calculation, so it has no box.

Solution Route: Design force→single-leg welded-angle resistance→total weld length→two-side equilibrium→actual lengths and selections.
This browser cannot show the 3D model.
The tension acts along the centroid line of the angle and passes through the two longitudinal welds into the plate. The centroid is off-centre, so the two welds share the force unequally.
- Design tension
- Angle in tensionDemand 197 kNCapacity 223.44 kNUtilisation 0.88
- Weld on side (nearer the centroid)Needs 197.87 mmUse 200 mm
- Weld on side (farther away)Needs 99.56 mmUse 100 mm
- Connecting plateReceives the whole 197 kN from the two welds
- Step 1 · Design force
Why this step: The loads given have not yet been multiplied by load factors. Factoring them gives a larger design force, which every later capacity is compared with, so a safety margin is built in.
Use the lecturer's load combination.
New symbols in this step- , : Applied force; kN
- , : Unfactored dead and imposed loads; kN
- Step 2 · Angle resistance
Why this step: First confirm the angle itself will not be pulled apart. Only one leg is welded to the plate and the other leg carries less, so the area of the unconnected leg is discounted.
The figure already gives the leg lengths along the thickness centreline, 72 and 47 mm; multiplied by the 6 mm thickness they give the two leg areas. A welded joint has no holes, so the effective area is the gross area . A welded single angle uses the 0.3 reduction for the unconnected leg, not the 0.5 of the bolted example.
New symbols in this step- , : Eccentricity and weld-group corner radius; mm
- , , : Connected/outstanding angle-leg areas mm²; tension resistance kN
Units: The discounted area in mm² times in N/mm² gives N. Dividing by 1000 turns N into kN so it can be compared with the design force.
Data file lookup · Data Page 2 · Tension members
For a single angle welded through one leg, .Yellow: given parameter, row or columnOrange: value read from the table, boxed orange in the text too Data file lookup · Data Page 1 · Design strength
Angle 6 mm thick: the row, S355 column gives . How the grade and thickness choose this row →Yellow: given parameter, row or columnOrange: value read from the table, boxed orange in the text too - Step 3 · Weld-length demand
Why this step: All the tension in the angle reaches the connecting plate through the welds. Finding what the throat of each millimetre of weld can carry shows how much weld is needed to avoid shearing.
After the member passes, design transfer of 197 kN to the connecting plate.
New symbols in this step- , : Weld design strength N/mm²; resistance per millimetre kN/mm
Units: Leg size in mm times 0.7 gives the throat in mm; times in N/mm² gives N per mm. Dividing by 1000 turns it into kN per mm.
Data file lookup · Data Page 3 · Design strength of fillet weld
For S355 steel with class 42 electrodes the fillet weld design strength is .Yellow: given parameter, row or columnOrange: value read from the table, boxed orange in the text too - Step 4 · Total effective weld length
Why this step: The result is the least load-carrying length for both sides together. It does not yet say which side is longer and which is shorter.
Initially assume the two longitudinal welds share axial force.
Where the numbers come from: from Step 1.
- Step 5 · Allocate by centroid position
Why this step: The pull in the angle acts along its centroid line. The side nearer the centroid takes more force and so gets the longer weld; then the two sides balance and the joint is not twisted.
Pair the lever arms through moment equilibrium. If is 24.4 mm from the centroid and 50.6 mm, .
New symbols in this step- , : Distances from the two welds to the angle centroid; mm
Where the numbers come from: from Step 4.
Load path · How the two welds share the tensionThe tension acts on the centroid line. The moments of the two weld forces about the centroid must cancel, so side , nearer the centroid, carries more force and needs the longer weld. Lengths shown are effective lengths, before adding . - Step 6 · Add end allowances
Why this step: The start and end of each weld are not counted as carrying load, so both sides are lengthened and then rounded up to lengths that are easy to measure on site.
Add to each side, then select 200 and 100 mm.
New symbols in this step- , : Leg size and effective throat; mm, with in this course
Unequal lengths place the resultant through the centroid, avoiding additional eccentricity . Confirm both angle tension and weld resistance.
All the symbols of this example
| Symbols | Meaning and Units |
|---|---|
| , | Leg size and effective throat; mm, with in this course |
| , | Weld design strength N/mm²; resistance per millimetre kN/mm |
| , | Applied force; kN |
| , | Eccentricity and weld-group corner radius; mm |
| , , | Connected/outstanding angle-leg areas mm²; tension resistance kN |
| , | Unfactored dead and imposed loads; kN |
| , | Distances from the two welds to the angle centroid; mm |
Video positions: 3 October Recording A 00:30:00 · 3 October Recording A 00:35:00