STEELWORK / CON4334
Past papers

2023 past paper: complete solution navigator

← Worked Examples: answers by chapter or year

All answers shownChinese–English terminology

Original paper: Pastpaper/22ENGTY033.pdf.

All 16 printed subquestions have a teaching solution linked below.

Read the source diagram together with the calculation.

Each linked lesson presents its method, full working and answer.

Printed examination format

Time allowed: 2 hours.

Answer compulsory Section A (40 marks) and any TWO Section B questions (30 marks each).

Required total: 100 marks; 130 marks are offered.

The printed marks below are official question allocations.

No official worked solutions or marking schemes were supplied.

Every model solution, method-mark suggestion and exam strategy on this website is independently written teaching guidance.

p. 1

Suggested time plan.

This is teaching guidance, not an official rule.

Allow 5 minutes to read and choose questions.

Allow 42 minutes for Section A.

Allow 32 minutes for each selected Section B question.

Allow 9 minutes to check units, omissions and conclusions.

Section A Q1: floor beams and short theory

Follow one strip of floor

An area load must become a beam load before beam reactions can be calculated.

The highlighted tributary strip supplies one beam. The right-hand labels show area load multiplied by width becoming line load.
The highlighted tributary strip supplies one beam. The right-hand labels show area load multiplied by width becoming line load.

Prediction, then explanation. At fixed area load, twice the tributary width gives twice the line load. An end reaction remains a concentrated force.

Consider one metre along the beam. The associated floor area is b square metres. Multiply area load by that width.

w=qbw=qb

q is area load in kN/m²; b is tributary width in m; w is line load in kN/m.

Scope. Determine b from slab spanning and supports. Add beam self-weight separately. A secondary-beam reaction is not automatically a UDL.

Check and takeaway. Illustration: 3 kN/m2×2 m=6 kN/m3\,\mathrm{kN/m^2}\times2\,\mathrm{m}=6\,\mathrm{kN/m}. The width cancels one length unit.

Keep load categories separate

A floor carries permanent material and changing occupancy loads. Find the design load for the stated check.

The two boxes show G and Q with their separate factors. The plus sign joins their factored values.
The two boxes show G and Q with their separate factors. The plus sign joins their factored values.

Prediction, then explanation. Increasing imposed load changes its own term. It does not change the dead-load factor or the steel stiffness.

First convert mass to weight where required. Next collect G and Q in compatible units. Apply the combination specified by the course problem.

Wu=1.4G+1.6QW_u=1.4G+1.6Q

G is characteristic dead load; Q is characteristic imposed load. Wu is the design load for this course gravity combination.

Scope. This combination is not universal. Use the specified service load for deflection and the stated factors for other standards or cases.

Check and takeaway. Illustration: G = 10 kN and Q = 5 kN give 22 kN. Factoring their sum by one guessed factor loses the distinction.

Apply the reasoning to this section’s data and conditions

Section B Q2: connections

Count cuts through each loaded bolt

Find how many shear planes transfer the force through one side of the connection.

The middle plate moves against two cover plates. The two interfaces cut each bolt at two planes.
The middle plate moves against two cover plates. The two interfaces cut each bolt at two planes.

Prediction, then explanation. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Select the area at the actual shear plane. Multiply by bolt shear strength. Count only the bolts and planes in the same transfer stage.

Ps=psAs,Pgroup=nbnsPsP_s=p_sA_s,\qquad P_{group}=n_b n_s P_s

ps is bolt shear strength in N/mm²; As is the appropriate area in mm². nb counts bolts; ns counts equally loaded shear planes.

Scope. Use the thread area when threads cross the plane as required. Check bearing, plate failure and detailing separately.

Check and takeaway. Both halves of a butt splice carry the full transmitted force in sequence. Counting both halves together would double the apparent resistance.

The weld resists through its throat

Convert a visible fillet leg into resistance per effective length.

The two outer sides are the legs. The shorter perpendicular line through the ideal triangle is the throat.
The two outer sides are the legs. The shorter perpendicular line through the ideal triangle is the throat.

Prediction, then explanation. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

For the course right-angle equal-leg fillet, take throat as 0.7 times leg. Multiply throat area per unit length by weld strength.

a=0.7s,qcap=0.7spw/1000a=0.7s,\qquad q_{cap}=0.7sp_w/1000

s and a are leg and throat in mm. pw is weld strength in N/mm². qcap is resistance in kN/mm.

Scope. Use effective length, the correct steel/electrode strength and permitted leg limits. Full-penetration butt welds use a different model.

Check and takeaway. Illustration: a 6 mm leg at 250 N/mm² gives 0.7(6)(250)/1000=1.05 kN/mm0.7(6)(250)/1000=1.05\,\mathrm{kN/mm}.

Apply the reasoning to this section’s data and conditions

PartTask / full teaching solutionPrinted marks
b 2-aiDouble welded angle tension capacity6
b 2-aiiFinal weld lengths9
b 2-biBolt shear and tension capacities5
b 2-biiBracket bolt adequacy10

Section B Q3: columns

A strong cross-section can belong to an unstable member

A column carries axial compression and bending. Explain why more than one check is required.

The three boxes name separate checks: Section, Flexural and LTB. The bottom caption explains that passing one does not pass the others.
The three boxes name separate checks: Section, Flexural and LTB. The bottom caption explains that passing one does not pass the others.

Prediction, then explanation. At fixed moments and resistances, increasing compression increases utilisation. A section pass cannot remove the length-dependent instability checks.

Separate cross-section, flexural-buckling and LTB interaction equations. Use each equation’s own denominators and first-order or amplified moments.

AgpyA_g p_y is a section axial resistance. AgpcA_g p_c is a member compression resistance. Elastic pyZp_y Z and prescribed McM_c are different bending denominators.

Scope. Preserve the course barred-moment definitions and Eq. 8.81 convention. Do not substitute plastic moduli into an elastic denominator.

Check and takeaway. Report each requested utilisation and the governing check. The largest properly calculated ratio identifies the closest limit.

Apply the reasoning to this section’s data and conditions

PartTask / full teaching solutionPrinted marks
b 3-aColumn class4
b 3-bColumn cross-section capacity6
b 3-cColumn member buckling20

Section B Q4: unrestrained beams

Vertical bending can trigger sideways motion

A beam has enough local bending resistance. Check whether its compression flange can move sideways and twist.

The dashed straight line is the initial reference. The curved flange lines illustrate the labelled sideways movement and twist.
The dashed straight line is the initial reference. The curved flange lines illustrate the labelled sideways movement and twist.

Prediction, then explanation. Adding a valid lateral restraint shortens a stability segment. It need not change the beam’s vertical reaction or moment diagram.

Identify the compressed flange and effective restraints. Calculate the specified slenderness, read buckling strength and compare resistance with the segment demand.

λ=LE/ry,Mb=pbSx  (Class 1/2),mLTMmax≤Mb\lambda=L_E/r_y,\qquad M_b=p_bS_x\;\text{(Class 1/2)},\qquad m_{LT}M_{max}\le M_b

LE and ry use the same length unit. pb uses N/mm²; Sx uses mm³; Mb uses N·mm. mLT is dimensionless.

Scope. Use the specified section class, effective-length branch and loading condition. Load height alone does not prove a destabilizing case.

Check and takeaway. Removing a lateral restraint requires a new segment stability check. The old shorter-segment result cannot establish the longer segment’s adequacy.

Moment shape matters within one segment

Represent a nonuniform moment distribution in the applicable member-buckling equation.

The two diagrams have equal peaks. The left high-moment region is short; the right high-moment region extends across more of the segment.
The two diagrams have equal peaks. The left high-moment region is short; the right high-moment region extends across more of the segment.

Prediction, then explanation. Two segments can have equal peak moment but different distributions. Their equivalent moment factors can therefore differ.

Evaluate moments from the true whole-beam analysis at the required positions. Apply the exact table’s weights, signs and lower bound.

mLT is an LTB factor. mx and my belong to the specified flexural checks. They are not interchangeable.

Scope. Some rules use magnitudes; others require signed ordinates. A factor does not reduce the actual moment used in a local section check.

Check and takeaway. Measure quarter points from the segment start, not automatically from the beam’s left support.

Apply the reasoning to this section’s data and conditions

PartTask / full teaching solutionPrinted marks
b 4-aBeam shear and moment2
b 4-bBeam LTB with support restraints14
b 4-cBeam LTB with added midspan restraint14

Review an attempt

Make the next decision from the known conditions

Read the specific task below and identify the quantity or explanation it asks for.

ConditionsModelCalculationCheckA changed condition can change the method.
The sequence links source conditions, a physical model, a calculation and a checked conclusion. Each link needs the previous one.

Prediction, then explanation. Changing a load value may preserve the method. Changing the support or failure mechanism can require a different method.

Separate given, lookup, calculated and assumed values. State why the model applies. Keep necessary intermediate steps and units beside the equations.

A conditional answer states the exact condition required for its conclusion. It does not fill missing data with a guess.

Scope. A repeated result is not an independent verification. Use equilibrium, dimensions, a reverse substitution or an appropriate limiting case.

Check and takeaway. The explanation and answer are shown together in this edition. No response, score or completed interaction is needed to continue.

Apply the reasoning to this section’s data and conditions

  1. Mark incorrect decisions separately from arithmetic slips: wrong load factor, wrong support span, wrong restraint, wrong table, wrong units.
  2. The first incorrect line identifies where the method fails.

    Every later line that depends on it must be recalculated.

  3. A changed-input example tests the same method.

    Its prediction explains whether the result should rise or fall before the calculation confirms the change.

  4. Record conditional assumptions and missing data.

    A plausible answer must not become a fabricated official answer.

Graduated practice and unseen variants · A new timed mock in the supplied format