STEELWORK / CON4334
Worked examples

Column example 3: loads and eccentric moments in two storeys

Diagrams, explanations and answers are presented in reading order. No playback or response is required.

← Read this lecture example beside its chapter concepts

All answers shownChinese–English terminology
Diagrams, explanations and answers are presented in reading order. No playback or response is required.

Check 203×203×60 UC S355 in a two-storey simple-construction column. The lower storey is 3m, the upper 6m. Use the supplied reaction table and stated construction assumptions, including a pinned base and 1.15 moment amplification.

Original source: LectureNotes/Ch 4_Column.pdf — p. 25, p. 26, p. 27, p. 28, p. 29, p. 30, p. 31.

A given value comes from the question or diagram.

A lookup value comes from the named table.

A calculated value follows from the working.

Each assumption is stated where the calculation needs it.

Known information, diagram labels and unknowns

An eccentric beam reaction bends the column

A simple beam joint delivers a vertical reaction away from the column centre. Find the resulting column moments.

The reaction arrow is offset by e from the column centre. The upper and lower arrows show where the joint moment is shared.
The reaction arrow is offset by e from the column centre. The upper and lower arrows show where the joint moment is shared.

Prediction, then explanation. Equal opposite-face reactions can cancel a joint moment. Their downward forces still add to column compression.

Sum axial forces first. Calculate the signed eccentric moments. Share the net joint moment between upper and lower columns using the stated stiffness model.

M=Re,Mlower=MKlowerKupper+KlowerM=Re,\qquad M_{lower}=M\frac{K_{lower}}{K_{upper}+K_{lower}}

R is reaction; e is perpendicular eccentricity. K denotes the stiffness measure prescribed for moment sharing.

Scope. Equal sharing requires equal stated stiffness. Use actual storey length where the special simple-construction LTB rule requires it.

Check and takeaway. A pin-like beam connection can still cause an eccentric reaction moment in the column. Joint rotation and reaction location are separate facts.

Moment shape matters within one segment

Represent a nonuniform moment distribution in the applicable member-buckling equation.

The two diagrams have equal peaks. The left high-moment region is short; the right high-moment region extends across more of the segment.
The two diagrams have equal peaks. The left high-moment region is short; the right high-moment region extends across more of the segment.

Prediction, then explanation. Two segments can have equal peak moment but different distributions. Their equivalent moment factors can therefore differ.

Evaluate moments from the true whole-beam analysis at the required positions. Apply the exact table’s weights, signs and lower bound.

mLT is an LTB factor. mx and my belong to the specified flexural checks. They are not interchangeable.

Scope. Some rules use magnitudes; others require signed ordinates. A factor does not reduce the actual moment used in a local section check.

Check and takeaway. Measure quarter points from the segment start, not automatically from the beam’s left support.

A table value has conditions

Find a design property without mixing a row, column or standard from a different case.

The row and column meet at one cell. The table heading supplies the units and the conditions that give the cell meaning.
The row and column meet at one cell. The table heading supplies the units and the conditions that give the cell meaning.

Prediction, then explanation. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Match the complete section designation. Read the relevant axis and unit. For strength tables, select material, thickness and curve before interpolating.

Given values come from the question. Lookup values come from a named table. Assumed values require an explicit condition.

Scope. A missing row or omitted restraint cannot be recovered from a schematic’s scale. Keep the result conditional when required data are absent.

Check and takeaway. Record the table, row, column and unit beside the substitution. That makes a later check possible.

Apply the reasoning to this section’s data and conditions

Given modelImplication
Continuous column, simple beam constructionUse nominal eccentricity and IL moment sharing; all moment factors are 1.
Base effectively pinned

Lower segment has no base rotational fixity.

Substantial level 2 members give the source’s upper restraint assumption.

Roof secondary beams are small tiesProvide positional but not rotational restraint for the upper column’s weak-axis buckling.
Main beams connect by web and seating cleatsSource adopts reaction line 100mm beyond the column face.
Self-weightSource assumes 20kN characteristic dead self-weight at each level; include it once per level.
Section dataData p.11: D=209.6, t=9.4, T=14.2, d=160.8mm, bT=7.25, dt=17.1, rx=8.96cm, ry=5.20cm, A=76.4cm2, Sx=656, Sy=305, Zx=584, Zy=201cm3.

Why this method applies

Use the same mechanism: An eccentric beam reaction bends the column. Equal opposite-face reactions can cancel a joint moment. Their downward forces still add to column compression.

A force couple carries moment

Separate the force couple used to carry moment from the force used to carry web shear.

The flange forces act in opposite directions. Their separation z gives the lever arm. The web arrow represents shear.
The flange forces act in opposite directions. Their separation z gives the lever arm. The web arrow represents shear.

Prediction, then explanation. For the same moment, a larger lever arm requires a smaller couple force. It does not remove the web shear.

Moment is force multiplied by perpendicular separation. Divide the required moment by the specified separation to obtain each couple force.

F=M/zF=M/z

M is moment in kN·mm; z is the specified force-line separation in mm; F is force in kN.

Scope. Use the lever arm defined by the source model. Do not silently replace it with overall section depth or another geometric distance.

Check and takeaway. Check flange welds for the couple forces and web welds for the stated shear model. Both force paths need a satisfactory detail.

Balance the isolated beam

Find the two vertical reactions before calculating internal shear or moment.

A / RₐB / RᵦPaL
A and B are vertical supports. The downward load acts at distance a from A. Its distance from B is L − a.

Prediction, then explanation. Move the same load toward B. Reaction B increases because the load has a larger moment arm about A.

Take moments about A. Reaction A has zero lever arm there. Then use vertical force balance to find reaction A.

RBL=Pa,RA+RB=PR_B L=Pa,\qquad R_A+R_B=P

P, RA and RB are forces in kN. L is support spacing and a is load position, both in m.

Scope. These expressions describe one point load on a simply supported beam. Add other loads through equilibrium; keep their actual positions.

Check and takeaway. Illustration: P = 60 kN, L = 6 m and a = 2 m give RB = 20 kN and RA = 40 kN.

Apply the reasoning to this section’s data and conditions

There are two separate accounting tasks.

Axial load accumulates down the column.

Eccentric reactions create a net joint moment which is shared between the upper and lower column in proportion to IL.

Equal opposite secondary reactions cancel their moments, but their vertical loads still add.

Keep these operations separate.

This solution retains arithmetic precision.

A short comparison also explains the source’s rounded values.

1. Recalculate every reaction-table entry and storey total

Keep load categories separate

A floor carries permanent material and changing occupancy loads. Find the design load for the stated check.

The two boxes show G and Q with their separate factors. The plus sign joins their factored values.
The two boxes show G and Q with their separate factors. The plus sign joins their factored values.

Prediction, then explanation. Increasing imposed load changes its own term. It does not change the dead-load factor or the steel stiffness.

First convert mass to weight where required. Next collect G and Q in compatible units. Apply the combination specified by the course problem.

Wu=1.4G+1.6QW_u=1.4G+1.6Q

G is characteristic dead load; Q is characteristic imposed load. Wu is the design load for this course gravity combination.

Scope. This combination is not universal. Use the specified service load for deflection and the stated factors for other standards or cases.

Check and takeaway. Illustration: G = 10 kN and Q = 5 kN give 22 kN. Factoring their sum by one guessed factor loses the distinction.

Follow one strip of floor

An area load must become a beam load before beam reactions can be calculated.

The highlighted tributary strip supplies one beam. The right-hand labels show area load multiplied by width becoming line load.
The highlighted tributary strip supplies one beam. The right-hand labels show area load multiplied by width becoming line load.

Prediction, then explanation. At fixed area load, twice the tributary width gives twice the line load. An end reaction remains a concentrated force.

Consider one metre along the beam. The associated floor area is b square metres. Multiply area load by that width.

w=qbw=qb

q is area load in kN/m²; b is tributary width in m; w is line load in kN/m.

Scope. Determine b from slab spanning and supports. Add beam self-weight separately. A secondary-beam reaction is not automatically a UDL.

Check and takeaway. Illustration: 3 kN/m2×2 m=6 kN/m3\,\mathrm{kN/m^2}\times2\,\mathrm{m}=6\,\mathrm{kN/m}. The width cancels one length unit.

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

Level/reactionGiven G (kN)1.4GGiven Q (kN)1.6QUltimate total
3: R132028203260
3: R332028203260
3: R232433.680128161.6
3: assumed self-weight20280028
3 totals84117.6120192309.6
2: R123042100160202
2: R323042100160202
2: R223042200320362
2: assumed self-weight20280028
2 added totals110154400640794
Upper column segment 2–3: Fc=309.6kN. Lower column segment 1–2: Fc=309.6+794=1,103.6kN. Check using accumulated components: G=84+110=194kN;Q=120+400=520kN1.4×194+1.6×520=271.6+832=1,103.6kN

Mechanism detailsFrom characteristic to design load3 concepts · 2 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. G is permanent load; Q is imposed load.

    A surface load and a line load also have different units.

  2. This illustration uses the course gravity case .

    Other combinations in the original text retain their own factors.

  3. For illustrative , the separate load contributions show what changes when Q increases.
  4. Do not carry this ULS total automatically into deflection.

    Follow the stated SLS load case.

2. Strength and section classification

Find which plate buckles first

Before using plastic bending resistance, check whether the flange and web can sustain the required stress distribution.

The short waves are local plate buckling. They differ from sideways movement of the whole member.
The short waves are local plate buckling. They differ from sideways movement of the whole member.

Prediction, then explanation. At fixed width, a thinner plate has a larger width-to-thickness ratio. Local buckling then becomes more restrictive.

Calculate the flange and web ratios separately. Compare each with the limits for its stress condition. The worse class governs.

ε=275/py\varepsilon=\sqrt{275/p_y}

py is the design yield strength in N/mm². ε is a dimensionless scale used in the supplied classification limits.

Scope. Pure bending and uniform compression use different web limits. Class 2 allows plastic resistance but not the Class 1 rotation capability.

Check and takeaway. A Class 1 web and Class 2 flange give a Class 2 section. Do not average the class numbers.

Apply the reasoning to this section’s data and conditions

T=14.2≤16mm→py=355Nmm2ε=275355=0.880141Flange: bT=7.25<9ε=7.92127, Class 1. Lower-storey web: r1=1,103,600160.8×9.4×355≈2.057Use the cap r1=1. Class 1 web limit: 80ε1+r1=40ε=35.2056dt=17.1<35.2056; the web is Class 1. The upper storey has smaller axial force and also passes using this same conservative web limit.

The lower section’s larger axial compression is sufficient for checking this section’s worst compression/bending web limit.

The selected section has the same geometry throughout both storeys.

Mechanism detailsWhy thin elements buckle locally1 concept · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. The flange outstand and web have different widths, thicknesses and edge support conditions.
  2. A thinner plate can wrinkle locally before the complete member loses stability.
  3. Class 1 allows plastic rotation.

    Class 2 reaches plastic resistance.

    Class 3 reaches elastic resistance.

    Class 4 requires effective properties.

  4. Check every relevant compression element with the supplied limits and stress distribution.

    The deformation shown is qualitative.

3. Calculate section and elastic member capacities

Internal tension and compression resist moment

Find which section resistance applies before comparing it with the moment demand.

In sagging bending, the upper region compresses and the lower region stretches. Together their forces form a resisting couple.
In sagging bending, the upper region compresses and the lower region stretches. Together their forces form a resisting couple.

Prediction, then explanation. A larger appropriate section modulus raises resistance at fixed strength. Local plate buckling can restrict the usable modulus.

Classify the section first. At low shear, use the elastic expression for Class 3 or the prescribed capped plastic expression for Classes 1 and 2.

Mc=min⁡(pyS,1.2pyZ)for Class 1/2 at low shearM_c=\min(p_yS,1.2p_yZ)\quad\text{for Class 1/2 at low shear}

py uses N/mm². S is plastic modulus and Z is elastic modulus, both in mm³. Mc then uses N·mm.

Scope. This is section resistance, not whole-member LTB resistance. High shear and Class 4 require their appropriate treatment.

Check and takeaway. Selecting the larger of the two capped terms defeats the cap. Use their minimum.

A strong cross-section can belong to an unstable member

A column carries axial compression and bending. Explain why more than one check is required.

The three boxes name separate checks: Section, Flexural and LTB. The bottom caption explains that passing one does not pass the others.
The three boxes name separate checks: Section, Flexural and LTB. The bottom caption explains that passing one does not pass the others.

Prediction, then explanation. At fixed moments and resistances, increasing compression increases utilisation. A section pass cannot remove the length-dependent instability checks.

Separate cross-section, flexural-buckling and LTB interaction equations. Use each equation’s own denominators and first-order or amplified moments.

AgpyA_g p_y is a section axial resistance. AgpcA_g p_c is a member compression resistance. Elastic pyZp_y Z and prescribed McM_c are different bending denominators.

Scope. Preserve the course barred-moment definitions and Eq. 8.81 convention. Do not substitute plastic moduli into an elastic denominator.

Check and takeaway. Report each requested utilisation and the governing check. The largest properly calculated ratio identifies the closest limit.

Apply the reasoning to this section’s data and conditions

Ag=76.4×100=7,640mm2Agpy=7,640×3551,000=2,712.2kNMcx=min(355×6561,000,1.2×355×5841,000)=min(232.88,248.784)=232.88kN·mMcy=min(355×3051,000,1.2×355×2011,000)=min(108.275,85.626)=85.626kN·mElastic denominator for member checks: Mex=355×5841,000=207.32kN·mMey=355×2011,000=71.355kN·m

The linear section interaction uses 232.88 and 85.626.

The member interaction uses 207.32 and 71.355.

The source reuses similar Mc notation for different definitions.

Keep a clearly labelled capacity list.

Mechanism detailsCompression and tension across a section2 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. For sagging, the top flange is in compression and the bottom in tension; hogging reverses this.
  2. Elastic bending stress varies with distance from the neutral axis: .
  3. The section class governs whether elastic, plastic or effective properties may be used.
  4. Use the shear at the section under examination.

    The largest shear elsewhere is not automatically coexistent.

4. Nominal eccentricity and stiffness sharing at level 2

Use the same mechanism: An eccentric beam reaction bends the column. Equal opposite-face reactions can cancel a joint moment. Their downward forces still add to column compression.

Apply the reasoning to this section’s data and conditions

Physical interpretation: A pinned beam can still bend its column

Its reaction can miss the column centre and create a lever arm.

A pinned beam can still bend its column — Its reaction can miss the column centre and create a lever arm.

Sketch, not to scale; use the original dimensions.

  1. Find the reaction’s actual nominal eccentricity.
  2. Multiply reaction by eccentricity to obtain the joint moment.
  3. Share that moment using the stated column-stiffness model.

Remember: Equal sharing needs equal relevant stiffness.

It is not automatic.

Related concept and full method

The main beam reaction R22 acts on one flange.

D2 takes us from the centroid to the flange face.

The nominal 100mm then takes us to the source’s reaction line.

R12 and R32 have equal magnitudes on opposite sides, so their minor-axis nominal moments cancel.

ex=D2+100=209.62+100=204.8mm=0.2048mM2=R22×ex=362×0.2048=74.1376kN·mLower-storey stiffness proportion: I3I3+I6=23Upper-storey stiffness proportion: I6I3+I6=13M2→1,first=74.1376×23=49.4250667kN·mM2→3,first=74.1376×13=24.7125333kN·mCheck the sum: 49.4250667+24.7125333=74.1376kN·mSymmetric opposing secondary-beam reactions give My=0.

The lower storey is shorter, hence stiffer and receives the larger moment share.

The source rounds e to 205mm, M2 to 74.2 and shares to 49.5/24.7.

The little moment diagrams on p.28 show the moment components associated with this joint sharing; they are not additional applied point loads.

Mechanism detailsEccentric reactions and stiffness sharing1 concept · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. A beam reaction can act away from the column centre even at a nominally pinned beam connection.
  2. .

    Opposing reactions can cancel part of the signed moment, while both still add compression.

  3. The course simple model distributes the joint moment in proportion to of the columns above and below.
  4. Equal relevant stiffness gives half each.

    A roof joint with no upper column is a different case.

5. Lower-storey section interaction

Use the same mechanism: A strong cross-section can belong to an unstable member. At fixed moments and resistances, increasing compression increases utilisation. A section pass cannot remove the length-dependent instability checks.

Two simultaneous actions use one component

Check a component that carries shear and tension, or compression and bending, at the same time.

The bolt receives two labelled arrows: tension and shear. The caption requires both individual checks and the combined check.
The bolt receives two labelled arrows: tension and shear. The caption requires both individual checks and the combined check.

Prediction, then explanation. At fixed resistances, increasing one demand increases its utilisation. The permitted sum is not always one.

First apply the individual checks. Next use the exact combined equation and its definitions. Keep demands from the same load case.

FsPs+FtPnom≤1.4\frac{F_s}{P_s}+\frac{F_t}{P_{nom}}\le1.4

This is the course bolt interaction rule. Fs and Ft are bolt demands; Ps and Pnom are their specified resistance denominators.

Scope. The 1.4 limit and nominal tension denominator do not apply to column equations. Their limits and moment definitions are separate.

Check and takeaway. A sum above one can pass this bolt rule while still needing individual checks. A pass must name the actual equation used.

Compression acts on the displaced shape

A compressed member moves away from its initial load line. Explain why the bending moment can increase.

The dashed line labelled Original marks the initial position. The tilted member creates the extra horizontal lever arm shown below.
The dashed line labelled Original marks the initial position. The tilted member creates the extra horizontal lever arm shown below.

Prediction, then explanation. At fixed axial force, a larger offset creates a larger additional moment. This can further increase the displacement.

Force acting through an offset forms a moment. Second-order analysis includes that changed geometry in equilibrium.

Madditional=PΔorPδM_{additional}=P\Delta\quad\text{or}\quad P\delta

P is axial force. Δ and δ are the relevant perpendicular displacements. Consistent force and length units give moment units.

Scope. Use the amplification or analysis method stated for the frame. Do not amplify an already amplified moment a second time.

Check and takeaway. Zero offset removes this additional moment in the ideal sketch. Real design may still require imperfections and code checks.

Apply the reasoning to this section’s data and conditions

Physical interpretation: The column needs more than one pass

A slice can be strong while the whole member still buckles.

The column needs more than one pass — A slice can be strong while the whole member still buckles.

Sketch, not to scale; use the original dimensions.

  1. Check cross-section compression plus bending.
  2. Then check the separate member-buckling expressions.
  3. Keep each moment, factor and resistance in its specified expression.

Remember: The three checks do not share interchangeable denominators.

Related concept and full method

Mx,amp=1.15×49.4250667=56.838827kN·mMLT=Mx,amp;My=0Usection=1,103.62,712.2+56.838827232.88+0=0.650971<1Lower-storey section passes.

Using the rounded source loads and moments gives 1,1042,712.2+1.15×49.5232.88≈0.6515.

Both precision levels agree with the source result of approximately 0.65.

Mechanism detailsA strong slice can belong to an unstable member3 concepts · 2 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Combine axial compression and the two bending demands using the specified section resistances.
  2. The whole member adds effective-length and buckling-curve effects.
  3. This uses its own moment factor and bending resistance.

    It is not a copy of the section check.

  4. Elastic, plastic and buckling resistances are not interchangeable.

    Read the three original expressions and their first-order/amplified moments.

6. Lower-storey member buckling

Use the same mechanism: A strong cross-section can belong to an unstable member. At fixed moments and resistances, increasing compression increases utilisation. A section pass cannot remove the length-dependent instability checks.

Check buckling about both axes

Determine which buckling direction limits the compressed member.

Compare the outlines labelled Straight and Bowed. The dashed line beside Bowed marks its original straight reference.
Compare the outlines labelled Straight and Bowed. The dashed line beside Bowed marks its original straight reference.

Prediction, then explanation. At fixed radius, longer effective length raises slenderness. The supplied buckling curve generally gives lower compressive strength.

Calculate slenderness about each axis. Select each axis’s curve from section type and thickness. Then obtain and compare the two compressive resistances.

λx=LEx/rx,λy=LEy/ry,Pc=pcAg\lambda_x=L_{Ex}/r_x,\quad\lambda_y=L_{Ey}/r_y,\qquad P_c=p_cA_g

Effective lengths and radii use mm. pc is compressive strength in N/mm²; Ag is gross area in mm²; Pc is in N.

Scope. Do not select the governing axis using radius alone. Effective length and buckling curve can differ. A combined column also needs interaction checks.

Check and takeaway. A short-section yield resistance is not the same as long-member buckling resistance. Keep py and pc distinct.

Vertical bending can trigger sideways motion

A beam has enough local bending resistance. Check whether its compression flange can move sideways and twist.

The dashed straight line is the initial reference. The curved flange lines illustrate the labelled sideways movement and twist.
The dashed straight line is the initial reference. The curved flange lines illustrate the labelled sideways movement and twist.

Prediction, then explanation. Adding a valid lateral restraint shortens a stability segment. It need not change the beam’s vertical reaction or moment diagram.

Identify the compressed flange and effective restraints. Calculate the specified slenderness, read buckling strength and compare resistance with the segment demand.

λ=LE/ry,Mb=pbSx  (Class 1/2),mLTMmax≤Mb\lambda=L_E/r_y,\qquad M_b=p_bS_x\;\text{(Class 1/2)},\qquad m_{LT}M_{max}\le M_b

LE and ry use the same length unit. pb uses N/mm²; Sx uses mm³; Mb uses N·mm. mLT is dimensionless.

Scope. Use the specified section class, effective-length branch and loading condition. Load height alone does not prove a destabilizing case.

Check and takeaway. Removing a lateral restraint requires a new segment stability check. The old shorter-segment result cannot establish the longer segment’s adequacy.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Why a long column can fail before crushing

Push a long thin ruler from both ends: it may bow sideways first.

Why a long column can fail before crushing — Push a long thin ruler from both ends: it may bow sideways first.

Sketch, not to scale; use the original dimensions.

  1. Find effective length and radius of gyration for each axis.
  2. Calculate slenderness for both directions.
  3. Use the appropriate buckling curve before forming resistance.

Remember: Compare the final resistances; slenderness alone may not identify the controlling axis.

Related concept and full method

The source assumes rotational and positional restraint at level 2 in both axes.

The base is pinned.

Table 8.6 recommended fixed/pinned factor is 0.85.

Use that assumed model explicitly, rather than inferring a rigid base from the drawing’s plate line.

LEx=LEy=0.85×3,000=2,550mmλx=2,55089.6=28.459821λy=2,55052=49.038462Hot-rolled H-section, thickness ≤40mm, py=355: x axis uses curve b; y axis uses curve c. Curve b: 25 row gives 342,30 row gives 335Nmm2. Interpolation fraction: 28.459821−2530−25=0.691964pc=342+0.691964×(335−342)=337.156250Nmm2Curve c: 48 row gives 280,50 row gives 275Nmm2. Interpolation fraction: 49.038462−4850−48=0.519231pc=280+0.519231×(275−280)=277.403846Nmm2Pcx=7,640×337.1562501,000=2575.873750kNPcy=7,640×277.4038461,000=2119.365385kNPc=Pcy=2119.365385kN

Simple construction sets all m factors to 1.

For bending buckling use actual storey length 3,000mm, not 2,550mm:

λLT=0.5Lry=0.5×3,00052=28.846154Table 8.3a,py=355: 25 and 30 rows all give 355, giving pb=355. Mb=355×6561,000=232.88kN·mFlexural-buckling interaction: 1,103.62119.365385+1×56.838827207.32+0=0.794882<1Axial force/LTB interaction: 1,103.62119.365385+1×56.838827232.88+0=0.764791<1

Mechanism detailsA strong slice can belong to an unstable member5 concepts · 4 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Combine axial compression and the two bending demands using the specified section resistances.
  2. The whole member adds effective-length and buckling-curve effects.
  3. This uses its own moment factor and bending resistance.

    It is not a copy of the section check.

  4. Elastic, plastic and buckling resistances are not interchangeable.

    Read the three original expressions and their first-order/amplified moments.

7. Upper-storey governing moment and section interaction

Use the same mechanism: A strong cross-section can belong to an unstable member. At fixed moments and resistances, increasing compression increases utilisation. A section pass cannot remove the length-dependent instability checks.

Use the same mechanism: Two simultaneous actions use one component. At fixed resistances, increasing one demand increases its utilisation. The permitted sum is not always one.

Use the same mechanism: Compression acts on the displaced shape. At fixed axial force, a larger offset creates a larger additional moment. This can further increase the displacement.

Apply the reasoning to this section’s data and conditions

Roof reaction: R23=1.4×24+1.6×80=161.6kNRoof nominal moment: M3=161.6×0.2048=33.09568kN·mMoment allocated to the bottom of the upper column segment: 24.712533kN·m. Governing first-order moment magnitude: max(33.09568,24.712533)=33.09568kN·mMx,amp=MLT=1.15×33.09568=38.060032kN·mFc=309.6kN;My=0Usection=309.62,712.2+38.060032232.88=0.277583<1Upper-storey section passes.

The upper-storey moment is governed by the roof reaction, not automatically the moment inherited at level 2.

The source uses 162×0.205≈33.2, giving amplified 38.18≈38.2.

Its printed 0.27 comes from early rounding of the separate utilisation terms; full arithmetic is about 0.28 at two decimal places.

Mechanism detailsA strong slice can belong to an unstable member3 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Combine axial compression and the two bending demands using the specified section resistances.
  2. The whole member adds effective-length and buckling-curve effects.
  3. This uses its own moment factor and bending resistance.

    It is not a copy of the section check.

  4. Elastic, plastic and buckling resistances are not interchangeable.

    Read the three original expressions and their first-order/amplified moments.

8. Upper-storey buckling about both axes

Use the same mechanism: A strong cross-section can belong to an unstable member. At fixed moments and resistances, increasing compression increases utilisation. A section pass cannot remove the length-dependent instability checks.

Use the same mechanism: Check buckling about both axes. At fixed radius, longer effective length raises slenderness. The supplied buckling curve generally gives lower compressive strength.

Use the same mechanism: Vertical bending can trigger sideways motion. Adding a valid lateral restraint shortens a stability segment. It need not change the beam’s vertical reaction or moment diagram.

Apply the reasoning to this section’s data and conditions

The main roof beam supplies the source’s major-axis rotational restraint.

The small secondary roof ties only restrain position in the weak direction.

With level 2 restrained, the lecture uses 0.70L for x and 0.85L for y.

LEx=0.70×6,000=4,200mm;LEy=0.85×6,000=5,100mmλx=4,20089.6=46.875λy=5,10052=98.076923Curve b, 355 column: 46 row gives 306,48 row gives 302Nmm2. Interpolation fraction: 46.875000−4648−46=0.437500pc=306+0.437500×(302−306)=304.250000Nmm2Curve c, 355 column: 98 row gives 145,100 row gives 140Nmm2. Interpolation fraction: 98.076923−98100−98=0.038462pc=145+0.038462×(140−145)=144.807692Nmm2Pcx=7.64×304.250000=2324.470000kNPcy=7.64×144.807692=1106.330769kNMinor axis governs. Simple construction: λLT=0.5×6,00052=57.692308Table 8.3a,355 column: 55 row gives 274,60 row gives 257Nmm2. Interpolation fraction: 57.692308−5560−55=0.538462pb=274+0.538462×(257−274)=264.846154Nmm2Mb=264.846154×6561,000=173.739077kN·mFlexural-buckling interaction: 309.61106.330769+38.060032207.32=0.463425<1Axial force/LTB interaction: 309.61106.330769+38.060032173.739077=0.498908<1

Both storeys pass all three demonstrated interaction checks.

The lower-storey flexural interaction, approximately 0.795, is the largest.

The original source-rounded results are approximately lower 0.65/0.79/0.76 and upper 0.28/0.46/0.50.

Mechanism detailsA strong slice can belong to an unstable member6 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Combine axial compression and the two bending demands using the specified section resistances.
  2. The whole member adds effective-length and buckling-curve effects.
  3. This uses its own moment factor and bending resistance.

    It is not a copy of the section check.

  4. Elastic, plastic and buckling resistances are not interchangeable.

    Read the three original expressions and their first-order/amplified moments.

Result and concise exam wording

Use the same mechanism: Compression acts on the displaced shape. At fixed axial force, a larger offset creates a larger additional moment. This can further increase the displacement.

Use the same mechanism: An eccentric beam reaction bends the column. Equal opposite-face reactions can cancel a joint moment. Their downward forces still add to column compression.

Use the same mechanism: Two simultaneous actions use one component. At fixed resistances, increasing one demand increases its utilisation. The permitted sum is not always one.

Apply the reasoning to this section’s data and conditions

Using exact arithmetic: upper/lower compression 309.6/1,103.6kN. pᵧ355,Class 1; A𝗀pᵧ2,712.2 kN; section capacities 232.88/85.626kN·m; elastic 207.32/71.355.

e=204.8mm; level 2 moment 74.1376kN·m shares 49.4251/24.7125.

Amplified lower moment 56.8388; upper governing 38.0600.

Lower Pc=2,119.365kN,Mᵦ232.88; interactions 0.6510/0.7949/0.7648.

Upper Pc=1,106.331kN,Mᵦ173.7391; interactions 0.2776/0.4634/0.4989.

Both storeys adequate under the stated simple-construction restraint assumptions.

Misconceptions and checks

Use the same mechanism: Balance the isolated beam. Move the same load toward B. Reaction B increases because the load has a larger moment arm about A.

Apply the reasoning to this section’s data and conditions

  • Accumulate both levels for lower axial load.
  • Cancel opposite moments, not the underlying compressive reactions.
  • Share moment by IL, not equally and not by axial-force ratios.
  • Use actual storey length in 0.5L/rᵧ.
  • Do not treat a small roof tie as rotational restraint.

How the method transfers to a new variant

Use the same mechanism: Compression acts on the displaced shape. At fixed axial force, a larger offset creates a larger additional moment. This can further increase the displacement.

Use the same mechanism: An eccentric beam reaction bends the column. Equal opposite-face reactions can cancel a joint moment. Their downward forces still add to column compression.

Use the same mechanism: Find which plate buckles first. At fixed width, a thinner plate has a larger width-to-thickness ratio. Local buckling then becomes more restrictive.

Apply the reasoning to this section’s data and conditions

  1. Trace the loads above each column segment and keep dead/imposed components separate.
  2. Read actual storey heights, section properties and end restraints in both axes.
  3. For simple construction derive nominal eccentric moments and share them by IL.
  4. Classify the section and form the correct section and member resistances.
  5. Apply only the prescribed load reductions and moment amplification rules.
  6. Check every storey segment and report both the governing check and source assumptions.

Prediction with explained answer

Use the same mechanism: Compression acts on the displaced shape. At fixed axial force, a larger offset creates a larger additional moment. This can further increase the displacement.

Use the same mechanism: An eccentric beam reaction bends the column. Equal opposite-face reactions can cancel a joint moment. Their downward forces still add to column compression.

Apply the reasoning to this section’s data and conditions

Prediction and explained answer.

Invented variant: change only the upper-storey length from 6m to 3m, retaining the same column section and level 2 moment 74.1376kN·m.

How is that joint moment shared?

Answer and reasoning

The upper and lower IL values now match.

Therefore, each receives 74.13762=37.0688kN·m.

The lower amplified share becomes 42.62912kN·m.

This redistribution does not alter the accumulated axial loads.

Upper buckling lengths and 0.5L/rᵧ also change and must be recalculated.

The original upper resistance cannot be reused.

Mechanism detailsEccentric reactions and stiffness sharing2 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. A beam reaction can act away from the column centre even at a nominally pinned beam connection.
  2. .

    Opposing reactions can cancel part of the signed moment, while both still add compression.

  3. The course simple model distributes the joint moment in proportion to of the columns above and below.
  4. Equal relevant stiffness gives half each.

    A roof joint with no upper column is a different case.