STEELWORK / CON4334
Reference

Exam error checklist and source discrepancies

Diagrams, explanations and answers are presented in reading order. No playback or response is required.
All answers shownChinese–English terminology

Use the first list before handing in an answer.

The second records actual differences in the supplied sources.

An independently derived correction is not an official marking scheme.

The last six minutes of an exam

Change the ruler, keep the quantity

A section table uses centimetres, but the strength calculation uses millimetres. The numbers must describe the same section.

Length1 factorArea2 factors3 factorsEach centimetre becomes ten millimetres.
In the diagram, the length, square and cube contain one, two and three length factors. Each factor changes when the ruler changes.

Prediction, then explanation. Would every property increase by ten? No. The exponent determines how many factors of ten are needed.

First identify the physical quantity. Next convert each length factor. Keep force and length conversions separate when converting a moment.

1 cmn=10n mmn,1 kN m=106 N mm1\,\mathrm{cm}^n=10^n\,\mathrm{mm}^n,\qquad 1\,\mathrm{kN\,m}=10^6\,\mathrm{N\,mm}

Here n is the length exponent: 2 for area, 3 for section modulus and 4 for second moment of area.

Scope. Changing units changes neither the load nor the section. A conversion factor cannot repair a formula for the wrong physical quantity.

Check and takeaway. Illustration: 2 cm4=20,000 mm42\,\mathrm{cm}^4=20{,}000\,\mathrm{mm}^4. The fourth power belongs to the unit, not the number 2.

A table value has conditions

Find a design property without mixing a row, column or standard from a different case.

The row and column meet at one cell. The table heading supplies the units and the conditions that give the cell meaning.
The row and column meet at one cell. The table heading supplies the units and the conditions that give the cell meaning.

Prediction, then explanation. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Match the complete section designation. Read the relevant axis and unit. For strength tables, select material, thickness and curve before interpolating.

Given values come from the question. Lookup values come from a named table. Assumed values require an explicit condition.

Scope. A missing row or omitted restraint cannot be recovered from a schematic’s scale. Keep the result conditional when required data are absent.

Check and takeaway. Record the table, row, column and unit beside the substitution. That makes a later check possible.

Apply the reasoning to this section’s data and conditions

  1. Have I answered the compulsory question and exactly the required number of options, including every labelled subpart?
  2. Does each load carry its source and status: characteristic, already factored, calculated reaction or lookup self-weight?
  3. Do reactions balance total load and moment?

    Does the BMD close to zero at a simple support with no applied end couple?

  4. Have I used the exact section row, correct axis, thickness-dependent py and cm-to-mm conversion?
  5. Have I separated low/high shear, section capacity, LTB, local web behaviour and deflection?
  6. For bolts, did I count shear planes and transfer sides correctly?

    For welds, did I use effective length and the correct centroid?

  7. For columns, did I use the correct curve per axis, correct moment sign, amplified versus first-order moment and correct denominator?
  8. Do dimensions come from labels or justified calculations, rather than scale measurements?
  9. Have I compared demand and resistance with units, stated pass/fail and named conditions that remain unverified?

Mechanism detailsFollow the calculation sequence3 concepts

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Locate the load, supports, connection geometry and any stated assumptions.
  2. Keep given values, table lookups and calculated values distinct; reconcile their units.
  3. The calculation player steps through the existing expressions in their original order.
  4. Compare demand with resistance or the relevant limit.

    Keep missing inputs and conditional conclusions explicit.

Source discrepancies and how this site handles them

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Use the same mechanism: Change the ruler, keep the quantity. Would every property increase by ten? No. The exponent determines how many factors of ten are needed.

Apply the reasoning to this section’s data and conditions

Original source / locationIssueTreatment and evidence
Syllabus p 4 versus Ch 1 p 7 and Data File footersSyllabus cites 2011 (2023 Edition); supplied teaching/data identify 2011.Use the supplied course equations and tables consistently; standards note.
Data File p 2, central point-load deflectionPrints PL448EI, which has units mm2 rather than displacement.Use PL348EI, supported by Word note p 2 and 2023 Data 1; original correct equation.
Data File p 8, curve b / py 355 / λ90Cell prints 18.Use 181Nmm2, clearly shown in Ch 4 p 8, same row and column.
Data File p 3, compressed column equationsBars and elastic moment denominators are not fully represented.Use full lecture Eqs.8.80/8.81 and keep amplified/first-order moments distinct; full method.
Data File p 12, 125×75 angle blockSome thickness labels are inconsistent with the area/property sequence.

2024 angle question uses the stated 125/75/8 rectangular leg method; explicit derivation.

Do not invent a corrected table row.

Ch 2 Example 1 pp 16–17Drawing shows four centre crosses; text and solution specify two bolts.Follow the explicit two-bolt model and disclose the mismatch; worked solution.
Ch 2 Example 9 p 42Side Y text says add 12 but its arithmetic adds 8 for a 4mm fillet.Correct deduction 2s=8mm; final physical lengths 200/100mm remain; derivation.
Ch 2 Example 10 pp 43–44 versus minimum-size table p 33Selected 6mm fillet joins a 20mm main plate; supplied minimum table requires 8mm.Preserve lecture trial, then design an 8mm alternative with 145mm runs and 20mm returns; checked dimensions.
Chapter 2 Tutorial 5, pp.45/476mm angle and 12mm gusset give maximum edge leg 4 but minimum leg 5.No size satisfies both supplied rules; show the conflict and required redesign, not a fictitious passing detail; solution.
Ch 3 Example 4 p 31Names a 452×152×52 UB.Listed properties match supplied 457×152×52 row; solution uses that row.
Ch 4 Example 3 pp 29–30Amplified moment appears as 56.4 after a 56.9 calculation.Use consistent unrounded moment 56.8388267kN·m from exact loads, or 56.925 if retaining lecturer rounded 49.5; derivation.
Ch 4 Example 5 p 38Rounded interaction terms sum to printed 0.94.Unrounded sum is about 0.9496, rounding to 0.95; pass unchanged; calculation.
Assignment 2 heading and Q1Filename/header/figure identifiers conflict; key text sentence is clipped from rendered paragraph.Use the supplied text-layer section/length data explicitly; original figures retained; source note.
2024 paper, six supplied pagesMentions an 18-page data attachment that is not included.Use identified standalone/2023 supplied lookups; missing attachment is not fabricated; paper navigator.
Small rounding differences in lecture tables/examplesSome cells truncate or use rounded intermediate capacities.Recalculate from printed input areas, keep guard digits and distinguish rounding from changed assumptions; every table cell.

Mechanism detailsFollow the calculation sequence3 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Locate the load, supports, connection geometry and any stated assumptions.
  2. Keep given values, table lookups and calculated values distinct; reconcile their units.
  3. The calculation player steps through the existing expressions in their original order.
  4. Compare demand with resistance or the relevant limit.

    Keep missing inputs and conditional conclusions explicit.

Conditions that cannot be verified from a sketch alone

A concentrated force spreads into the web

Check local web resistance at a support or concentrated load, even if overall beam strength passes.

Compare Narrow contact with Wide contact. Both receive the same force, but the wider contact distributes it over a longer region.
Compare Narrow contact with Wide contact. Both receive the same force, but the wider contact distributes it over a longer region.

Prediction, then explanation. A longer valid stiff-bearing length can spread the same force over more web. A flexible contact is not automatically stiff bearing.

Match the actual bearing geometry to its source sketch. Use that sketch’s dimensions and permitted spread to calculate the resisting region.

b₁ is stiff-bearing length in mm. Web thickness and applicable design strength enter the prescribed local resistance equation.

Scope. End and interior cases can differ. A lateral-restraint symbol does not provide a bearing length or a load-introduction detail.

Check and takeaway. If bearing geometry is missing, give the applicable symbolic check and state the missing input. Do not borrow another example’s dimensions.

An eccentric bracket pulls bolts differently

An out-of-plane moment rotates the bracket about the stated pivot. Determine the bolt tension pattern.

The pivot is the compression reference. Bolts farther from it have longer lever arms in the course elastic model.
The pivot is the compression reference. Bolts farther from it have longer lever arms in the course elastic model.

Prediction, then explanation. For unchanged geometry, doubling the applied moment doubles the modelled bolt tensions. Changing the pivot changes the distribution.

Use compatibility to relate tension to distance. Moment equilibrium then determines the proportionality factor.

Ft,i=Myi∑yj2F_{t,i}=\frac{My_i}{\sum y_j^2}

M is moment in kN·mm. yi is distance from the stated pivot in mm. Ft,i is tension in kN.

Scope. Apply only to the stated active bolt set and pivot model. Flexible plates can create prying; use the supplied assumptions and resistance definitions.

Check and takeaway. A bolt’s lever arm is measured from the pivot used in the equation. It is not automatically its distance from the group centroid.

A bolt diameter is not a hole diameter

Check that bolts fit and leave enough material between holes and plate boundaries.

pdd₀Clear ligament
The inner circle represents bolt diameter d. The outer circle represents hole diameter d₀. Pitch and gauge join hole centres.

Prediction, then explanation. At fixed pitch, a larger hole leaves a shorter clear ligament. Increasing bolt diameter may also increase minimum edge-distance requirements.

Measure pitch along the bolt line and gauge across lines. Distinguish end distance along the load from edge distance across it.

lc=p−d0l_c=p-d_0

lc is clear ligament between holes; p is centre-to-centre pitch; d₀ is hole diameter. All use mm.

Scope. Apply the supplied edge-preparation and minimum/maximum spacing rules. Passing a bearing calculation does not prove the layout passes.

Check and takeaway. For pitch 60 mm and hole diameter 22 mm, the ligament is 38 mm. Using a 20 mm bolt diameter here gives the wrong ligament.

Apply the reasoning to this section’s data and conditions

The coverage checklist records affected items as incomplete when a requested final detail needs absent input.

Examples include local bearing/contact lengths, missing plate thickness for a weld-size limit, unknown transverse bolt gauge for no-prying applicability, and an unstated LTB load-height/end-restraint model.

A conditional calculation is still useful teaching, but it is not an unconditional certification.

Read the item-by-item blockers.

All original files remain unchanged.

The website’s illustration for the AI-sketch assignment is authored teaching material.

It is not a fabricated student conversation screenshot.

Mechanism detailsFollow the calculation sequence7 concepts

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Locate the load, supports, connection geometry and any stated assumptions.
  2. Keep given values, table lookups and calculated values distinct; reconcile their units.
  3. The calculation player steps through the existing expressions in their original order.
  4. Compare demand with resistance or the relevant limit.

    Keep missing inputs and conditional conclusions explicit.

A better error log

Make the next decision from the known conditions

Read the specific task below and identify the quantity or explanation it asks for.

ConditionsModelCalculationCheckA changed condition can change the method.
The sequence links source conditions, a physical model, a calculation and a checked conclusion. Each link needs the previous one.

Prediction, then explanation. Changing a load value may preserve the method. Changing the support or failure mechanism can require a different method.

Separate given, lookup, calculated and assumed values. State why the model applies. Keep necessary intermediate steps and units beside the equations.

A conditional answer states the exact condition required for its conclusion. It does not fill missing data with a guess.

Scope. A repeated result is not an independent verification. Use equilibrium, dimensions, a reverse substitution or an appropriate limiting case.

Check and takeaway. The explanation and answer are shown together in this edition. No response, score or completed interaction is needed to continue.

Apply the reasoning to this section’s data and conditions

RecordExample
First incorrect decisionI used the full 10m dimension rather than the 5m support-to-support B2 span.
Evidence I missedA column symbol occurs on the middle grid line.
RepairDraw only one free-body span; label each support before transferring loads.
Independent retestSolve the 2024 floor variant with altered slab load and no open solution.

Prediction and explained answer.

Why is “I made an arithmetic mistake” too vague after a wrong LTB result?

Answer and reasoning

The first error may be choosing full span instead of restraint spacing, using the wrong ry unit, or reading λ rather than λLT.

Identify the first wrong decision so the next unfamiliar problem is solved correctly.

Mechanism detailsFollow the calculation sequence1 concept

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Locate the load, supports, connection geometry and any stated assumptions.
  2. Keep given values, table lookups and calculated values distinct; reconcile their units.
  3. The calculation player steps through the existing expressions in their original order.
  4. Compare demand with resistance or the relevant limit.

    Keep missing inputs and conditional conclusions explicit.