Columns: buckling, eccentric reactions and combined forces
A compressed column can fail by local plate buckling, cross-section yielding, or overall member buckling.
Passing one does not prove the others.
This chapter follows LectureNotes/Ch 4_Column.pdf and the supplied HK2011 tables.
The numerical design scope is non-sway columns; sway theory is explained for recognition because it appears in the lectures.
Lecture examples are included immediately after the relevant concepts.
Expand an example to read its complete diagram, working, exam answer and self-check here.
1. Effective length belongs to an axis and a restraint model
Check buckling about both axes
Determine which buckling direction limits the compressed member.
Prediction, then explanation. At fixed radius, longer effective length raises slenderness. The supplied buckling curve generally gives lower compressive strength.
Calculate slenderness about each axis. Select each axis’s curve from section type and thickness. Then obtain and compare the two compressive resistances.
Effective lengths and radii use mm. pc is compressive strength in N/mm²; Ag is gross area in mm²; Pc is in N.
Scope. Do not select the governing axis using radius alone. Effective length and buckling curve can differ. A combined column also needs interaction checks.
Check and takeaway. A short-section yield resistance is not the same as long-member buckling resistance. Keep py and pc distinct.
Apply the reasoning to this section’s data and conditions
Physical interpretation: Why a long column can fail before crushing
Push a long thin ruler from both ends: it may bow sideways first.
Sketch, not to scale; use the original dimensions.
- Find effective length and radius of gyration for each axis.
- Calculate slenderness for both directions.
- Use the appropriate buckling curve before forming resistance.
Remember: Compare the final resistances; slenderness alone may not identify the controlling axis.
Slenderness measures how long and weak a member is in a particular buckling direction: λ=Lᴱ/.
Radius of gyration describes how far area lies from that bending axis.
Larger gives a smaller slenderness.
A weak-axis tie can improve resistance without changing the steel section.
It only helps the direction it actually restrains.
| Idealized restraint pattern in Table 8.6 | Theoretical | Recommended when ideal conditions are approximated |
|---|---|---|
| Both ends fixed against rotation and translation | ||
| One end fixed, other pinned; translation prevented | ||
| One end fixed, other rotation-fixed but translation-free | ||
| Both ends pinned, translation prevented | ||
| Fixed-free cantilever | ||
| Source sixth pattern with partial rotational restraint and free translation at top | Not specified |

Original Table 8.6, Ch 4 p.2: effective lengths of idealised columns.
Dashed lines indicate the buckled shape.
The six end-condition patterns, read left to right, and both rows of factors are reproduced in the table above.
From top to bottom, the legend means: rotation and translation fixed; rotation free and translation fixed; rotation fixed and translation free.
Both free; rotation partially restrained and translation free.
The source word “Transition” means translation here.
The page formula is , and .
Use the question’s explicitly given effective length if present.
Otherwise choose the source’s recommended factor for the modeled conditions, as the examples do.
Do not use textbook theoretical where the worked course method uses .
Pin symbols indicate free rotation, not free lateral translation.
Keep and in the same units.
Prediction and explained answer.
A6 m pinned column has a midheight tie effective only against weak-axis buckling.
Find Lᴱx and Lᴱy.
Answer and reasoning
; .
Major-axis buckling can still extend over the full height.
Mechanism detailsEffective length and buckling axes
The complete mechanism is explained below.
Read each stage together with its stated conditions; playback and interaction are not required.
- A column can bow sideways before its section reaches the crushing resistance.
- Each axis has its own radius of gyration and restraint spacing.
, with compatible length units.
A tie affects only the directions it actually restrains.
Select each buckling curve and compressive strength before forming Pc.
The governing axis is determined by resistance, not slenderness alone.
Mechanism detailsEffective length and buckling axes
The complete mechanism is explained below.
Read each stage together with its stated conditions; playback and interaction are not required.
- A column can bow sideways before its section reaches the crushing resistance.
- Each axis has its own radius of gyration and restraint spacing.
, with compatible length units.
A tie affects only the directions it actually restrains.
Select each buckling curve and compressive strength before forming Pc.
The governing axis is determined by resistance, not slenderness alone.
2. Select the buckling curve before reading compressive strength
Use the same mechanism: Check buckling about both axes. At fixed radius, longer effective length raises slenderness. The supplied buckling curve generally gives lower compressive strength.
A table value has conditions
Find a design property without mixing a row, column or standard from a different case.
Prediction, then explanation. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.
Match the complete section designation. Read the relevant axis and unit. For strength tables, select material, thickness and curve before interpolating.
Given values come from the question. Lookup values come from a named table. Assumed values require an explicit condition.
Scope. A missing row or omitted restraint cannot be recovered from a schematic’s scale. Keep the result conditional when required data are absent.
Check and takeaway. Record the table, row, column and unit beside the substitution. That makes a later check possible.
Move between two known values
The required slenderness lies between two table rows. Estimate the strength on the straight segment between those rows.
Prediction, then explanation. If the second strength is lower, moving toward that row must reduce the interpolated strength.
Subtract the lower input to find distance travelled. Divide by the input interval. Multiply that fraction by the output change.
x is the required input. The two known pairs are (x₀, y₀) and (x₁, y₁). f has no unit.
Scope. Use one table, curve and strength column. This interpolation does not permit extrapolation or inventing an intermediate steel section.
Check and takeaway. Illustration: between strengths 200 and 180, a fraction of 0.4 gives 192 N/mm². The result lies between both endpoints.
Apply the reasoning to this section’s data and conditions
Physical interpretation: A table lookup needs several keys
A table is like an address: knowing only the street is not enough.
Sketch, not to scale; use the original dimensions.
- Select the curve using section type, thickness and axis.
- Select the material-strength column.
- Bracket the slenderness and interpolate if required.
Remember: Do not jump between steel grades or extrapolate past supplied data.
First establish that the section is not slender.
For uniform compression the lecture checks flange and web , the semi-compact limits.
That permits the gross-area resistance .
It does not assert Class 1.
For combined bending and axial force, use the appropriate class limits before claiming plastic bending resistance.
| Section; maximum thickness | Curve about | Curve about |
|---|---|---|
| Rolled I; | ||
| Rolled I; | ||
| Rolled H (UC); | ||
| Rolled H; | ||
| Welded I or H; | ||
| Welded I or H; |
These rows are Table 8.7 in the Data File p.7.
The full source on Ch 4 p.4 also covers hollow sections, bars, angles, channels, cover plates and welded boxes.
The full table’s notes matter: thickness – permits the specified averaging treatment; fabrication and cover-plate geometry can alter the curve.
Do not select a curve solely from steel grade.

Full Table 8.7, Ch 4 p.4: section type, maximum thickness, buckling axis and special notes.
Each curve pair below is in the order /; thickness boundaries follow the source table.
Hot-finished structural hollow sections in steel above S460, or hot-finished seamless hollow sections: /.
Hot-finished hollow sections in steel below S460: /.
These two source rows say “above” and “below”.
Neither explicitly assigns exactly S460, so do not invent an equality boundary.
Cold-formed hollow sections with longitudinal or spiral welds: /.
Hot-rolled I-sections: thickness uses /; uses /.
Hot-rolled H-sections: for the same two thickness intervals, use respectively / and /.
Welded I/H-sections: use respectively / and /; also see note 2.
Hot-rolled sections with welded flange cover plates: select the row using the Figure 8.4 ratio .
When : for I-sections in the two thickness intervals above, use respectively / and /.
For H-sections, use respectively / and /.
When : for I/H-sections, use respectively / and /.
When : for I/H-sections, use respectively / and /.
Welded box sections: for the two thickness intervals above, use respectively / and /; also see note 3.
Round, square or flat bars: use respectively / and /.
Hot-rolled angles, channels and tees; two hot-rolled sections connected by lacing, battens or back to back; and built-up hot-rolled sections: for either axis, use .
Note 1: for thickness to , for the same relevant , average the values for thickness not exceeding and thickness exceeding of .
Note 2: for welded I/H-section flanges machine flame-cut without subsequent edge grinding or machining, when buckling about the axis, flange thickness not exceeding may use curve ; above that thickness, use .
Note 3: “welded box sections” includes boxes assembled from plates or hot-rolled sections with all longitudinal welds near the corners, but excludes boxes with longitudinal stiffeners.
Note 4: the source permits curves from other recognised codes when differences in load/material partial factors are addressed and the curves are calibrated against Tables 8.8(a₀), (a) to (h).
The Table 8.8 footnote also applies.
This does not supply numerical values that can simply be mixed with the course tables.Open full-size image
- Identify section family and fabrication, maximum thickness and buckling axis; choose its curve.
Confirm pᵧ from grade and thickness.
Select that strength column within the appropriate Table 8.8 curve.
Calculate for that axis and locate bracketing rows.
Interpolate .
Do not extrapolate beyond supplied tables.
Compute and .
Use the smaller for the flexural compression check.
Check both axes even if rᵧ is smaller: different effective lengths and different curves may change which controls.
Data File p.8 supplies S355 curves only over its printed rows.
The lecture and 2023 extra data contain further tables.
Choose a supplied applicable table and cite it.
Do not invent a value from the trend.
Column example 1: a pinned column in axial compression
Column example 2: a weak-axis tie permits a lighter section
Mechanism detailsEffective length and buckling axes
The complete mechanism is explained below.
Read each stage together with its stated conditions; playback and interaction are not required.
- A column can bow sideways before its section reaches the crushing resistance.
- Each axis has its own radius of gyration and restraint spacing.
, with compatible length units.
A tie affects only the directions it actually restrains.
Select each buckling curve and compressive strength before forming Pc.
The governing axis is determined by resistance, not slenderness alone.
3. Cross-section capacity: axial force consumes some of the same resistance
Use the same mechanism: A strong cross-section can belong to an unstable member. At fixed moments and resistances, increasing compression increases utilisation. A section pass cannot remove the length-dependent instability checks.
Two simultaneous actions use one component
Check a component that carries shear and tension, or compression and bending, at the same time.
Prediction, then explanation. At fixed resistances, increasing one demand increases its utilisation. The permitted sum is not always one.
First apply the individual checks. Next use the exact combined equation and its definitions. Keep demands from the same load case.
This is the course bolt interaction rule. Fs and Ft are bolt demands; Ps and Pnom are their specified resistance denominators.
Scope. The 1.4 limit and nominal tension denominator do not apply to column equations. Their limits and moment definitions are separate.
Check and takeaway. A sum above one can pass this bolt rule while still needing individual checks. A pass must name the actual equation used.
Apply the reasoning to this section’s data and conditions
Physical interpretation: The column needs more than one pass
A slice can be strong while the whole member still buckles.
Sketch, not to scale; use the original dimensions.
- Check cross-section compression plus bending.
- Then check the separate member-buckling expressions.
- Keep each moment, factor and resistance in its specified expression.
Remember: The three checks do not share interchangeable denominators.
is design compression at the critical section; and Mᵧ are design moments there, including the specified amplification.
is gross area.
Each ratio is dimensionless, so keep force units consistent and moment units consistent.
Use magnitudes for the conservative linear interaction; moments about perpendicular axes do not cancel.
If using maxima from different locations, label the check as a conservative envelope.
This lecture expression excludes Class 4 without an appropriate local-buckling treatment.
The minor-axis 1.2pᵧZᵧ ceiling frequently controls UC sections: calculating pᵧSᵧ alone overstates the allowed moment.
The axial denominator here is A𝗀pᵧ, not the reduced member resistance .
Mechanism detailsA strong slice can belong to an unstable member
The complete mechanism is explained below.
Read each stage together with its stated conditions; playback and interaction are not required.
- Combine axial compression and the two bending demands using the specified section resistances.
- The whole member adds effective-length and buckling-curve effects.
This uses its own moment factor and bending resistance.
It is not a copy of the section check.
Elastic, plastic and buckling resistances are not interchangeable.
Read the three original expressions and their first-order/amplified moments.
4. Member buckling: keep the source’s barred quantities distinct
Use the same mechanism: A strong cross-section can belong to an unstable member. At fixed moments and resistances, increasing compression increases utilisation. A section pass cannot remove the length-dependent instability checks.
Apply the reasoning to this section’s data and conditions
Physical interpretation: The column needs more than one pass
A slice can be strong while the whole member still buckles.
Sketch, not to scale; use the original dimensions.
- Check cross-section compression plus bending.
- Then check the separate member-buckling expressions.
- Keep each moment, factor and resistance in its specified expression.
Remember: The three checks do not share interchangeable denominators.
The source uses bars to distinguish first-order moments and some resistance definitions.
Small overbars can disappear in extracted text, so read the original image.
Here “Mᵧ,first” explicitly means the source’s barred Mᵧ.
“” and “Mᵧ,amp” include the required amplification.
Elastic moment denominators in these member equations are pᵧZ, even for a Class 1 section.
Non-sway flexural-buckling interaction (course Eq.8.80): Combined axial force/LTB (Eq.8.81):
For the non-sway worked method, is the smaller axis resistance based on the stated/computed effective lengths; specifically uses weak-axis buckling.
Mᴸᵀ is the amplified major-axis moment governing lateral-torsional resistance, often given separately by an exam question.
Do not amplify a supplied “already amplified” Mᴸᵀ twice.
The last term of Eq.8.81 uses first-order minor-axis moment in the supplied source.
The flexural equation uses the amplified one.
This explains the apparently different and values in Example 5.

Ch 4 p.15: original Eqs.8.79–8.81 and their definitions.
Overbars are retained as printed.
These are the source symbols.
The renamed teaching symbol , used above is not substituted into the original equations.
Eqn 8.79: Eqn 8.80: Eqn 8.81: Source definitions: is the design compressive force at the critical location; , are the compression resistances about the two axes in sway mode.
is the smaller of these.
is the smaller of the two non-sway compression resistances, obtained by second-order analysis or by taking effective length equal to actual member length.
is the buckling moment resistance under clause 8.3.5.2.
, are the maximum major- and minor-axis design moments already amplified for effects; , are the corresponding first-order linear-analysis moments.
is the amplified major-axis moment governing .
In this source figure, , denotes elastic moment resistance.
, comes from Table 8.9; comes from Table 8.4.Open full-size image
For sway recognition only, Eq.8.79 uses sway-mode compression resistance with first-order end moments, while Eq.8.80 uses the alternative non-sway-mode compression resistance with amplified moments.
Eq.8.81 adds axial/LTB interaction.
The source explains that different lateral-load/initial-curvature effects can control.
Its p.17 explicitly excludes numerical sway-column design from the course.
The worked pages therefore use the non-sway branches rather than constructing an unsupported sway analysis.
Mechanism detailsA strong slice can belong to an unstable member
The complete mechanism is explained below.
Read each stage together with its stated conditions; playback and interaction are not required.
- Combine axial compression and the two bending demands using the specified section resistances.
- The whole member adds effective-length and buckling-curve effects.
This uses its own moment factor and bending resistance.
It is not a copy of the section check.
Elastic, plastic and buckling resistances are not interchangeable.
Read the three original expressions and their first-order/amplified moments.
5. Non-sway, sway and ultra-sensitive frames
Restraints define the analysis model
Choose an analysis model that represents the actual joints, restraints and possible sway.
Prediction, then explanation. A joint that permits beam rotation does not automatically remove all column moment. Eccentric reactions may still bend the column.
First identify the joint behaviour. Next identify how horizontal forces reach the foundations. Then assess sway sensitivity using the course criterion.
Simple, continuous and semi-continuous construction describe joint modelling. Sway classification describes overall frame response.
Scope. The schematic does not establish restraint stiffness or a stability threshold. Use the stated data and classification rules.
Check and takeaway. An ideal straight frame may still require notional horizontal forces to represent imperfections under the applicable method.
Compression acts on the displaced shape
A compressed member moves away from its initial load line. Explain why the bending moment can increase.
Prediction, then explanation. At fixed axial force, a larger offset creates a larger additional moment. This can further increase the displacement.
Force acting through an offset forms a moment. Second-order analysis includes that changed geometry in equilibrium.
P is axial force. Δ and δ are the relevant perpendicular displacements. Consistent force and length units give moment units.
Scope. Use the amplification or analysis method stated for the frame. Do not amplify an already amplified moment a second time.
Check and takeaway. Zero offset removes this additional moment in the ideal sketch. Real design may still require imperfections and code checks.
Apply the reasoning to this section’s data and conditions
| Source analysis route | Non-sway | Sway | Ultra-sensitive |
|---|---|---|---|
| Ordinary course route | |||
| Advanced-analysis classification quoted by lecture |
is the elastic critical load factor: the multiple of the applied loading at which an elastic instability mode occurs.
It is not the member slenderness λ=Lᴱ/r.
Non-sway classification permits the stated global simplification; local member amplification may still be needed.
For ultra-sensitive frames the lecture requires second-order or advanced analysis.
Bracing is the physical system restraining sway.
The classification checks how sensitive the modeled structure is.
Mechanism detailsRestraints, sway and imperfections
The complete mechanism is explained below.
Read each stage together with its stated conditions; playback and interaction are not required.
- A frame needs a defined path for horizontal force as well as gravity.
- Pinned joints alone do not provide frame moment resistance; sway restraint needs a real structural system.
Diagonal bracing carries horizontal action through axial forces.
This sketch does not assign a numerical frame classification.
Use the specified imperfection/notional-force model and critical-load criteria.
Avoid counting alternative imperfection models twice.
6. Why moments increase under compression
Use the same mechanism: Compression acts on the displaced shape. At fixed axial force, a larger offset creates a larger additional moment. This can further increase the displacement.
Apply the reasoning to this section’s data and conditions
Physical interpretation: Moving sideways gives the load a new lever arm
Once a compressed member moves sideways, the same compression creates extra moment.
Sketch, not to scale; use the original dimensions.
- P–Δ concerns overall frame or storey movement.
- P–δ concerns bowing relative to the member’s end line.
- Amplify only the first-order moments specified by the method.
Remember: Do not amplify a moment that the question already gives as amplified.
A compression force acting through a lateral displacement creates additional moment.
Capital usually denotes frame/storey sway; small denotes member curvature.
Second-order analysis can include these effects directly.
If the exercise instead gives amplification factors, multiply the appropriate first-order moment once.
Global amplification factor: Member amplification factor:
is the factored vertical load at and above the storey.
Fᴺ is the notional horizontal load.
is storey height. δᴺ is relative storey displacement caused by Fᴺ.
The lecture uses the larger relevant global/member factor for its general discussion.
For non-sway member design it specifies the local member factor.
Use a consistent force/length system so both denominator ratios are dimensionless.
A nonpositive denominator does not mean a negative useful amplification: the approximation has reached/breached its instability condition.
Prediction and explained answer.
Invented arithmetic: , Fᴺ/Fᵥ=0.005, δᴺ=2 mm.
Find and the global factor.
Answer and reasoning
.
The ordinary route is at the non-sway boundary.
The displayed global factor is .
A separate member effect may still govern.
Mechanism detailsSeparate P–Δ from P–δ
The complete mechanism is explained below.
Read each stage together with its stated conditions; playback and interaction are not required.
- The dashed line marks the original frame position; axial compression acts downwards.
- Global displacement Δ creates the additional moment PΔ.
- Local displacement δ is measured from the line joining the displaced ends, and adds Pδ.
Follow the original analysis route.
Do not amplify an already amplified moment or confuse critical-load factor with member slenderness.
Mechanism detailsSeparate P–Δ from P–δ
The complete mechanism is explained below.
Read each stage together with its stated conditions; playback and interaction are not required.
- The dashed line marks the original frame position; axial compression acts downwards.
- Global displacement Δ creates the additional moment PΔ.
- Local displacement δ is measured from the line joining the displaced ends, and adds Pδ.
Follow the original analysis route.
Do not amplify an already amplified moment or confuse critical-load factor with member slenderness.
7. Flexural moment factors are not the LTB factors
Moment shape matters within one segment
Represent a nonuniform moment distribution in the applicable member-buckling equation.
Prediction, then explanation. Two segments can have equal peak moment but different distributions. Their equivalent moment factors can therefore differ.
Evaluate moments from the true whole-beam analysis at the required positions. Apply the exact table’s weights, signs and lower bound.
mLT is an LTB factor. mx and my belong to the specified flexural checks. They are not interchangeable.
Scope. Some rules use magnitudes; others require signed ordinates. A factor does not reduce the actual moment used in a local section check.
Check and takeaway. Measure quarter points from the segment start, not automatically from the beam’s left support.
Apply the reasoning to this section’s data and conditions
Physical interpretation: Similar-looking moment factors come from different tables
Two recipes can use the same ingredients but different amounts.
Sketch, not to scale; use the original dimensions.
- Identify flexural buckling or lateral-torsional buckling first.
- Read the actual moment diagram, including any change of sign.
- Use that check’s table and its own sign and minimum-factor rules.
Remember: Table 8.9 flexural factors are not Table 8.4 LTB factors.
For an end-moment-only segment, read Table 8.9 with the signed internal end-moment ratio .
positive means the BMD stays on the same side; negative means it reverses.
The lecture’s column-end applied-arrow convention gives ; confirm the actual arrow/BMD rather than applying that minus sign blindly to internal BMD ordinates.
When : .
When : .
For example, ; .
But Table 8.4a for LTB, at , gives .
The two tables differ especially for reversing bending.
They also have different general quarter-point formulas.
For Table 8.9:
and are quarter-point moments.
is mid-length moment.
is the maximum moment magnitude in the central half.
If the three ordinates lie on one side, take them positive.
If they straddle the axis, choose the positive side that gives the larger .
and are always positive.
This sign rule differs from Table 8.4b, which uses all magnitudes.
The lecture’s special flexural cases give for one central point, for a UDL, for three equal equally spaced points and for the pictured two equal points; match the drawing before using them.

Table 8.9, Ch 4 p.18: special cases and sign rules for the general case.
X marks lateral restraint; / marks segment length.
The two end moments above are and .
In the left sketch, is positive; in the right sketch, is negative.
The end-moment table gives row by row as follows: ,,,,,,,,,,,,,,,,,,,,.
The special cases at lower left, from top to bottom, are: one point load at midspan, ; UDL, ; three equal, equally spaced point loads, ; two equal point loads at the third points, .
In the lower-right sketch, , are the ends; , are the quarter points.
is the midpoint.
The source expression is:but .
If all three sampled moments lie on the same side, take them positive.
If they lie on different sides, choose as positive the side producing the larger .
, are both positive: respectively the maximum moment over the whole segment and over its central half.Open full-size image
Column example 5: axial load plus biaxial end moments
Mechanism detailsRead the moment shape within one segment
The complete mechanism is explained below.
Read each stage together with its stated conditions; playback and interaction are not required.
- Moment ordinates must belong to the same effective unbraced segment.
- Same-side and reverse-curvature diagrams have different signed end ratios.
- The markers show ¼, ½ and ¾ of this segment, not of the entire beam.
LTB and column flexural factors are different.
Preserve their individual bounds and coefficient sets.
8. Simple construction: eccentric reactions still bend columns
An eccentric beam reaction bends the column
A simple beam joint delivers a vertical reaction away from the column centre. Find the resulting column moments.
Prediction, then explanation. Equal opposite-face reactions can cancel a joint moment. Their downward forces still add to column compression.
Sum axial forces first. Calculate the signed eccentric moments. Share the net joint moment between upper and lower columns using the stated stiffness model.
R is reaction; e is perpendicular eccentricity. K denotes the stiffness measure prescribed for moment sharing.
Scope. Equal sharing requires equal stated stiffness. Use actual storey length where the special simple-construction LTB rule requires it.
Check and takeaway. A pin-like beam connection can still cause an eccentric reaction moment in the column. Joint rotation and reaction location are separate facts.
Apply the reasoning to this section’s data and conditions
Physical interpretation: A pinned beam can still bend its column
Its reaction can miss the column centre and create a lever arm.
Sketch, not to scale; use the original dimensions.
- Find the reaction’s actual nominal eccentricity.
- Multiply reaction by eccentricity to obtain the joint moment.
- Share that moment using the stated column-stiffness model.
Remember: Equal sharing needs equal relevant stiffness.
It is not automatic.
A simple beam-to-column joint does not transmit a rigid-frame end moment.
Its vertical reaction may still act away from the column centre.
The nominal eccentricity is measured from the column centroid to the reaction line.
For a beam resting on a column face, compare two possible reaction positions.
The first is from that face.
The second is the centre of stiff bearing.
Use the position farther from the face.
Add the centroid-to-face distance (for the illustrated major-axis case, ).
For identical sections above and below, cancels.
A3 m lower column is twice as stiff by as a upper one, so shares are and .
Opposite equal reactions cancel their nominal moments about that axis but still add to axial compression.
The upper column carries roof loads.
The lower carries roof plus intermediate-floor loads.
Do not distribute accumulated axial load using the moment-stiffness fractions.
The source allows all beams fully loaded without pattern loading for this simplified column procedure.
It also says a beam loaded above of its capacity should not be assumed to afford column rotational restraint.
These are applicability conditions, not universal properties of every beam connection.
The special 0.5L/rᵧ rule uses actual , not the reduced effective column length.
Column example 3: loads and eccentric moments in two storeys
Column example 4: tributary area and cumulative column loads
Mechanism detailsEccentric reactions and stiffness sharing
The complete mechanism is explained below.
Read each stage together with its stated conditions; playback and interaction are not required.
- A beam reaction can act away from the column centre even at a nominally pinned beam connection.
.
Opposing reactions can cancel part of the signed moment, while both still add compression.
- The course simple model distributes the joint moment in proportion to of the columns above and below.
Equal relevant stiffness gives half each.
A roof joint with no upper column is a different case.
9. A repeatable exam sequence
Use the same mechanism: Check buckling about both axes. At fixed radius, longer effective length raises slenderness. The supplied buckling curve generally gives lower compressive strength.
Use the same mechanism: A strong cross-section can belong to an unstable member. At fixed moments and resistances, increasing compression increases utilisation. A section pass cannot remove the length-dependent instability checks.
Apply the reasoning to this section’s data and conditions
- Identify simple or continuous construction, sway status, column segment, effective lengths in both axes, section and grade.
- Assemble factored axial load at each level; derive any eccentric moments or read given end moments.
Read exact section properties and thickness-dependent pᵧ.
Classify local elements under the applicable stress pattern.
- Compute capped section moment resistances and check the axial/biaxial section interaction.
- Calculate and , choose the proper curves, interpolate and form both axis resistances.
For continuous construction obtain , and mᴸᵀ from their separate tables.
For simple construction set all three to .
- Use the correct amplified/first-order moments and elastic pᵧZ denominators for flexural interaction.
Compute λᴸᵀ using the appropriate simple/continuous rule.
Read pᵦ, calculate Mᵦ and check Eq.8.81.
- State all utilisation ratios and whether every required check is.
Mechanism detailsEffective length and buckling axes
The complete mechanism is explained below.
Read each stage together with its stated conditions; playback and interaction are not required.
- A column can bow sideways before its section reaches the crushing resistance.
- Each axis has its own radius of gyration and restraint spacing.
, with compatible length units.
A tie affects only the directions it actually restrains.
Select each buckling curve and compressive strength before forming Pc.
The governing axis is determined by resistance, not slenderness alone.
Practise this chapter: tutorials, assignments and past-paper answers →
Recent-paper practice for this chapter
- 2024 PTE · Column check
- 2023 FT/PTD · 2023 BQ3 — column with biaxial bending
- 2023 PTE · Column check
- 2022 FT/PTDR · 2022 BQ2 — column with biaxial bending