2022–2024 · Exam-focused route
2023 FT/PTD BQ2(b) — welded UB bracket
Check the provided 6 mm and 8 mm welds under a separated shear-and-couple model.
Marks are as printed in the paper; the working is a teaching guide, not an official marking scheme.
Separate the web force and flange couple
A force couple carries moment
Separate the force couple used to carry moment from the force used to carry web shear.
Prediction, then explanation. For the same moment, a larger lever arm requires a smaller couple force. It does not remove the web shear.
Moment is force multiplied by perpendicular separation. Divide the required moment by the specified separation to obtain each couple force.
M is moment in kN·mm; z is the specified force-line separation in mm; F is force in kN.
Scope. Use the lever arm defined by the source model. Do not silently replace it with overall section depth or another geometric distance.
Check and takeaway. Check flange welds for the couple forces and web welds for the stated shear model. Both force paths need a satisfactory detail.
Apply the reasoning to this section’s data and conditions
Given design force 600 kN at 125 mm from the support face; S355 bracket cut from 457 × 191 × 67 UB.
Class 35 electrodes; two 6 mm web fillets of physical length 350 mm, and 8 mm flange fillets with physical length 160 mm.
The 350 mm dimension measures the web weld run.
Obtain the flange-force lever arm from the flange geometry.
Use the question’s separated model: web welds carry shear, flange welds carry the moment couple.
Physical interpretation and limits
The web connection carries downward shear.
The top and bottom flange welds form an opposing force pair that resists tipping.
A door hinge provides a limited analogy: both arrangements resist translation and rotation.
The analogy does not determine weld forces or resistance.
A longer vertical separation needs less force in each member of the pair.
BQ2(b) — check the web and flange welds [13 marks]
Use the same mechanism: A force couple carries moment. For the same moment, a larger lever arm requires a smaller couple force. It does not remove the web shear.
The weld resists through its throat
Convert a visible fillet leg into resistance per effective length.
Prediction, then explanation. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.
For the course right-angle equal-leg fillet, take throat as 0.7 times leg. Multiply throat area per unit length by weld strength.
s and a are leg and throat in mm. pw is weld strength in N/mm². qcap is resistance in kN/mm.
Scope. Use effective length, the correct steel/electrode strength and permitted leg limits. Full-penetration butt welds use a different model.
Check and takeaway. Illustration: a 6 mm leg at 250 N/mm² gives .
A table value has conditions
Find a design property without mixing a row, column or standard from a different case.
Prediction, then explanation. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.
Match the complete section designation. Read the relevant axis and unit. For strength tables, select material, thickness and curve before interpolating.
Given values come from the question. Lookup values come from a named table. Assumed values require an explicit condition.
Scope. A missing row or omitted restraint cannot be recovered from a schematic’s scale. Keep the result conditional when required data are absent.
Check and takeaway. Record the table, row, column and unit beside the substitution. That makes a later check possible.
Apply the reasoning to this section’s data and conditions
Class 35 with S355 gives pw = 220 N/mm².
It is not the Class 42 value used in the other paper.
For each straight physical run, the course effective length deducts twice the leg size.
The web weld has two separate runs; count both after deducting each run’s ends.
Look up the exact UB dimensions: overall depth 453.4 mm, flange thickness 12.7 mm and web thickness 8.5 mm.
Adopt the flange-centroid force-couple separation below.
The drawing places the flange welds at the outer flanges; using the smaller flange-centroid separation is conservative for their force.
The weld-centroid distance itself is not dimensioned, so make this model explicit.
The force couple already consists of a top force and an equal opposite bottom force.
Each flange weld resists one force.
Do not divide its force by two again.
The course edge-size observation gives 6 ≤ 8.5−2 = 6.5 mm at the web and 8 ≤ 12.7−2 = 10.7 mm at the flange.
These and the effective lengths pass.
The support thickness is absent.
Therefore, the minimum size governed by the thicker connected part and the supporting member’s resistance remain unverified.
Result and concise exam wording
Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.
Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.
Apply the reasoning to this section’s data and conditions
Concise exam wording
With pw=220 N/mm² and z=440.7 mm, both weld strength checks pass.
State the couple model and the missing support-thickness condition.
Misconceptions and checks
Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.
Apply the reasoning to this section’s data and conditions
- Class 35 and Class 42 are different electrode rows.
- The labelled 350 mm is a weld-run length, not a moment arm.
- Do not use physical weld lengths as effective lengths.
Procedure for a new variant
Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.
Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.
Apply the reasoning to this section’s data and conditions
- Assign shear to web welds and moment to the flange couple.
- Look up electrode strength and exact section dimensions.
- Deduct weld end lengths, compare each force with its own weld capacity.
Prediction with explained answer — invented variant
Treat a weld group as lines
An eccentric force creates direct line force and torsional line force in the same weld group.
Prediction, then explanation. Increasing eccentricity increases the torsional contribution. The governing corner depends on vector addition, not distance alone.
Find the line centroid. Integrate squared distance along the effective lines. Add direct and torsional components at every candidate critical point.
J is line polar inertia in mm³. x and y use mm. With M in kN·mm, q is line force in kN/mm.
Scope. A solid rectangle has area inertia in mm⁴ and is not this weld-line model. Missing weld sides change the centroid and integrals.
Check and takeaway. Compare the largest resultant line force with the selected throat resistance. Keep kN/mm distinct from total force in kN.
Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.
Apply the reasoning to this section’s data and conditions
Invented variant: eccentricity increases to 150 mm.
Do the same welds pass?
Hint
Only the moment demand changes.
Answer and reasoning
Flange welds fail.
The web shear check is unchanged and still passes.