STEELWORK / CON4334
Worked examples

2023 AQ1: compulsory floor-beam design and theory

Diagrams, explanations and answers are presented in reading order. No playback or response is required.
All answers shownChinese–English terminology
Diagrams, explanations and answers are presented in reading order. No playback or response is required.

Complete the 40-mark compulsory question. Slab thickness 125mm, concrete unit weight 24.5kNm3, finishes 0.5kNm2, imposed load 2.5kNm2. B1 is 356×127×39 UB and B2 as 356×171×51 UB, all S355. Include self-weight using g=10ms2. The beams are simply supported, fully laterally restrained and carry brittle finishes.

Original source: Pastpaper/22ENGTY033.pdf — p. 2.

A given value comes from the question or diagram.

A lookup value comes from the named table.

A calculated value follows from the working.

Each assumption is stated where the calculation needs it.

Known information, diagram labels and unknowns

Vertical bending can trigger sideways motion

A beam has enough local bending resistance. Check whether its compression flange can move sideways and twist.

The dashed straight line is the initial reference. The curved flange lines illustrate the labelled sideways movement and twist.
The dashed straight line is the initial reference. The curved flange lines illustrate the labelled sideways movement and twist.

Prediction, then explanation. Adding a valid lateral restraint shortens a stability segment. It need not change the beam’s vertical reaction or moment diagram.

Identify the compressed flange and effective restraints. Calculate the specified slenderness, read buckling strength and compare resistance with the segment demand.

λ=LE/ry,Mb=pbSx  (Class 1/2),mLTMmax≤Mb\lambda=L_E/r_y,\qquad M_b=p_bS_x\;\text{(Class 1/2)},\qquad m_{LT}M_{max}\le M_b

LE and ry use the same length unit. pb uses N/mm²; Sx uses mm³; Mb uses N·mm. mLT is dimensionless.

Scope. Use the specified section class, effective-length branch and loading condition. Load height alone does not prove a destabilizing case.

Check and takeaway. Removing a lateral restraint requires a new segment stability check. The old shorter-segment result cannot establish the longer segment’s adequacy.

Follow one strip of floor

An area load must become a beam load before beam reactions can be calculated.

The highlighted tributary strip supplies one beam. The right-hand labels show area load multiplied by width becoming line load.
The highlighted tributary strip supplies one beam. The right-hand labels show area load multiplied by width becoming line load.

Prediction, then explanation. At fixed area load, twice the tributary width gives twice the line load. An end reaction remains a concentrated force.

Consider one metre along the beam. The associated floor area is b square metres. Multiply area load by that width.

w=qbw=qb

q is area load in kN/m²; b is tributary width in m; w is line load in kN/m.

Scope. Determine b from slab spanning and supports. Add beam self-weight separately. A secondary-beam reaction is not automatically a UDL.

Check and takeaway. Illustration: 3 kN/m2×2 m=6 kN/m3\,\mathrm{kN/m^2}\times2\,\mathrm{m}=6\,\mathrm{kN/m}. The width cancels one length unit.

Change the ruler, keep the quantity

A section table uses centimetres, but the strength calculation uses millimetres. The numbers must describe the same section.

Length1 factorArea2 factors3 factorsEach centimetre becomes ten millimetres.
In the diagram, the length, square and cube contain one, two and three length factors. Each factor changes when the ruler changes.

Prediction, then explanation. Would every property increase by ten? No. The exponent determines how many factors of ten are needed.

First identify the physical quantity. Next convert each length factor. Keep force and length conversions separate when converting a moment.

1 cmn=10n mmn,1 kN m=106 N mm1\,\mathrm{cm}^n=10^n\,\mathrm{mm}^n,\qquad 1\,\mathrm{kN\,m}=10^6\,\mathrm{N\,mm}

Here n is the length exponent: 2 for area, 3 for section modulus and 4 for second moment of area.

Scope. Changing units changes neither the load nor the section. A conversion factor cannot repair a formula for the wrong physical quantity.

Check and takeaway. Illustration: 2 cm4=20,000 mm42\,\mathrm{cm}^4=20{,}000\,\mathrm{mm}^4. The fourth power belongs to the unit, not the number 2.

Apply the reasoning to this section’s data and conditions

Input typeExact source feature
Given slab dataQuestion paragraph:125mm thickness,24.5 unit weight,finish 0.5,imposed 2.5.
Given supports/spans

Dimension chains and column symbols inFigureAQ1.

Use the explanation alongside the original crop.

Calculated widthsInterior B1 tributary width 2.52+2.52=2.5m.
Lookup self-weight

Data File p.9 gives B1 mass 39.1kgm;B2 mass 51kgm.

Nominal section labels may round the mass.

Method applicability

Slab is expressly a full lateral restraint.

No composite-section enhancement is assumed.

Why this method applies

Find which plate buckles first

Before using plastic bending resistance, check whether the flange and web can sustain the required stress distribution.

The short waves are local plate buckling. They differ from sideways movement of the whole member.
The short waves are local plate buckling. They differ from sideways movement of the whole member.

Prediction, then explanation. At fixed width, a thinner plate has a larger width-to-thickness ratio. Local buckling then becomes more restrictive.

Calculate the flange and web ratios separately. Compare each with the limits for its stress condition. The worse class governs.

ε=275/py\varepsilon=\sqrt{275/p_y}

py is the design yield strength in N/mm². ε is a dimensionless scale used in the supplied classification limits.

Scope. Pure bending and uniform compression use different web limits. Class 2 allows plastic resistance but not the Class 1 rotation capability.

Check and takeaway. A Class 1 web and Class 2 flange give a Class 2 section. Do not average the class numbers.

A safe beam can still sag too far

Check whether the beam displacement exceeds the permitted service limit.

The straight beam marks the unloaded position. The curved line and vertical arrow show downward displacement, exaggerated for explanation.
The straight beam marks the unloaded position. The curved line and vertical arrow show downward displacement, exaggerated for explanation.

Prediction, then explanation. For the same UDL and stiffness, doubling span multiplies deflection by sixteen. Doubling I halves deflection.

Load bends each beam segment. The curvature accumulates along the span. Material stiffness E and geometric stiffness I resist that deformation.

δmid=5wL4384EI\delta_{mid}=\frac{5wL^4}{384EI}

Use w in N/mm, L in mm, E in N/mm² and I in mm⁴. The resulting midspan deflection is in mm.

Scope. The formula assumes a prismatic, simply supported, linear-elastic beam with full-span UDL. Use the stated service load and deflection limit.

Check and takeaway. A higher yield grade does not automatically increase E. Passing a strength check therefore does not prove acceptable deflection.

Use the same mechanism: Follow one strip of floor. At fixed area load, twice the tributary width gives twice the line load. An end reaction remains a concentrated force.

Apply the reasoning to this section’s data and conditions

The load follows a physical path.

Slab intensity becomes a beam line load through tributary width.

Beam reactions then load the supporting beam.

Classify the section before checking shear, bending and imposed-load deflection.

Work from the actual plan orientation.

The names B1/B2 alone do not tell you which way a beam spans.

(a)(i) Slab factored intensity —4 printed marks

Keep load categories separate

A floor carries permanent material and changing occupancy loads. Find the design load for the stated check.

The two boxes show G and Q with their separate factors. The plus sign joins their factored values.
The two boxes show G and Q with their separate factors. The plus sign joins their factored values.

Prediction, then explanation. Increasing imposed load changes its own term. It does not change the dead-load factor or the steel stiffness.

First convert mass to weight where required. Next collect G and Q in compatible units. Apply the combination specified by the course problem.

Wu=1.4G+1.6QW_u=1.4G+1.6Q

G is characteristic dead load; Q is characteristic imposed load. Wu is the design load for this course gravity combination.

Scope. This combination is not universal. Use the specified service load for deflection and the stated factors for other standards or cases.

Check and takeaway. Illustration: G = 10 kN and Q = 5 kN give 22 kN. Factoring their sum by one guessed factor loses the distinction.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Why dead and imposed loads stay separate

Keep permanent load and imposed load separate until their respective factors have been applied.

Why dead and imposed loads stay separate — Keep two shopping baskets until their different multipliers are applied.

Sketch, not to scale; use the original dimensions.

  1. Include self-weight and permanent finishes in permanent load.
  2. Include the specified occupancy load in imposed load.
  3. For this course’s stated gravity combination: 1.4G+1.6Q.

Remember: That ULS combination is not the imposed-load deflection load.

Related concept and full method

Slab thickness: 125mm=0.125mConcrete dead load: 0.125×24.5=3.0625kNm2gk=3.0625+0.5=3.5625kNm2qk=2.5kNm2Ultimate area load: 1.4×3.5625+1.6×2.5=8.9875kNm2

Concrete unit weight is in kNm3, so multiply by slab thickness in metres to obtain kNm2.

A surface intensity is not yet a beam line load.

The next step supplies the tributary width.

Mechanism detailsFrom characteristic to design load1 concept · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. G is permanent load; Q is imposed load.

    A surface load and a line load also have different units.

  2. This illustration uses the course gravity case .

    Other combinations in the original text retain their own factors.

  3. For illustrative , the separate load contributions show what changes when Q increases.
  4. Do not carry this ULS total automatically into deflection.

    Follow the stated SLS load case.

(a)(ii) Both beam actions —8 printed marks

Use the same mechanism: Follow one strip of floor. At fixed area load, twice the tributary width gives twice the line load. An end reaction remains a concentrated force.

Use the same mechanism: Keep load categories separate. Increasing imposed load changes its own term. It does not change the dead-load factor or the steel stiffness.

Balance the isolated beam

Find the two vertical reactions before calculating internal shear or moment.

A / RₐB / RᵦPaL
A and B are vertical supports. The downward load acts at distance a from A. Its distance from B is L − a.

Prediction, then explanation. Move the same load toward B. Reaction B increases because the load has a larger moment arm about A.

Take moments about A. Reaction A has zero lever arm there. Then use vertical force balance to find reaction A.

RBL=Pa,RA+RB=PR_B L=Pa,\qquad R_A+R_B=P

P, RA and RB are forces in kN. L is support spacing and a is load position, both in m.

Scope. These expressions describe one point load on a simply supported beam. Add other loads through equilibrium; keep their actual positions.

Check and takeaway. Illustration: P = 60 kN, L = 6 m and a = 2 m give RB = 20 kN and RA = 40 kN.

Apply the reasoning to this section’s data and conditions

Physical interpretation: How a floor load reaches a beam

Each beam collects the load from its own strip of floor.

How a floor load reaches a beam — Each beam collects the load from its own strip of floor.

Sketch, not to scale; use the original dimensions.

  1. Find the tributary width from the actual plan.
  2. Area load × tributary width gives load per beam length.
  3. A supporting beam receives the other beam’s end reaction.

Remember: A reaction becomes a point load, not automatically a UDL.

Related concept and full method

B1:

Tributary width: 2.52+2.52=2.5mB1 self-weight: 39.1kgm×10ms21,000=0.391kNmDead line load: 3.5625×2.5+0.391=9.297250kNmImposed line load: 2.5×2.5=6.25kNmUltimate line load: w=1.4×9.297250+1.6×6.25=23.016150kNmReaction at each end: R=wL2=23.016150×72=80.556525kNVmax=R=80.556525kNShear V(x)=R−wx lie on opposite sides of the x=3.5m is zero at this position.Mmax=wL28=23.016150×728=140.973919kN·m

Here 39kgm is the nominal designation.

The exact section-table mass is 39.1kgm.

Use one stated convention consistently.

B1’s vertical support spacing is 7m even though the slab tributary width is 2.5m.

B2:

Each B2 receives one B1 end reaction at midspan, P=80.556525kN. B2 self-weight: 51×101,000=0.51kNmB2 ultimate UDL: w=1.4×0.51=0.714kNmSpan: L=2.5+2.5=5mReaction at each end: R=P2+wL2=80.5565252+0.714×52=42.063262kNVmax=42.063262kNMmax=PL4+wL28=80.556525×54+0.714×528=102.926906kN·m

The transferred P is already factored.

Do not factor it again.

Only B2 self-weight forms the full-span UDL here.

One-way slab loads reach B2 through B1 or through supported end joints.

Keep those load positions in the model.

Mechanism detailsFollow the floor load in 3D4 concepts · 2 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. The floor carries pressure in .

    The highlighted strip belongs to one secondary beam.

  2. Multiply pressure by tributary width: .

    The illustration uses .

  3. A primary beam receives the secondary beam reaction at their connection, not a new full-span UDL.
  4. Trace reactions down to columns and foundations.

    Count each loaded area once.

(a)(iii) Both section classes —4 printed marks

Use the same mechanism: Find which plate buckles first. At fixed width, a thinner plate has a larger width-to-thickness ratio. Local buckling then becomes more restrictive.

Apply the reasoning to this section’s data and conditions

Physical interpretation: A thin part can wrinkle first

A thin plate may wrinkle before the whole steel member reaches its intended resistance.

A thin part can wrinkle first — A thin plate may wrinkle before the whole steel member reaches its intended resistance.

Sketch, not to scale; use the original dimensions.

  1. Check flange and web slenderness using their own definitions.
  2. Compare each ratio with the correct class limits.
  3. The element with the more restrictive class determines the section class.

Remember: Bending limits and uniform-compression limits are different.

Related concept and full method

Lookup: Data File pp.9–10, exact 356×127×39 UB row.

Dimensions on p.9; properties on p.10.

D is overall depth.

d is the clear web depth between root fillets, not the nominal designation.

PropertyLookup value / conversion
DimensionsD353.4, web t 6.6, flange T10.7, root r 10.2, clear d 311.6, all mm
Local ratiosbT=5.89;dt=47.2。
Major-axis propertiesIx=10170cm4=1.017×108mm4; Zx=576cm3; Sx=659cm3.
LTB propertiesry=2.68cm=26.8mm; u=0.871; torsional index x=35.2.
S355, flange T=10.7mm, giving py=355Nmm2. ε=275355=0.880141Flange: bT=5.89<9ε=7.921268Web in bending: dt=47.2<80ε=70.411267Both are Class 1, so βW=1; plastic bending resistance is permitted.dt=47.2<70ε=61.609858No separate shear-buckling calculation is needed under the course limit.

Lookup: Data File pp.9–10, exact 356×171×51 UB row.

Dimensions on p.9; properties on p.10.

D is overall depth.

d is the clear web depth between root fillets, not the nominal designation.

PropertyLookup value / conversion
DimensionsD355, web t 7.4, flange T11.5, root r 10.2, clear d 311.6, all mm
Local ratiosbT=7.46;dt=42.1。
Major-axis propertiesIx=14140cm4=1.414×108mm4; Zx=797cm3; Sx=896cm3.
LTB propertiesry=3.86cm=38.6mm; u=0.881; torsional index x=32.1.
S355, flange T=11.5mm, giving py=355Nmm2. ε=275355=0.880141Flange: bT=7.46<9ε=7.921268Web in bending: dt=42.1<80ε=70.411267Both are Class 1, so βW=1; plastic bending resistance is permitted.dt=42.1<70ε=61.609858No separate shear-buckling calculation is needed under the course limit.

Both beams are Class 1.

No Class 4 effective-property calculation is needed.

Full slab lateral restraint, given in the paper, removes the LTB requirement for these floor-beam questions.

It does not remove local shear/bending or deflection checks.

Mechanism detailsWhy thin elements buckle locally1 concept · 18 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. The flange outstand and web have different widths, thicknesses and edge support conditions.
  2. A thinner plate can wrinkle locally before the complete member loses stability.
  3. Class 1 allows plastic rotation.

    Class 2 reaches plastic resistance.

    Class 3 reaches elastic resistance.

    Class 4 requires effective properties.

  4. Check every relevant compression element with the supplied limits and stress distribution.

    The deformation shown is qualitative.

(a)(iv) B1 adequacy —10 printed marks

The web carries the shear check

Compare the applied shear with the resistance of the prescribed shear area.

At the imaginary cut, opposing arrows resist relative sliding. The rolled-UB calculation below assigns the shear area to the web.
At the imaginary cut, opposing arrows resist relative sliding. The rolled-UB calculation below assigns the shear area to the web.

Prediction, then explanation. At fixed design strength and depth, increasing web thickness increases this shear resistance.

Calculate the prescribed shear area. Multiply by the design shear stress from the course rule. Then compare matching force units.

Av=Dt,Vc=pyAv/3A_v=Dt,\qquad V_c=p_yA_v/\sqrt{3}

D is overall depth; t is web thickness, in mm. Av uses mm². py uses N/mm², giving Vc in N.

Scope. Apply this area definition to the stated rolled section. Check web slenderness separately. The factor 0.6 is the low-shear threshold, not this resistance coefficient.

Check and takeaway. A shear pass alone does not prove bending, deflection or local support-web adequacy.

Internal tension and compression resist moment

Find which section resistance applies before comparing it with the moment demand.

In sagging bending, the upper region compresses and the lower region stretches. Together their forces form a resisting couple.
In sagging bending, the upper region compresses and the lower region stretches. Together their forces form a resisting couple.

Prediction, then explanation. A larger appropriate section modulus raises resistance at fixed strength. Local plate buckling can restrict the usable modulus.

Classify the section first. At low shear, use the elastic expression for Class 3 or the prescribed capped plastic expression for Classes 1 and 2.

Mc=min⁡(pyS,1.2pyZ)for Class 1/2 at low shearM_c=\min(p_yS,1.2p_yZ)\quad\text{for Class 1/2 at low shear}

py uses N/mm². S is plastic modulus and Z is elastic modulus, both in mm³. Mc then uses N·mm.

Scope. This is section resistance, not whole-member LTB resistance. High shear and Class 4 require their appropriate treatment.

Check and takeaway. Selecting the larger of the two capped terms defeats the cap. Use their minimum.

Shear and bending share the web

Decide whether the unreduced bending resistance remains applicable at the section being checked.

The same web region participates in shear and longitudinal bending stress. The two demands must be evaluated at one section.
The same web region participates in shear and longitudinal bending stress. The two demands must be evaluated at one section.

Prediction, then explanation. Raising shear beyond the specified threshold can reduce available bending resistance. A distant maximum shear is not the coexistent shear.

Find the moment-check position. Evaluate the shear there. Compare it with the low-shear threshold before selecting the resistance expression.

V≤0.6Vcis the course low-shear conditionV\le0.6V_c\quad\text{is the course low-shear condition}

V is shear at the checked section; Vc is its shear resistance. Both use the same force unit.

Scope. Above the threshold, use the supplied reduction expression. The threshold itself is not a substitute resistance formula.

Check and takeaway. If the maximum shear anywhere is below the threshold, all sections satisfy that low-shear condition. Otherwise check the actual positions.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Why one flange squeezes and the other stretches

Bending makes opposite sides of the section do opposite jobs.

Why one flange squeezes and the other stretches — Bending makes opposite sides of the section do opposite jobs.

Sketch, not to scale; use the original dimensions.

  1. Find the moment from the actual loads and supports.
  2. Choose the resistance formula allowed by the section class.
  3. Check whether the coexistent shear changes that formula.

Remember: Use shear at the location being checked, not an unrelated maximum.

Related concept and full method

Av=tD=6.6×353.4=2332.44mm2Vc=pyAv3=355×2332.443×1,000=478.055376kNVmax=80.556525kN<VcShear passes.0.6Vc=286.833226kN>VmaxEven peak shear is low, so the low-shear bending expression applies throughout the beam.Mc=min(pySx,1.2pyZx)=min(355×6591,000,1.2×355×5761,000)=min(233.945,245.376)=233.945kN·m|M|max=140.973919kN·mBending passes.
B1 imposed line load: q=2.5×2.5=6.25kNm=6.25NmmL=7,000mmE=205,000Nmm2Ix=10,170×104mm4δB1=5qL4384EI=5×6.25×7,0004384×205,000×10,170×104=9.372083mmBrittle-finish limit: 7,000360=19.444444mm9.372083<19.444444: passes.

Mechanism detailsSee shear in the web4 concepts · 2 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Internal shear keeps the two sides of the cut in vertical equilibrium.
  2. For the course’s common I-section case, the web provides the principal shear area.

    Use the specified definition.

  3. A slender web may require a different shear-buckling route before a simple shear-resistance formula is used.
  4. Use where applicable in the course.

    Convert N to kN before comparing with design shear.

(a)(v) B2 adequacy —10 printed marks

Use the same mechanism: The web carries the shear check. At fixed design strength and depth, increasing web thickness increases this shear resistance.

Use the same mechanism: Internal tension and compression resist moment. A larger appropriate section modulus raises resistance at fixed strength. Local plate buckling can restrict the usable modulus.

Use the same mechanism: Shear and bending share the web. Raising shear beyond the specified threshold can reduce available bending resistance. A distant maximum shear is not the coexistent shear.

Apply the reasoning to this section’s data and conditions

Physical interpretation: How much does the beam sag?

Strength asks whether it fails; deflection asks how far it moves.

How much does the beam sag? — Strength asks whether it fails; deflection asks how far it moves.

Sketch, not to scale; use the original dimensions.

  1. Use the serviceability load case specified by the course question.
  2. Choose the expression matching the support and load positions.
  3. Use consistent units for load, length, E and I.

Remember: The largest deflection is not always at midspan.

Related concept and full method

Av=tD=7.4×355=2627mm2Vc=pyAv3=355×26273×1,000=538.428201kNVmax=42.063262kN<VcShear passes.0.6Vc=323.056920kN>VmaxEven peak shear is low, so the low-shear bending expression applies throughout the beam.Mc=min(pySx,1.2pyZx)=min(355×8961,000,1.2×355×7971,000)=min(318.08,339.522)=318.08kN·m|M|max=102.926906kN·mBending passes.
B1 reaction delivered to B2, imposed load only: Pq=(2.5×2.5)×72=21.875kNL=5,000mmIx=14,140×104mm4δB2=PL348EI=21875×5,000348×205,000×14,140×104=1.965231mmBrittle-finish limit: 5,000360=13.888889mm1.965231<13.888889: passes.

Mechanism detailsSee shear in the web4 concepts · 2 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Internal shear keeps the two sides of the cut in vertical equilibrium.
  2. For the course’s common I-section case, the web provides the principal shear area.

    Use the specified definition.

  3. A slender web may require a different shear-buckling route before a simple shear-resistance formula is used.
  4. Use where applicable in the course.

    Convert N to kN before comparing with design shear.

(b) Two corrosion-protection methods —4 printed marks

Interrupt the corrosion process

Steel exposed to moisture and oxygen can lose material. Explain what each protection system does.

SteelCoatingExposed gapBarrier intact / barrier interrupted
The coating surrounds the steel. A break in the coating exposes a local path to the steel surface.

Prediction, then explanation. If a barrier coating is damaged, the exposed region can corrode. Zinc can also provide sacrificial protection where conditions permit.

Paint works mainly as a barrier. Galvanizing adds a zinc layer with barrier and sacrificial effects. Surface preparation affects performance.

No universal coating thickness or life follows from this mechanism sketch.

Scope. Weathering steel still needs suitable exposure and detailing. A protection label does not replace inspection or maintenance.

Check and takeaway. The useful comparison is the protection mechanism, exposure and maintenance need. Do not describe all coatings as identical barriers.

Apply the reasoning to this section’s data and conditions

Protective paint/coating system: prepare the steel surface, then apply and maintain a suitable protective coating to isolate steel from water/oxygen.

Explain the barrier mechanism; merely saying “paint” omits why it helps.

Galvanizing: apply a zinc coating, which provides a barrier and sacrificial protection because the zinc preferentially corrodes.

Identify zinc explicitly.

It is not a generic colour finish.

These two methods correspond to the course corrosion discussion in Ch 1 p.2.

Keep drainage/moisture-trap avoidance as a useful detailing addition, not an unsupported substitute for explaining the two requested methods.

No coating thickness or maintenance interval is specified in the paper.

Mechanism detailsHow corrosion protection works1 concept

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Corrosion can consume steel and reduce its effective thickness.
  2. Paint and metallic coatings protect the exposed surface; coating integrity matters.
  3. Edges, damaged coatings and water-trapping details deserve attention.

    The model shows layers schematically.

  4. Weathering steel and cathodic protection have specific environmental applications; they are not universal substitutes for paint.

Result and concise exam wording

Use the same mechanism: Find which plate buckles first. At fixed width, a thinner plate has a larger width-to-thickness ratio. Local buckling then becomes more restrictive.

Use the same mechanism: A safe beam can still sag too far. For the same UDL and stiffness, doubling span multiplies deflection by sixteen. Doubling I halves deflection.

Use the same mechanism: Change the ruler, keep the quantity. Would every property increase by ten? No. The exponent determines how many factors of ten are needed.

Apply the reasoning to this section’s data and conditions

ResultB1B2
Ultimate line self/floor modelw=23.016150kNmP=80.556525kN;w=0.714kNm
Maximum shear80.556525kN42.063262kN
Maximum moment140.973919kN·m102.926906kN·m
Section class11
Imposed deflection / limit9.372083/19.444444mm1.965231/13.888889mm
Requested adequacyPassPass

Slab gk=3.5625,qk=2.5,ultimate=8.9875kNm2.

Use the theory explanations above for the 4-mark final part.

A concise script should still show units, the plastic ceiling and the serviceability load choice.

Misconceptions and checks

Use the same mechanism: A safe beam can still sag too far. For the same UDL and stiffness, doubling span multiplies deflection by sixteen. Doubling I halves deflection.

Apply the reasoning to this section’s data and conditions

  • Do not read a slab bay width as the supporting beam span.
  • Do not double-factor a transferred reaction.
  • Do not use design load in an imposed-only deflection equation.
  • Do not confuseI(cm4),Z(cm3) andS(cm3).
  • Passing bending does not prove that deflection passes.

How the method transfers to a new variant

Use the same mechanism: Find which plate buckles first. At fixed width, a thinner plate has a larger width-to-thickness ratio. Local buckling then becomes more restrictive.

Use the same mechanism: A safe beam can still sag too far. For the same UDL and stiffness, doubling span multiplies deflection by sixteen. Doubling I halves deflection.

A cut reveals the internal actions

Find where the beam moment is largest. A large load arrow alone does not locate that point.

The dashed imaginary cut separates two beam pieces. The opposing arrows represent the shear action between those pieces.
The dashed imaginary cut separates two beam pieces. The opposing arrows represent the shear action between those pieces.

Prediction, then explanation. Under a uniform downward load, shear falls steadily. Moment reaches a stationary value where shear becomes zero.

Balance the forces on the cut piece to get V. Balance their moments about the cut to get M. Evaluate each load region separately.

V(x)=RA−wx,M(x)=RAx−wx22V(x)=R_A-wx,\qquad M(x)=R_Ax-\frac{wx^2}{2}

x and L use m; w uses kN/m; V uses kN; M uses kN·m. These lines apply before any point load.

Scope. A point load adds a shear jump. A concentrated couple adds a moment jump. Check load points, supports and overhang roots too.

Check and takeaway. A UDL gives a sloping shear line and a curved moment line. A flat moment diagram therefore cannot represent a loaded UDL region.

Apply the reasoning to this section’s data and conditions

  1. Mark slab arrows, support points and member spans.
  2. Find dead/imposed surface and line loads separately.
  3. Transfer each supported beam’s reaction exactly once.
  4. Find ULS actions and classify each exact section.
  5. Check shear/low-shear bending and then imposed-only deflection.
  6. End with an explicit pass/fail statement and answer the short theory part.

Prediction with explained answer

Use the same mechanism: A safe beam can still sag too far. For the same UDL and stiffness, doubling span multiplies deflection by sixteen. Doubling I halves deflection.

Apply the reasoning to this section’s data and conditions

Prediction and explained answer.

Invented variant: increase only the imposed surface load 20%.

What happens to the two deflection checks?

Answer and reasoning

Multiply only the imposed-load deflection by 1.2: B1 becomes 11.246500mm, and B2 becomes 2.358277mm.

Compare respectively with 19.444444 and 13.888889mm.

Both remain below their limits.

Recalculate strength actions using 1.4G+1.6×1.2Q.

Dead load is unchanged, so do not multiply everything directly by 1.2.