STEELWORK / CON4334
Learn

Connections: trace the force through bolts, plates and welds

Diagrams, explanations and answers are presented in reading order. No playback or response is required.
All answers shownChinese–English terminology
Diagrams, explanations and answers are presented in reading order. No playback or response is required.

A connection transfers force between pieces of steel.

Identify what crosses the joint before counting bolts or measuring weld.

A force acting along a member can produce bolt shear, plate tension and local bearing at the same time; all relevant resistances must be satisfactory.

Lecture examples are included immediately after the relevant concepts.

Expand an example to read its complete diagram, working, exam answer and self-check here.

Bolts, grades and weld types

Count cuts through each loaded bolt

Find how many shear planes transfer the force through one side of the connection.

The middle plate moves against two cover plates. The two interfaces cut each bolt at two planes.
The middle plate moves against two cover plates. The two interfaces cut each bolt at two planes.

Prediction, then explanation. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Select the area at the actual shear plane. Multiply by bolt shear strength. Count only the bolts and planes in the same transfer stage.

Ps=psAs,Pgroup=nbnsPsP_s=p_sA_s,\qquad P_{group}=n_b n_s P_s

ps is bolt shear strength in N/mm²; As is the appropriate area in mm². nb counts bolts; ns counts equally loaded shear planes.

Scope. Use the thread area when threads cross the plane as required. Check bearing, plate failure and detailing separately.

Check and takeaway. Both halves of a butt splice carry the full transmitted force in sequence. Counting both halves together would double the apparent resistance.

The weld resists through its throat

Convert a visible fillet leg into resistance per effective length.

The two outer sides are the legs. The shorter perpendicular line through the ideal triangle is the throat.
The two outer sides are the legs. The shorter perpendicular line through the ideal triangle is the throat.

Prediction, then explanation. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

For the course right-angle equal-leg fillet, take throat as 0.7 times leg. Multiply throat area per unit length by weld strength.

a=0.7s,qcap=0.7spw/1000a=0.7s,\qquad q_{cap}=0.7sp_w/1000

s and a are leg and throat in mm. pw is weld strength in N/mm². qcap is resistance in kN/mm.

Scope. Use effective length, the correct steel/electrode strength and permitted leg limits. Full-penetration butt welds use a different model.

Check and takeaway. Illustration: a 6 mm leg at 250 N/mm² gives 0.7(6)(250)/1000=1.05 kN/mm0.7(6)(250)/1000=1.05\,\mathrm{kN/mm}.

Penetration changes the resisting section

Determine whether the weld develops the full joint thickness or only an effective part.

FullPartialroot
The full-penetration sketch joins the entire thickness. The partial-penetration sketch leaves a root region outside the effective weld.

Prediction, then explanation. Keeping the same plate thickness does not make partial and full penetration equivalent.

Identify the weld preparation and effective thickness. Apply the supplied resistance and inspection requirements to that actual detail.

Penetration describes how deeply the joint is fused. A fillet leg is a different dimension.

Scope. Do not apply the fillet factor 0.7 to a butt weld merely because both are welds. Inspection and workmanship remain part of the specified requirements.

Check and takeaway. A sketch must show the effective fused region. The outside plate outline alone cannot distinguish penetration types.

Apply the reasoning to this section’s data and conditions

Source: Chapter 2 pp.2–3 and 6–7.

An ordinary clearance bolt transfers load through contact between its shank and the hole after any clearance movement.

A friction-grip connection uses clamping and friction; ordinary bearing-bolt equations alone are not an HSFG slip check.

For the ordinary Grade 8.8 bolts used in the worked examples, the course tables give ps=375, pbb=1,000 and pt=560Nmm2.

Their nominal material ultimate tensile strength Ub=800Nmm2 is a different quantity.

A grade label 8.8 indicates nominal ultimate strength 800Nmm2 and yield ratio 0.8, hence nominal yield strength 640Nmm2 in Chapter 2 Table 1.

The code design strengths above are the values to use for capacity.

Grade 4.6 has nominal yield/ultimate 240/400; Grade 10.9 has 900/1,000Nmm2.

Chapter 2 p.7, Figure 3. A fillet joins intersecting surfaces; butt welds use prepared grooves. The leg and throat are different dimensions.

Chapter 2 p.7, Figure 3: weld leg and throat are different dimensions.

The original labels identify Single V butt weld, Fillet weld, Single U/Double V/Double U preparations, Partial butt weld and Deep penetration fillet weld.

Local labels identify Root, Angle of faces, Reinforcement, Gap and Throat; Size=leg length means the specified dimension equals the leg length; Fusion zone identifies the fused region.

The middle detail in sketch (d) combines a partial-penetration butt weld with fillet welds.Open full-size image

Fillet welds have a triangular profile.

The specified size s is the leg, not the throat.

Butt welds join prepared plate edges, such as single/double V or U preparations.

Visual inspection, dye penetrant and magnetic-particle methods look for surface issues; ultrasonic and X-ray methods can detect internal defects as described in the notes.

Mechanism detailsCount the bolt shear planes3 concepts · 5 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Load must cross an interface between the connected plates.
  2. A lap joint gives one shear plane through a bolt.
  3. A symmetric double-cover joint may provide two shear planes.

    Count load-transfer interfaces, not just visible plates.

  4. Use the source’s area and shear strength.

    Then check bearing, plate resistance and detailing separately.

Hole size, pitch, gauge and edge distances

A bolt diameter is not a hole diameter

Check that bolts fit and leave enough material between holes and plate boundaries.

pdd₀Clear ligament
The inner circle represents bolt diameter d. The outer circle represents hole diameter d₀. Pitch and gauge join hole centres.

Prediction, then explanation. At fixed pitch, a larger hole leaves a shorter clear ligament. Increasing bolt diameter may also increase minimum edge-distance requirements.

Measure pitch along the bolt line and gauge across lines. Distinguish end distance along the load from edge distance across it.

lc=p−d0l_c=p-d_0

lc is clear ligament between holes; p is centre-to-centre pitch; d₀ is hole diameter. All use mm.

Scope. Apply the supplied edge-preparation and minimum/maximum spacing rules. Passing a bearing calculation does not prove the layout passes.

Check and takeaway. For pitch 60 mm and hole diameter 22 mm, the ligament is 38 mm. Using a 20 mm bolt diameter here gives the wrong ligament.

Apply the reasoning to this section’s data and conditions

Physical interpretation: The bolt can crush or tear the plate

A strong bolt can still push through a weak hole edge.

The bolt can crush or tear the plate — A strong bolt can still push through a weak hole edge.

Sketch, not to scale; use the original dimensions.

  1. Check the bolt and each connected plate’s bearing bounds.
  2. Use nominal bolt diameter for bearing; hole size for removed material.
  3. The smallest applicable resistance controls.

Remember: A short end distance may govern even when bolt shear passes.

Related concept and full method

Source: Chapter 2 pp.3–4.

Nominal bolt diameter d is the steel shank size.

Hole diameter d0 is larger: d+2mm for d≤24mm, d+3mm for larger ordinary bolts.

Use d for bearing area and spacing rules; d0 for material removed by holes.

Chapter 2 p.4, Table 9.3 extract: choose the bolt size row and the correct edge-manufacture column.

Chapter 2 p.4, Table 9.3 extract: minimum end and edge distances for standard holes.

Each pair gives, first, sheared/hand flame-cut edges and, second, rolled plate/section/bar edges or machine gas-cut edges, in mm.

Source rows: M12: 22/18; M16: 28/22; M18: 32/24; M20: 34/26; M22: 38/28; M24: 42/30; M27 and above: 1.75d/1.25d.

First select the bolt-size row, then the edge preparation.Open full-size image

Minimum pitch along the load direction: 2.5d.
General minimum gauge transverse to the load: 3d.
Maximum pitch/gauge: min(12t,150mm), where t is the thinner connected-plate thickness.
Maximum edge distance: 11tε; ε=275py.

End distance is from the hole centre to the plate end in the load direction.

Edge distance is from hole centre to an adjacent side edge.

Minimum values depend on edge preparation.

For M20, the supplied Table 9.3 gives 34mm at sheared/hand-flame-cut edges and 26mm at rolled, sawn or machine-cut edges.

You cannot call a layout satisfactory without identifying the applicable edge type.

Example 2 explicitly checks a rolled edge.

Mechanism detailsBolt centres, holes and edges1 concept · 2 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Hole diameter d₀ differs from nominal bolt diameter d.

    Net-section deductions use the specified hole.

  2. Pitch runs along the load direction; gauge measures spacing across rows.
  3. End and edge distances start at the hole centre.

    The remaining ligament starts at the hole boundary.

  4. Minimum spacing, edge distances, grip and plate thickness come from the specified rules, not this scaled illustration.

Recognise the competing failure modes

Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Follow contact pressure into the plate

The bolt may survive shear while the connected plate deforms or tears near the hole.

The labels distinguish bolt diameter d from hole diameter d₀. The arrow at the hole edge shows the bearing contact action.
The labels distinguish bolt diameter d from hole diameter d₀. The arrow at the hole edge shows the bearing contact action.

Prediction, then explanation. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.

Calculate every bound required by the supplied rule. The smallest applicable bound limits the connection at that layer.

Pbearing≤pbsdtP_{bearing}\le p_{bs}dt

pbs is the applicable bearing strength in N/mm²; d is nominal bolt diameter in mm; t is plate thickness in mm.

Scope. This diameter term alone is not the complete check. End-distance and clear-ligament limits, bolt bearing and each connected layer also matter.

Check and takeaway. Two covers and one main plate do not necessarily have the same thickness or strength. Compare the actual force share in each layer.

Test every possible fracture cut

Find the remaining steel area across a candidate tension-failure path.

The dashed fracture line crosses two hole centres. Subtract only the holes crossed by that candidate line.
The dashed fracture line crosses two hole centres. Subtract only the holes crossed by that candidate line.

Prediction, then explanation. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.

Subtract the hole widths crossed by the path, then multiply by thickness. Compare all plausible paths using the applicable course rule.

An=(b−nd0)tA_n=(b-nd_0)t

An is net area in mm²; b is plate width; d₀ is hole diameter; t is thickness, all in mm. n counts holes on this straight path.

Scope. This expression is for a straight cut. Effective area can require further shear-lag rules. Gross, net and effective areas must remain distinct.

Check and takeaway. Use the hole diameter, not the bolt diameter, when removing missing steel. The plate contains a hole, not solid steel around the bolt shank.

Apply the reasoning to this section’s data and conditions

Source: Chapter 2 p.8.

The bolt may shear across its cross section; bolt or plate may crush locally at the hole (bearing).

The plate may tear across its net tensile section.

A short plate end may tear out; or a block bounded by shear and tension paths may pull out.

Increasing bolt size also increases the hole size.

The larger hole removes more plate material.

Therefore a larger bolt may leave the net section weaker.

Use a load-path check: main plate → bolts or weld → cover/gusset → connected member.

Resistances in series are compared using the minimum.

Two identical cover plates sharing a load in parallel have capacities that can be added.

The groups on opposite sides of a splice are in series: each side must transfer the whole splice force.

Mechanism detailsCount the bolt shear planes4 concepts

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Load must cross an interface between the connected plates.
  2. A lap joint gives one shear plane through a bolt.
  3. A symmetric double-cover joint may provide two shear planes.

    Count load-transfer interfaces, not just visible plates.

  4. Use the source’s area and shear strength.

    Then check bearing, plate resistance and detailing separately.

Shear planes and bolt shear capacity

Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Count where the bolt can be sheared

The plate interfaces are the places trying to cut across the bolt.

Count where the bolt can be sheared — The plate interfaces are the places trying to cut across the bolt.

Sketch, not to scale; use the original dimensions.

  1. Count actual loaded shear planes, not merely visible plates.
  2. Choose shank or threaded area for the plane concerned.
  3. Compare group resistance with the force that group transfers.

Remember: Bolts on opposite sides of a splice do not all act in parallel.

Related concept and full method

Chapter 2 p.3, Figure 2: the left lap joint has one shear interface; the central plate between two covers gives two interfaces.

Chapter 2 p.3, Figure 2: single shear at left, double shear at right.

The upper side views show the plate layers.

The lower plans show hole positions.

Labels identify end distance, edge distance and centre spacing.

F and the load arrows show forces pulling the joint apart.

The two shear interfaces come from sandwiching the main plate between two cover plates, not from having two rows of holes in plan.Open full-size image

Use tensile stress area As where the threads may lie in the shear plane.

Use full shank area only when it is certain threads cannot be there.

For M16/M20/M24/M30 the tensile stress areas are 157/245/353/561mm2 in the supplied table.

One shear plane: Ps=psAs1,000kNTwo identical shear planes: Ps,total=2psAs1,000kN

The “/1,000” converts N to kN: stress Nmm2 × area mm2 = N.

For a concentric group of n equally loaded bolts, applied force per bolt is Pn.

For an eccentric group, use the maximum resultant force found from direct force plus moment; Pn alone misses torsion.

Prediction and explained answer.

A Grade 8.8 M20 bolt has threads in two shear planes.

Find its shear capacity.

Answer and reasoning

2×375×2451,000=183.75kN.

One-plane capacity is 91.875kN.

Double shear is a geometry fact, not a property of Grade 8.8.

Mechanism detailsCount the bolt shear planes1 concept · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Load must cross an interface between the connected plates.
  2. A lap joint gives one shear plane through a bolt.
  3. A symmetric double-cover joint may provide two shear planes.

    Count load-transfer interfaces, not just visible plates.

  4. Use the source’s area and shear strength.

    Then check bearing, plate resistance and detailing separately.

Mechanism detailsCount the bolt shear planes1 concept · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Load must cross an interface between the connected plates.
  2. A lap joint gives one shear plane through a bolt.
  3. A symmetric double-cover joint may provide two shear planes.

    Count load-transfer interfaces, not just visible plates.

  4. Use the source’s area and shear strength.

    Then check bearing, plate resistance and detailing separately.

Bearing and end tear-out: calculate every bound

Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.

Apply the reasoning to this section’s data and conditions

Physical interpretation: The bolt can crush or tear the plate

A strong bolt can still push through a weak hole edge.

The bolt can crush or tear the plate — A strong bolt can still push through a weak hole edge.

Sketch, not to scale; use the original dimensions.

  1. Check the bolt and each connected plate’s bearing bounds.
  2. Use nominal bolt diameter for bearing; hole size for removed material.
  3. The smallest applicable resistance controls.

Remember: A short end distance may govern even when bolt shear passes.

Related concept and full method

Source: Chapter 2 pp.9–10.

Bearing is local crushing where a bolt pushes on its hole.

The projected bearing area is d×tp, not πd24.

A symmetric double-cover splice divides force equally between the covers.

Compare the main thickness with the sum of the cover thicknesses.

Alternatively, check the main plate at full load and each cover at half load.

Bolt bearing: Pbb=dtppbb1,000Connected-plate resistance corresponding to each bolt is min(B1,B2,B3), where:B1=kbsdtppbs1,000B2=0.5kbsetppbs1,000B3=min(1.5lctpUs,2dtpUb)1,000

d, tp, e and lc are in mm.

e is end distance measured along load transfer.

lc is the clear ligament between neighbouring hole edges in that direction: for aligned equal holes, pitch − d0.

kbs=1 for standard holes, 0.7 for oversize/short slots in this extract.

For S355, pbs=550 and Us=510Nmm2.

For Grade 8.8, Ub=800Nmm2.

This notation lc can look like Ic in the source.

It is a length, not a moment of inertia.

The first bound checks bearing strength, the second captures end-distance limitation, and the third includes a clear-ligament limit and an upper cap.

Write all numbers before taking the minimum.

Do not apply the largest result as capacity.

Mechanism detailsBearing and the remaining ligament1 concept · 5 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Force transfers through contact between bolt and connected plate.
  2. The plate around the hole carries bearing stress.

    Bolt bearing and plate bearing are separate checks.

  3. A short ligament can tear out towards the end.

    The direction of force determines the relevant edge.

  4. Evaluate every specified bearing and ligament bound for each layer and retain the smallest applicable resistance.

Tension and the prying assumption

An eccentric bracket pulls bolts differently

An out-of-plane moment rotates the bracket about the stated pivot. Determine the bolt tension pattern.

The pivot is the compression reference. Bolts farther from it have longer lever arms in the course elastic model.
The pivot is the compression reference. Bolts farther from it have longer lever arms in the course elastic model.

Prediction, then explanation. For unchanged geometry, doubling the applied moment doubles the modelled bolt tensions. Changing the pivot changes the distribution.

Use compatibility to relate tension to distance. Moment equilibrium then determines the proportionality factor.

Ft,i=Myi∑yj2F_{t,i}=\frac{My_i}{\sum y_j^2}

M is moment in kN·mm. yi is distance from the stated pivot in mm. Ft,i is tension in kN.

Scope. Apply only to the stated active bolt set and pivot model. Flexible plates can create prying; use the supplied assumptions and resistance definitions.

Check and takeaway. A bolt’s lever arm is measured from the pivot used in the equation. It is not automatically its distance from the group centroid.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Why the top bolt row is pulled hardest

The bracket tries to peel away from the support about the assumed contact line.

Why the top bolt row is pulled hardest — The bracket tries to peel away from the support about the assumed contact line.

Sketch, not to scale; use the original dimensions.

  1. Use the rotation/contact line assumed by the course model.
  2. Measure each bolt row’s distance from that line.
  3. Check maximum tension, direct shear and their interaction.

Remember: A row at the pivot can still carry direct shear.

Related concept and full method

Source: Chapter 2 pp.10–11.

Bolt tension acts along the bolt axis, trying to separate connected surfaces.

The direct tensile capacity is Pt=Aspt.

For the course’s simplified treatment avoiding explicit prying-force design, use reduced nominal tension Pnom=0.8Aspt.

M20, Grade 8.8: Pt=245×5601,000=137.2kNPnom=0.8×137.2=109.76kN

The source Clause 9.3.7.2 extract also restricts flange bolt gauge G≤0.55B for UB/UC/T flange details.

The capacity reduction by 0.8 does not prove that prying is absent in every flexible plate.

The simplified bracket model requires appropriate gauge and plate details.

If those details are missing, keep the conclusion conditional.

The calculation does not establish a complete joint design.

Mechanism detailsOut-of-plane bolt tension and prying1 concept · 4 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. A bracket moment can create compression at the plate contact and tension in the bolt rows.
  2. The original assumed pivot/compression line determines each row distance.
  3. Under the elastic row model, a farther tension row attracts more tension.

    Direct shear may act simultaneously.

  4. Flexible plates can add prying force.

    Use nominal tension and interaction rules exactly as specified by the course.

Gross, net and effective area

Use the same mechanism: Test every possible fracture cut. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Why holes reduce tension resistance

The pull must squeeze through the steel left beside the holes.

Why holes reduce tension resistance — The pull must squeeze through the steel left beside the holes.

Sketch, not to scale; use the original dimensions.

  1. Choose a possible fracture line across the member.
  2. Subtract the holes crossed by that line using hole diameter.
  3. Apply the course effective-area rule and its gross-area limit.

Remember: Do not subtract every hole anywhere in the connection.

Related concept and full method

Source: Chapter 2 pp.11–12.

Gross area includes the original steel.

Net area subtracts hole area along a possible fracture line normal to force.

Effective tension area applies the course net-area coefficient but cannot exceed the corresponding gross area.

Steel plate: Ag=bt;An=(b−nd0)t;Ae=min(KeAn,Ag)Ke=1.2 (S275) , 1.1 (S355) , 1.0 (S460) .

Here n is the number of holes crossed by the fracture line, not the total bolts along the connection.

In a two-row splice, a straight transverse section crosses two holes even when many bolts lie along the length.

Chapter 2 p.12, Figures 9.7–9.8: straight and zigzag fracture paths and the developed gauge for angle legs.

Chapter 2 p.12, Figures 9.7–9.8.

Figure 9.7 identifies the direction of force; D = hole diameter; t = plate thickness; an = net area; b = plate width.

Upper-case S1 to S4 marks longitudinal stagger; g1 to g3 marks transverse gauge.

The three path expressions in source order are:① an=t(b−2D); ② an=t(b−3D+0.25S22g1); ③ an=t(b−4D+0.25S42g1+0.25S42g2+0.25S42g3).

Figure 9.8: heel means the angle root.

The developed gauge across the two legs is g=g1+g2−t.

All dimensions follow their source locations.

Do not estimate values from drawing scale.Open full-size image

For staggered holes, compare all credible straight and zigzag net areas.

For each diagonal step, the deduction is reduced by s2t4g, where s is longitudinal stagger and g transverse gauge.

Thus An=Ag−Σd0t+Σs2t4g.

Select the smallest net area, equivalent to the largest deduction.

For bolts on both angle legs, use the developed gauge g1+g2−t shown in the source.

This course supplies the geometric rule, not a numbered staggered calculation.

For shear area, the notes permit ignoring holes only if Av,net≥0.85AvKe.

Otherwise the stated net shear capacity is 0.7pyKeAv,net.

This is distinct from the ordinary gross rolled-beam shear formula.

Connection example 2: design a bolted tension splice

Design a double-cover splice for an already ultimate tensile force of 700kN. Main plates are 150mm wide ×20mm thick; two S355 cover plates are 12mm thick. Use Grade 8.8 M20 bolts in 22mm holes, 50mm pitch and 40mm end distance.

Original source: LectureNotes/Ch 2_Connection.pdf — p. 18, p. 19, p. 20.

A given value comes from the question or diagram.

A lookup value comes from the named table.

A calculated value follows from the working.

Each assumption is stated where the calculation needs it.

Known information, diagram labels and unknowns

Use the same mechanism: A bolt diameter is not a hole diameter. At fixed pitch, a larger hole leaves a shorter clear ligament. Increasing bolt diameter may also increase minimum edge-distance requirements.

Change the ruler, keep the quantity

A section table uses centimetres, but the strength calculation uses millimetres. The numbers must describe the same section.

Length1 factorArea2 factors3 factorsEach centimetre becomes ten millimetres.
In the diagram, the length, square and cube contain one, two and three length factors. Each factor changes when the ruler changes.

Prediction, then explanation. Would every property increase by ten? No. The exponent determines how many factors of ten are needed.

First identify the physical quantity. Next convert each length factor. Keep force and length conversions separate when converting a moment.

1 cmn=10n mmn,1 kN m=106 N mm1\,\mathrm{cm}^n=10^n\,\mathrm{mm}^n,\qquad 1\,\mathrm{kN\,m}=10^6\,\mathrm{N\,mm}

Here n is the length exponent: 2 for area, 3 for section modulus and 4 for second moment of area.

Scope. Changing units changes neither the load nor the section. A conversion factor cannot repair a formula for the wrong physical quantity.

Check and takeaway. Illustration: 2 cm4=20,000 mm42\,\mathrm{cm}^4=20{,}000\,\mathrm{mm}^4. The fourth power belongs to the unit, not the number 2.

A table value has conditions

Find a design property without mixing a row, column or standard from a different case.

The row and column meet at one cell. The table heading supplies the units and the conditions that give the cell meaning.
The row and column meet at one cell. The table heading supplies the units and the conditions that give the cell meaning.

Prediction, then explanation. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Match the complete section designation. Read the relevant axis and unit. For strength tables, select material, thickness and curve before interpolating.

Given values come from the question. Lookup values come from a named table. Assumed values require an explicit condition.

Scope. A missing row or omitted restraint cannot be recovered from a schematic’s scale. Keep the result conditional when required data are absent.

Check and takeaway. Record the table, row, column and unit beside the substitution. That makes a later check possible.

Apply the reasoning to this section’s data and conditions

InputOrigin
Given demand

700kN ultimate.

No further factor.

Given thicknesses

Main t2=20mm.

Each cover t1=12mm; cross-section view labels each ply.

Given hole/pitch/endM20 → d=20; stated hole d0=22; longitudinal pitch 50; end 40mm.
Selected layoutp.19 drawing: two rows, gauge 90mm, side edges 30mm, two columns per half-splice.
Lookup

As=245mm2, ps=375, pbb=1,000; S355 pbs=550, Us=510, Ke=1.1.

Main py=345 for 20mm; covers py=355 for 12mm.

All stress units Nmm2.

Why this method applies

Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

Each half-splice must transfer the full 700kN from a main plate into the covers.

The covers each take half that force.

Bolts have two shear planes; compare main thickness 20 with total cover thickness 24 for the bearing path.

Select bolt count from the weakest per-bolt mode, round up, arrange the bolts, then check the plates cut by those holes.

1. Establish the capacity of one bolt and its bearing path

Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.

Use the same mechanism: A bolt diameter is not a hole diameter. At fixed pitch, a larger hole leaves a shorter clear ligament. Increasing bolt diameter may also increase minimum edge-distance requirements.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Count where the bolt can be sheared

The plate interfaces are the places trying to cut across the bolt.

Count where the bolt can be sheared — The plate interfaces are the places trying to cut across the bolt.

Sketch, not to scale; use the original dimensions.

  1. Count actual loaded shear planes, not merely visible plates.
  2. Choose shank or threaded area for the plane concerned.
  3. Compare group resistance with the force that group transfers.

Remember: Bolts on opposite sides of a splice do not all act in parallel.

Related concept and full method

Double shear: Ps=2×375×2451,000=183.75kNtp=min(20,2×12)=20mmBolt bearing: Pbb=20×20×1,0001,000=400kNlc=pitch−hole diameter=50−22=28mmB1=1×20×20×5501,000=220kNB2=0.5×1×40×20×5501,000=220kNNet-clearance term between holes: 1.5×28×20×5101,000=428.4kNUpper cap: 2×20×20×8001,000=640kNConnected-plate resistance: min(220,220,428.4,640)=220kNGoverning resistance per bolt: min(183.75,400,220)=183.75kN

Using total cover thickness 24 is valid here because the two identical covers share the force symmetrically.

An unequal cover arrangement would need separate load-sharing checks.

Mechanism detailsCount the bolt shear planes4 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Load must cross an interface between the connected plates.
  2. A lap joint gives one shear plane through a bolt.
  3. A symmetric double-cover joint may provide two shear planes.

    Count load-transfer interfaces, not just visible plates.

  4. Use the source’s area and shear strength.

    Then check bearing, plate resistance and detailing separately.

2. Select bolts on each side of the splice

Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Apply the reasoning to this section’s data and conditions

n≥700183.75=3.80952→ Select 4 bolts per half-joint. Resistance per half: 4×183.75=735kN>700kNDemand per bolt: 7004=175kN<183.75kN

Provide four on the left and four on the right: eight physical bolts in total.

The eight do not jointly give “1,470kN” across the splice, because the left and right groups carry the same force in series.

Mechanism detailsCount the bolt shear planes1 concept · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Load must cross an interface between the connected plates.
  2. A lap joint gives one shear plane through a bolt.
  3. A symmetric double-cover joint may provide two shear planes.

    Count load-transfer interfaces, not just visible plates.

  4. Use the source’s area and shear strength.

    Then check bearing, plate resistance and detailing separately.

3. Verify the selected layout

Use the same mechanism: A bolt diameter is not a hole diameter. At fixed pitch, a larger hole leaves a shorter clear ligament. Increasing bolt diameter may also increase minimum edge-distance requirements.

Apply the reasoning to this section’s data and conditions

The two transverse rows are separated by 90mm.

Width closure:30+90+30=150mm.

Longitudinal pitch 50 and end 40 are the specified values.

Use the source’s rolled-edge condition in Table 9.3, M20 row: minimum 26mm.

Minimum pitch: 2.5×20=50mm≤provided50Maximum pitch/gauge: min(12×12,150)=144mm50 and 90≤144. General minimum gauge: 3×20=60mm<90The minimum end/edge distance requirement is 26mm. The provided end and edge distances respectively satisfy 26mm<40mm26mm<30mmMaximum cover-plate edge distance: 11×12×275355=116.18mm>30Maximum main-plate edge distance: 11×20×275345=196.42mm>30

Mechanism detailsBolt centres, holes and edges1 concept · 3 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Hole diameter d₀ differs from nominal bolt diameter d.

    Net-section deductions use the specified hole.

  2. Pitch runs along the load direction; gauge measures spacing across rows.
  3. End and edge distances start at the hole centre.

    The remaining ligament starts at the hole boundary.

  4. Minimum spacing, edge distances, grip and plate thickness come from the specified rules, not this scaled illustration.

4. Check main-plate tension across two holes

Use the same mechanism: Test every possible fracture cut. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Why holes reduce tension resistance

The pull must squeeze through the steel left beside the holes.

Why holes reduce tension resistance — The pull must squeeze through the steel left beside the holes.

Sketch, not to scale; use the original dimensions.

  1. Choose a possible fracture line across the member.
  2. Subtract the holes crossed by that line using hole diameter.
  3. Apply the course effective-area rule and its gross-area limit.

Remember: Do not subtract every hole anywhere in the connection.

Related concept and full method

The critical straight transverse line crosses one hole in each row: two 22mm holes.

Do not deduct all four holes along a half-splice.

Thickness 20mm selects py=345Nmm2.

Ag=150×20=3,000mm2An=(150−2×22)×20=106×20=2,120mm2Ae=min(1.1×2,120,3,000)=2,332mm2Pt=2,332×3451,000=804.54kN>700Passes.

Mechanism detailsSubtract holes on the failure path1 concept · 2 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Gross area counts the complete plate width and thickness.
  2. The highlighted transverse path passes through the bolt holes.
  3. For the straight illustrative path, .

    Staggered paths require their specified correction.

  4. Net area is not always effective area.

    Include the course’s strength ratio or shear-lag rule when applicable.

5. Check both covers and conclude

Use the same mechanism: Test every possible fracture cut. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.

Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Apply the reasoning to this section’s data and conditions

Each cover plate: Ag=150×12=1,800mm2An=(150−44)×12=1,272mm2Ae=min(1.1×1,272,1,800)=1,399.2mm2Pt=1,399.2×3551,000=496.716kN>350kNBoth plates together: Pt=2×496.716=993.432kN>700kN

All requested checks pass under the stated rolled-edge layout.

The least load-path resistance is bolt shear 735kN.

The source gives approximately 993.2kN for covers after intermediate rounding; carrying full precision gives 993.43kN.

Mechanism detailsSubtract holes on the failure path2 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Gross area counts the complete plate width and thickness.
  2. The highlighted transverse path passes through the bolt holes.
  3. For the straight illustrative path, .

    Staggered paths require their specified correction.

  4. Net area is not always effective area.

    Include the course’s strength ratio or shear-lag rule when applicable.

Result and concise exam wording

Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Use the same mechanism: Test every possible fracture cut. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.

Use the same mechanism: A bolt diameter is not a hole diameter. At fixed pitch, a larger hole leaves a shorter clear ligament. Increasing bolt diameter may also increase minimum edge-distance requirements.

Apply the reasoning to this section’s data and conditions

Four M20 Grade 8.8 bolts per side (eight total), two rows with 90mm gauge,50mm pitch,40mm ends and 30mm rolled edges.

Double-shear resistance 735kN per half; bearing exceeds this.

Main tension 804.54kN; combined cover tension 993.43kN.

Each exceeds 700kN.

Layout passes for the source’s rolled-edge assumption.

Misconceptions and checks

Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Use the same mechanism: Test every possible fracture cut. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

  • Do not factor the already ultimate 700kN.
  • Four bolts are required on each side of the plate butt.
  • Double shear doubles bolt shear, not the main-plate thickness.
  • A transverse net section crosses two holes, not four.

How the method transfers to a new variant

Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.

Use the same mechanism: Test every possible fracture cut. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.

Apply the reasoning to this section’s data and conditions

  1. Trace one half-splice at full force and each cover at its share.
  2. Calculate per-bolt shear/bearing and take the minimum.
  3. Round up bolt count and draw a feasible layout.
  4. Check every pitch/edge rule using the thinner ply and correct edge finish.
  5. Check main and cover effective tension areas independently.

Prediction with explained answer

Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Use the same mechanism: Test every possible fracture cut. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.

Apply the reasoning to this section’s data and conditions

Prediction and explained answer.

If the required ultimate force becomes 760kN but the splice is unchanged, which calculated resistance fails first?

Hint

Compare 760 with the complete group resistance, not just one bolt.

Answer and reasoning

Bolt shear 735kN is inadequate.

Main-plate tension 804.54kN and cover-pair tension 993.43kN still exceed 760.

Adding bolts changes the layout and may change the fracture path, so repeat layout/net-area checks.

Mechanism detailsSubtract holes on the failure path1 concept · 7 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Gross area counts the complete plate width and thickness.
  2. The highlighted transverse path passes through the bolt holes.
  3. For the straight illustrative path, .

    Staggered paths require their specified correction.

  4. Net area is not always effective area.

    Include the course’s strength ratio or shear-lag rule when applicable.

Block shear

A block leaves along two types of path

A connection can lose a block of plate without a single straight tensile fracture across the full width.

The longitudinal dashed segments are shear paths. The transverse closing segment is a tension path.
The longitudinal dashed segments are shear paths. The transverse closing segment is a tension path.

Prediction, then explanation. Changing the end distance changes the shear-path geometry. Adding plate width elsewhere may not strengthen the controlling block.

Draw the possible block first. Label shear and tension segments. Apply the course deductions and strength terms to their respective areas.

Shear and tension areas use mm². Their strength coefficients refer to different mechanisms and are not interchangeable.

Scope. Do not replace the supplied block-shear expression with the simple net-tension formula. Geometry and deductions depend on the actual path.

Check and takeaway. A complete path must release a block. A dashed line that does not enclose a removable piece is not that failure mechanism.

Apply the reasoning to this section’s data and conditions

Physical interpretation: A whole block can pull out

Think of tearing a small tab out of a sheet along several connected edges.

A whole block can pull out — Think of tearing a small tab out of a sheet along several connected edges.

Sketch, not to scale; use the original dimensions.

  1. Trace the complete block around the bolt group.
  2. Separate edges sliding in shear from the edge pulled in tension.
  3. Deduct holes only where the applicable path crosses them.

Remember: One straight net-section check does not cover block shear.

Related concept and full method

Chapter 2 p.13, Figure 9.9: a block can tear along the longitudinal bolt line and across its transverse end.

Chapter 2 p.13, Figure 9.9: Block Shear and Effective Shear Area.

In the figure, Ft is the applied tension.

Lv is measured along the candidate shear plane.

Lt is measured across the tensile plane.

Cope identifies the beam-end notch.

Arrows show the interaction between the block and the remaining member.

Path directions differ with the detail.

Do not substitute the whole plate perimeter.Open full-size image

Read Lv along the prospective shear face and Lt across the tensile face, as labelled on the original detail.

The source’s effective-area expression is Av,eff=t[Lv+Ke(Lt−kDt)], followed by Pr=0.6pyAv,eff.

Dt is the tensile-face hole diameter.

For slots use the dimension normal to load.

The extract gives k=0.5 for a single bolt row or 2.5 for two rows.

Match the illustrated path.

Do not substitute the whole plate length or an arbitrary bolt-group perimeter.

No numerical block-shear example with all path dimensions is supplied.

Mechanism detailsSeparate the block-shear paths1 concept · 3 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. A block containing the connection can detach from the surrounding plate.
  2. The paths parallel to the applied force carry shear.
  3. The closing path across the end of the block carries tension.
  4. Use the specified gross/net deductions and resistance expression.

    This is different from a single straight net-section fracture.

Single and double angles connected through one leg

One connected leg does not load both legs equally

An angle carries tension through only one leg. Determine how much section area the design rule permits.

The force enters the connected leg first. The outstanding leg receives force through the angle corner and adjoining material.
The force enters the connected leg first. The outstanding leg receives force through the angle corner and adjoining material.

Prediction, then explanation. Keeping the same gross area does not guarantee the same tension resistance when the connection arrangement changes.

Separate connected and outstanding leg areas. Include the actual holes. Then use the supplied single-angle or double-angle effective-area rule.

Pt=pyAeP_t=p_yA_e

Ae is the effective area from the applicable angle rule in mm². py is the relevant design strength in N/mm².

Scope. Do not assume the whole gross area is effective. Symmetry, connected leg and connection type determine which rule applies.

Check and takeaway. The outstanding leg contributes through load transfer; the rule need not either count all of it or discard all of it.

Use the same mechanism: Test every possible fracture cut. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.

Apply the reasoning to this section’s data and conditions

Physical interpretation: One connected leg does not load both legs equally

The connected leg receives the pull first.

The other leg receives it through the angle.

One connected leg does not load both legs equally — The connected leg receives the pull first; the other leg receives it through the angle.

Sketch, not to scale; use the original dimensions.

  1. Identify connected and outstanding legs from the drawing.
  2. Use the relevant bolted or welded angle rule.
  3. Keep the lecturer’s area convention consistent.

Remember: Bolted and welded reduction expressions are not the same rule.

Related concept and full method

Source: Chapter 2 pp.14–15.

The unconnected leg does not receive the load directly.

Therefore, the effective tension resistance is reduced.

Let a2 be the gross area of the unconnected leg and Ae the sum of effective leg areas.

Avoid counting the heel overlap twice: the lecture’s rectangular approximation allocates half the thickness to each leg.

ConnectionCapacity
Single angle, boltedPt=py(Ae−0.5a2)
Single angle, weldedPt=py(Ae−0.3a2)
Double angles on both sides of gusset, interconnected, boltedPt=py(Ae−0.25a2)
Same double-angle arrangement, weldedPt=py(Ae−0.15a2)

Use either total areas for the pair or calculate one identical angle at half load and double its capacity.

Do not use total area and then double the answer again.

For tension members with separately applied moments the notes give FtPt+MxMcx+MyMcy≤1.

The specified reduction already allows for nominal connection eccentricity in the listed single-leg shapes.

Add a separate moment only when the task requires one.

Connection example 1: single bolted unequal angle

Check a single S355 80×60×8mm angle connected through its long leg to a 10mm plate by the stated two Grade 8.8 M20 bolts. Dead tension is 75kN; imposed tension is 40kN. Check bolt shear, bolt/plate bearing and angle tension.

Original source: LectureNotes/Ch 2_Connection.pdf — p. 16, p. 17.

A given value comes from the question or diagram.

A lookup value comes from the named table.

A calculated value follows from the working.

Each assumption is stated where the calculation needs it.

Known information, diagram labels and unknowns

Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Use the same mechanism: Test every possible fracture cut. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.

Use the same mechanism: A bolt diameter is not a hole diameter. At fixed pitch, a larger hole leaves a shorter clear ligament. Increasing bolt diameter may also increase minimum edge-distance requirements.

Apply the reasoning to this section’s data and conditions

InputValue and exact source
Given loads

75kN dead and 40kN imposed, question text.

The downward arrow is the resulting tension direction.

Given geometry

Long leg 80mm; short leg 60mm; t=8mm.

The split dimensions 76 and 56 allocate half the heel thickness to each leg.

Given fastenersText specifies TWO M20 Grade 8.8 bolts; standard 22mm holes; 50mm pitch; 45mm end distance.
Given plate/model10mm supporting plate; one shear plane explicitly stated.
Lookup

Ch 2 p.3 M20 tensile stress area As=245mm2.

Ch 2 pp.9–10 Grade 8.8: ps=375, pbb=1,000, Ub=800Nmm2.

S355: pbs=550, Us=510, Ke=1.1.

Data File p.1, thickness ≤16mm: py=355.

Why this method applies

Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.

Use the same mechanism: Test every possible fracture cut. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.

Apply the reasoning to this section’s data and conditions

This is concentric tension through one connected angle leg.

The load crosses the angle-to-plate interface as bolt shear, presses on holes as bearing, and remains tension in the angle.

Start with the factored force.

Check each fastener mode, then the reduced angle tension resistance.

Prerequisites: stress×area gives force; “net area” removes holes.

A single-leg connection needs the specific unconnected-leg reduction.

1. Convert characteristic loads to one design force

Keep load categories separate

A floor carries permanent material and changing occupancy loads. Find the design load for the stated check.

The two boxes show G and Q with their separate factors. The plus sign joins their factored values.
The two boxes show G and Q with their separate factors. The plus sign joins their factored values.

Prediction, then explanation. Increasing imposed load changes its own term. It does not change the dead-load factor or the steel stiffness.

First convert mass to weight where required. Next collect G and Q in compatible units. Apply the combination specified by the course problem.

Wu=1.4G+1.6QW_u=1.4G+1.6Q

G is characteristic dead load; Q is characteristic imposed load. Wu is the design load for this course gravity combination.

Scope. This combination is not universal. Use the specified service load for deflection and the stated factors for other standards or cases.

Check and takeaway. Illustration: G = 10 kN and Q = 5 kN give 22 kN. Factoring their sum by one guessed factor loses the distinction.

Apply the reasoning to this section’s data and conditions

P is the ULS tensile demand in kN.

Apply the course gravity factors once.

The supplied loads are characteristic, not already ultimate.

P=1.4G+1.6Q=1.4×75+1.6×40=105+64=169kNLoad demand per bolt: Pn=1692=84.5kN

Mechanism detailsFrom characteristic to design load1 concept · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. G is permanent load; Q is imposed load.

    A surface load and a line load also have different units.

  2. This illustration uses the course gravity case .

    Other combinations in the original text retain their own factors.

  3. For illustrative , the separate load contributions show what changes when Q increases.
  4. Do not carry this ULS total automatically into deflection.

    Follow the stated SLS load case.

2. Bolt shear across the single interface

Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Count where the bolt can be sheared

The plate interfaces are the places trying to cut across the bolt.

Count where the bolt can be sheared — The plate interfaces are the places trying to cut across the bolt.

Sketch, not to scale; use the original dimensions.

  1. Count actual loaded shear planes, not merely visible plates.
  2. Choose shank or threaded area for the plane concerned.
  3. Compare group resistance with the force that group transfers.

Remember: Bolts on opposite sides of a splice do not all act in parallel.

Related concept and full method

As is the tensile stress area because no thread-free shear plane is guaranteed.

There is one interface between the angle leg and the support plate, so no factor 2 for double shear.

Ps,one=psAs1,000=375Nmm2×245mm21,000=91.875kNPs,group=2×91.875=183.750kN>169kNPasses.

Mechanism detailsCount the bolt shear planes1 concept · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Load must cross an interface between the connected plates.
  2. A lap joint gives one shear plane through a bolt.
  3. A symmetric double-cover joint may provide two shear planes.

    Count load-transfer interfaces, not just visible plates.

  4. Use the source’s area and shear strength.

    Then check bearing, plate resistance and detailing separately.

3. Bearing of the bolts

Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.

Apply the reasoning to this section’s data and conditions

Physical interpretation: The bolt can crush or tear the plate

A strong bolt can still push through a weak hole edge.

The bolt can crush or tear the plate — A strong bolt can still push through a weak hole edge.

Sketch, not to scale; use the original dimensions.

  1. Check the bolt and each connected plate’s bearing bounds.
  2. Use nominal bolt diameter for bearing; hole size for removed material.
  3. The smallest applicable resistance controls.

Remember: A short end distance may govern even when bolt shear passes.

Related concept and full method

Use the thinner connected thickness tp=min(8,10)=8mm: the angle leg governs.

d=20mm is the bolt diameter, not the 22mm hole.

Pbb,one=dtppbb1,000=20×8×1,0001,000=160kNBolt-group resistance: 2×160=320kN>169kNPasses.

Mechanism detailsBearing and the remaining ligament1 concept · 3 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Force transfers through contact between bolt and connected plate.
  2. The plate around the hole carries bearing stress.

    Bolt bearing and plate bearing are separate checks.

  3. A short ligament can tear out towards the end.

    The direction of force determines the relevant edge.

  4. Evaluate every specified bearing and ligament bound for each layer and retain the smallest applicable resistance.

4. Bearing and ligament resistance of the angle leg

Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.

Apply the reasoning to this section’s data and conditions

The 50mm dimension is centre-to-centre pitch along tension.

Subtract one full hole diameter to get the clear inter-hole ligament lc.

The 45mm dimension is end distance from end to nearest bolt centre.

lc=50−22=28mm;e=45mm;kbs=1B1=1×20×8×5501,000=88kNB2=0.5×1×45×8×5501,000=99kNNet-clearance term between holes: 1.5×28×8×5101,000=171.36kNUpper cap: 2×20×8×8001,000=256kNB3=min(171.36,256)=171.36kNPbs,one=min(88,99,171.36)=88kNTwo bolts together: 2×88=176kN>169kNPasses.

Plate bearing is closer to its limit than bolt shear: 169176=0.9602 utilisation.

This is why the larger bolt-bearing value 320kN cannot be used as the joint’s governing resistance.

Mechanism detailsBearing and the remaining ligament1 concept · 2 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Force transfers through contact between bolt and connected plate.
  2. The plate around the hole carries bearing stress.

    Bolt bearing and plate bearing are separate checks.

  3. A short ligament can tear out towards the end.

    The direction of force determines the relevant edge.

  4. Evaluate every specified bearing and ligament bound for each layer and retain the smallest applicable resistance.

5. Effective angle area and single-leg reduction

Use the same mechanism: One connected leg does not load both legs equally. Keeping the same gross area does not guarantee the same tension resistance when the connection arrangement changes.

Apply the reasoning to this section’s data and conditions

Physical interpretation: One connected leg does not load both legs equally

The connected leg receives the pull first.

The other leg receives it through the angle.

One connected leg does not load both legs equally — The connected leg receives the pull first; the other leg receives it through the angle.

Sketch, not to scale; use the original dimensions.

  1. Identify connected and outstanding legs from the drawing.
  2. Use the relevant bolted or welded angle rule.
  3. Keep the lecturer’s area convention consistent.

Remember: Bolted and welded reduction expressions are not the same rule.

Related concept and full method

Use the lecturer’s rectangular leg-area approximation.

The heel is shared: connected leg width 80−82=76mm; unconnected width 60−82=56mm.

A transverse fracture line crosses one hole, not both bolts arranged along the member.

Apply Ke separately to each leg and cap each at its own gross area.

ag1=76×8=608mm2;a2=ag2=56×8=448mm2Ag=608+448=1,056mm2an1=(76−22)×8=54×8=432mm2an2=448mm2The outstanding angle leg has no hole.ae1=min(1.1×432,608)=475.2mm2ae2=min(1.1×448,448)=min(492.8,448)=448mm2Ae=475.2+448=923.2mm2Pt=py(Ae−0.5a2)1,000=355×(923.2−0.5×448)1,000=355×699.21,000=248.216kN>169kNPasses.

The factor 0.5 belongs specifically to a single bolted angle connected through one leg (Ch 2 p.14).

It is not a generic reduction for all tension members.

Mechanism detailsWhy a connected angle leg matters1 concept · 3 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Locate the connected leg, outstanding leg and centroid before using the table.
  2. Only the connected leg directly receives the fastener force.
  3. The outstanding area may not become equally effective at the same section.

    This motivates the effective-area rule.

  4. Bolted, welded, single-angle and double-angle details can have different rules.

    Preserve the formula attached to the original case.

6. State the governing result and the scope

Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.

Use the same mechanism: One connected leg does not load both legs equally. Keeping the same gross area does not guarantee the same tension resistance when the connection arrangement changes.

Use the same mechanism: A bolt diameter is not a hole diameter. At fixed pitch, a larger hole leaves a shorter clear ligament. Increasing bolt diameter may also increase minimum edge-distance requirements.

Apply the reasoning to this section’s data and conditions

For the requested resistance checks, the minimum is plate bearing 176kN, above 169kN.

The angle tension check also passes.

Units close correctly: stress×mm2 gives N before dividing by 1,000.

The pitch 50mm equals 2.5×20=50mm and is less than min(12×8,150)=96mm.

The end distance 45mm exceeds both supplied M20 minimum values (34 or 26mm).

The transverse edge distances are not fully dimensioned in this example, so these observations do not prove that the entire arrangement has been verified.

Mechanism detailsFollow the calculation sequence5 concepts · 2 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Locate the load, supports, connection geometry and any stated assumptions.
  2. Keep given values, table lookups and calculated values distinct; reconcile their units.
  3. The calculation player steps through the existing expressions in their original order.
  4. Compare demand with resistance or the relevant limit.

    Keep missing inputs and conditional conclusions explicit.

Result and concise exam wording

Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.

Use the same mechanism: One connected leg does not load both legs equally. Keeping the same gross area does not guarantee the same tension resistance when the connection arrangement changes.

Apply the reasoning to this section’s data and conditions

P=169kN.

Two bolts in single shear: Ps=183.75kN; bolt bearing =320kN; angle bearing =min(176,198,342.72)=176kN.

Ae=923.2mm2; single angle Pt=355(923.2−0.5×448)1,000=248.22kN.

All required resistances exceed the demand.

Plate bearing governs, using the two-bolt model specified by the question.

Misconceptions and checks

Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.

Apply the reasoning to this section’s data and conditions

  • Do not multiply by two for shear planes.

    The given joint is single shear.

  • Subtract 22mm for a hole, use 20mm for bearing.
  • Do not multiply the unconnected gross leg area by 1.1 without its gross-area cap.
  • Do not silently replace the written two bolts with four based on the inconsistent sketch.

How the method transfers to a new variant

Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.

Use the same mechanism: Keep load categories separate. Increasing imposed load changes its own term. It does not change the dead-load factor or the steel stiffness.

Apply the reasoning to this section’s data and conditions

  1. Read the written bolt count and the interface geometry; reconcile any discrepancy.
  2. Factor characteristic loads and distribute concentric load to the bolts.
  3. Check shear, bolt bearing and all connected-part bounds.
  4. Compute gross/net/effective leg areas and the correct single/double connection reduction.
  5. Compare each complete load path with the same demand and name the governing one.

Prediction with explained answer

Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.

Use the same mechanism: Test every possible fracture cut. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.

Apply the reasoning to this section’s data and conditions

Prediction and explained answer.

Keep the geometry but increase imposed load to 50kN.

Does the connection still pass the calculated strength checks?

Hint

Recalculate demand only.

The capacities do not change when geometry and materials stay the same.

Answer and reasoning

New P=1.4×75+1.6×50=185kN.

Plate bearing 176kN and bolt shear 183.75kN are both inadequate; angle tension still passes.

A stronger angle alone would not fix the fastener path.

Mechanism detailsCount the bolt shear planes4 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Load must cross an interface between the connected plates.
  2. A lap joint gives one shear plane through a bolt.
  3. A symmetric double-cover joint may provide two shear planes.

    Count load-transfer interfaces, not just visible plates.

  4. Use the source’s area and shear strength.

    Then check bearing, plate resistance and detailing separately.

Mechanism detailsWhy a connected angle leg matters2 concepts · 5 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Locate the connected leg, outstanding leg and centroid before using the table.
  2. Only the connected leg directly receives the fastener force.
  3. The outstanding area may not become equally effective at the same section.

    This motivates the effective-area rule.

  4. Bolted, welded, single-angle and double-angle details can have different rules.

    Preserve the formula attached to the original case.

In-plane eccentric bolts: derive the force distribution

Add force components at each bolt

An in-plane load acts away from the bolt-group centre. Find the largest resultant bolt force.

The direct-force arrows are parallel. The moment-force arrows run tangentially around the bolt-group centre.
The direct-force arrows are parallel. The moment-force arrows run tangentially around the bolt-group centre.

Prediction, then explanation. At fixed force, increasing eccentricity increases the moment component. Its direction differs between bolts.

Locate the bolt-group centre and coordinates. Add horizontal components together and vertical components together before finding each resultant.

M=Pe,J=∑(xi2+yi2),FMx=−Myi/J,FMy=Mxi/JM=Pe,\quad J=\sum(x_i^2+y_i^2),\quad F_{Mx}=-My_i/J,\quad F_{My}=Mx_i/J

e, xi and yi use mm; J uses mm². With M in kN·mm, each moment-force component is in kN.

Scope. These expressions use the stated elastic, equal-bolt in-plane model. Out-of-plane tension and prying require another model.

Check and takeaway. Do not add force magnitudes before resolving directions. Two perpendicular forces of 3 and 4 kN give 5 kN, not 7 kN.

Apply the reasoning to this section’s data and conditions

Physical interpretation: An off-centre force also tries to turn the group

Pulling away from the centre causes a push plus a twist.

An off-centre force also tries to turn the group — Pulling away from the centre causes a push plus a twist.

Sketch, not to scale; use the original dimensions.

  1. Find direct shear and moment about the bolt-group centroid.
  2. Moment-induced forces act tangentially; farther bolts attract more.
  3. Add horizontal and vertical components before finding the resultant.

Remember: Do not simply add two force magnitudes pointing in different directions.

Related concept and full method

Source: Chapter 2 pp.21–22.

The eccentric force tries to rotate the bolt group in the plane of the plate.

Assume a rigid plate, equal bolts, elastic force proportional to radius and uniform direct shear.

Place the origin at the bolt-group centroid.

Give every bolt coordinates xi, yi measured in mm, with ri2=xi2+yi2.

Jbolts=Σri2=Σxi2+Σyi2Units: mm2. M=PeUnits: kN·mm. FT,i=MriJbolts;Fs=PnBoth have units kN.

Why this works: if torsional force is Cri, its resisting moment is Cri2.

Summing gives M=CΣr2, so C=MJ.

The torsional force is tangent to a circle, perpendicular to the radius, not radial.

For vertical applied load, its vertical component at a critical corner is MxJ and horizontal component MyJ.

Choose the corner where the vertical component adds to direct shear.

FR=(Pn+M|x|J)2+(M|y|J)2

This is equivalent to the lecture vector formula Fs2+FT2+2FsFTcosφ, with cosφ=|x|r for the shown vertical-load arrangement.

Do not use |y|r merely because the load is vertical: torsional force is perpendicular to the radius.

Connection example 3: an eccentric bolt group in the plate plane

Check the Grade 8.8 M24 bolt group carrying 100kN dead plus 130kN imposed load at a 525mm eccentricity. Steel is S355. Use the lecturer’s one-side-plate load model.

Original source: LectureNotes/Ch 2_Connection.pdf — p. 25, p. 26.

A given value comes from the question or diagram.

A lookup value comes from the named table.

A calculated value follows from the working.

Each assumption is stated where the calculation needs it.

Known information, diagram labels and unknowns

Use the same mechanism: Add force components at each bolt. At fixed force, increasing eccentricity increases the moment component. Its direction differs between bolts.

Use the same mechanism: A bolt diameter is not a hole diameter. At fixed pitch, a larger hole leaves a shorter clear ligament. Increasing bolt diameter may also increase minimum edge-distance requirements.

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

InputOrigin
Given load/model

100kN dead+130kN imposed.

Drawing says bolt loads shown on one plate.

Do not halve the specified force again.

Given e525mm horizontal distance from the dashed bolt-group centreline to vertical load line, upper dimension.
Coordinates

x=±250mm from the two 250 dimensions.

y=±35,±105,±175mm from 70mm pitch and symmetric six-row arrangement.

Thickness and edge

Side plate 15mm; p.26 gives UC flange 17.3mm, so tp=15.

Vertical end 45mm; pitch 70; hole 26mm.

LookupM24 As=353mm2; ps=375,pbb=1,000,pbs=550,Us=510,Ub=800Nmm2.

Why this method applies

Use the same mechanism: Add force components at each bolt. At fixed force, increasing eccentricity increases the moment component. Its direction differs between bolts.

Use the same mechanism: Test every possible fracture cut. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.

Apply the reasoning to this section’s data and conditions

The load rotates the plate in its own plane.

Therefore, each bolt takes uniform direct shear plus tangential torsional shear.

This is not a bolt-tension problem.

Use centroidal coordinates, sum squared distances over all 12 bolts, and resolve torsional force into components before adding direct shear.

The far right corners have torsional vertical force in the same direction as direct shear.

1. Factored load and moment

Use the same mechanism: Keep load categories separate. Increasing imposed load changes its own term. It does not change the dead-load factor or the steel stiffness.

Use the same mechanism: Add force components at each bolt. At fixed force, increasing eccentricity increases the moment component. Its direction differs between bolts.

Apply the reasoning to this section’s data and conditions

P=1.4×100+1.6×130=140+208=348kNM=Pe=348kN×525mm=182,700kN·mm=182.7kN·m

Mechanism detailsFrom characteristic to design load2 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. G is permanent load; Q is imposed load.

    A surface load and a line load also have different units.

  2. This illustration uses the course gravity case .

    Other combinations in the original text retain their own factors.

  3. For illustrative , the separate load contributions show what changes when Q increases.
  4. Do not carry this ULS total automatically into deflection.

    Follow the stated SLS load case.

2. Bolt-group polar sum and corner radius

Use the same mechanism: Add force components at each bolt. At fixed force, increasing eccentricity increases the moment component. Its direction differs between bolts.

Apply the reasoning to this section’s data and conditions

Physical interpretation: An off-centre force also tries to turn the group

Pulling away from the centre causes a push plus a twist.

An off-centre force also tries to turn the group — Pulling away from the centre causes a push plus a twist.

Sketch, not to scale; use the original dimensions.

  1. Find direct shear and moment about the bolt-group centroid.
  2. Moment-induced forces act tangentially; farther bolts attract more.
  3. Add horizontal and vertical components before finding the resultant.

Remember: Do not simply add two force magnitudes pointing in different directions.

Related concept and full method

Each bolt contributes x2+y2.

There are 12 identical |x| values.

At each absolute height 35, 105, 175mm there are four bolts: two left/right positions multiplied by two positive/negative vertical positions.

Σx2=12×2502=12×62,500=750,000mm2Σy2=4(352+1052+1752)=4(1,225+11,025+30,625)=171,500mm2J=750,000+171,500=921,500mm2rA=2502+1752=93,125=305.164mmcosφ=250305.164=0.819232

Mechanism detailsAdd direct and torsional bolt forces1 concept · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Assign signed coordinates to the bolts relative to the group centroid.
  2. For the equal-bolt elastic model, the direct force is per bolt.
  3. Moment magnitude is .

    Its sign follows the load direction.

    For signed M: , , .

  4. Add signed x and y components at each bolt, then take the resultant.

    The longest arrow shows the critical bolt in this illustration.

3. Direct force, torsion and maximum resultant

Use the same mechanism: Add force components at each bolt. At fixed force, increasing eccentricity increases the moment component. Its direction differs between bolts.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Add arrows before taking the magnitude

Walking east and walking north do not point in the same direction.

Add arrows before taking the magnitude — Walking east and walking north do not point in the same direction.

Sketch, not to scale; use the original dimensions.

  1. Choose signed horizontal and vertical directions.
  2. Add contributions along each direction separately.
  3. For perpendicular components, use the right-triangle resultant.

Remember: Check the corner where direct and torsional components reinforce each other.

Related concept and full method

Direct shear per bolt: Fs=P12=34812=29kNFT,A=MrJ=182,700×305.164921,500=60.503kNVertical torsional-force component: M×250J=49.566kNHorizontal torsional-force component: M×175J=34.696kNFR,A=(29+49.566)2+34.6962=85.886kN

The units of MrJ are (kN·mm)×mmmm2=kN.

The top/bottom right corners have equal resultant magnitude.

Other rows have a smaller horizontal torsion component.

The left column’s vertical torsion subtracts from direct shear, so it is less critical.

Mechanism detailsAdd direct and torsional bolt forces1 concept · 2 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Assign signed coordinates to the bolts relative to the group centroid.
  2. For the equal-bolt elastic model, the direct force is per bolt.
  3. Moment magnitude is .

    Its sign follows the load direction.

    For signed M: , , .

  4. Add signed x and y components at each bolt, then take the resultant.

    The longest arrow shows the critical bolt in this illustration.

4. Compare with single-shear bolt resistance

Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Apply the reasoning to this section’s data and conditions

Ps=375×3531,000=132.375kN>85.886kNPasses.

The source checks the side plate’s single shear interface.

The plan view showing plates on both sides does not authorise doubling resistance while keeping only one side’s force model.

Mechanism detailsCount the bolt shear planes1 concept · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Load must cross an interface between the connected plates.
  2. A lap joint gives one shear plane through a bolt.
  3. A symmetric double-cover joint may provide two shear planes.

    Count load-transfer interfaces, not just visible plates.

  4. Use the source’s area and shear strength.

    Then check bearing, plate resistance and detailing separately.

5. Check bolt bearing against the same resultant

Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.

Apply the reasoning to this section’s data and conditions

tp=min(15,17.3)=15mmPbb=24×15×1,0001,000=360kN>85.886kNPasses.

Mechanism detailsBearing and the remaining ligament1 concept · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Force transfers through contact between bolt and connected plate.
  2. The plate around the hole carries bearing stress.

    Bolt bearing and plate bearing are separate checks.

  3. A short ligament can tear out towards the end.

    The direction of force determines the relevant edge.

  4. Evaluate every specified bearing and ligament bound for each layer and retain the smallest applicable resistance.

6. Connected-part bounds and conclusion

Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.

Use the same mechanism: Add force components at each bolt. At fixed force, increasing eccentricity increases the moment component. Its direction differs between bolts.

Apply the reasoning to this section’s data and conditions

Physical interpretation: The bolt can crush or tear the plate

A strong bolt can still push through a weak hole edge.

The bolt can crush or tear the plate — A strong bolt can still push through a weak hole edge.

Sketch, not to scale; use the original dimensions.

  1. Check the bolt and each connected plate’s bearing bounds.
  2. Use nominal bolt diameter for bearing; hole size for removed material.
  3. The smallest applicable resistance controls.

Remember: A short end distance may govern even when bolt shear passes.

Related concept and full method

lc=70−26=44mmB1=1×24×15×5501,000=198kNB2=0.5×1×45×15×5501,000=185.625kNNet-clearance term between holes: 1.5×44×15×5101,000=504.9kNUpper cap: 2×24×15×8001,000=576kNPbs=min(198,185.625,504.9,576)=185.625kN>85.886Passes.

For the course’s specified connection checks, single-shear bolt capacity 132.375kN is the governing resistance per critical bolt.

The ratio 85.886132.375≈0.649.

This is not a total connection force capacity of 132.375kN: it is compared with the critical bolt force.

Mechanism detailsBearing and the remaining ligament2 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Force transfers through contact between bolt and connected plate.
  2. The plate around the hole carries bearing stress.

    Bolt bearing and plate bearing are separate checks.

  3. A short ligament can tear out towards the end.

    The direction of force determines the relevant edge.

  4. Evaluate every specified bearing and ligament bound for each layer and retain the smallest applicable resistance.

Result and concise exam wording

Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.

Apply the reasoning to this section’s data and conditions

P=348kN, M=182.7kN·m.

J=921,500mm2; r=305.164mm.

Fs=29kN, FT=60.503kN; FR,max=85.886kN.

Per-bolt resistances: shear 132.375kN, bolt bearing 360kN, plate bearing 185.625kN.

All exceed the resultant; requested checks pass.

Misconceptions and checks

Treat a weld group as lines

An eccentric force creates direct line force and torsional line force in the same weld group.

The four perimeter lines represent weld runs. The interior label says No weld here: the enclosed plate area is not weld length.
The four perimeter lines represent weld runs. The interior label says No weld here: the enclosed plate area is not weld length.

Prediction, then explanation. Increasing eccentricity increases the torsional contribution. The governing corner depends on vector addition, not distance alone.

Find the line centroid. Integrate squared distance along the effective lines. Add direct and torsional components at every candidate critical point.

J=∫r2 dl,qMx=−My/J,qMy=Mx/JJ=\int r^2\,dl,\qquad q_{Mx}=-My/J,\quad q_{My}=Mx/J

J is line polar inertia in mm³. x and y use mm. With M in kN·mm, q is line force in kN/mm.

Scope. A solid rectangle has area inertia in mm⁴ and is not this weld-line model. Missing weld sides change the centroid and integrals.

Check and takeaway. Compare the largest resultant line force with the selected throat resistance. Keep kN/mm distinct from total force in kN.

Use the same mechanism: Add force components at each bolt. At fixed force, increasing eccentricity increases the moment component. Its direction differs between bolts.

Use the same mechanism: Change the ruler, keep the quantity. Would every property increase by ten? No. The exponent determines how many factors of ten are needed.

Apply the reasoning to this section’s data and conditions

  • Do not use P12 as the complete bolt demand.
  • The sum for bolt-group geometry has units mm2, unlike weld line inertia mm3.
  • The 525mm eccentricity starts at the group centroid, not the right bolt column.
  • Add force components.

    Fs+FT is not the actual resultant.

How the method transfers to a new variant

Use the same mechanism: Add force components at each bolt. At fixed force, increasing eccentricity increases the moment component. Its direction differs between bolts.

Use the same mechanism: Keep load categories separate. Increasing imposed load changes its own term. It does not change the dead-load factor or the steel stiffness.

Apply the reasoning to this section’s data and conditions

  1. Locate centroid and write every bolt coordinate.
  2. Compute factored P, centroidal eccentricity e and M.
  3. Sum all r2 and resolve MrJ into components.
  4. Find the corner where torsion adds to direct shear.
  5. Compare that resultant with shear and all bearing limits.

Prediction with explained answer

Use the same mechanism: Add force components at each bolt. At fixed force, increasing eccentricity increases the moment component. Its direction differs between bolts.

Use the same mechanism: Keep load categories separate. Increasing imposed load changes its own term. It does not change the dead-load factor or the steel stiffness.

Apply the reasoning to this section’s data and conditions

Prediction and explained answer.

If both characteristic loads increase by 20% with unchanged geometry, how does the critical bolt force change?

Answer and reasoning

P and M each multiply by 1.2; every direct/torsional component does too.

FR=1.2×85.886=103.063kN, still below 132.375kN.

Capacity is unchanged.

Mechanism detailsAdd direct and torsional bolt forces1 concept · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Assign signed coordinates to the bolts relative to the group centroid.
  2. For the equal-bolt elastic model, the direct force is per bolt.
  3. Moment magnitude is .

    Its sign follows the load direction.

    For signed M: , , .

  4. Add signed x and y components at each bolt, then take the resultant.

    The longest arrow shows the critical bolt in this illustration.

Mechanism detailsAdd direct and torsional bolt forces1 concept · 6 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Assign signed coordinates to the bolts relative to the group centroid.
  2. For the equal-bolt elastic model, the direct force is per bolt.
  3. Moment magnitude is .

    Its sign follows the load direction.

    For signed M: , , .

  4. Add signed x and y components at each bolt, then take the resultant.

    The longest arrow shows the critical bolt in this illustration.

Out-of-plane brackets: shear plus tension

Use the same mechanism: An eccentric bracket pulls bolts differently. For unchanged geometry, doubling the applied moment doubles the modelled bolt tensions. Changing the pivot changes the distribution.

Two simultaneous actions use one component

Check a component that carries shear and tension, or compression and bending, at the same time.

The bolt receives two labelled arrows: tension and shear. The caption requires both individual checks and the combined check.
The bolt receives two labelled arrows: tension and shear. The caption requires both individual checks and the combined check.

Prediction, then explanation. At fixed resistances, increasing one demand increases its utilisation. The permitted sum is not always one.

First apply the individual checks. Next use the exact combined equation and its definitions. Keep demands from the same load case.

FsPs+FtPnom≤1.4\frac{F_s}{P_s}+\frac{F_t}{P_{nom}}\le1.4

This is the course bolt interaction rule. Fs and Ft are bolt demands; Ps and Pnom are their specified resistance denominators.

Scope. The 1.4 limit and nominal tension denominator do not apply to column equations. Their limits and moment definitions are separate.

Check and takeaway. A sum above one can pass this bolt rule while still needing individual checks. A pass must name the actual equation used.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Two passing checks may still interact

One bolt is doing two jobs at the same time.

Two passing checks may still interact — One bolt is doing two jobs at the same time.

Sketch, not to scale; use the original dimensions.

  1. Check shear on its own and tension on its own.
  2. Calculate the course’s combined-action expression.
  3. Apply its own limit, not a limit borrowed from columns.

Remember: The supplied bolt interaction limit of 1.4 does not replace the individual checks.

Related concept and full method

Source: Chapter 2 pp.23–24.

Here the bracket pulls the plate away from the support and rotates about a bottom contact/bolt line in the lecture approximation.

Measure each bolt-row distance y from that assumed rotation line.

The bottom row has y=0 and no moment-induced tension in this model, but still carries direct shear.

Jrows=Σ(distances of all boltsy2)Units: mm2. FT,max=PeymaxJrowsFs=PnCheck simultaneously: Fs≤Ps;FT,max≤PnomFsPs+FT,maxPnom≤1.4

For two identical vertical rows of bolts, J=2Σy2 for one row.

Do not multiply by 2 again when the sum already includes both rows.

The individual limits remain compulsory: a sum below 1.4 alone does not excuse excessive tension or shear.

Bearing also needs checking where the connection data permit it.

Connection example 4: bracket bolts in shear and tension

Check ten Grade 8.8 M16 bolts supporting a 250kN ultimate bracket load at 200mm eccentricity. Five bolts are arranged vertically on each side at 90mm centres. Steel is S355.

Original source: LectureNotes/Ch 2_Connection.pdf — p. 27, p. 28.

A given value comes from the question or diagram.

A lookup value comes from the named table.

A calculated value follows from the working.

Each assumption is stated where the calculation needs it.

Known information, diagram labels and unknowns

Use the same mechanism: An eccentric bracket pulls bolts differently. For unchanged geometry, doubling the applied moment doubles the modelled bolt tensions. Changing the pivot changes the distribution.

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

InputOrigin
Given load

250kN ultimate.

The downward arrow is outside the connection plane.

Given bolt arrangementFive bolts per side; two sides;90mm between consecutive rows; total 10.
Calculated row distancesOn each side, measure upwards from the bottom rotation line: 0,90,180,270,360mm.
LookupM16 As=157mm2, Grade 8.8 ps=375 and pt=560Nmm2 (Ch 2 pp.3,9–10).
Model assumption

Rigid bracket and linear tensile-force distribution about bottom bolt line, as stated in the lecturer approximation.

Use nominal tension 0.8Aspt.

Why this method applies

Use the same mechanism: Add force components at each bolt. At fixed force, increasing eccentricity increases the moment component. Its direction differs between bolts.

Use the same mechanism: An eccentric bracket pulls bolts differently. For unchanged geometry, doubling the applied moment doubles the modelled bolt tensions. Changing the pivot changes the distribution.

Use the same mechanism: Test every possible fracture cut. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.

Apply the reasoning to this section’s data and conditions

The load pulls the upper bolts along their axes while all bolts carry vertical shear.

Use an out-of-plane rotation model, not the centroidal in-plane torsion formula.

Check shear, tension and their interaction separately.

The task’s bolt calculation does not provide the full plate/gauge dimensions needed for a complete joint/prying and bearing verification.

1. Find bolt shear and nominal tension resistance

Use the same mechanism: An eccentric bracket pulls bolts differently. For unchanged geometry, doubling the applied moment doubles the modelled bolt tensions. Changing the pivot changes the distribution.

Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Apply the reasoning to this section’s data and conditions

Ps=375×1571,000=58.875kNPt=560×1571,000=87.92kNPnom=0.8×87.92=70.336kN

The 0.8 reduction is part of the adopted simplified model.

Do not substitute 87.92 in the nominal-tension interaction denominator.

Mechanism detailsOut-of-plane bolt tension and prying2 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. A bracket moment can create compression at the plate contact and tension in the bolt rows.
  2. The original assumed pivot/compression line determines each row distance.
  3. Under the elastic row model, a farther tension row attracts more tension.

    Direct shear may act simultaneously.

  4. Flexible plates can add prying force.

    Use nominal tension and interaction rules exactly as specified by the course.

2. Sum squared distances about the bottom row

Use the same mechanism: An eccentric bracket pulls bolts differently. For unchanged geometry, doubling the applied moment doubles the modelled bolt tensions. Changing the pivot changes the distribution.

Apply the reasoning to this section’s data and conditions

Each of the two vertical sides has the same distances.

The bottom row contributes 02 to moment resistance but remains in the count for direct shear.

Jrows=2(02+902+1802+2702+3602)=2(0+8,100+32,400+72,900+129,600)=2×243,000=486,000mm2M=Pe=250×200=50,000kN·mm

Mechanism detailsOut-of-plane bolt tension and prying1 concept · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. A bracket moment can create compression at the plate contact and tension in the bolt rows.
  2. The original assumed pivot/compression line determines each row distance.
  3. Under the elastic row model, a farther tension row attracts more tension.

    Direct shear may act simultaneously.

  4. Flexible plates can add prying force.

    Use nominal tension and interaction rules exactly as specified by the course.

3. Maximum tension is in the top row

Use the same mechanism: An eccentric bracket pulls bolts differently. For unchanged geometry, doubling the applied moment doubles the modelled bolt tensions. Changing the pivot changes the distribution.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Why the top bolt row is pulled hardest

The bracket tries to peel away from the support about the assumed contact line.

Why the top bolt row is pulled hardest — The bracket tries to peel away from the support about the assumed contact line.

Sketch, not to scale; use the original dimensions.

  1. Use the rotation/contact line assumed by the course model.
  2. Measure each bolt row’s distance from that line.
  3. Check maximum tension, direct shear and their interaction.

Remember: A row at the pivot can still carry direct shear.

Related concept and full method

Tension varies in proportion to distance y.

Let Fi=Cyi; moment equilibrium gives M=CΣy2.

Thus C=MJ and the top bolt at y=360mm has the largest tension.

FT,max=50,000×360486,000=37.037kN37.037<70.336kN: individual tension check passes.

Mechanism detailsOut-of-plane bolt tension and prying1 concept · 5 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. A bracket moment can create compression at the plate contact and tension in the bolt rows.
  2. The original assumed pivot/compression line determines each row distance.
  3. Under the elastic row model, a farther tension row attracts more tension.

    Direct shear may act simultaneously.

  4. Flexible plates can add prying force.

    Use nominal tension and interaction rules exactly as specified by the course.

4. Uniform direct shear

Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Apply the reasoning to this section’s data and conditions

Fs=Pn=25010=25kN25<58.875kN: individual shear check passes.

Mechanism detailsCount the bolt shear planes1 concept · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Load must cross an interface between the connected plates.
  2. A lap joint gives one shear plane through a bolt.
  3. A symmetric double-cover joint may provide two shear planes.

    Count load-transfer interfaces, not just visible plates.

  4. Use the source’s area and shear strength.

    Then check bearing, plate resistance and detailing separately.

5. Combined action and conclusion

Use the same mechanism: An eccentric bracket pulls bolts differently. For unchanged geometry, doubling the applied moment doubles the modelled bolt tensions. Changing the pivot changes the distribution.

Use the same mechanism: Two simultaneous actions use one component. At fixed resistances, increasing one demand increases its utilisation. The permitted sum is not always one.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Two passing checks may still interact

One bolt is doing two jobs at the same time.

Two passing checks may still interact — One bolt is doing two jobs at the same time.

Sketch, not to scale; use the original dimensions.

  1. Check shear on its own and tension on its own.
  2. Calculate the course’s combined-action expression.
  3. Apply its own limit, not a limit borrowed from columns.

Remember: The supplied bolt interaction limit of 1.4 does not replace the individual checks.

Related concept and full method

FsPs+FTPnom=2558.875+37.03770.336=0.424628+0.526573=0.951201≤1.4Passes.

The bolts satisfy all three calculated shear/tension conditions under the lecturer’s approximate model.

This is the requested bolt result.

The source does not give sufficient plate thickness, bearing-edge geometry or flange gauge.

Therefore the result does not establish the other joint limit states.

Mechanism detailsOut-of-plane bolt tension and prying2 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. A bracket moment can create compression at the plate contact and tension in the bolt rows.
  2. The original assumed pivot/compression line determines each row distance.
  3. Under the elastic row model, a farther tension row attracts more tension.

    Direct shear may act simultaneously.

  4. Flexible plates can add prying force.

    Use nominal tension and interaction rules exactly as specified by the course.

Result and concise exam wording

Use the same mechanism: Two simultaneous actions use one component. At fixed resistances, increasing one demand increases its utilisation. The permitted sum is not always one.

Apply the reasoning to this section’s data and conditions

Ps=58.875kN; Pnom=70.336kN.

Σy2=486,000mm2 about bottom bolt line.

FT,max=250×200×360486,000=37.037kN.

Fs=25kN.

Individual limits pass and interaction=0.9512<1.4.

Bolts are adequate under the specified approximate shear/tension model.

Misconceptions and checks

Use the same mechanism: Two simultaneous actions use one component. At fixed resistances, increasing one demand increases its utilisation. The permitted sum is not always one.

Apply the reasoning to this section’s data and conditions

  • Do not factor 250kN again.
  • Do not measure y from the group centroid for this bottom-pivot model.
  • Do not omit the bottom bolts from direct shear.
  • Passing the 1.4 interaction does not replace individual shear/tension limits.

How the method transfers to a new variant

Use the same mechanism: An eccentric bracket pulls bolts differently. For unchanged geometry, doubling the applied moment doubles the modelled bolt tensions. Changing the pivot changes the distribution.

Use the same mechanism: Test every possible fracture cut. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.

Use the same mechanism: Two simultaneous actions use one component. At fixed resistances, increasing one demand increases its utilisation. The permitted sum is not always one.

Apply the reasoning to this section’s data and conditions

  1. Identify out-of-plane rotation and the stated pivot.
  2. Write all y distances and include all physical bolts in Σy2.
  3. Calculate maximum tension and uniform shear.
  4. Check each individual resistance and then the interaction.
  5. State the model and any unprovided plate/prying information.

Prediction with explained answer

Use the same mechanism: Add force components at each bolt. At fixed force, increasing eccentricity increases the moment component. Its direction differs between bolts.

Use the same mechanism: Two simultaneous actions use one component. At fixed resistances, increasing one demand increases its utilisation. The permitted sum is not always one.

Apply the reasoning to this section’s data and conditions

Prediction and explained answer.

Move the same load to 400mm eccentricity.

Does the existing bolt group pass?

Answer and reasoning

Tension doubles to 74.074kN, exceeding 70.336.

Interaction becomes 2558.875+74.07470.336≈1.478>1.4.

Both tension and interaction fail; shear remains 25kN.

Mechanism detailsOut-of-plane bolt tension and prying2 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. A bracket moment can create compression at the plate contact and tension in the bolt rows.
  2. The original assumed pivot/compression line determines each row distance.
  3. Under the elastic row model, a farther tension row attracts more tension.

    Direct shear may act simultaneously.

  4. Flexible plates can add prying force.

    Use nominal tension and interaction rules exactly as specified by the course.

Connection example 5: separate moment and shear bolt groups

Design the bolt groups joining a 610×229×140 UB floor beam to a 254×254×132 UC. Steel is S355 and bolts are Grade 8.8 M24. Characteristic moments are 160kN·m dead and 90kN·m imposed; characteristic shears are 250kN dead and 160kN imposed.

Original source: LectureNotes/Ch 2_Connection.pdf — p. 29, p. 30.

A given value comes from the question or diagram.

A lookup value comes from the named table.

A calculated value follows from the working.

Each assumption is stated where the calculation needs it.

Known information, diagram labels and unknowns

A force couple carries moment

Separate the force couple used to carry moment from the force used to carry web shear.

The flange forces act in opposite directions. Their separation z gives the lever arm. The web arrow represents shear.
The flange forces act in opposite directions. Their separation z gives the lever arm. The web arrow represents shear.

Prediction, then explanation. For the same moment, a larger lever arm requires a smaller couple force. It does not remove the web shear.

Moment is force multiplied by perpendicular separation. Divide the required moment by the specified separation to obtain each couple force.

F=M/zF=M/z

M is moment in kN·mm; z is the specified force-line separation in mm; F is force in kN.

Scope. Use the lever arm defined by the source model. Do not silently replace it with overall section depth or another geometric distance.

Check and takeaway. Check flange welds for the couple forces and web welds for the stated shear model. Both force paths need a satisfactory detail.

Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.

Use the same mechanism: A bolt diameter is not a hole diameter. At fixed pitch, a larger hole leaves a shorter clear ligament. Increasing bolt diameter may also increase minimum edge-distance requirements.

Apply the reasoning to this section’s data and conditions

InputOrigin
Given actionsSeparate moment and shear dead/imposed components in question table; factor each once.
Given force-couple arm595mm between flange force lines in lecturer diagram/solution; not the nominal 610mm beam depth.
Selected fastenersFour upper flange bolts; four lower for opposite moment direction; eight web bolts, all M24.
Selected bearing detail

Lecturer p.30 selects 12mm end plate,55mm end distance and 70mm pitch.

These are design choices, not task givens.

LookupM24 As=353mm2; Grade 8.8 pt=560,ps=375,pbb=1,000; S355 pbs=550,Us=510; Ub=800Nmm2.

Why this method applies

Use the same mechanism: Add force components at each bolt. At fixed force, increasing eccentricity increases the moment component. Its direction differs between bolts.

Use the same mechanism: A force couple carries moment. For the same moment, a larger lever arm requires a smaller couple force. It does not remove the web shear.

Apply the reasoning to this section’s data and conditions

Use the source idealisation: bending is a tension/compression force couple at the flanges; vertical shear is carried by a separate web-bolt group.

Moment divided by the perpendicular couple arm gives flange force.

Because groups have separate assigned actions, do not distribute the flange tensile force among the web bolts.

1. Design the tension flange group

Use the same mechanism: An eccentric bracket pulls bolts differently. For unchanged geometry, doubling the applied moment doubles the modelled bolt tensions. Changing the pivot changes the distribution.

Use the same mechanism: A force couple carries moment. For the same moment, a larger lever arm requires a smaller couple force. It does not remove the web shear.

Apply the reasoning to this section’s data and conditions

Physical interpretation: How two flange forces make a moment

Two opposite forces form a turning pair, like two hands turning a wheel.

How two flange forces make a moment — Two opposite forces form a turning pair, like two hands turning a wheel.

Sketch, not to scale; use the original dimensions.

  1. Identify the separation between their actual force lines.
  2. Required force equals moment divided by that separation.
  3. Design the relevant flange group for that force.

Remember: The force-line separation is not automatically the overall section depth.

Related concept and full method

M=1.4×160+1.6×90=224+144=368kN·mFflange=Mz=3680.595=618.487kNPnom,one=0.8×560×3531,000=158.144kNn≥618.487158.144=3.911→select4Nominal tension resistance of the whole group: Pnom=4×158.144=632.576kN>618.487Passes.

For the moment direction shown, the lower flange region supplies compression and the upper group tension.

The extra lower four bolts are not added to the upper group’s capacity; they provide the corresponding group for the opposite moment direction/detail.

Mechanism detailsOut-of-plane bolt tension and prying2 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. A bracket moment can create compression at the plate contact and tension in the bolt rows.
  2. The original assumed pivot/compression line determines each row distance.
  3. Under the elastic row model, a farther tension row attracts more tension.

    Direct shear may act simultaneously.

  4. Flexible plates can add prying force.

    Use nominal tension and interaction rules exactly as specified by the course.

2. Design the shear group

Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Use the same mechanism: A force couple carries moment. For the same moment, a larger lever arm requires a smaller couple force. It does not remove the web shear.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Count where the bolt can be sheared

The plate interfaces are the places trying to cut across the bolt.

Count where the bolt can be sheared — The plate interfaces are the places trying to cut across the bolt.

Sketch, not to scale; use the original dimensions.

  1. Count actual loaded shear planes, not merely visible plates.
  2. Choose shank or threaded area for the plane concerned.
  3. Compare group resistance with the force that group transfers.

Remember: Bolts on opposite sides of a splice do not all act in parallel.

Related concept and full method

V=1.4×250+1.6×160=350+256=606kNPs,one=375×3531,000=132.375kNFor 8 web bolts, demand per bolt: 6068=75.75kNPs,group=8×132.375=1,059.0kN>606Passes.

Mechanism detailsCount the bolt shear planes2 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Load must cross an interface between the connected plates.
  2. A lap joint gives one shear plane through a bolt.
  3. A symmetric double-cover joint may provide two shear planes.

    Count load-transfer interfaces, not just visible plates.

  4. Use the source’s area and shear strength.

    Then check bearing, plate resistance and detailing separately.

3. Check selected end-plate bearing

Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.

Apply the reasoning to this section’s data and conditions

Use d=24mm and standard hole d0=26mm.

The chosen 12mm plate and 70mm pitch give clear ligament 44mm.

The chosen end distance is 55mm.

Pbb=24×12×1,0001,000=288kNlc=70−26=44mmB1=24×12×5501,000=158.4kNB2=0.5×55×12×5501,000=181.5kNNet-clearance term between holes: 1.5×44×12×5101,000=403.92kNUpper cap: 2×24×12×8001,000=460.8kNPbs=min(158.4,181.5,403.92,460.8)=158.4kN

Both bearing resistances exceed the 75.75kN per-bolt demand and also exceed the 132.375kN shear resistance, so shear governs the web group.

Mechanism detailsBearing and the remaining ligament1 concept · 3 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Force transfers through contact between bolt and connected plate.
  2. The plate around the hole carries bearing stress.

    Bolt bearing and plate bearing are separate checks.

  3. A short ligament can tear out towards the end.

    The direction of force determines the relevant edge.

  4. Evaluate every specified bearing and ligament bound for each layer and retain the smallest applicable resistance.

4. State what has actually been designed

Use the same mechanism: A force couple carries moment. For the same moment, a larger lever arm requires a smaller couple force. It does not remove the web shear.

Use the same mechanism: An eccentric bracket pulls bolts differently. For unchanged geometry, doubling the applied moment doubles the modelled bolt tensions. Changing the pivot changes the distribution.

Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Apply the reasoning to this section’s data and conditions

Physical interpretation: What to do when one input is missing

A calculator cannot supply a dimension that the drawing never gave.

What to do when one input is missing — A calculator cannot supply a dimension that the drawing never gave.

Sketch, not to scale; use the original dimensions.

  1. Separate given values, table values and calculated values.
  2. Complete the checks whose required inputs are available.
  3. State the missing input beside the remaining conditional result.

Remember: An illustrative assumption must not become an unstated exam given.

Related concept and full method

The flange tension and web shear/bearing bolt checks pass under the source’s force-couple idealisation.

The source explicitly says only bolts have been designed; welds, end plates, stiffeners, column flange and column web require separate design.

The 12mm end-plate bearing calculation is not a complete end-plate bending/prying check.

Mechanism detailsSeparate the moment couple and shear5 concepts

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. A simplified moment connection assigns different actions to different fastener groups.
  2. Opposite flange forces separated by z resist moment: .
  3. The web fasteners or welds carry the assigned vertical shear in this model.
  4. Flange force, web shear, plate bearing and detailing each need their specified checks.

Result and concise exam wording

Use the same mechanism: An eccentric bracket pulls bolts differently. For unchanged geometry, doubling the applied moment doubles the modelled bolt tensions. Changing the pivot changes the distribution.

Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.

Use the same mechanism: Test every possible fracture cut. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.

Apply the reasoning to this section’s data and conditions

ULS M=368kN·m; flange force=618.487kN.

Four M24 Grade 8.8 flange bolts give nominal tension 632.576kN.

ULS V=606kN; eight M24 web bolts give shear 1,059.0kN.

Selected 12mm plate gives bolt bearing 288kN and plate bearing 158.4kN per bolt, both>75.75kN.

Bolts pass; remaining connection components are outside the source calculation.

Misconceptions and checks

Use the same mechanism: A force couple carries moment. For the same moment, a larger lever arm requires a smaller couple force. It does not remove the web shear.

Use the same mechanism: Test every possible fracture cut. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.

Apply the reasoning to this section’s data and conditions

  • Use 595mm force-couple arm, not nominal beam depth 610mm.
  • Do not add bottom compression-side bolts to the upper tensile group.
  • Do not call the end plate fully designed after checking only bearing.

How the method transfers to a new variant

Use the same mechanism: A force couple carries moment. For the same moment, a larger lever arm requires a smaller couple force. It does not remove the web shear.

Use the same mechanism: An eccentric bracket pulls bolts differently. For unchanged geometry, doubling the applied moment doubles the modelled bolt tensions. Changing the pivot changes the distribution.

Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.

Apply the reasoning to this section’s data and conditions

  1. Factor moment and shear components separately.
  2. Resolve bending moment into flange force using the stated couple arm.
  3. Size the tension group using nominal bolt tension.
  4. Assign shear to the web group and check its bearing path.
  5. Document which other joint components are not included in the bolt-only exercise.

Prediction with explained answer

Use the same mechanism: An eccentric bracket pulls bolts differently. For unchanged geometry, doubling the applied moment doubles the modelled bolt tensions. Changing the pivot changes the distribution.

Use the same mechanism: Test every possible fracture cut. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.

Apply the reasoning to this section’s data and conditions

Prediction and explained answer.

If the ultimate moment becomes 400kN·m, keeping 595mm arm and four flange bolts, is the tension group adequate?

Answer and reasoning

F=4000.595=672.269kN>632.576kN, so no.

Required count≥672.269158.144=4.251; at least 5 by strength alone.

However, the final symmetric layout and plate/prying design must also be revised.

Mechanism detailsOut-of-plane bolt tension and prying1 concept · 2 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. A bracket moment can create compression at the plate contact and tension in the bolt rows.
  2. The original assumed pivot/compression line determines each row distance.
  3. Under the elastic row model, a farther tension row attracts more tension.

    Direct shear may act simultaneously.

  4. Flexible plates can add prying force.

    Use nominal tension and interaction rules exactly as specified by the course.

Mechanism detailsOut-of-plane bolt tension and prying2 concepts · 3 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. A bracket moment can create compression at the plate contact and tension in the bolt rows.
  2. The original assumed pivot/compression line determines each row distance.
  3. Under the elastic row model, a farther tension row attracts more tension.

    Direct shear may act simultaneously.

  4. Flexible plates can add prying force.

    Use nominal tension and interaction rules exactly as specified by the course.

Long joints and large grip

A long joint may not share load equally

Decide whether a basic equal-bolt resistance needs a long-joint or large-grip adjustment.

Joint lengthEqual sharing requires the applicable model.
The end bolts and inner bolts sit along one load-transfer path. Relative plate deformation can change their load shares.

Prediction, then explanation. Adding more bolts over a longer joint need not produce a proportional usable resistance under the applicable reduction rule.

Identify the relevant joint length and grip from the actual detail. Compare them with the supplied thresholds before applying reductions.

Joint length is measured along load transfer. Grip is the total clamped thickness relevant to the bolt detail.

Scope. Use only reductions required by the stated code model. The sketch does not determine a reduction coefficient.

Check and takeaway. A larger bolt count is not a reason to omit the adjustment check. Keep geometry and resistance checks in the same design sequence.

Apply the reasoning to this section’s data and conditions

Source: Chapter 2 p.24.

Connections with more than two bolts and joint length over 500mm require a shear-capacity reduction under the cited Clause 9.3.6.1.4.

For ordinary bolts, total connected-ply thickness above five bolt diameters invokes the large-grip provision in Clause 9.3.6.1.5.

The actual reduction equations are not reproduced in the supplied materials.

Recognise the trigger, identify the missing clause information and avoid inventing a coefficient.

None of the standard concentric splice examples here should be treated as an unrestricted formula for arbitrarily long connections.

Mechanism detailsLoad sharing along a long joint1 concept

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Several bolts share a connection force, but a long joint need not distribute it perfectly evenly.
  2. Compatibility between the connected plates influences force attracted by bolts near the ends.
  3. Joint length is measured along the load path; grip is through the connected thickness.
  4. Apply long-joint or large-grip provisions only when their conditions are met.

    Arrows here are qualitative.

Fillet weld throat and capacity

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Why the weld throat is smaller than its leg

The shortest cut through the weld is thinner than the outside leg.

Why the weld throat is smaller than its leg — The shortest cut through the weld is thinner than the outside leg.

Sketch, not to scale; use the original dimensions.

  1. For the stated equal-leg 90° fillet, throat is approximately 0.7 × leg.
  2. Multiply throat area by the matching weld design strength.
  3. For force per length, use a one-millimetre weld strip.

Remember: Choose strength from both the steel grade and electrode class.

Related concept and full method

Source: Chapter 2 pp.31–33.

A 90° fillet with equal legs s has effective throat a≈0.7s.

The throat is the critical shortest section through the weld.

The simplified method compares the resultant force per unit length q with the throat resistance per unit length.

qcapacity=apw1,000=0.7spw1,000Units: kNmm. Required weld leg: s=1,000qrequired0.7pwUnits: mm.

For S355 with Class 42 electrode the supplied Table 9.2a gives pw=250Nmm2.

Select both the parent-steel row and electrode-class column.

“42” is not pw.

The supplied S275 columns use 220Nmm2; S460 with Class 50 uses 280Nmm2.

The directional method splits force per unit length into longitudinal FL and transverse resultant FT.

PL=pwa,PT=KPL, where K=1.251.51+cos2θ,θ is the force-to-throat angle specified in Figure 9.4.

Check (FLPL)2+(FTPT)2≤1.

The numerical fillet-weld examples on this site use the lecturer’s simplified method, so do not add the directional-method enhancement.

Mechanism detailsFrom fillet leg to effective throat1 concept · 6 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat .

    It is shorter than the leg.

  3. Effective resisting area = .

    With here, capacity per length is .

  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.

Unnumbered example: a 6mm S355/Class 42 fillet

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Keep the units on the same scale

Changing units is like changing the ruler, not the object.

Keep the units on the same scale — Changing units is like changing the ruler, not the object.

Sketch, not to scale; use the original dimensions.

  1. 1kN=1,000N; 1m=1,000mm.
  2. Area needs two length conversions; inertia needs four.
  3. Convert before substituting, then check the final unit.

Remember: A kN·m moment becomes 1,000,000 N·mm, not 1,000.

Related concept and full method

Source: Chapter 2 p.31 and L2 slide 6.

Required result: strength per millimetre of weld.

Given leg s=6mm and material/electrode combination; lookup pw=250Nmm2 from Table 9.2a, S355 row/Class 42 column.

Throat area in a one-millimetre strip

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

A one-millimetre strip has throat area a×1mm.

First calculate the throat.

This is why the factor 0.7 appears.

a=0.7×6=4.2mm; Astrip=4.2mm×1mm=4.2mm2.

Mechanism detailsFrom fillet leg to effective throat1 concept · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat .

    It is shorter than the leg.

  3. Effective resisting area = .

    With here, capacity per length is .

  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.

Multiply throat area by design strength

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Use the same mechanism: Change the ruler, keep the quantity. Would every property increase by ten? No. The exponent determines how many factors of ten are needed.

Apply the reasoning to this section’s data and conditions

Pstrip=4.2mm2×250Nmm2=1,050N=1.05kNq=1.05kN1mm=1.05kNmm

Exam script: q=0.7×6×2501,000=1.05kNmm. This is capacity per effective length; multiply by effective weld length for total capacity.

Mechanism detailsFrom fillet leg to effective throat2 concepts · 2 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat .

    It is shorter than the leg.

  3. Effective resisting area = .

    With here, capacity per length is .

  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.

Prediction and explained answer.

What is the corresponding strength of an 8mm weld with the same materials?

Answer and reasoning

a=0.7×8=5.6mm.

q=5.6×2501,000=1.40kNmm.

Capacity scales with leg size when materials remain the same.

Mechanism detailsFrom fillet leg to effective throat1 concept · 2 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat .

    It is shorter than the leg.

  3. Effective resisting area = .

    With here, capacity per length is .

  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.

Mechanism detailsFrom fillet leg to effective throat1 concept · 2 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat .

    It is shorter than the leg.

  3. Effective resisting area = .

    With here, capacity per length is .

  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.

Effective length, minimum sizes, laps and returns

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Drawn length and useful length differ

The start and end of a weld are not credited as fully effective in this course model.

Drawn length and useful length differ — The start and end of a weld are not credited as fully effective in this course model.

Sketch, not to scale; use the original dimensions.

  1. Find the effective length required by strength.
  2. Add the specified end allowance to each separate run.
  3. Round up, then check minimum size, spacing and returns.

Remember: Strength alone does not prove a weld detail is acceptable.

Related concept and full method

Chapter 2 p.34, Figure 9.3. End returns continue weld around corners; they are not the main longitudinal load-transfer lengths.

Chapter 2 p.34, Figure 9.3: an end return continues the weld around a corner.

It is not the main longitudinal load-transfer weld.

The source labels Return, 2s, meaning return length 2s.

s is the weld leg.

Other labels identify the Seat Bracket, Tension Member, End Connection Plate, Connection Angle and Beam End Connection.Open full-size image

Source: Chapter 2 pp.33–34.

For the lecture straight welds, effective length Leff=Lphysical−2s.

The deduction represents ineffective starts/ends.

If designing length, add 2s to the required effective length, then round up.

Apply it to each separately counted run, not once to the entire connection.

The minimum effective length is the greater of 4s and 40mm.

The notes’ minimum leg table based on the thicker part is 3mm through 6mm thickness, 5mm for 7–13mm, 6mm for 14–19mm, and 8mm over 19mm.

For a weld along a plate edge, maximum leg is plate thickness for thin plate below 6mm.

For plate equal to or thicker than 6mm, the maximum is thickness minus 2mm.

Do not increase a weld indefinitely on a thin angle edge.

Provide corner returns at least 2s, consistent with the source diagram and worked detailing (the prose at p.33 omits “not” before “less than”).

Lap length is at least max(5t,25mm), where t is the thinner plate.

The source also requires longitudinal weld length at least the transverse spacing between welds.

Long lap joints over 100s have further source-clause provisions.

Intermittent welds are unsuitable for fatigue conditions.

The notes limit unwelded gaps to 16t/300mm in compression or 24t/300mm in tension.

Check the stated detail, not just total weld strength.

Connection example 6: balance two weld lengths about the load line

Design the side fillet welds for a 65×50×8 angle carrying 60kN characteristic dead tension and 70kN characteristic imposed tension through its centroid. Use S355 steel and Class 42 electrode.

Original source: LectureNotes/Ch 2_Connection.pdf — p. 38.

A given value comes from the question or diagram.

A lookup value comes from the named table.

A calculated value follows from the working.

Each assumption is stated where the calculation needs it.

Known information, diagram labels and unknowns

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

InputOrigin
Given loads60kN dead,70kN imposed, arrows through dashed centroidal axis.
Given geometryThe left sketch labels 65×50×8 L; connected-leg width 65mm, centroid distance 21.1 and 43.9mm.
Design choiceLecturer tries 6mm fillet and final side lengths 140mm (X),75mm (Y), shown at right.
Lookup

Table 9.2a, S355 row/Class 42 column: pw=250Nmm2.

Throat a=0.7s.

Why this method applies

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

The weld closer to the load line carries more force.

Therefore that side needs a longer weld of the same size.

The two parallel weld lines share the tensile force across the 65mm separation.

Force equilibrium gives RX+RY=P.

Moment equilibrium about X gives RY×65=P×21.1.

Equal weld lengths would move the connection resultant away from the angle centroid.

1. Factored tensile force

Use the same mechanism: Keep load categories separate. Increasing imposed load changes its own term. It does not change the dead-load factor or the steel stiffness.

Apply the reasoning to this section’s data and conditions

P=1.4×60+1.6×70=84+112=196kN

Mechanism detailsFrom characteristic to design load1 concept · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. G is permanent load; Q is imposed load.

    A surface load and a line load also have different units.

  2. This illustration uses the course gravity case .

    Other combinations in the original text retain their own factors.

  3. For illustrative , the separate load contributions show what changes when Q increases.
  4. Do not carry this ULS total automatically into deflection.

    Follow the stated SLS load case.

2. Select a trial leg and find capacity per length

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Why the weld throat is smaller than its leg

The shortest cut through the weld is thinner than the outside leg.

Why the weld throat is smaller than its leg — The shortest cut through the weld is thinner than the outside leg.

Sketch, not to scale; use the original dimensions.

  1. For the stated equal-leg 90° fillet, throat is approximately 0.7 × leg.
  2. Multiply throat area by the matching weld design strength.
  3. For force per length, use a one-millimetre weld strip.

Remember: Choose strength from both the steel grade and electrode class.

Related concept and full method

s=6mm→a=0.7×6=4.2mmq=apw1,000=4.2×2501,000=1.05kNmmRequired total effective length: Pq=1961.05=186.667mm

The angle edge thickness is 8mm.

Therefore, the source maximum edge-weld leg 8−2=6mm permits this selection.

The supporting plate thickness is not given.

Its effect on the minimum weld-size rule remains a detailing condition.

Mechanism detailsFrom fillet leg to effective throat2 concepts · 2 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat .

    It is shorter than the leg.

  3. Effective resisting area = .

    With here, capacity per length is .

  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.

3. Share force and effective length between the sides

Unequal lever arms require unequal forces

Two longitudinal welds must transfer a tensile force through the angle centroid without an unintended moment.

The force line lies between welds. Each weld has its own perpendicular distance from that line.
The force line lies between welds. Each weld has its own perpendicular distance from that line.

Prediction, then explanation. The weld with the shorter lever arm must carry more force to balance the longer-arm weld’s moment.

Use force balance and moment balance together. Then divide each force by its own line resistance to find required effective length.

F1+F2=P,F1z1=F2z2F_1+F_2=P,\qquad F_1z_1=F_2z_2

P, F₁ and F₂ are forces. z₁ and z₂ are perpendicular distances from the load line. Use consistent length units.

Scope. Equal force shares apply only to the symmetric case. Physical terminated weld length also needs the supplied end deductions.

Check and takeaway. If the two lever arms become equal, the equations return equal forces. That limiting case checks the force distribution.

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Why two weld lengths can be unequal

Two side welds must balance the load about its actual line of action.

Why two weld lengths can be unequal — Two side welds must balance the load about its actual line of action.

Sketch, not to scale; use the original dimensions.

  1. Find the load line and the lever arm to each weld.
  2. Balance moments as well as the total force.
  3. Convert each weld’s force into its own required length.

Remember: Equal-looking legs do not justify equal weld forces without equilibrium.

Related concept and full method

RY=196×21.165=63.6246kNRX=196−63.6246=132.3754kNAlternatively calculate directly 196×43.965. LX,eff=132.37541.05=126.0718mmLY,eff=63.62461.05=60.5949mm

Check: the forces sum 196kN and the required lengths sum 186.6667mm.

The larger 43.9mm opposite lever arm produces the larger SideX force.

Mechanism detailsBalance two weld forces2 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. The angle centroid/load line is generally not halfway between the two weld runs.
  2. .

    Both weld runs contribute to the applied force.

  3. .

    The run nearer the load line carries more force.

  4. For equal throat resistance per length, the required effective lengths follow the same ratio.

    Add detailing allowances afterwards.

4. Add end allowances, round up and check the actual lengths

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Use the same mechanism: Unequal lever arms require unequal forces. The weld with the shorter lever arm must carry more force to balance the longer-arm weld’s moment.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Drawn length and useful length differ

The start and end of a weld are not credited as fully effective in this course model.

Drawn length and useful length differ — The start and end of a weld are not credited as fully effective in this course model.

Sketch, not to scale; use the original dimensions.

  1. Find the effective length required by strength.
  2. Add the specified end allowance to each separate run.
  3. Round up, then check minimum size, spacing and returns.

Remember: Strength alone does not prove a weld detail is acceptable.

Related concept and full method

Side X actual length: ≥126.0718+2×6=138.0718mm→140mmSide Y actual length: ≥60.5949+12=72.5949mm→75mmProvided effective length: X=140−12=128mm;Y=75−12=63mmResistance: X=128×1.05=134.4kN>132.3754Y=63×1.05=66.15kN>63.6246

Each effective length exceeds max(4×6,40)=40mm.

The physical side lengths 140 and 75mm also exceed the 65mm transverse separation, matching the source detailing check.

The extra rounding increases available resistance.

The actual force split still follows equilibrium.

End-return/support-plate details are not fully specified.

Therefore, this is the completed requested side-weld strength/length design, not a complete fabrication detail.

Mechanism detailsFrom fillet leg to effective throat2 concepts · 2 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat .

    It is shorter than the leg.

  3. Effective resisting area = .

    With here, capacity per length is .

  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.

Result and concise exam wording

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

P=196kN.

Use 6mm fillet, q=1.05kNmm.

Force split X/Y=132.375/63.625kN.

Required effective lengths 126.072/60.595mm.

Add 12mm to each and provide 140mm (X),75mm (Y); effective capacities 134.4/66.15kN exceed the assigned forces.

Misconceptions and checks

Use the same mechanism: One connected leg does not load both legs equally. Keeping the same gross area does not guarantee the same tension resistance when the connection arrangement changes.

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

  • Read the angle label: the source says 8mm thick, not 6mm.
  • Use the opposite centroid lever arm when allocating weld force.
  • Add 2s separately to both weld runs.
  • Do not use total capacity alone if one side is too short.

How the method transfers to a new variant

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

  1. Locate the centroidal load line and both weld lines.
  2. Factor loads and select a permitted trial weld leg.
  3. Use force and moment equilibrium for the two side forces.
  4. Divide each force by weld strength per length.
  5. Add individual end deductions back, round up, and recheck each side.

Prediction with explained answer

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

Prediction and explained answer.

Suppose the same 196kN force acts midway between the 65mm-spaced weld lines.

What physical length is required on each side for 6mm weld?

Answer and reasoning

Each side takes 98kN.

Required effective length=981.05=93.333mm.

Add 12mm→105.333mm; choose 110mm each.

Centred loading makes equal lengths appropriate.

Mechanism detailsBalance two weld forces2 concepts · 2 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. The angle centroid/load line is generally not halfway between the two weld runs.
  2. .

    Both weld runs contribute to the applied force.

  3. .

    The run nearer the load line carries more force.

  4. For equal throat resistance per length, the required effective lengths follow the same ratio.

    Add detailing allowances afterwards.

Connection example 9: a welded single unequal angle

Check a 75×50×6 S355 single angle connected by its long leg under 95kN dead plus 40kN imposed tension, and design the two side welds with Class 42 electrode.

Original source: LectureNotes/Ch 2_Connection.pdf — p. 42.

A given value comes from the question or diagram.

A lookup value comes from the named table.

A calculated value follows from the working.

Each assumption is stated where the calculation needs it.

Known information, diagram labels and unknowns

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

InputOrigin
Given loads95kN dead and 40kN imposed, task text.
Given dimensions75×50×6 angle; source diagram shows 72 and 47mm half-heel widths and 12.1mm centroid height.
Lookup centroid

24.4mm from SideX stated from section table in solution and labelled in diagram.

Opposite arm 75−24.4=50.6mm.

Lookup strengthsS355 thickness 6mm → py=355; S355/Class 42 →pw=250Nmm2.
Design choice4mm fillet, physical lengths 200mm (X),100mm (Y), lecturer solution.

Why this method applies

Use the same mechanism: Unequal lever arms require unequal forces. The weld with the shorter lever arm must carry more force to balance the longer-arm weld’s moment.

Use the same mechanism: One connected leg does not load both legs equally. Keeping the same gross area does not guarantee the same tension resistance when the connection arrangement changes.

Apply the reasoning to this section’s data and conditions

First check that the angle itself can carry the force: stronger welds cannot cure a weak angle.

With no bolt holes, the gross area is effective, but a single welded connected leg still has the 0.3a2 reduction for the unconnected leg.

Then balance the two parallel weld forces about the centroid using their opposite lever arms.

1. Factored force and welded-angle resistance

Use the same mechanism: One connected leg does not load both legs equally. Keeping the same gross area does not guarantee the same tension resistance when the connection arrangement changes.

Use the same mechanism: Keep load categories separate. Increasing imposed load changes its own term. It does not change the dead-load factor or the steel stiffness.

Apply the reasoning to this section’s data and conditions

Physical interpretation: One connected leg does not load both legs equally

The connected leg receives the pull first.

The other leg receives it through the angle.

One connected leg does not load both legs equally — The connected leg receives the pull first; the other leg receives it through the angle.

Sketch, not to scale; use the original dimensions.

  1. Identify connected and outstanding legs from the drawing.
  2. Use the relevant bolted or welded angle rule.
  3. Keep the lecturer’s area convention consistent.

Remember: Bolted and welded reduction expressions are not the same rule.

Related concept and full method

P=1.4×95+1.6×40=133+64=197kNa1=(75−62)×6=72×6=432mm2a2=(50−62)×6=47×6=282mm2Ae=Ag=432+282=714mm2No holes.Pt=355(714−0.3×282)1,000=355(714−84.6)1,000=355×629.41,000=223.437kN>197Passes.

The 0.3 factor comes from the single welded angle rule on Ch 2 p.14.

The bolted value 0.5 would be a different connection model.

Mechanism detailsWhy a connected angle leg matters2 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Locate the connected leg, outstanding leg and centroid before using the table.
  2. Only the connected leg directly receives the fastener force.
  3. The outstanding area may not become equally effective at the same section.

    This motivates the effective-area rule.

  4. Bolted, welded, single-angle and double-angle details can have different rules.

    Preserve the formula attached to the original case.

2. Trial 4mm weld and balanced required lengths

Use the same mechanism: Unequal lever arms require unequal forces. The weld with the shorter lever arm must carry more force to balance the longer-arm weld’s moment.

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Why two weld lengths can be unequal

Two side welds must balance the load about its actual line of action.

Why two weld lengths can be unequal — Two side welds must balance the load about its actual line of action.

Sketch, not to scale; use the original dimensions.

  1. Find the load line and the lever arm to each weld.
  2. Balance moments as well as the total force.
  3. Convert each weld’s force into its own required length.

Remember: Equal-looking legs do not justify equal weld forces without equilibrium.

Related concept and full method

q=0.7×4×2501,000=0.70kNmmTotal effective length: Leff=1970.70=281.4286mmRX=197×50.675=132.9093kNRY=197×24.475=64.0907kNLX,eff=132.90930.70=189.8705mmLY,eff=64.09070.70=91.5581mm

The 12.1mm centroid height is visible in the section but is not the transverse lever arm for sharing these two side-weld forces.

The side-to-side 24.4/50.6 dimensions are the relevant ones.

Mechanism detailsBalance two weld forces2 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. The angle centroid/load line is generally not halfway between the two weld runs.
  2. .

    Both weld runs contribute to the applied force.

  3. .

    The run nearer the load line carries more force.

  4. For equal throat resistance per length, the required effective lengths follow the same ratio.

    Add detailing allowances afterwards.

3. Final lengths, capacities and source correction

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Use the same mechanism: Unequal lever arms require unequal forces. The weld with the shorter lever arm must carry more force to balance the longer-arm weld’s moment.

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Drawn length and useful length differ

The start and end of a weld are not credited as fully effective in this course model.

Drawn length and useful length differ — The start and end of a weld are not credited as fully effective in this course model.

Sketch, not to scale; use the original dimensions.

  1. Find the effective length required by strength.
  2. Add the specified end allowance to each separate run.
  3. Round up, then check minimum size, spacing and returns.

Remember: Strength alone does not prove a weld detail is acceptable.

Related concept and full method

End allowance per weld =2s=8mm. Side X actual length: ≥189.8705+8=197.8705mm→200mmSide Y actual length: ≥91.5581+8=99.5581mm→100mmProvided effective length on side X =200−8=192mm, resistance 134.4kN>132.9093. Side Y effective length =100−8=92mm, resistance 64.4kN>64.0907.

Both effective lengths exceed max(16,40)=40mm, and both physical lengths exceed 75mm separation.

For the 6mm angle edge the maximum leg is 6−2=4mm, matching the selection.

The minimum-size rule depends on the unknown supporting plate thickness.

Do not assume it from the sketch.

Mechanism detailsFrom fillet leg to effective throat3 concepts · 4 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat .

    It is shorter than the leg.

  3. Effective resisting area = .

    With here, capacity per length is .

  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.

Result and concise exam wording

Use the same mechanism: One connected leg does not load both legs equally. Keeping the same gross area does not guarantee the same tension resistance when the connection arrangement changes.

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

P=197kN.

Welded single-angle capacity=355(714−0.3×282)1,000=223.437kN.

Use 4mm fillets with q=0.70kNmm.

Required effective X/Y lengths 189.870/91.558mm.

Provide 200/100mm physical lengths (192/92mm effective), giving 134.4/64.4kN against 132.909/64.091kN.

Angle and weld strength pass; support-thickness detailing is unprovided.

Misconceptions and checks

Use the same mechanism: One connected leg does not load both legs equally. Keeping the same gross area does not guarantee the same tension resistance when the connection arrangement changes.

Apply the reasoning to this section’s data and conditions

  • Do not subtract holes from a welded angle with no holes.
  • The unconnected leg still needs the 0.3 reduction.
  • For the 4mm weld, the source writes “Add 12” (add 12) is a textual error.

    It should be 2s=8.

  • Do not use 12.1mm centroid height in the 75mm transverse weld-force split.

How the method transfers to a new variant

Use the same mechanism: Unequal lever arms require unequal forces. The weld with the shorter lever arm must carry more force to balance the longer-arm weld’s moment.

Use the same mechanism: One connected leg does not load both legs equally. Keeping the same gross area does not guarantee the same tension resistance when the connection arrangement changes.

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

  1. Check angle area and the appropriate welded single-leg resistance.
  2. Read centroid location from the source/table.
  3. Select a weld leg permitted by the angle edge.
  4. Balance side forces, calculate effective lengths, then add 2s to each.
  5. Verify each rounded side and the detailing conditions.

Prediction with explained answer

Use the same mechanism: One connected leg does not load both legs equally. Keeping the same gross area does not guarantee the same tension resistance when the connection arrangement changes.

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

Prediction and explained answer.

If the imposed load rises to 45kN, do the existing 200/100mm welds still pass?

Answer and reasoning

P=133+72=205kN.

SideX demand=205×50.675=138.307kN>134.4; SideY=66.693kN>64.4.

Both weld sides fail although angle capacity 223.437 still passes.

Mechanism detailsBalance two weld forces3 concepts · 3 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. The angle centroid/load line is generally not halfway between the two weld runs.
  2. .

    Both weld runs contribute to the applied force.

  3. .

    The run nearer the load line carries more force.

  4. For equal throat resistance per length, the required effective lengths follow the same ratio.

    Add detailing allowances afterwards.

Connection example 10: welded splice and a minimum-size discrepancy

Design a welded double-cover splice transferring 700kN ultimate tension between 150×20mm S355 main plates. Cover thickness is 12mm. Use Class 42 electrode. Explain the lecturer’s 6mm-weld solution, then reconcile it with the chapter’s minimum weld-size table.

Original source: LectureNotes/Ch 2_Connection.pdf — p. 43, p. 44.

A given value comes from the question or diagram.

A lookup value comes from the named table.

A calculated value follows from the working.

Each assumption is stated where the calculation needs it.

Known information, diagram labels and unknowns

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

InputOrigin
Given demand

700kN ultimate.

Do not factor again.

Given platesMain width 150mm and thickness 20mm; two covers 12mm thick.
Selected cover widthLecturer chooses 100mm to leave flat room for edge welds; not a given dimension.
Lookup

S355 py=345 for 20mm main,355 for 12mm covers.

pw=250Nmm2 for Class 42.

Detailing lookup

Chapter 2 p.33 Table 9.1: thicker part over 19mm requires minimum leg 8mm.

Here the thicker connected main plate is 20mm.

Why this method applies

Use the same mechanism: Test every possible fracture cut. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

The force enters one half-splice from the main plate and divides equally between two covers.

Each cover has two longitudinal weld runs, so four runs share the 700kN on each side of the butt.

Size runs using effective length, check laps/returns and check unperforated plate tension.

The lecturer’s strength arithmetic is reproducible, but a final choice must also satisfy the supplied minimum-size rule.

1. Select and interpret the covers

Follow tension through the intact plate

Check a plate region without bolt holes under the stated axial tension model.

btPPOne resisting cut: area = width × thickness
The cut rectangle has width b and thickness t. The load passes through this resisting area.

Prediction, then explanation. For unchanged strength and uniform stress, doubling width doubles the area and its yield resistance.

Calculate the resisting area. Multiply by the applicable design strength. Compare that resistance with the force carried by this plate.

A=bt,Pt=pyAA=bt,\qquad P_t=p_yA

b and t use mm; A uses mm²; py uses N/mm². The product gives resistance in N.

Scope. This simple expression does not include holes, shear lag, eccentric bending or other required connection checks.

Check and takeaway. If two identical covers share the load symmetrically, each carries half. The main plate still carries the total force before the split.

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

Selected cover-plate width =100mm. Allowance on each side: 150−1002=25mm

This is an explicit design choice providing space to place the weld on the main plate.

Two 12mm covers have combined thickness 24mm but are checked individually at half force 350kN.

The source uses the full welded plate area: no bolt-hole deductions.

Mechanism detailsTension through an unperforated plate2 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. For this concentric, unperforated plate, the full width and thickness form the resisting section.

    There are no bolt holes to deduct.

  2. The illustrative width is 100 mm.

    Adjust thickness t: , in .

  3. Using illustrative , in kN.

    Use the actual material and thickness band for the original question.

  4. The covers are moved apart for visibility.

    A symmetric pair each carries half the force.

    Check the main plate, each cover and the welds separately.

2. Reproduce the lecturer’s strength calculation

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Drawn length and useful length differ

The start and end of a weld are not credited as fully effective in this course model.

Drawn length and useful length differ — The start and end of a weld are not credited as fully effective in this course model.

Sketch, not to scale; use the original dimensions.

  1. Find the effective length required by strength.
  2. Add the specified end allowance to each separate run.
  3. Round up, then check minimum size, spacing and returns.

Remember: Strength alone does not prove a weld detail is acceptable.

Related concept and full method

The source trials s=6mm: q=0.7×6×2501,000=1.05kNmmRequired total effective length per half: 7001.05=666.6667mm4 welds each require effective length: 666.66674=166.6667mmActual length per weld: ≥166.6667+2×6=178.6667mm→180mmProvided effective length per weld: 180−12=168mmHalf-splice resistance: 4×168×1.05=705.6kN>700kN

The four runs on the other side of the butt transfer the same 700kN in series.

Do not add both halves to claim 1,411.2kN splice resistance.

Mechanism detailsFrom fillet leg to effective throat1 concept · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat .

    It is shorter than the leg.

  3. Effective resisting area = .

    With here, capacity per length is .

  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.

3. Reconcile the minimum-size table and give a corrected detail

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

The lecturer checks lap≥5×12=60mm, physical run 180≥100mm transverse spacing, and returns 15≥2×6=12mm.

However the 20mm main plate triggers the 8mm minimum in Table 9.1 on p.33.

The 6mm selection is inconsistent with that supplied table.

Select s=8mm: q=0.7×8×2501,000=1.40kNmmRequired effective length per weld: 7004×1.40=125mmActual length: ≥125+2×8=141mm→select145mmProvided effective length: 145−16=129mmResistance per half: 4×129×1.40=722.4kN>700Minimum effective length: max(4×8,40)=40mm<129Lap length: 145mm≥max(5×12,25)=60mmActual weld length 145mm≥100mm transverse spacing. Provide end return 20mm≥2×8=16mm. 12mm cover-plate edge, maximum weld leg =12−2=10mm≥8mm.

The corrected detail uses 8mm fillets,145mm physical longitudinal runs on each half of each cover edge, and 20mm returns.

This is an authored correction, clearly distinguished from the lecturer’s dimensions.

Mechanism detailsFrom fillet leg to effective throat2 concepts · 4 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat .

    It is shorter than the leg.

  3. Effective resisting area = .

    With here, capacity per length is .

  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.

4. Verify main and cover plate tension

Use the same mechanism: Follow tension through the intact plate. For unchanged strength and uniform stress, doubling width doubles the area and its yield resistance.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Why holes reduce tension resistance

The pull must squeeze through the steel left beside the holes.

Why holes reduce tension resistance — The pull must squeeze through the steel left beside the holes.

Sketch, not to scale; use the original dimensions.

  1. Choose a possible fracture line across the member.
  2. Subtract the holes crossed by that line using hole diameter.
  3. Apply the course effective-area rule and its gross-area limit.

Remember: Do not subtract every hole anywhere in the connection.

Related concept and full method

Main plate: A=150×20=3,000mm2Pt=3,000×3451,000=1,035kN>700Each cover plate: A=100×12=1,200mm2Pt=1,200×3551,000=426kN>350Both plates together: Pt=2×426=852kN>700

The corrected welded load path is governed by 722.4kN weld resistance, above 700kN.

Main and cover tension pass.

Every area is unperforated, so it equals the effective area for this concentric plate connection.

Mechanism detailsTension through an unperforated plate1 concept · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. For this concentric, unperforated plate, the full width and thickness form the resisting section.

    There are no bolt holes to deduct.

  2. The illustrative width is 100 mm.

    Adjust thickness t: , in .

  3. Using illustrative , in kN.

    Use the actual material and thickness band for the original question.

  4. The covers are moved apart for visibility.

    A symmetric pair each carries half the force.

    Check the main plate, each cover and the welds separately.

Result and concise exam wording

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

Source arithmetic:6mm fillets,180mm physical runs give 705.6kN per half; plates give 1,035kN main and 852kN cover pair.

But Table 9.1 requires 8mm for the 20mm thicker part.

Corrected detail:8mm fillets,145mm physical runs on each of four runs per half,20mm returns.

Effective length 129mm/run gives 722.4kN; lap, length and edge-leg limits pass.

Misconceptions and checks

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

  • Four parallel runs occur on each half-splice; opposite halves are in series.
  • The cover width 100mm is selected, not the 150mm main width.
  • Strength adequacy does not override the supplied minimum weld-size table.
  • Increasing leg size changes the 2s length deduction.

How the method transfers to a new variant

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

  1. Select cover width with room for welds and check plate strength.
  2. Count parallel weld runs on one transfer side only.
  3. Find required effective length, add 2s and round up.
  4. Check minimum/maximum leg, lap, returns and transverse-spacing rules.
  5. Resolve source discrepancies explicitly and verify the corrected detail.

Prediction with explained answer

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

Prediction and explained answer.

For the corrected 8mm welds, would 140mm physical longitudinal runs be sufficient?

Hint

Recompute effective length after selecting the physical length.

Answer and reasoning

Effective length 140−16=124mm.

Resistance=4×124×1.40=694.4kN<700kN, so no.

Rounding the 141mm minimum down to 140mm loses required capacity.

Mechanism detailsFrom fillet leg to effective throat1 concept · 2 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat .

    It is shorter than the leg.

  3. Effective resisting area = .

    With here, capacity per length is .

  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.

Mechanism detailsFrom fillet leg to effective throat2 concepts · 2 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat .

    It is shorter than the leg.

  3. Effective resisting area = .

    With here, capacity per length is .

  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.

Butt welds and inspection

Use the same mechanism: Penetration changes the resisting section. Keeping the same plate thickness does not make partial and full penetration equivalent.

Apply the reasoning to this section’s data and conditions

Source: Chapter 2 p.34.

A full-penetration butt weld can be taken as strong as its parent metal when the weld metal strength is not lower.

Back-gouging/chipping before welding the reverse side or use of a backing plate can achieve penetration in the source discussion.

A partial-penetration joint does not automatically have full parent-plate capacity.

In an exam sketch, show the prepared edges and distinguish full from partial penetration.

Mechanism detailsFull and partial weld penetration1 concept

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Two plates meet edge to edge.

    The open groove in this schematic exposes the thickness that must be joined.

  2. A full-penetration butt weld joins through the complete thickness.

    The gold section shows the continuous weld metal.

  3. A partial-penetration weld leaves part of the thickness unjoined.

    The dark root gap is not resisting weld metal.

  4. The course permits parent-metal strength for full penetration when weld metal is not weaker.

    Confirm penetration and inspection.

    Do not give the same capacity automatically to a partial joint.

Eccentric welds: use line properties, not plate properties

Use the same mechanism: Treat a weld group as lines. Increasing eccentricity increases the torsional contribution. The governing corner depends on vector addition, not distance alone.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Only the weld lines resist as weld

Imagine a wire rectangle: its empty middle is not more wire.

Only the weld lines resist as weld — Imagine a wire rectangle: its empty middle is not more wire.

Sketch, not to scale; use the original dimensions.

  1. Count only the weld runs actually shown.
  2. Use their total length and line second moments.
  3. Combine direct and torsional forces at the critical location.

Remember: Line second moments have units mm3; plate-area moments use mm4.

Related concept and full method

Physical interpretation: Add arrows before taking the magnitude

Walking east and walking north do not point in the same direction.

Add arrows before taking the magnitude — Walking east and walking north do not point in the same direction.

Sketch, not to scale; use the original dimensions.

  1. Choose signed horizontal and vertical directions.
  2. Add contributions along each direction separately.
  3. For perpendicular components, use the right-triangle resultant.

Remember: Check the corner where direct and torsional components reinforce each other.

Related concept and full method

Source: Chapter 2 pp.35–37.

For a closed rectangular weld of width b and height h, all four weld lines share direct shear.

The plate interior is not weld.

For uniform weld size, the common throat cancels in the force-per-length calculation.

Therefore the geometrical line second moments have units mm3, not mm4.

L=2(b+h)Ix,line=2(h312)+2b(h2)2=h36+bh22Iy,line=2(b312)+2h(b2)2=b36+hb22Ip,line=Ix,line+Iy,line

The vertical lines each contribute h312 about the centroidal x axis.

The two horizontal lines each have length b at distance h2, giving b(h2)2 by the parallel-axis rule.

Reverse b and h for Iy.

At a corner, x=b2, y=h2 and r=x2+y2.

Measure eccentricity e from the weld centroid to the applied load line, not automatically from the column face.

qs=PLqT=PerIp,lineBoth have units kNmm. qmax=(PL+Pe|x|Ip,line)2+(Pe|y|Ip,line)2

The critical corner is where the vertical torsion component adds to direct shear.

Calculate required leg from qmax and pw, then satisfy detailing.

For a bracket in the perpendicular plane, use the flange/web force-couple model in Example 8, not these in-plane torsion equations.

A three-sided weld has a different centroid, line length and inertia: recompute them from its actual weld lines.

Connection example 7: calculate a rectangular weld group from first principles

Find the maximum force per unit weld length and select a fillet weld for one side plate carrying 60kN dead plus 90kN imposed load. The weld is on all four sides of a 200mm×300mm rectangle; the force eccentricity from its centre is 300mm. Steel is S355 with Class 42 electrode.

Original source: LectureNotes/Ch 2_Connection.pdf — p. 39, p. 40.

A given value comes from the question or diagram.

A lookup value comes from the named table.

A calculated value follows from the working.

Each assumption is stated where the calculation needs it.

Known information, diagram labels and unknowns

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

InputOrigin
Given geometry

b=200mm,h=300mm; four weld sides.

Centre is at half width/height: x=100,y=150mm at a corner.

Given load arme=300mm from group centroid, not from the right edge.
Given materialsS355/Class 42 → lookup pw=250Nmm2, Table 9.2a.
AssumptionUniform fillet size, rigid plate and line-weld elastic distribution, as in Ch 2 pp.35–37.

Why this method applies

Use the same mechanism: Treat a weld group as lines. Increasing eccentricity increases the torsional contribution. The governing corner depends on vector addition, not distance alone.

Use the same mechanism: Add force components at each bolt. At fixed force, increasing eccentricity increases the moment component. Its direction differs between bolts.

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

Separate direct shear PL from torsional force caused by Pe.

Use the weld lines for centroid and inertia.

The plate interior does not carry weld force.

Derive line inertias with the parallel-axis rule.

Then combine the horizontal and vertical force-per-length components at the right-hand corner, where vertical components add.

1. Geometry and factored force

Use the same mechanism: Treat a weld group as lines. Increasing eccentricity increases the torsional contribution. The governing corner depends on vector addition, not distance alone.

Use the same mechanism: Keep load categories separate. Increasing imposed load changes its own term. It does not change the dead-load factor or the steel stiffness.

Apply the reasoning to this section’s data and conditions

L=2(b+h)=2(200+300)=1,000mmP=1.4×60+1.6×90=84+144=228kNM=Pe=228×300=68,400kN·mmr=1002+1502=32,500=180.278mm

Mechanism detailsA weld group is a set of lines2 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. The centre is empty: resistance comes from the weld lines, not a solid plate filling the group.
  2. Use line lengths for centroid weighting.

    Line second moments have units .

    Add the parallel-axis terms.

  3. Direct force per length is .

    The eccentric moment adds tangential flow proportional to distance from the centroid.

  4. Combine signed components at every candidate corner, then compare the maximum with throat resistance per length.

2. Derive both line second moments

Use the same mechanism: Treat a weld group as lines. Increasing eccentricity increases the torsional contribution. The governing corner depends on vector addition, not distance alone.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Only the weld lines resist as weld

Imagine a wire rectangle: its empty middle is not more wire.

Only the weld lines resist as weld — Imagine a wire rectangle: its empty middle is not more wire.

Sketch, not to scale; use the original dimensions.

  1. Count only the weld runs actually shown.
  2. Use their total length and line second moments.
  3. Combine direct and torsional forces at the critical location.

Remember: Line second moments have units mm3; plate-area moments use mm4.

Related concept and full method

About the horizontal centroidal x axis: two vertical welds each contribute h312; two horizontal welds each contribute b(h2)2.

About the vertical axis reverse the roles.

Ix=2(300312)+2×200×1502=4,500,000+9,000,000=13,500,000mm3Iy=2(200312)+2×300×1002=1,333,333.333+6,000,000=7,333,333.333mm3Ip=Ix+Iy=20,833,333.333mm3

Why is the unit mm3?

Weld-line length (mm) multiplied by distance squared (mm2) gives that unit.

Do not substitute the second moment of area of a solid rectangular plate, bh312, whose unit is mm4.

Mechanism detailsA weld group is a set of lines1 concept · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. The centre is empty: resistance comes from the weld lines, not a solid plate filling the group.
  2. Use line lengths for centroid weighting.

    Line second moments have units .

    Add the parallel-axis terms.

  3. Direct force per length is .

    The eccentric moment adds tangential flow proportional to distance from the centroid.

  4. Combine signed components at every candidate corner, then compare the maximum with throat resistance per length.

3. Uniform direct shear per length

Use the same mechanism: Treat a weld group as lines. Increasing eccentricity increases the torsional contribution. The governing corner depends on vector addition, not distance alone.

Apply the reasoning to this section’s data and conditions

qs=PL=228kN1,000mm=0.228kNmm

Mechanism detailsA weld group is a set of lines1 concept · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. The centre is empty: resistance comes from the weld lines, not a solid plate filling the group.
  2. Use line lengths for centroid weighting.

    Line second moments have units .

    Add the parallel-axis terms.

  3. Direct force per length is .

    The eccentric moment adds tangential flow proportional to distance from the centroid.

  4. Combine signed components at every candidate corner, then compare the maximum with throat resistance per length.

4. Torsional components at the critical corner

Use the same mechanism: Treat a weld group as lines. Increasing eccentricity increases the torsional contribution. The governing corner depends on vector addition, not distance alone.

Apply the reasoning to this section’s data and conditions

qT=MrIp=68,400×180.27820,833,333.333=0.591888kNmmVertical component: MxIp=68,400×10020,833,333.333=0.32832kNmmHorizontal component: MyIp=68,400×15020,833,333.333=0.49248kNmm

The source uses cosφ=100r≈0.555 for the angle between the vertical direct shear and the tangential torsion force.

The corner radius itself is not the force direction.

Mechanism detailsA weld group is a set of lines1 concept · 2 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. The centre is empty: resistance comes from the weld lines, not a solid plate filling the group.
  2. Use line lengths for centroid weighting.

    Line second moments have units .

    Add the parallel-axis terms.

  3. Direct force per length is .

    The eccentric moment adds tangential flow proportional to distance from the centroid.

  4. Combine signed components at every candidate corner, then compare the maximum with throat resistance per length.

5. Add components and calculate the maximum

Use the same mechanism: Treat a weld group as lines. Increasing eccentricity increases the torsional contribution. The governing corner depends on vector addition, not distance alone.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Add arrows before taking the magnitude

Walking east and walking north do not point in the same direction.

Add arrows before taking the magnitude — Walking east and walking north do not point in the same direction.

Sketch, not to scale; use the original dimensions.

  1. Choose signed horizontal and vertical directions.
  2. Add contributions along each direction separately.
  3. For perpendicular components, use the right-triangle resultant.

Remember: Check the corner where direct and torsional components reinforce each other.

Related concept and full method

qvertical=0.228+0.32832=0.55632kNmmqmax=0.556322+0.492482=0.742986kNmm

The opposite column of weld has vertical components subtracting, hence a smaller resultant.

The upper and lower right corners have the same maximum magnitude.

Mechanism detailsA weld group is a set of lines1 concept · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. The centre is empty: resistance comes from the weld lines, not a solid plate filling the group.
  2. Use line lengths for centroid weighting.

    Line second moments have units .

    Add the parallel-axis terms.

  3. Direct force per length is .

    The eccentric moment adds tangential flow proportional to distance from the centroid.

  4. Combine signed components at every candidate corner, then compare the maximum with throat resistance per length.

6. Size the fillet and check its resistance

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Why the weld throat is smaller than its leg

The shortest cut through the weld is thinner than the outside leg.

Why the weld throat is smaller than its leg — The shortest cut through the weld is thinner than the outside leg.

Sketch, not to scale; use the original dimensions.

  1. For the stated equal-leg 90° fillet, throat is approximately 0.7 × leg.
  2. Multiply throat area by the matching weld design strength.
  3. For force per length, use a one-millimetre weld strip.

Remember: Choose strength from both the steel grade and electrode class.

Related concept and full method

srequired=1,000qmax0.7pw=1,000×0.7429860.7×250=4.24564mmThe lecturer selects s=6mm. qcapacity=0.7×6×2501,000=1.05kNmm>0.742986Weld strength passes.

The closed four-side weld is treated as the full line rectangle by the source method.

This differs from separately terminated side welds with 2s start/end deductions.

The plate thickness is absent.

Therefore, the numerical strength result is complete but minimum/maximum permitted leg size cannot be confirmed from Table 9.1/edge-thickness rules.

The 6mm choice is the lecturer’s selection, conditional on those missing detailing inputs.

Mechanism detailsFrom fillet leg to effective throat1 concept · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat .

    It is shorter than the leg.

  3. Effective resisting area = .

    With here, capacity per length is .

  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.

Result and concise exam wording

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

P=228kN,e=300mm,L=1,000mm,Ip,line=20.83333×106mm3.

qs=0.228; torsion components 0.32832 vertical and 0.49248 horizontal kN/mm.

qmax=0.742986kNmm.

s≥4.246mm;6mm fillet supplies 1.05kNmm and passes weld strength.

Plate-thickness detailing remains unverified because it is not given.

Misconceptions and checks

Use the same mechanism: Treat a weld group as lines. Increasing eccentricity increases the torsional contribution. The governing corner depends on vector addition, not distance alone.

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

  • The two 300mm dimensions mean different things: height and eccentricity.
  • Use line inertia in mm3, not solid-plate inertia in mm4.
  • The dashed right edge still belongs to the stated four-side weld.
  • Do not certify minimum/maximum weld size without the plate thickness.

How the method transfers to a new variant

Use the same mechanism: Treat a weld group as lines. Increasing eccentricity increases the torsional contribution. The governing corner depends on vector addition, not distance alone.

Use the same mechanism: Add force components at each bolt. At fixed force, increasing eccentricity increases the moment component. Its direction differs between bolts.

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

  1. Identify every actual weld line and its load path.
  2. Find centroid, length and line inertias.
  3. Measure load eccentricity from the centroid.
  4. Calculate direct and torsional components and the critical resultant.
  5. Solve for leg size and check detailing separately.

Prediction with explained answer

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

Prediction and explained answer.

Keep the same load and rectangle but move the load line through the weld centroid.

Find required strength and leg by strength alone.

Answer and reasoning

e=0 so torsion vanishes.

q=2281,000=0.228kNmm.

s≥1,000×0.228175=1.303mm by strength alone.

The actual selected leg is still controlled by minimum/detailing rules; a 1.3mm design cannot be adopted just from this strength result.

Mechanism detailsA weld group is a set of lines1 concept · 3 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. The centre is empty: resistance comes from the weld lines, not a solid plate filling the group.
  2. Use line lengths for centroid weighting.

    Line second moments have units .

    Add the parallel-axis terms.

  3. Direct force per length is .

    The eccentric moment adds tangential flow proportional to distance from the centroid.

  4. Combine signed components at every candidate corner, then compare the maximum with throat resistance per length.

Connection example 8: flange welds carry moment, web welds carry shear

Design the bracket welds for 100kN dead plus 140kN imposed load at 250mm from the support. The bracket is cut from a 356×171×67 UB. The specified web-weld leg is half the flange-weld leg. Use S355 and Class 42 electrode.

Original source: LectureNotes/Ch 2_Connection.pdf — p. 41.

A given value comes from the question or diagram.

A lookup value comes from the named table.

A calculated value follows from the working.

Each assumption is stated where the calculation needs it.

Known information, diagram labels and unknowns

Use the same mechanism: A force couple carries moment. For the same moment, a larger lever arm requires a smaller couple force. It does not remove the web shear.

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

InputOrigin
Given load100kN dead,140kN imposed; downward arrow at e=250mm from connection face.
Given weld geometryB=150mm across flange run; D=364.6mm vertical arm; a=280mm web run; all explicitly dimensioned.
Given size relationshipsweb=sflange2。
Lookup/model

pw=250Nmm2.

Rotate about X1–X1 at bottom flange; flange weld takes moment, two web welds take direct shear.

This is the source’s simplified force allocation.

Why this method applies

Use the same mechanism: Add force components at each bolt. At fixed force, increasing eccentricity increases the moment component. Its direction differs between bolts.

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

Do not treat this as a rectangular in-plane torsion weld.

The vertical load outside the supporting face produces flange tension and compression.

Moment equilibrium gives tensile flange force F=MD.

Divide that force by the effective flange weld length to get demand per millimetre.

Because effective length depends on chosen leg, select a trial leg and verify it self-consistently.

1. Design force and force couple

Use the same mechanism: A force couple carries moment. For the same moment, a larger lever arm requires a smaller couple force. It does not remove the web shear.

Apply the reasoning to this section’s data and conditions

P=1.4×100+1.6×140=140+224=364kNM=Pe=364×250=91,000kN·mmFlange force: F=MD=91,000364.6=249.589kN

Mechanism detailsSeparate the moment couple and shear1 concept · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. A simplified moment connection assigns different actions to different fastener groups.
  2. Opposite flange forces separated by z resist moment: .
  3. The web fasteners or welds carry the assigned vertical shear in this model.
  4. Flange force, web shear, plate bearing and detailing each need their specified checks.

2. Trial 12mm flange fillets

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Use the same mechanism: A force couple carries moment. For the same moment, a larger lever arm requires a smaller couple force. It does not remove the web shear.

Apply the reasoning to this section’s data and conditions

Physical interpretation: How two flange forces make a moment

Two opposite forces form a turning pair, like two hands turning a wheel.

How two flange forces make a moment — Two opposite forces form a turning pair, like two hands turning a wheel.

Sketch, not to scale; use the original dimensions.

  1. Identify the separation between their actual force lines.
  2. Required force equals moment divided by that separation.
  3. Design the relevant flange group for that force.

Remember: The force-line separation is not automatically the overall section depth.

Related concept and full method

The source tries 12mm.

The available 150mm run loses 2s=24mm at its ends, leaving 126mm effective.

Use the printed weld run B, not the nominal 171mm section width.

Lflange,eff=150−2×12=126mmqflange=FLeff=249.589126=1.980862kNmmsneeded=1,000×1.9808620.7×250=11.3192mm12mm≥11.3192mm;qcap=0.7×12×2501,000=2.10kNmmFlange-weld resistance: 2.10×126=264.6kN>249.589Passes.

This also solves the implicit inequality 0.7pws(B−2s)1,000≥MD by a verified trial.

Increasing s improves throat but shortens effective length, so do not omit the recheck.

Mechanism detailsFrom fillet leg to effective throat2 concepts · 3 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat .

    It is shorter than the leg.

  3. Effective resisting area = .

    With here, capacity per length is .

  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.

3. Apply the required half-size rule and check shear

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Use the same mechanism: A force couple carries moment. For the same moment, a larger lever arm requires a smaller couple force. It does not remove the web shear.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Why the weld throat is smaller than its leg

The shortest cut through the weld is thinner than the outside leg.

Why the weld throat is smaller than its leg — The shortest cut through the weld is thinner than the outside leg.

Sketch, not to scale; use the original dimensions.

  1. For the stated equal-leg 90° fillet, throat is approximately 0.7 × leg.
  2. Multiply throat area by the matching weld design strength.
  3. For force per length, use a one-millimetre weld strip.

Remember: Choose strength from both the steel grade and electrode class.

Related concept and full method

sweb=122=6mmEffective length per weld: Lweb,eff=280−2×6=268mmTotal effective web-weld length: 2×268=536mmqweb=364536=0.679104kNmmsneeded,web=1,000×0.679104175=3.88060mmThe provided 6mm gives qcap=1.05kNmm; web-weld resistance: 536×1.05=562.8kN>364Passes.

Even though strength alone needs only about 3.9mm, use 6mm to satisfy the given relationship to the 12mm flange weld.

Mechanism detailsFrom fillet leg to effective throat2 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat .

    It is shorter than the leg.

  3. Effective resisting area = .

    With here, capacity per length is .

  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.

4. Check lengths and identify the remaining thickness condition

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Drawn length and useful length differ

The start and end of a weld are not credited as fully effective in this course model.

Drawn length and useful length differ — The start and end of a weld are not credited as fully effective in this course model.

Sketch, not to scale; use the original dimensions.

  1. Find the effective length required by strength.
  2. Add the specified end allowance to each separate run.
  3. Round up, then check minimum size, spacing and returns.

Remember: Strength alone does not prove a weld detail is acceptable.

Related concept and full method

Minimum effective flange-weld length: max(4×12,40)=48mm<126Minimum effective web-weld length: max(4×6,40)=40mm<268

The source dimensions describe weld runs on the cut bracket, not a licence to infer other fabrication details from scale.

The supporting column thickness is not stated.

The result therefore establishes flange/web weld strength and the size ratio; applicability of the thicker-part minimum-size rule to the support must be confirmed separately.

Mechanism detailsFrom fillet leg to effective throat2 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat .

    It is shorter than the leg.

  3. Effective resisting area = .

    With here, capacity per length is .

  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.

Result and concise exam wording

Use the same mechanism: A force couple carries moment. For the same moment, a larger lever arm requires a smaller couple force. It does not remove the web shear.

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

P=364kN,M=91kN·m.

About X1–X1, flange force=249.589kN.12mm flange weld has 126mm effective length and 264.6kN resistance.6mm web welds each have 268mm effective length, combined resistance 562.8kN.

Both pass and web leg is half flange leg.

Support thickness for minimum weld-size verification is not supplied.

Misconceptions and checks

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

  • The moment arm D is 364.6mm.

    The web run a is 280mm.

    They are not interchangeable.

  • Use two web welds.

    However, the source’s tension-flange force is resisted by the specified flange run.

  • Subtract 2s using that run’s own leg size.

How the method transfers to a new variant

Use the same mechanism: A force couple carries moment. For the same moment, a larger lever arm requires a smaller couple force. It does not remove the web shear.

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

  1. Identify the source pivot and the flange-force arm.
  2. Factor load and calculate moment/force couple.
  3. Try a flange leg, calculate its effective length and verify capacity.
  4. Apply the specified web/flange size relationship and check web shear.
  5. Check effective-length/detailing rules and state unprovided support data.

Prediction with explained answer

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

Prediction and explained answer.

Keep the selected welds and increase the eccentricity to 300mm.

What happens to the flange strength check?

Answer and reasoning

Flange force becomes 364×300364.6=299.506kN, greater than 264.6kN.

The flange weld fails while the unchanged direct web shear remains 364kN and still passes.

Mechanism detailsSeparate the moment couple and shear2 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. A simplified moment connection assigns different actions to different fastener groups.
  2. Opposite flange forces separated by z resist moment: .
  3. The web fasteners or welds carry the assigned vertical shear in this model.
  4. Flange force, web shear, plate bearing and detailing each need their specified checks.

Mechanism detailsA weld group is a set of lines1 concept · 5 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. The centre is empty: resistance comes from the weld lines, not a solid plate filling the group.
  2. Use line lengths for centroid weighting.

    Line second moments have units .

    Add the parallel-axis terms.

  3. Direct force per length is .

    The eccentric moment adds tangential flow proportional to distance from the centroid.

  4. Combine signed components at every candidate corner, then compare the maximum with throat resistance per length.

Practise this chapter: tutorials, assignments and past-paper answers →

Older-paper answers for this chapter (reference)