Connection example 8: flange welds carry moment, web welds carry shear
← Read this lecture example beside its chapter concepts
Design the bracket welds for dead plus imposed load at from the support. The bracket is cut from a UB. The specified web-weld leg is half the flange-weld leg. Use S355 and Class 42 electrode.
Original source: LectureNotes/Ch 2_Connection.pdf — p. 41.
A given value comes from the question or diagram.
A lookup value comes from the named table.
A calculated value follows from the working.
Each assumption is stated where the calculation needs it.
Known information, diagram labels and unknowns
A force couple carries moment
Separate the force couple used to carry moment from the force used to carry web shear.
Prediction, then explanation. For the same moment, a larger lever arm requires a smaller couple force. It does not remove the web shear.
Moment is force multiplied by perpendicular separation. Divide the required moment by the specified separation to obtain each couple force.
M is moment in kN·mm; z is the specified force-line separation in mm; F is force in kN.
Scope. Use the lever arm defined by the source model. Do not silently replace it with overall section depth or another geometric distance.
Check and takeaway. Check flange welds for the couple forces and web welds for the stated shear model. Both force paths need a satisfactory detail.
The weld resists through its throat
Convert a visible fillet leg into resistance per effective length.
Prediction, then explanation. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.
For the course right-angle equal-leg fillet, take throat as 0.7 times leg. Multiply throat area per unit length by weld strength.
s and a are leg and throat in mm. pw is weld strength in N/mm². qcap is resistance in kN/mm.
Scope. Use effective length, the correct steel/electrode strength and permitted leg limits. Full-penetration butt welds use a different model.
Check and takeaway. Illustration: a 6 mm leg at 250 N/mm² gives .
A table value has conditions
Find a design property without mixing a row, column or standard from a different case.
Prediction, then explanation. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.
Match the complete section designation. Read the relevant axis and unit. For strength tables, select material, thickness and curve before interpolating.
Given values come from the question. Lookup values come from a named table. Assumed values require an explicit condition.
Scope. A missing row or omitted restraint cannot be recovered from a schematic’s scale. Keep the result conditional when required data are absent.
Check and takeaway. Record the table, row, column and unit beside the substitution. That makes a later check possible.
Apply the reasoning to this section’s data and conditions
| Input | Origin |
|---|---|
| Given load | dead, imposed; downward arrow at from connection face. |
| Given weld geometry | across flange run; vertical arm; web run; all explicitly dimensioned. |
| Given size relationship | 。 |
| Lookup/model | . Rotate about at bottom flange; flange weld takes moment, two web welds take direct shear. This is the source’s simplified force allocation. |
Why this method applies
Add force components at each bolt
An in-plane load acts away from the bolt-group centre. Find the largest resultant bolt force.
Prediction, then explanation. At fixed force, increasing eccentricity increases the moment component. Its direction differs between bolts.
Locate the bolt-group centre and coordinates. Add horizontal components together and vertical components together before finding each resultant.
e, xi and yi use mm; J uses mm². With M in kN·mm, each moment-force component is in kN.
Scope. These expressions use the stated elastic, equal-bolt in-plane model. Out-of-plane tension and prying require another model.
Check and takeaway. Do not add force magnitudes before resolving directions. Two perpendicular forces of 3 and 4 kN give 5 kN, not 7 kN.
Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.
Apply the reasoning to this section’s data and conditions
Do not treat this as a rectangular in-plane torsion weld.
The vertical load outside the supporting face produces flange tension and compression.
Moment equilibrium gives tensile flange force .
Divide that force by the effective flange weld length to get demand per millimetre.
Because effective length depends on chosen leg, select a trial leg and verify it self-consistently.
1. Design force and force couple
Use the same mechanism: A force couple carries moment. For the same moment, a larger lever arm requires a smaller couple force. It does not remove the web shear.
Apply the reasoning to this section’s data and conditions
Mechanism detailsSeparate the moment couple and shear
The complete mechanism is explained below.
Read each stage together with its stated conditions; playback and interaction are not required.
- A simplified moment connection assigns different actions to different fastener groups.
- Opposite flange forces separated by z resist moment: .
- The web fasteners or welds carry the assigned vertical shear in this model.
- Flange force, web shear, plate bearing and detailing each need their specified checks.
2. Trial flange fillets
Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.
Use the same mechanism: A force couple carries moment. For the same moment, a larger lever arm requires a smaller couple force. It does not remove the web shear.
Apply the reasoning to this section’s data and conditions
Physical interpretation: How two flange forces make a moment
Two opposite forces form a turning pair, like two hands turning a wheel.
Sketch, not to scale; use the original dimensions.
- Identify the separation between their actual force lines.
- Required force equals moment divided by that separation.
- Design the relevant flange group for that force.
Remember: The force-line separation is not automatically the overall section depth.
The source tries .
The available run loses at its ends, leaving effective.
Use the printed weld run , not the nominal section width.
This also solves the implicit inequality by a verified trial.
Increasing improves throat but shortens effective length, so do not omit the recheck.
Mechanism detailsFrom fillet leg to effective throat
The complete mechanism is explained below.
Read each stage together with its stated conditions; playback and interaction are not required.
- An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
For this geometry, throat .
It is shorter than the leg.
Effective resisting area = .
With here, capacity per length is .
- Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.
3. Apply the required half-size rule and check shear
Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.
Use the same mechanism: A force couple carries moment. For the same moment, a larger lever arm requires a smaller couple force. It does not remove the web shear.
Apply the reasoning to this section’s data and conditions
Physical interpretation: Why the weld throat is smaller than its leg
The shortest cut through the weld is thinner than the outside leg.
Sketch, not to scale; use the original dimensions.
- For the stated equal-leg 90° fillet, throat is approximately 0.7 × leg.
- Multiply throat area by the matching weld design strength.
- For force per length, use a one-millimetre weld strip.
Remember: Choose strength from both the steel grade and electrode class.
Even though strength alone needs only about , use to satisfy the given relationship to the flange weld.
Mechanism detailsFrom fillet leg to effective throat
The complete mechanism is explained below.
Read each stage together with its stated conditions; playback and interaction are not required.
- An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
For this geometry, throat .
It is shorter than the leg.
Effective resisting area = .
With here, capacity per length is .
- Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.
4. Check lengths and identify the remaining thickness condition
Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.
Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.
Apply the reasoning to this section’s data and conditions
Physical interpretation: Drawn length and useful length differ
The start and end of a weld are not credited as fully effective in this course model.
Sketch, not to scale; use the original dimensions.
- Find the effective length required by strength.
- Add the specified end allowance to each separate run.
- Round up, then check minimum size, spacing and returns.
Remember: Strength alone does not prove a weld detail is acceptable.
The source dimensions describe weld runs on the cut bracket, not a licence to infer other fabrication details from scale.
The supporting column thickness is not stated.
The result therefore establishes flange/web weld strength and the size ratio; applicability of the thicker-part minimum-size rule to the support must be confirmed separately.
Mechanism detailsFrom fillet leg to effective throat
The complete mechanism is explained below.
Read each stage together with its stated conditions; playback and interaction are not required.
- An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
For this geometry, throat .
It is shorter than the leg.
Effective resisting area = .
With here, capacity per length is .
- Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.
Result and concise exam wording
Use the same mechanism: A force couple carries moment. For the same moment, a larger lever arm requires a smaller couple force. It does not remove the web shear.
Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.
Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.
Apply the reasoning to this section’s data and conditions
,.
About , flange force. flange weld has effective length and resistance. web welds each have effective length, combined resistance .
Both pass and web leg is half flange leg.
Support thickness for minimum weld-size verification is not supplied.
Misconceptions and checks
Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.
Apply the reasoning to this section’s data and conditions
The moment arm is .
The web run is .
They are not interchangeable.
Use two web welds.
However, the source’s tension-flange force is resisted by the specified flange run.
- Subtract using that run’s own leg size.
How the method transfers to a new variant
Use the same mechanism: A force couple carries moment. For the same moment, a larger lever arm requires a smaller couple force. It does not remove the web shear.
Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.
Apply the reasoning to this section’s data and conditions
- Identify the source pivot and the flange-force arm.
- Factor load and calculate moment/force couple.
- Try a flange leg, calculate its effective length and verify capacity.
- Apply the specified web/flange size relationship and check web shear.
- Check effective-length/detailing rules and state unprovided support data.
Prediction with explained answer
Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.
Apply the reasoning to this section’s data and conditions
Prediction and explained answer.
Keep the selected welds and increase the eccentricity to .
What happens to the flange strength check?
Answer and reasoning
Flange force becomes , greater than .
The flange weld fails while the unchanged direct web shear remains and still passes.
Mechanism detailsSeparate the moment couple and shear
The complete mechanism is explained below.
Read each stage together with its stated conditions; playback and interaction are not required.
- A simplified moment connection assigns different actions to different fastener groups.
- Opposite flange forces separated by z resist moment: .
- The web fasteners or welds carry the assigned vertical shear in this model.
- Flange force, web shear, plate bearing and detailing each need their specified checks.