The design flow for each type of question
Questions of one type always pass the same stations. See what must be checked, in what order, and which failure each station prevents, before working an example. Every station links to the steps of an example that do it.
Ordinary bolted connection
The force passes from one plate through the bolts to the other plate. Every station on the way can fail, so demand and capacity are compared station by station; the weakest one decides the connection.
- 1Design force
Fix the force the connection must pass on; unfactored loads are multiplied by 1.4 and 1.6 first.
- 2Force on one bolt
Shared equally when the force passes through the centre of the bolt group; with eccentricity, add the shear caused by the moment.
- 3Bolt in shear
Stops the bolt being cut where the plates meet. Double shear has two shear planes, so the capacity is doubled.
- 4Bearing on the bolt
Stops the bolt shank being crushed by the hole wall. Use the thinner side.
- 5Bearing on the plate
Stops the hole wall being crushed, or the bolt tearing out the end of the plate or the steel between holes. Take the smallest of four values.
- 6Plate or angle in tension
Stops the plate breaking through the holes. Use the effective area with the holes taken out; an angle connected by one leg is reduced further.
- 7Hole spacing and end distance
After the capacities pass, confirm the hole layout meets the minimum and maximum distances.
Examples of this type: Two M20 bolts connecting an angle: link the checks (Bolted Angle) · 750 kN double-cover splice: separate capacity and spacing (Double-cover Splice) · Q3: combine shear at each bolt in an eccentric in-plane group (In-plane Eccentric Bolts) · Q4: bracket-bolt shear, tension and interaction (Shear–Tension Interaction) · 960 kN test question: four checks (Four Checks) · M27 plate bearing: calculate all four bounds (Four Bearing Limits)
Fillet-welded connection
The force passes from one piece to the other through the throat of the weld. First find what one millimetre of weld can carry, then how much length is needed and whether the force is shared equally between the welds.
- 1Design force
Fix the force the welds must pass on; factor the loads first if they are unfactored.
- 2Throat and capacity per millimetre
A weld shears through its thinnest part, the throat, so the throat is used, not the leg.
- 3Effective length needed
Demand divided by the capacity per millimetre gives the length of weld needed.
- 4Actual length
A length at each end of a weld is not counted, so two leg sizes are added to the effective length.
- 5When the force is not shared equally
The pull in an angle is not midway between its two welds; the weld nearer the centroid takes more. An eccentric load on a weld group adds the shear caused by the moment, summed point by point.
- 6The connected steel
After the welds pass, confirm the plate or angle itself does not break in tension.
Examples of this type: 850 kN lap weld: effective and provided lengths (Lap Weld) · Single welded angle: check the member, then allocate welds (Welded Angle) · 65×50×8 angle: centroid and unequal weld lengths (Unequal Weld Lengths) · 350 kN double angles: total areas and side distribution (Double Angles) · Eccentric weld Q6: from geometry to resultant (Eccentric Weld Group) · Q7: separate flange and web weld roles (Bracket Flange and Web Welds)
Laterally restrained beam
The floor load becomes a line load on the beam, then shear and moment inside it. The beam must be strong enough (in shear and in bending) and must not sag too much.
- 1Loads
Area load times tributary width gives the line load. Strength uses the factored load; deflection uses the unfactored imposed load. Keep the two sets apart.
- 2Reactions, shear and moment
Find the largest shear and moment in the beam: these are the demands.
- 3Design strength and section classification
Take from grade and flange thickness; then see whether the flange or web is thin enough to wrinkle first. Only Class 1 or 2 may use the plastic modulus.
- 4Shear
Stops the web shearing near the support. When the shear is not more than 0.6 of the capacity, the moment capacity needs no reduction.
- 5Bending
Stops the section yielding where the moment is largest.
- 6Deflection
Stops the beam sagging so much that finishes crack. Use the unfactored imposed load and turn the limit into mm.
- 7The web at a support
The reaction presses on a short length of web. The web may be crushed or may buckle like a short column: check both.
Examples of this type: B1 floor beam: from slab load to strength and deflection (Complete Beam Walkthrough) · B2: the internal beam in the same floor (Interior Beam) · B3: a support reaction loads the next beam (Reaction Transfer) · B3 support: local web bearing and buckling (B3 Local Web Checks) · Initial section selection from load demand (Trial Section Selection) · Local web checks: both modes must pass (Web Bearing and Buckling) · 6 m revision beam: coexisting shear and deflection (Coexistent Shear) · 8 m revision beam: resistance and deformation again (Beam Check Practice)
Unrestrained beam (lateral-torsional buckling)
If nothing holds the compression flange sideways, it moves sideways and twists the whole beam. The moment capacity is then smaller than that of the section alone and has to be calculated separately.
- 1Finish the beam checks first
Loads, shear, moment, classification and deflection are done as for a restrained beam.
- 2Length without restraint
The longer the distance between two lateral restraints, the more easily the beam buckles sideways.
- 3Equivalent slenderness
Allows for how well the section resists twisting, giving the used to enter the table.
- 4Bending strength and buckling resistance
The larger , the smaller the bending strength that can be used. Usually interpolated between two rows.
- 5Compare
When the moment is not at its maximum along the whole length, reduces the demand before comparing with .
Examples of this type: Unrestrained B2: a strong section can still buckle (Unrestrained Beam) · B3 with midspan restraint: complete the LTB procedure (Restrained Segments) · Overhanging beam Q5: separate load patterns and check AB (Overhanging Beam)
Column: axial force with moments
A column is mainly in compression, and a slender one bows sideways before it is crushed. When a beam reaction is off the centre of the column, the column also carries moment; the fractions used up by axial force and by moment are then added.
- 1Axial force and moments
Add the forces from every floor and beam. In simple construction a beam reaction acts 100 mm outside the column face, and the eccentricity causes moment.
- 2Effective length and slenderness
Turn the actual length into an effective length by the end conditions; do each axis separately, the larger slenderness buckles more easily.
- 3Compressive strength and buckling resistance
Choose the buckling curve, then read from and . Take the smaller capacity of the two axes.
- 4Cross-section check
Stops the most heavily loaded section yielding: add the fractions used by the axial force and by the moments about both axes.
- 5Member check 1: buckling
Stops the whole column bowing sideways. The axial term uses the buckling resistance and the moment terms are multiplied by m factors.
- 6Member check 2: lateral-torsional buckling
Moment about the major axis may make the column buckle like a beam, so that term is divided by .
Examples of this type: Pure-compression UC column: from two-axis lookup to capacity (Axial Compression) · Example 5: biaxial checks for a non-sway-frame column (Biaxial Column) · Column Q2: section and member checks for 305×305×118 UC (Column Q2) · Column Q3: biaxial bending of 305×305×198 UC (Column Q3) · Q5: utilisation slightly above 1, judged marginally OK by the lecturer (Marginal Utilization) · Simple-construction column: how beam reactions produce moments (Beam Reactions into Columns) · Column interaction revision: where each ratio comes from (Column Interaction Review)