STEELWORK / CON4334
Learn

Connections: trace the force through bolts, plates and welds

Chinese–English terminology

Bolt grades and weld types Often examined

Source: Chapter 2 pp.2–3 and 6–7.Ordinary bolts sit in slightly larger holes; under load the shank presses on the hole wall to pass the force. Friction-grip (HSFG) bolts work by clamping and friction and need a different check. The course design strengths for Grade 8.8 are ps=375p_s=375, pbb=1000p_{bb}=1000 and pt=560 N/mm2p_t=560\text{ N/mm}^2. The other number, Ub=800U_b=800, is the bolt’s ultimate tensile strength, used only in the cap of the plate-bearing formula.

What “8.8” means: the first 8 → ultimate strength 800 N/mm²; the second 8 → yield is 0.8 of that, i.e. 640 N/mm². But capacities use the design strengths above, not these two numbers. (Grade 4.6: 240 / 400; Grade 10.9: 900 / 1000.)

Chapter 2 p.7, Figure 3. A fillet joins intersecting surfaces; butt welds use prepared grooves. The leg and throat are different dimensions.
Chapter 2 p.7, Figure 3: weld leg and throat are different dimensions. The original labels identify Single V butt weld, Fillet weld, Single U/Double V/Double U preparations, Partial butt weld and Deep penetration fillet weld. Local labels identify Root, Angle of faces, Reinforcement, Gap and Throat; Size=leg length means the specified dimension equals the leg length; Fusion zone identifies the fused region. The middle detail in sketch (d) combines a partial-penetration butt weld with fillet welds.Open full-size image

A fillet weld has a triangular cross-section; a “6 mm weld” means the leg ss, not the throat. A butt weld joins plate edges that have been prepared (V or U shapes). To inspect welds: visual, dye penetrant and magnetic particle methods find surface defects; ultrasonic and X-ray methods find internal ones.

Animation labCount the bolt shear planes3 concepts · 5 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. Load must cross an interface between the connected plates.
  2. A lap joint gives one shear plane through a bolt.
  3. A symmetric double-cover joint may provide two shear planes. Count load-transfer interfaces, not just visible plates.
  4. Use the source’s area and shear strength. Then check bearing, plate resistance and detailing separately.

Hole size, spacing and edge distances Background

Simple explanation: The bolt can crush or tear the plate

A strong bolt can still push through a weak hole edge.

The bolt can crush or tear the plate — A strong bolt can still push through a weak hole edge.
Sketch, not to scale; use the original dimensions.
  1. Check the bolt and each connected plate’s bearing bounds.
  2. Use nominal bolt diameter for bearing; hole size for removed material.
  3. The smallest applicable resistance controls.

Remember: A short end distance may govern even when bolt shear passes.

Related concept and full method

Source: Chapter 2 pp.3–4.dd is the bolt’s nominal diameter; the hole d0d_0 is bigger: d+2 mmd+2\text{ mm} up to M24, d+3 mmd+3\text{ mm} for larger ordinary bolts. Bearing areas and spacing rules use dd; steel removed by holes uses d0d_0.

Chapter 2 p.4, Table 9.3 extract: choose the bolt size row and the correct edge-manufacture column.
Chapter 2 p.4, Table 9.3 extract: minimum end and edge distances for standard holes. Each pair gives, first, sheared/hand flame-cut edges and, second, rolled plate/section/bar edges or machine gas-cut edges, in mm. Source rows: M12: 22/18; M16: 28/22; M18: 32/24; M20: 34/26; M22: 38/28; M24: 42/30; M27 and above: 1.75d/1.25d. First select the bolt-size row, then the edge preparation.Open full-size image
Minimum pitch along the load direction: 2.5d.
General minimum gauge transverse to the load: 3d.
Maximum pitch/gauge: min(12t,150mm), where t is the thinner connected-plate thickness.
Maximum edge distance: 11tε; ε=275py.

End distance: from the hole centre to the plate end, along the force. Edge distance: from the hole centre to the side edge. The minimum depends on how the edge was cut: for M20, 34 mm for sheared or hand-flame-cut edges, 26 mm for rolled or machine-cut edges. End distance also affects plate bearing (see B2B_2 in the bearing section).

Animation labBolt centres, holes and edges1 concept · 2 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. Hole diameter d₀ differs from nominal bolt diameter d. Net-section deductions use the specified hole.
  2. Pitch runs along the load direction; gauge measures spacing across rows.
  3. End and edge distances start at the hole centre. The remaining ligament starts at the hole boundary.
  4. Minimum spacing, edge distances, grip and plate thickness come from the specified rules, not this scaled illustration.

Five ways a bolted joint can fail Always examined

Source: Chapter 2 p.8.Possible failures: (1) the bolt shears across; (2) the bolt or hole edge is crushed (bearing); (3) the plate tears across the holes (net section); (4) a short plate end tears out; (5) a block of steel bounded by shear and tension lines pulls out (block shear). A bigger bolt does not always help: its bigger hole removes more plate.

Follow the force path: main plate → bolts or weld → cover or gusset plate → the other member. Parts in series: take the smallest. Parts side by side sharing the load (e.g. two identical cover plates): add them. The bolt groups on the two sides of a splice are in series: each side must carry the full force.

Understanding map: Bolted joint: four routes, and the weakest one wins

Understanding map

Bolted joint: four routes, and the weakest one wins

The four checks (bolt shear, bolt bearing, angle bearing, angle tension) are four separate routes that meet at the weakest link. Watch the counting boxes at the top: the number of bolts, shear planes and plate thicknesses feed almost every route. The values are from 2024 BQ2(a).

Text version (in working order)

  1. From the question

    A×B×tA\times B\times t Angle size

    The 125 mm leg is bolted to the UC web (connected leg); the 75 mm leg sticks out (outstanding leg).

  2. From the question

    pp, ee Pitch, end distance

    Pitch 80 mm (hole centre to hole centre); end distance 50 mm (hole centre to the angle end, along the force).

  3. From the tablesWhere marks are lost

    dd, d0d_0, AsA_s M20 Grade 8.8 bolt

    Diameter dd is for bearing; hole diameter d0d_0 for net area and clear gaps; AsA_s for shear.

    2024 BQ2(a)

    d=20,  d0=22,  As=245 mm2;  ps=375,  pbb=1000,  Ub=800d=20,\;d_0=22,\;A_s=245\text{ mm}^2;\;p_s=375,\;p_{bb}=1000,\;U_b=800

    Where it comes from: Data File p.4.

  4. From the tables

    pyp_y, pbsp_{bs}, UsU_s S355 angle data

    The angle material: pyp_y for tension, pbsp_{bs} and UsU_s for bearing.

    2024 BQ2(a)

    py=355,  pbs=550,  Us=510,  Ke=1.1p_y=355,\;p_{bs}=550,\;U_s=510,\;K_e=1.1
  5. Worked out

    a1a_1, a2a_2 Leg areas

    Share the corner equally: each leg length minus t/2t/2, times tt.

    Formula

    a1=(A−t2)ta2=(B−t2)ta_1=\left(A-\tfrac t2\right)t\qquad a_2=\left(B-\tfrac t2\right)t

    2024 BQ2(a)

    (125−4)×8=968(75−4)×8=568 mm2(125-4)\times8=968\qquad(75-4)\times8=568\text{ mm}^2
  6. From the questionWhere marks are lost

    nn, nsn_s Bolts, shear planes

    3 bolts; count the shear planes on the side view: angle / UC web / angle → 2 (double shear).

  7. From the questionWhere marks are lost

    tpt_p Plate thicknesses

    The UC web in the middle is 12 mm; each angle is 8 mm.

  8. From the tablesWhere marks are lost

    kk Outstanding-leg factor

    Only one leg is connected, so the other cannot work fully. Double angles (both sides), bolted → 0.25.

    Where it comes from: Single angle 0.5 / 0.3; double angles 0.25 / 0.15 (bolted / welded).

  9. Worked out

    lcl_c Clear gap between holes

    The length of steel actually left between two holes.

    Formula

    lc=p−d0l_c=p-d_0

    2024 BQ2(a)

    80−22=58 mm80-22=58\text{ mm}
  10. Worked outWhere marks are lost

    AeA_e Effective area

    Deduct the holes on one cross-section line from the connected leg, multiply by KeK_e (not above the gross area), then add the other leg.

    Formula

    an1=a1−n d0 tae1=min⁡(Kean1,  a1)Ae=ae1+a2a_{n1}=a_1-n\,d_0\,t\qquad a_{e1}=\min(K_ea_{n1},\;a_1)\qquad A_e=a_{e1}+a_2

    2024 BQ2(a)

    an1=968−22×8=792ae1=min⁡(871.2, 968)=871.2Ae=1439.2 mm2a_{n1}=968-22\times8=792\qquad a_{e1}=\min(871.2,\,968)=871.2\qquad A_e=1439.2\text{ mm}^2
  11. From the question

    FF Design tension

    The factored design tension (kN). The two angles share it: 175 kN each.

  12. Capacity

    n nsPsn\,n_sP_s ① Bolt shear

    Will a bolt be cut? One PsP_s for every shear plane.

    Formula

    Ps=psAs1000  per planetotal=n ns PsP_s=\frac{p_sA_s}{1000}\;\text{per plane}\qquad\text{total}=n\,n_s\,P_s

    2024 BQ2(a)

    Ps=375×2451000=91.8753×2×91.875=551.25 kNP_s=\frac{375\times245}{1000}=91.875\qquad3\times2\times91.875=551.25\text{ kN}
  13. Capacity

    n Pbbn\,P_{bb} ② Bolt bearing

    Will the bolt itself be crushed by the hole edge? tpt_p is the weaker side: the middle plate vs the two outer plates added, whichever is smaller.

    Formula

    Pbb=d tp pbb1000P_{bb}=\frac{d\,t_p\,p_{bb}}{1000}

    2024 BQ2(a)

    tp=min⁡(12,  8+8)=12Pbb=20×12×10001000=2403×240=720 kNt_p=\min(12,\;8+8)=12\qquad P_{bb}=\frac{20\times12\times1000}{1000}=240\qquad3\times240=720\text{ kN}
  14. Capacity

    Bmin⁡B_{\min} ③ Angle bearing

    Will the angle around a hole crush or tear out? Write all three numbers and take the smallest; each angle has tp=8t_p=8.

    Formula

    B1=dtppbs1000B2=0.5 e tppbs1000B3=min⁡(1.5lctpUs,  2dtpUb)1000B_1=\frac{dt_pp_{bs}}{1000}\quad B_2=\frac{0.5\,e\,t_pp_{bs}}{1000}\quad B_3=\frac{\min(1.5l_ct_pU_s,\;2dt_pU_b)}{1000}

    2024 BQ2(a)

    B1=88,  B2=110,  B3=min⁡(354.96, 256)=256  ⇒  88 kN/bolt;  2×3×88=528 kNB_1=88,\;B_2=110,\;B_3=\min(354.96,\,256)=256\;\Rightarrow\;88\text{ kN/bolt};\;2\times3\times88=528\text{ kN}
  15. Capacity

    PtP_t ④ Angle tension

    Will the angle tear across the holes? The outstanding leg is reduced by k a2k\,a_2.

    Formula

    Pt=py (Ae−k a2)1000P_t=\frac{p_y\,(A_e-k\,a_2)}{1000}

    2024 BQ2(a)

    355×(1439.2−0.25×568)1000=460.5 kN per angle;  2×460.5=921.0 kN\frac{355\times(1439.2-0.25\times568)}{1000}=460.5\text{ kN per angle};\;2\times460.5=921.0\text{ kN}
  16. Check

    min⁡≥F\min\ge F Weakest link

    Each of the four must exceed the design tension; the joint is only as strong as the weakest — here, angle bearing.

    2024 BQ2(a)

    min⁡(551.25,  720,  528,  921.0)=528 kN>350  ✓\min(551.25,\;720,\;528,\;921.0)=528\text{ kN}>350\;\checkmark

Tour steps

  1. 1. Count first

    Most connection marks are lost by miscounting: bolts, shear planes, the thinnest plate, pitch and end distance.

  2. 2. Look up the data

    Copy the bolt data (d,d0,As,ps,pbbd,d_0,A_s,p_s,p_{bb}) and the angle data (py,pbs,Us,Kep_y,p_{bs},U_s,K_e) separately.

  3. 3. ① Bolt shear

    Bolts × shear planes × PsP_s.

  4. 4. ② Bolt bearing

    tpt_p is the smaller of the middle plate and the two outer plates added (12 mm).

  5. 5. ③ Angle bearing: smallest of three

    Work out the clear gap lcl_c, write B1,B2,B3B_1,B_2,B_3 and take the smallest, 88 kN per bolt.

  6. 6. ④ Angle tension

    Leg areas → effective area → reduce the outstanding leg → PtP_t.

  7. 7. The weakest link

    The four routes meet here: 528 kN (angle bearing) is the smallest and still above 350 kN → adequate.

Animation labCount the bolt shear planes4 concepts

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. Load must cross an interface between the connected plates.
  2. A lap joint gives one shear plane through a bolt.
  3. A symmetric double-cover joint may provide two shear planes. Count load-transfer interfaces, not just visible plates.
  4. Use the source’s area and shear strength. Then check bearing, plate resistance and detailing separately.

Bolt shear: count the shear planes first Always examined

Simple explanation: Count where the bolt can be sheared

The plate interfaces are the places trying to cut across the bolt.

Count where the bolt can be sheared — The plate interfaces are the places trying to cut across the bolt.
Sketch, not to scale; use the original dimensions.
  1. Count actual loaded shear planes, not merely visible plates.
  2. Choose shank or threaded area for the plane concerned.
  3. Compare group resistance with the force that group transfers.

Remember: Bolts on opposite sides of a splice do not all act in parallel.

Related concept and full method

Chapter 2 p.3, Figure 2: the left lap joint has one shear interface; the central plate between two covers gives two interfaces.
Chapter 2 p.3, Figure 2: single shear at left, double shear at right. The upper side views show the plate layers; the lower plans show hole positions. Labels identify end distance, edge distance and centre spacing. F and the load arrows show forces pulling the joint apart. The two shear interfaces come from sandwiching the main plate between two cover plates, not from having two rows of holes in plan.Open full-size image

The thread may lie in the shear plane, so use the tensile stress area AsA_s (smaller and safer); use the full shank area only if you are sure there is no thread there. Common values: M16 157, M20 245, M24 353, M30 561 mm².

One shear plane: Ps=psAs1,000kNTwo identical shear planes: Ps,total=2psAs1,000kN

“÷1000” turns N into kN: N/mm2×mm2=N\text{N/mm}^2\times\text{mm}^2=\text{N}. If the force passes through the centroid of the group, each bolt takes P/nP/n. If the force is off-centre there is also a twist (see the eccentric bolt group section); P/nP/n alone underestimates it.

Try it yourself. A Grade 8.8 M20 bolt has threads in two shear planes. Find its shear capacity.

Reveal answer and reasoning

2×375×2451,000=183.75kN. One-plane capacity is 91.875kN. Double shear is a geometry fact, not a property of Grade 8.8.

Animation labCount the bolt shear planes1 concept · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. Load must cross an interface between the connected plates.
  2. A lap joint gives one shear plane through a bolt.
  3. A symmetric double-cover joint may provide two shear planes. Count load-transfer interfaces, not just visible plates.
  4. Use the source’s area and shear strength. Then check bearing, plate resistance and detailing separately.
Animation labCount the bolt shear planes1 concept · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. Load must cross an interface between the connected plates.
  2. A lap joint gives one shear plane through a bolt.
  3. A symmetric double-cover joint may provide two shear planes. Count load-transfer interfaces, not just visible plates.
  4. Use the source’s area and shear strength. Then check bearing, plate resistance and detailing separately.

Bearing: will the bolt or the hole edge be crushed? Always examined

Simple explanation: The bolt can crush or tear the plate

A strong bolt can still push through a weak hole edge.

The bolt can crush or tear the plate — A strong bolt can still push through a weak hole edge.
Sketch, not to scale; use the original dimensions.
  1. Check the bolt and each connected plate’s bearing bounds.
  2. Use nominal bolt diameter for bearing; hole size for removed material.
  3. The smallest applicable resistance controls.

Remember: A short end distance may govern even when bolt shear passes.

Related concept and full method

Source: Chapter 2 pp.9–10.Bearing is local crushing where a bolt presses on its hole. The bearing area is d×tpd\times t_p (the projected area), not the circle πd2/4\pi d^2/4. For a double-cover splice, compare the main plate thickness with the two cover plates together and take the smaller; or check the main plate with the full force and each cover with half.

Bolt bearing: Pbb=dtppbb1,000Connected-plate resistance corresponding to each bolt is min(B1,B2,B3), where:B1=kbsdtppbs1,000B2=0.5kbsetppbs1,000B3=min(1.5lctpUs,2dtpUb)1,000

d, tp, e, lcd,\,t_p,\,e,\,l_c are in mm. ee = end distance (along the force); lcl_c = clear gap between neighbouring holes = pitch − d0d_0 (lcl_c is a length, not a second moment IcI_c). Standard holes: kbs=1k_{bs}=1. S355: pbs=550p_{bs}=550, Us=510U_s=510; Grade 8.8 bolt Ub=800 N/mm2U_b=800\text{ N/mm}^2.

Each of the three values is a different failure: B1B_1 the hole edge crushes; B2B_2 the end distance is too short and the plate end tears out; B3B_3 the steel between two holes tears (with an upper cap). Write all three and take the smallest.

Animation labBearing and the remaining ligament1 concept · 5 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. Force transfers through contact between bolt and connected plate.
  2. The plate around the hole carries bearing stress. Bolt bearing and plate bearing are separate checks.
  3. A short ligament can tear out towards the end. The direction of force determines the relevant edge.
  4. Evaluate every specified bearing and ligament bound for each layer and retain the smallest applicable resistance.

Bolts in tension Often examined

Simple explanation: Why the top bolt row is pulled hardest

The bracket tries to peel away from the support about the assumed contact line.

Why the top bolt row is pulled hardest — The bracket tries to peel away from the support about the assumed contact line.
Sketch, not to scale; use the original dimensions.
  1. Use the rotation/contact line assumed by the course model.
  2. Measure each bolt row’s distance from that line.
  3. Check maximum tension, direct shear and their interaction.

Remember: A row at the pivot can still carry direct shear.

Related concept and full method

Source: Chapter 2 pp.10–11.Tension acts along the bolt’s axis, trying to pull the joined surfaces apart. The direct tension capacity is Pt=AsptP_t=A_sp_t; the course’s simplified method (no separate prying calculation) uses Pnom=0.8AsptP_{nom}=0.8A_sp_t.

M20, Grade 8.8: Pt=245×5601,000=137.2kNPnom=0.8×137.2=109.76kN

The lecture clause also limits the bolt gauge on a flange to G≤0.55BG\le0.55B. The 0.8 factor is a simplification and does not prove that every flexible end plate is free of prying. If the question does not give enough dimensions, state “simplified method used”; you do not need to design the whole joint.

Animation labOut-of-plane bolt tension and prying1 concept · 4 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. A bracket moment can create compression at the plate contact and tension in the bolt rows.
  2. The original assumed pivot/compression line determines each row distance.
  3. Under the elastic row model, a farther tension row attracts more tension. Direct shear may act simultaneously.
  4. Flexible plates can add prying force. Use nominal tension and interaction rules exactly as specified by the course.

Gross, net and effective area Always examined

Simple explanation: Why holes reduce tension resistance

The pull must squeeze through the steel left beside the holes.

Why holes reduce tension resistance — The pull must squeeze through the steel left beside the holes.
Sketch, not to scale; use the original dimensions.
  1. Choose a possible fracture line across the member.
  2. Subtract the holes crossed by that line using hole diameter.
  3. Apply the course effective-area rule and its gross-area limit.

Remember: Do not subtract every hole anywhere in the connection.

Related concept and full method

Source: Chapter 2 pp.11–12.Gross area = the original plate area. Net area = the area left along a possible fracture line across the force, after deducting the holes. Effective area = Ke×K_e\times net area, but not more than the gross area.

Steel plate: Ag=bt;An=(b−nd0)t;Ae=min(KeAn,Ag)Ke=1.2 (S275) , 1.1 (S355) , 1.0 (S460) .

nn is the number of holes on one fracture line, not the total number of bolts. In a splice with two rows of bolts, a straight cross-section cuts only 2 holes, however many bolts there are along the length.

Chapter 2 p.12, Figures 9.7–9.8: straight and zigzag fracture paths and the developed gauge for angle legs.
Chapter 2 p.12, Figures 9.7–9.8. Figure 9.7 identifies the direction of force; D = hole diameter; t = plate thickness; an = net area; b = plate width. Upper-case S1 to S4 marks longitudinal stagger; g1 to g3 marks transverse gauge. The three path expressions in source order are:
① an=t(b−2D);
② an=t(b−3D+0.25S22g1);
③ an=t(b−4D+0.25S42g1+0.25S42g2+0.25S42g3).
Figure 9.8: heel means the angle root. The developed gauge across the two legs is g=g1+g2−t. All dimensions follow their source locations; do not estimate values from drawing scale.Open full-size image

(Less often examined.) With staggered holes compare straight and zig-zag fracture lines. Each diagonal step “adds back” s2t/4gs^2t/4g (ss = stagger along the force, gg = gauge across it): An=Ag−∑d0t+∑s2t/4gA_n=A_g-\sum d_0t+\sum s^2t/4g; take the smallest net area. For holes in both legs of an angle, the opened-out gauge is g=g1+g2−tg=g_1+g_2-t.

(Less often examined.) For a shear area with holes: if Av,net≥0.85Av/KeA_{v,\text{net}}\ge0.85A_v/K_e the holes can be ignored; otherwise use 0.7pyKeAv,net0.7p_yK_eA_{v,\text{net}}.

Connection example 2: design a bolted tension splice

Design a double-cover splice for an already ultimate tensile force of 700kN. Main plates are 150mm wide ×20mm thick; two S355 cover plates are 12mm thick. Use Grade 8.8 M20 bolts in 22mm holes, 50mm pitch and 40mm end distance.

Original source: LectureNotes/Ch 2_Connection.pdf — p. 18, p. 19, p. 20. Values tagged given are in the question or diagram; lookup values come from a named table; calculated values follow from the working; assumptions are stated explicitly.

Read the diagram and collect the data

InputOrigin
Given demand700kN ultimate; no further factor.
Given thicknessesMain t2=20mm; each cover t1=12mm; cross-section view labels each ply.
Given hole/pitch/endM20 → d=20; stated hole d0=22; longitudinal pitch 50; end 40mm.
Selected layoutp.19 drawing: two rows, gauge 90mm, side edges 30mm, two columns per half-splice.
LookupAs=245mm2, ps=375, pbb=1,000; S355 pbs=550, Us=510, Ke=1.1. Main py=345 for 20mm; covers py=355 for 12mm. All stress units Nmm2.

Before calculating: recognition and strategy

Each half-splice must transfer the full 700kN from a main plate into the covers. The covers each take half that force. Bolts have two shear planes; compare main thickness 20 with total cover thickness 24 for the bearing path. Select bolt count from the weakest per-bolt mode, round up, arrange the bolts, then check the plates cut by those holes.

1. Establish the capacity of one bolt and its bearing path

Simple explanation: Count where the bolt can be sheared

The plate interfaces are the places trying to cut across the bolt.

Count where the bolt can be sheared — The plate interfaces are the places trying to cut across the bolt.
Sketch, not to scale; use the original dimensions.
  1. Count actual loaded shear planes, not merely visible plates.
  2. Choose shank or threaded area for the plane concerned.
  3. Compare group resistance with the force that group transfers.

Remember: Bolts on opposite sides of a splice do not all act in parallel.

Related concept and full method

Double shear: Ps=2×375×2451,000=183.75kNtp=min(20,2×12)=20mmBolt bearing: Pbb=20×20×1,0001,000=400kNlc=pitch−hole diameter=50−22=28mmB1=1×20×20×5501,000=220kNB2=0.5×1×40×20×5501,000=220kNNet-clearance term between holes: 1.5×28×20×5101,000=428.4kNUpper cap: 2×20×20×8001,000=640kNConnected-plate resistance: min(220,220,428.4,640)=220kNGoverning resistance per bolt: min(183.75,400,220)=183.75kN

Using total cover thickness 24 is valid here because the two identical covers share the force symmetrically. An unequal cover arrangement would need separate load-sharing checks.

Animation labCount the bolt shear planes4 concepts · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. Load must cross an interface between the connected plates.
  2. A lap joint gives one shear plane through a bolt.
  3. A symmetric double-cover joint may provide two shear planes. Count load-transfer interfaces, not just visible plates.
  4. Use the source’s area and shear strength. Then check bearing, plate resistance and detailing separately.

2. Select bolts on each side of the splice

n≥700183.75=3.80952→ Select 4 bolts per half-joint. Resistance per half: 4×183.75=735kN>700kNDemand per bolt: 7004=175kN<183.75kN

Provide four on the left and four on the right: eight physical bolts in total. The eight do not jointly give “1,470kN” across the splice, because the left and right groups carry the same force in series.

Animation labCount the bolt shear planes1 concept · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. Load must cross an interface between the connected plates.
  2. A lap joint gives one shear plane through a bolt.
  3. A symmetric double-cover joint may provide two shear planes. Count load-transfer interfaces, not just visible plates.
  4. Use the source’s area and shear strength. Then check bearing, plate resistance and detailing separately.

3. Verify the selected layout

The two transverse rows are separated by 90mm. Width closure:30+90+30=150mm. Longitudinal pitch 50 and end 40 are the specified values. Use the source’s rolled-edge condition in Table 9.3, M20 row: minimum 26mm.

Minimum pitch: 2.5×20=50mm≤provided50Maximum pitch/gauge: min(12×12,150)=144mm50 and 90≤144. General minimum gauge: 3×20=60mm<90The minimum end/edge distance requirement is 26mm. The provided end and edge distances respectively satisfy 26mm<40mm26mm<30mmMaximum cover-plate edge distance: 11×12×275355=116.18mm>30Maximum main-plate edge distance: 11×20×275345=196.42mm>30
Animation labBolt centres, holes and edges1 concept · 3 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. Hole diameter d₀ differs from nominal bolt diameter d. Net-section deductions use the specified hole.
  2. Pitch runs along the load direction; gauge measures spacing across rows.
  3. End and edge distances start at the hole centre. The remaining ligament starts at the hole boundary.
  4. Minimum spacing, edge distances, grip and plate thickness come from the specified rules, not this scaled illustration.

4. Check main-plate tension across two holes

Simple explanation: Why holes reduce tension resistance

The pull must squeeze through the steel left beside the holes.

Why holes reduce tension resistance — The pull must squeeze through the steel left beside the holes.
Sketch, not to scale; use the original dimensions.
  1. Choose a possible fracture line across the member.
  2. Subtract the holes crossed by that line using hole diameter.
  3. Apply the course effective-area rule and its gross-area limit.

Remember: Do not subtract every hole anywhere in the connection.

Related concept and full method

The critical straight transverse line crosses one hole in each row: two 22mm holes. Do not deduct all four holes along a half-splice. Thickness 20mm selects py=345Nmm2.

Ag=150×20=3,000mm2An=(150−2×22)×20=106×20=2,120mm2Ae=min(1.1×2,120,3,000)=2,332mm2Pt=2,332×3451,000=804.54kN>700Passes.
Animation labSubtract holes on the failure path1 concept · 2 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. Gross area counts the complete plate width and thickness.
  2. The highlighted transverse path passes through the bolt holes.
  3. For the straight illustrative path, . Staggered paths require their specified correction.
  4. Net area is not always effective area. Include the course’s strength ratio or shear-lag rule when applicable.

5. Check both covers and conclude

Each cover plate: Ag=150×12=1,800mm2An=(150−44)×12=1,272mm2Ae=min(1.1×1,272,1,800)=1,399.2mm2Pt=1,399.2×3551,000=496.716kN>350kNBoth plates together: Pt=2×496.716=993.432kN>700kN

All requested checks pass under the stated rolled-edge layout. The least load-path resistance is bolt shear 735kN. The source gives approximately 993.2kN for covers after intermediate rounding; carrying full precision gives 993.43kN.

Animation labSubtract holes on the failure path2 concepts · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. Gross area counts the complete plate width and thickness.
  2. The highlighted transverse path passes through the bolt holes.
  3. For the straight illustrative path, . Staggered paths require their specified correction.
  4. Net area is not always effective area. Include the course’s strength ratio or shear-lag rule when applicable.

Compact exam answer

Four M20 Grade 8.8 bolts per side (eight total), two rows with 90mm gauge,50mm pitch,40mm ends and 30mm rolled edges. Double-shear resistance 735kN per half; bearing exceeds this. Main tension 804.54kN; combined cover tension 993.43kN. Each exceeds 700kN. Layout passes for the source’s rolled-edge assumption.

Mistakes to avoid

  • Do not factor the already ultimate 700kN.
  • Four bolts are required on each side of the plate butt.
  • Double shear doubles bolt shear, not the main-plate thickness.
  • A transverse net section crosses two holes, not four.

Procedure for an unfamiliar variant

  1. Trace one half-splice at full force and each cover at its share.
  2. Calculate per-bolt shear/bearing and take the minimum.
  3. Round up bolt count and draw a feasible layout.
  4. Check every pitch/edge rule using the thinner ply and correct edge finish.
  5. Check main and cover effective tension areas independently.

Independent self-check

Try it yourself. If the required ultimate force becomes 760kN but the splice is unchanged, which calculated resistance fails first?

Hint

Compare 760 with the complete group resistance, not just one bolt.

Reveal answer and reasoning

Bolt shear 735kN is inadequate. Main-plate tension 804.54kN and cover-pair tension 993.43kN still exceed 760. Adding bolts changes the layout and may change the fracture path, so repeat layout/net-area checks.

Animation labSubtract holes on the failure path1 concept · 7 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. Gross area counts the complete plate width and thickness.
  2. The highlighted transverse path passes through the bolt holes.
  3. For the straight illustrative path, . Staggered paths require their specified correction.
  4. Net area is not always effective area. Include the course’s strength ratio or shear-lag rule when applicable.

Block shear Background

Simple explanation: A whole block can pull out

Think of tearing a small tab out of a sheet along several connected edges.

A whole block can pull out — Think of tearing a small tab out of a sheet along several connected edges.
Sketch, not to scale; use the original dimensions.
  1. Trace the complete block around the bolt group.
  2. Separate edges sliding in shear from the edge pulled in tension.
  3. Deduct holes only where the applicable path crosses them.

Remember: One straight net-section check does not cover block shear.

Related concept and full method

Chapter 2 p.13, Figure 9.9: a block can tear along the longitudinal bolt line and across its transverse end.
Chapter 2 p.13, Figure 9.9: Block Shear and Effective Shear Area. In the figure, Ft is the applied tension; Lv is measured along the candidate shear plane; Lt is measured across the tensile plane. Cope identifies the beam-end notch. Arrows show the interaction between the block and the remaining member. Path directions differ with the detail; do not substitute the whole plate perimeter.Open full-size image

From the drawing: LvL_v is measured along the shear face and LtL_t along the tension face. Effective area Av,eff=t [Lv+Ke(Lt−kDt)]A_{v,\text{eff}}=t\,[L_v+K_e(L_t-kD_t)] and capacity Pr=0.6pyAv,effP_r=0.6p_yA_{v,\text{eff}}. DtD_t is the hole diameter on the tension face; k=0.5k=0.5 (one bolt row) or 2.5 (two rows). The lecture gives no full numerical example, and recent papers have not asked it.

Animation labSeparate the block-shear paths1 concept · 3 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. A block containing the connection can detach from the surrounding plate.
  2. The paths parallel to the applied force carry shear.
  3. The closing path across the end of the block carries tension.
  4. Use the specified gross/net deductions and resistance expression. This is different from a single straight net-section fracture.

Angles connected through one leg Always examined

Simple explanation: One connected leg does not load both legs equally

The connected leg receives the pull first; the other leg receives it through the angle.

One connected leg does not load both legs equally — The connected leg receives the pull first; the other leg receives it through the angle.
Sketch, not to scale; use the original dimensions.
  1. Identify connected and outstanding legs from the drawing.
  2. Use the relevant bolted or welded angle rule.
  3. Keep the lecturer’s area convention consistent.

Remember: Bolted and welded reduction expressions are not the same rule.

Related concept and full method

Source: Chapter 2 pp.14–15.a2a_2 = gross area of the outstanding (unconnected) leg; AeA_e = sum of the effective leg areas. The two legs overlap at the corner, so do not count it twice: the lecture gives half the thickness to each leg, i.e. connected leg (A−t/2) t(A-t/2)\,t and outstanding leg (B−t/2) t(B-t/2)\,t.

ConnectionCapacity
Single angle, boltedPt=py(Ae−0.5a2)
Single angle, weldedPt=py(Ae−0.3a2)
Double angles on both sides of gusset, interconnected, boltedPt=py(Ae−0.25a2)
Same double-angle arrangement, weldedPt=py(Ae−0.15a2)

Two angles: either use the total area of both at once, or work out one angle (with half the force) and double it — but never use the total area and then double again. The deductions in the table already allow for the connection eccentricity, so do not add a moment.

Concept map: Net area and angles connected through one leg: why tension cannot use the whole area

Concept map

Net area and angles connected through one leg: why tension cannot use the whole area

Every recent connection question has 7 marks on angle tension in part (a). Two things shrink the usable area: holes remove steel, and when only one leg is connected the other cannot carry its full share. The two routes meet at PtP_t.

Text version (from cause to result)

  1. Cause

    Tension through a plate with holes

    Bolt holes remove part of the plate, so the pull has to squeeze past them.

  2. Cause

    An angle connected through one leg

    The bolts (or welds) hold only one leg (the connected leg); the other leg sticks out (the outstanding leg).

  3. Key ideaWhere marks are lost

    AnA_n Net area: deduct holes on one fracture line

    Along one fracture line across the force, deduct the holes it cuts: An=(b−n d0) tA_n=(b-n\,d_0)\,t.

    Deduct only the holes on this fracture line
  4. What changes it

    d0d_0 Use the hole, not the bolt

    The hole is bigger than the bolt (M20 → 22 mm). Net area deducts the hole d0d_0; only bearing uses the bolt diameter dd.

    Bolt d, hole d₀
  5. Key idea

    The outstanding leg joins in late

    The pull enters the connected leg first and reaches the outstanding leg only through the corner, so the outstanding leg cannot work fully. This is the idea of shear lag.

    The two legs pick up load differently
  6. What changes it

    a1a_1, a2a_2 Share the corner between the legs

    The legs overlap at the corner, so do not count it twice: connected leg a1=(A−t/2) ta_1=(A-t/2)\,t, outstanding leg a2=(B−t/2) ta_2=(B-t/2)\,t.

  7. How design deals with itWhere marks are lost

    AeA_e Effective area: × K_e, but not above the gross area

    The holes affect only a short length, where the steel breaks at its tensile strength UsU_s rather than at yield, so the course lets the net area be multiplied by KeK_e. The stronger the steel, the closer UsU_s is to pyp_y and the smaller KeK_e: S275 → 1.2, S355 → 1.1, S460 → 1.0.

    Formula

    Ae=min⁡(KeAn,  Ag)A_e=\min(K_eA_n,\;A_g)
  8. How design deals with itWhere marks are lost

    k a2k\,a_2 Deduct k·a₂ for the outstanding leg

    Single angle: bolted 0.5, welded 0.3; double angles (both sides of a gusset): bolted 0.25, welded 0.15. The deductions already allow for the connection eccentricity, so add no moment.

  9. Result

    PtP_t Angle tension capacity

    Effective connected leg plus the outstanding leg, minus k a2k\,a_2, times pyp_y. Worked numbers: bolt calculation map.

    Formula

    Pt=py (Ae−k a2)1000P_t=\frac{p_y\,(A_e-k\,a_2)}{1000}
  10. Exam answer

    Exam: write every area on its own line

    Write a1,a2,an1,ae1,Aea_1,a_2,a_{n1},a_{e1},A_e and PtP_t; each line earns marks. Two angles: use the total area once, or one angle (half the force) and double it — never both.

Tour steps

  1. 1. Holes make the section smaller

    Deduct the holes on one fracture line, using the hole diameter d0d_0.

  2. 2. Effective area

    Ae=min⁡(KeAn, Ag)A_e=\min(K_eA_n,\,A_g).

  3. 3. An angle connected through one leg

    The pull enters the connected leg first and the other leg lags; the corner is shared between the legs.

  4. 4. Deduct k a2k\,a_2

    Single angle 0.5 / 0.3, double angles 0.25 / 0.15 (bolted / welded).

  5. 5. The two routes meet

    Pt=py(Ae−k a2)P_t=p_y(A_e-k\,a_2), with every area on its own line.

Connection example 1: single bolted unequal angle

Check a single S355 80×60×8mm angle connected through its long leg to a 10mm plate by the stated two Grade 8.8 M20 bolts. Dead tension is 75kN; imposed tension is 40kN. Check bolt shear, bolt/plate bearing and angle tension.

Original source: LectureNotes/Ch 2_Connection.pdf — p. 16, p. 17. Values tagged given are in the question or diagram; lookup values come from a named table; calculated values follow from the working; assumptions are stated explicitly.

Read the diagram and collect the data

InputValue and exact source
Given loads75kN dead and 40kN imposed, question text; the downward arrow is the resulting tension direction.
Given geometryLong leg 80mm; short leg 60mm; t=8mm. The split dimensions 76 and 56 allocate half the heel thickness to each leg.
Given fastenersText specifies TWO M20 Grade 8.8 bolts; standard 22mm holes; 50mm pitch; 45mm end distance.
Given plate/model10mm supporting plate; one shear plane explicitly stated.
LookupCh 2 p.3 M20 tensile stress area As=245mm2. Ch 2 pp.9–10 Grade 8.8: ps=375, pbb=1,000, Ub=800Nmm2. S355: pbs=550, Us=510, Ke=1.1. Data File p.1, thickness ≤16mm: py=355.

Before calculating: recognition and strategy

This is concentric tension through one connected angle leg. The load crosses the angle-to-plate interface as bolt shear, presses on holes as bearing, and remains tension in the angle. Start with the factored force. Check each fastener mode, then the reduced angle tension resistance. Prerequisites: stress×area gives force; “net area” removes holes; a single-leg connection needs the specific unconnected-leg reduction.

1. Convert characteristic loads to one design force

P is the ULS tensile demand in kN. Apply the course gravity factors once; the supplied loads are characteristic, not already ultimate.

P=1.4G+1.6Q=1.4×75+1.6×40=105+64=169kNLoad demand per bolt: Pn=1692=84.5kN
Animation labFrom characteristic to design load1 concept · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. G is permanent load; Q is imposed load. A surface load and a line load also have different units.
  2. This illustration uses the course gravity case . Other combinations in the original text retain their own factors.
  3. For illustrative , change Q and watch each separate contribution.
  4. Do not carry this ULS total automatically into deflection. Follow the stated SLS load case.

2. Bolt shear across the single interface

Simple explanation: Count where the bolt can be sheared

The plate interfaces are the places trying to cut across the bolt.

Count where the bolt can be sheared — The plate interfaces are the places trying to cut across the bolt.
Sketch, not to scale; use the original dimensions.
  1. Count actual loaded shear planes, not merely visible plates.
  2. Choose shank or threaded area for the plane concerned.
  3. Compare group resistance with the force that group transfers.

Remember: Bolts on opposite sides of a splice do not all act in parallel.

Related concept and full method

As is the tensile stress area because no thread-free shear plane is guaranteed. There is one interface between the angle leg and the support plate, so no factor 2 for double shear.

Ps,one=psAs1,000=375Nmm2×245mm21,000=91.875kNPs,group=2×91.875=183.750kN>169kNPasses.
Animation labCount the bolt shear planes1 concept · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. Load must cross an interface between the connected plates.
  2. A lap joint gives one shear plane through a bolt.
  3. A symmetric double-cover joint may provide two shear planes. Count load-transfer interfaces, not just visible plates.
  4. Use the source’s area and shear strength. Then check bearing, plate resistance and detailing separately.

3. Bearing of the bolts

Simple explanation: The bolt can crush or tear the plate

A strong bolt can still push through a weak hole edge.

The bolt can crush or tear the plate — A strong bolt can still push through a weak hole edge.
Sketch, not to scale; use the original dimensions.
  1. Check the bolt and each connected plate’s bearing bounds.
  2. Use nominal bolt diameter for bearing; hole size for removed material.
  3. The smallest applicable resistance controls.

Remember: A short end distance may govern even when bolt shear passes.

Related concept and full method

Use the thinner connected thickness tp=min(8,10)=8mm: the angle leg governs. d=20mm is the bolt diameter, not the 22mm hole.

Pbb,one=dtppbb1,000=20×8×1,0001,000=160kNBolt-group resistance: 2×160=320kN>169kNPasses.
Animation labBearing and the remaining ligament1 concept · 3 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. Force transfers through contact between bolt and connected plate.
  2. The plate around the hole carries bearing stress. Bolt bearing and plate bearing are separate checks.
  3. A short ligament can tear out towards the end. The direction of force determines the relevant edge.
  4. Evaluate every specified bearing and ligament bound for each layer and retain the smallest applicable resistance.

4. Bearing and ligament resistance of the angle leg

The 50mm dimension is centre-to-centre pitch along tension. Subtract one full hole diameter to get the clear inter-hole ligament lc. The 45mm dimension is end distance from end to nearest bolt centre.

lc=50−22=28mm;e=45mm;kbs=1B1=1×20×8×5501,000=88kNB2=0.5×1×45×8×5501,000=99kNNet-clearance term between holes: 1.5×28×8×5101,000=171.36kNUpper cap: 2×20×8×8001,000=256kNB3=min(171.36,256)=171.36kNPbs,one=min(88,99,171.36)=88kNTwo bolts together: 2×88=176kN>169kNPasses.

Plate bearing is closer to its limit than bolt shear: 169176=0.9602 utilisation. This is why the larger bolt-bearing value 320kN cannot be used as the joint’s governing resistance.

Animation labBearing and the remaining ligament1 concept · 2 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. Force transfers through contact between bolt and connected plate.
  2. The plate around the hole carries bearing stress. Bolt bearing and plate bearing are separate checks.
  3. A short ligament can tear out towards the end. The direction of force determines the relevant edge.
  4. Evaluate every specified bearing and ligament bound for each layer and retain the smallest applicable resistance.

5. Effective angle area and single-leg reduction

Simple explanation: One connected leg does not load both legs equally

The connected leg receives the pull first; the other leg receives it through the angle.

One connected leg does not load both legs equally — The connected leg receives the pull first; the other leg receives it through the angle.
Sketch, not to scale; use the original dimensions.
  1. Identify connected and outstanding legs from the drawing.
  2. Use the relevant bolted or welded angle rule.
  3. Keep the lecturer’s area convention consistent.

Remember: Bolted and welded reduction expressions are not the same rule.

Related concept and full method

Use the lecturer’s rectangular leg-area approximation. The heel is shared: connected leg width 80−82=76mm; unconnected width 60−82=56mm. A transverse fracture line crosses one hole, not both bolts arranged along the member. Apply Ke separately to each leg and cap each at its own gross area.

ag1=76×8=608mm2;a2=ag2=56×8=448mm2Ag=608+448=1,056mm2an1=(76−22)×8=54×8=432mm2an2=448mm2The outstanding angle leg has no hole.ae1=min(1.1×432,608)=475.2mm2ae2=min(1.1×448,448)=min(492.8,448)=448mm2Ae=475.2+448=923.2mm2Pt=py(Ae−0.5a2)1,000=355×(923.2−0.5×448)1,000=355×699.21,000=248.216kN>169kNPasses.

The factor 0.5 belongs specifically to a single bolted angle connected through one leg (Ch 2 p.14). It is not a generic reduction for all tension members.

Animation labWhy a connected angle leg matters1 concept · 3 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. Locate the connected leg, outstanding leg and centroid before using the table.
  2. Only the connected leg directly receives the fastener force.
  3. The outstanding area may not become equally effective at the same section; this motivates the effective-area rule.
  4. Bolted, welded, single-angle and double-angle details can have different rules. Preserve the formula attached to the original case.

6. State the governing result and the scope

For the requested resistance checks, the minimum is plate bearing 176kN, above 169kN. The angle tension check also passes. Units close correctly: stress×mm2 gives N before dividing by 1,000.

The pitch 50mm equals 2.5×20=50mm and is less than min(12×8,150)=96mm. The end distance 45mm exceeds both supplied M20 minimum values (34 or 26mm). The transverse edge distances are not fully dimensioned in this example, so these observations do not prove that the entire arrangement has been verified.

Animation labFollow the calculation sequence5 concepts · 2 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. Locate the load, supports, connection geometry and any stated assumptions.
  2. Keep given values, table lookups and calculated values distinct; reconcile their units.
  3. The calculation player steps through the existing expressions in their original order.
  4. Compare demand with resistance or the relevant limit. Keep missing inputs and conditional conclusions explicit.

Compact exam answer

P=169kN. Two bolts in single shear: Ps=183.75kN; bolt bearing =320kN; angle bearing =min(176,198,342.72)=176kN. Ae=923.2mm2; single angle Pt=355(923.2−0.5×448)1,000=248.22kN. All required resistances exceed the demand. Plate bearing governs, using the two-bolt model specified by the question.

Mistakes to avoid

  • Do not multiply by two for shear planes; the given joint is single shear.
  • Subtract 22mm for a hole, use 20mm for bearing.
  • Do not multiply the unconnected gross leg area by 1.1 without its gross-area cap.
  • Do not silently replace the written two bolts with four based on the inconsistent sketch.

Procedure for an unfamiliar variant

  1. Read the written bolt count and the interface geometry; reconcile any discrepancy.
  2. Factor characteristic loads and distribute concentric load to the bolts.
  3. Check shear, bolt bearing and all connected-part bounds.
  4. Compute gross/net/effective leg areas and the correct single/double connection reduction.
  5. Compare each complete load path with the same demand and name the governing one.

Independent self-check

Try it yourself. Keep the geometry but increase imposed load to 50kN. Does the connection still pass the calculated strength checks?

Hint

Recalculate demand only; the capacities do not change when geometry and materials stay the same.

Reveal answer and reasoning

New P=1.4×75+1.6×50=185kN. Plate bearing 176kN and bolt shear 183.75kN are both inadequate; angle tension still passes. A stronger angle alone would not fix the fastener path.

Animation labCount the bolt shear planes4 concepts · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. Load must cross an interface between the connected plates.
  2. A lap joint gives one shear plane through a bolt.
  3. A symmetric double-cover joint may provide two shear planes. Count load-transfer interfaces, not just visible plates.
  4. Use the source’s area and shear strength. Then check bearing, plate resistance and detailing separately.
Animation labWhy a connected angle leg matters2 concepts · 5 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. Locate the connected leg, outstanding leg and centroid before using the table.
  2. Only the connected leg directly receives the fastener force.
  3. The outstanding area may not become equally effective at the same section; this motivates the effective-area rule.
  4. Bolted, welded, single-angle and double-angle details can have different rules. Preserve the formula attached to the original case.

Eccentric bolt group (in the plane of the plate) Often examined

Simple explanation: An off-centre force also tries to turn the group

Pulling away from the centre causes a push plus a twist.

An off-centre force also tries to turn the group — Pulling away from the centre causes a push plus a twist.
Sketch, not to scale; use the original dimensions.
  1. Find direct shear and moment about the bolt-group centroid.
  2. Moment-induced forces act tangentially; farther bolts attract more.
  3. Add horizontal and vertical components before finding the resultant.

Remember: Do not simply add two force magnitudes pointing in different directions.

Related concept and full method

Source: Chapter 2 pp.21–22.Assumptions: the plate is rigid, all bolts are equal, the twisting force is proportional to the distance from the centre, and direct shear is shared equally. Put the origin at the group centroid; each bolt has coordinates xi,yix_i,y_i (mm) and ri2=xi2+yi2r_i^2=x_i^2+y_i^2.

Jbolts=Σri2=Σxi2+Σyi2Units: mm2. M=PeUnits: kN·mm. FT,i=MriJbolts;Fs=PnBoth have units kN.

Why: each bolt’s twisting force is C riC\,r_i and its resisting moment C ri2C\,r_i^2; adding them up gives MM, so C=M/JC=M/J. The twisting force is perpendicular to the radius (along the circle). For a vertical load, a corner bolt has vertical part Mx/JMx/J and horizontal part My/JMy/J. Choose the corner where the vertical part adds to the direct shear.

FR=(Pn+M|x|J)2+(M|y|J)2

This is exactly the lecture’s vector formula Fs2+FT2+2FsFTcos⁡φ\sqrt{F_s^2+F_T^2+2F_sF_T\cos\varphi} (for a vertical load cos⁡φ=∣x∣/r\cos\varphi=|x|/r). Using the components above is less error-prone.

Connection example 3: an eccentric bolt group in the plate plane

Check the Grade 8.8 M24 bolt group carrying 100kN dead plus 130kN imposed load at a 525mm eccentricity. Steel is S355. Use the lecturer’s one-side-plate load model.

Original source: LectureNotes/Ch 2_Connection.pdf — p. 25, p. 26. Values tagged given are in the question or diagram; lookup values come from a named table; calculated values follow from the working; assumptions are stated explicitly.

Read the diagram and collect the data

InputOrigin
Given load/model100kN dead+130kN imposed. Drawing says bolt loads shown on one plate; do not halve the specified force again.
Given e525mm horizontal distance from the dashed bolt-group centreline to vertical load line, upper dimension.
Coordinatesx=±250mm from the two 250 dimensions. y=±35,±105,±175mm from 70mm pitch and symmetric six-row arrangement.
Thickness and edgeSide plate 15mm; p.26 gives UC flange 17.3mm, so tp=15. Vertical end 45mm; pitch 70; hole 26mm.
LookupM24 As=353mm2; ps=375,pbb=1,000,pbs=550,Us=510,Ub=800Nmm2.

Before calculating: recognition and strategy

The load rotates the plate in its own plane, so each bolt takes uniform direct shear plus tangential torsional shear. This is not a bolt-tension problem. Use centroidal coordinates, sum squared distances over all 12 bolts, and resolve torsional force into components before adding direct shear. The far right corners have torsional vertical force in the same direction as direct shear.

1. Factored load and moment

P=1.4×100+1.6×130=140+208=348kNM=Pe=348kN×525mm=182,700kN·mm=182.7kN·m
Animation labFrom characteristic to design load2 concepts · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. G is permanent load; Q is imposed load. A surface load and a line load also have different units.
  2. This illustration uses the course gravity case . Other combinations in the original text retain their own factors.
  3. For illustrative , change Q and watch each separate contribution.
  4. Do not carry this ULS total automatically into deflection. Follow the stated SLS load case.

2. Bolt-group polar sum and corner radius

Simple explanation: An off-centre force also tries to turn the group

Pulling away from the centre causes a push plus a twist.

An off-centre force also tries to turn the group — Pulling away from the centre causes a push plus a twist.
Sketch, not to scale; use the original dimensions.
  1. Find direct shear and moment about the bolt-group centroid.
  2. Moment-induced forces act tangentially; farther bolts attract more.
  3. Add horizontal and vertical components before finding the resultant.

Remember: Do not simply add two force magnitudes pointing in different directions.

Related concept and full method

Each bolt contributes x2+y2. There are 12 identical |x| values. At each absolute height 35, 105, 175mm there are four bolts: two left/right positions multiplied by two positive/negative vertical positions.

Σx2=12×2502=12×62,500=750,000mm2Σy2=4(352+1052+1752)=4(1,225+11,025+30,625)=171,500mm2J=750,000+171,500=921,500mm2rA=2502+1752=93,125=305.164mmcosφ=250305.164=0.819232
Animation labAdd direct and torsional bolt forces1 concept · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. Assign signed coordinates to the bolts relative to the group centroid.
  2. For the equal-bolt elastic model, the direct force is per bolt.
  3. Moment magnitude is ; its sign follows the load direction. For signed M: , , .
  4. Add signed x and y components at each bolt, then take the resultant. The longest arrow shows the critical bolt in this illustration.

3. Direct force, torsion and maximum resultant

Simple explanation: Add arrows before taking the magnitude

Walking east and walking north do not point in the same direction.

Add arrows before taking the magnitude — Walking east and walking north do not point in the same direction.
Sketch, not to scale; use the original dimensions.
  1. Choose signed horizontal and vertical directions.
  2. Add contributions along each direction separately.
  3. For perpendicular components, use the right-triangle resultant.

Remember: Check the corner where direct and torsional components reinforce each other.

Related concept and full method

Direct shear per bolt: Fs=P12=34812=29kNFT,A=MrJ=182,700×305.164921,500=60.503kNVertical torsional-force component: M×250J=49.566kNHorizontal torsional-force component: M×175J=34.696kNFR,A=(29+49.566)2+34.6962=85.886kN

The units of MrJ are (kN·mm)×mmmm2=kN. The top/bottom right corners have equal resultant magnitude. Other rows have a smaller horizontal torsion component; the left column’s vertical torsion subtracts from direct shear, so it is less critical.

Animation labAdd direct and torsional bolt forces1 concept · 2 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. Assign signed coordinates to the bolts relative to the group centroid.
  2. For the equal-bolt elastic model, the direct force is per bolt.
  3. Moment magnitude is ; its sign follows the load direction. For signed M: , , .
  4. Add signed x and y components at each bolt, then take the resultant. The longest arrow shows the critical bolt in this illustration.

4. Compare with single-shear bolt resistance

Ps=375×3531,000=132.375kN>85.886kNPasses.

The source checks the side plate’s single shear interface. The plan view showing plates on both sides does not authorise doubling resistance while keeping only one side’s force model.

Animation labCount the bolt shear planes1 concept · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. Load must cross an interface between the connected plates.
  2. A lap joint gives one shear plane through a bolt.
  3. A symmetric double-cover joint may provide two shear planes. Count load-transfer interfaces, not just visible plates.
  4. Use the source’s area and shear strength. Then check bearing, plate resistance and detailing separately.

5. Check bolt bearing against the same resultant

tp=min(15,17.3)=15mmPbb=24×15×1,0001,000=360kN>85.886kNPasses.
Animation labBearing and the remaining ligament1 concept · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. Force transfers through contact between bolt and connected plate.
  2. The plate around the hole carries bearing stress. Bolt bearing and plate bearing are separate checks.
  3. A short ligament can tear out towards the end. The direction of force determines the relevant edge.
  4. Evaluate every specified bearing and ligament bound for each layer and retain the smallest applicable resistance.

6. Connected-part bounds and conclusion

Simple explanation: The bolt can crush or tear the plate

A strong bolt can still push through a weak hole edge.

The bolt can crush or tear the plate — A strong bolt can still push through a weak hole edge.
Sketch, not to scale; use the original dimensions.
  1. Check the bolt and each connected plate’s bearing bounds.
  2. Use nominal bolt diameter for bearing; hole size for removed material.
  3. The smallest applicable resistance controls.

Remember: A short end distance may govern even when bolt shear passes.

Related concept and full method

lc=70−26=44mmB1=1×24×15×5501,000=198kNB2=0.5×1×45×15×5501,000=185.625kNNet-clearance term between holes: 1.5×44×15×5101,000=504.9kNUpper cap: 2×24×15×8001,000=576kNPbs=min(198,185.625,504.9,576)=185.625kN>85.886Passes.

For the course’s specified connection checks, single-shear bolt capacity 132.375kN is the governing resistance per critical bolt. The ratio 85.886132.375≈0.649. This is not a total connection force capacity of 132.375kN: it is compared with the critical bolt force.

Animation labBearing and the remaining ligament2 concepts · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. Force transfers through contact between bolt and connected plate.
  2. The plate around the hole carries bearing stress. Bolt bearing and plate bearing are separate checks.
  3. A short ligament can tear out towards the end. The direction of force determines the relevant edge.
  4. Evaluate every specified bearing and ligament bound for each layer and retain the smallest applicable resistance.

Compact exam answer

P=348kN, M=182.7kN·m. J=921,500mm2; r=305.164mm. Fs=29kN, FT=60.503kN; FR,max=85.886kN. Per-bolt resistances: shear 132.375kN, bolt bearing 360kN, plate bearing 185.625kN. All exceed the resultant; requested checks pass.

Mistakes to avoid

  • Do not use P12 as the complete bolt demand.
  • The sum for bolt-group geometry has units mm2, unlike weld line inertia mm3.
  • The 525mm eccentricity starts at the group centroid, not the right bolt column.
  • Add force components; Fs+FT is not the actual resultant.

Procedure for an unfamiliar variant

  1. Locate centroid and write every bolt coordinate.
  2. Compute factored P, centroidal eccentricity e and M.
  3. Sum all r2 and resolve MrJ into components.
  4. Find the corner where torsion adds to direct shear.
  5. Compare that resultant with shear and all bearing limits.

Independent self-check

Try it yourself. If both characteristic loads increase by 20% with unchanged geometry, how does the critical bolt force change?

Reveal answer and reasoning

P and M each multiply by 1.2; every direct/torsional component does too. FR=1.2×85.886=103.063kN, still below 132.375kN. Capacity is unchanged.

Animation labAdd direct and torsional bolt forces1 concept · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. Assign signed coordinates to the bolts relative to the group centroid.
  2. For the equal-bolt elastic model, the direct force is per bolt.
  3. Moment magnitude is ; its sign follows the load direction. For signed M: , , .
  4. Add signed x and y components at each bolt, then take the resultant. The longest arrow shows the critical bolt in this illustration.
Animation labAdd direct and torsional bolt forces1 concept · 6 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. Assign signed coordinates to the bolts relative to the group centroid.
  2. For the equal-bolt elastic model, the direct force is per bolt.
  3. Moment magnitude is ; its sign follows the load direction. For signed M: , , .
  4. Add signed x and y components at each bolt, then take the resultant. The longest arrow shows the critical bolt in this illustration.

Bracket bolts: shear and tension together Often examined

Simple explanation: Two passing checks may still interact

One bolt is doing two jobs at the same time.

Two passing checks may still interact — One bolt is doing two jobs at the same time.
Sketch, not to scale; use the original dimensions.
  1. Check shear on its own and tension on its own.
  2. Calculate the course’s combined-action expression.
  3. Apply its own limit, not a limit borrowed from columns.

Remember: The supplied bolt interaction limit of 1.4 does not replace the individual checks.

Related concept and full method

Source: Chapter 2 pp.23–24.The lecture assumes the bracket pivots about the bottom contact (bolt) line. Measure each row’s yy from that line, so the bottom row has y=0y=0 and no tension, but it still shares the shear.

Jrows=Σ(distances of all boltsy2)Units: mm2. FT,max=PeymaxJrowsFs=PnCheck simultaneously: Fs≤Ps;FT,max≤PnomFsPs+FT,maxPnom≤1.4

Two identical columns of bolts: ∑y2\sum y^2 must include both (= twice one column), but do not multiply by 2 again if you already did. All three conditions must hold: shear ≤ PsP_s, tension ≤ PnomP_{nom}, interaction ≤ 1.4. Check bearing too when the data allow.

Concept map: Bracket bolts: why the top row is pulled hardest

Concept map

Bracket bolts: why the top row is pulled hardest

A bracket sticks out from its support and the load tries to peel it off. The bolts do two jobs at once: all of them share the shear, and the upper rows also resist tension. The two routes meet in three checks — and the limit is 1.4, not 1.

Text version (from cause to result)

  1. Cause

    PP, ee A load at distance e from the face

    The load PP acts a distance ee out from the face where the bolts are.

  2. Key idea

    M=P eM=P\,e The moment peels the bracket off

    The load times its lever arm ee gives a moment that tries to pull the top of the bracket away from the face.

  3. Key ideaWhere marks are lost

    It pivots about the bottom row

    The lecture assumes the bracket pivots about the bottom contact (bolt) line, so each row’s yy is measured from it; the bottom row has y=0y=0 and no tension.

    The further from the pivot line, the bigger the pull
  4. What changes itWhere marks are lost

    ∑y2\textstyle\sum y^2 How well the group resists peeling

    Bolts further from the pivot are more effective, measured by ∑y2\sum y^2. With two identical columns of bolts, include both.

  5. Result

    FtF_t Tension grows with distance: top row hardest

    Each bolt’s tension is proportional to its distance from the pivot, so the top row (ymax⁡y_{\max}) is pulled hardest.

    Formula

    Ft=P e ymax⁡∑y2F_t=\frac{P\,e\,y_{\max}}{\sum y^2}
  6. Result

    FsF_s Shear shared equally

    Every bolt shares the vertical shear equally — including the bottom row, which has no tension but still takes shear.

    Formula

    Fs=PnF_s=\frac{P}{n}
  7. What changes it

    PsP_s, PnomP_{nom} Capacity of each bolt

    Shear Ps=psAsP_s=p_sA_s; tension Pnom=0.8AsptP_{nom}=0.8A_sp_t. M20 Grade 8.8: 91.875 kN and 109.76 kN.

  8. How design deals with itWhere marks are lost

    All three must hold; the limit is 1.4

    Fs≤PsF_s\le P_s; Ft≤PnomF_t\le P_{nom}; Fs/Ps+Ft/Pnom≤1.4F_s/P_s+F_t/P_{nom}\le1.4. Check bearing too when the data allow.

    Individual checks + combined check
  9. Exam answer

    Exam: all three conclusions

    2023 PTE: Ft=100<109.76F_t=100<109.76, Fs=35<91.875F_s=35<91.875, 0.381+0.911=1.292<1.40.381+0.911=1.292<1.4 ✓. Solution

Tour steps

  1. 1. The load peels the bracket

    The load sits ee from the face, giving a moment PePe.

  2. 2. Pivot about the bottom row

    yy is measured from the bottom row; ∑y2\sum y^2 measures how well the group resists.

  3. 3. Two kinds of force

    Tension comes from the moment and is largest at the top; shear is shared equally by all.

  4. 4. Three checks

    Shear and tension separately, then the interaction ≤ 1.4.

Connection example 4: bracket bolts in shear and tension

Check ten Grade 8.8 M16 bolts supporting a 250kN ultimate bracket load at 200mm eccentricity. Five bolts are arranged vertically on each side at 90mm centres. Steel is S355.

Original source: LectureNotes/Ch 2_Connection.pdf — p. 27, p. 28. Values tagged given are in the question or diagram; lookup values come from a named table; calculated values follow from the working; assumptions are stated explicitly.

Read the diagram and collect the data

InputOrigin
Given load250kN ultimate; the downward arrow is outside the connection plane.
Given bolt arrangementFive bolts per side; two sides;90mm between consecutive rows; total 10.
Calculated row distancesOn each side, measure upwards from the bottom rotation line: 0,90,180,270,360mm.
LookupM16 As=157mm2, Grade 8.8 ps=375 and pt=560Nmm2 (Ch 2 pp.3,9–10).
Model assumptionRigid bracket and linear tensile-force distribution about bottom bolt line, as stated in the lecturer approximation; use nominal tension 0.8Aspt.

Before calculating: recognition and strategy

The load pulls the upper bolts along their axes while all bolts carry vertical shear. Use an out-of-plane rotation model, not the centroidal in-plane torsion formula. Check shear, tension and their interaction separately. The task’s bolt calculation does not provide the full plate/gauge dimensions needed for a complete joint/prying and bearing verification.

1. Find bolt shear and nominal tension resistance

Ps=375×1571,000=58.875kNPt=560×1571,000=87.92kNPnom=0.8×87.92=70.336kN

The 0.8 reduction is part of the adopted simplified model. Do not substitute 87.92 in the nominal-tension interaction denominator.

Animation labOut-of-plane bolt tension and prying2 concepts · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. A bracket moment can create compression at the plate contact and tension in the bolt rows.
  2. The original assumed pivot/compression line determines each row distance.
  3. Under the elastic row model, a farther tension row attracts more tension. Direct shear may act simultaneously.
  4. Flexible plates can add prying force. Use nominal tension and interaction rules exactly as specified by the course.

2. Sum squared distances about the bottom row

Each of the two vertical sides has the same distances. The bottom row contributes 02 to moment resistance but remains in the count for direct shear.

Jrows=2(02+902+1802+2702+3602)=2(0+8,100+32,400+72,900+129,600)=2×243,000=486,000mm2M=Pe=250×200=50,000kN·mm
Animation labOut-of-plane bolt tension and prying1 concept · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. A bracket moment can create compression at the plate contact and tension in the bolt rows.
  2. The original assumed pivot/compression line determines each row distance.
  3. Under the elastic row model, a farther tension row attracts more tension. Direct shear may act simultaneously.
  4. Flexible plates can add prying force. Use nominal tension and interaction rules exactly as specified by the course.

3. Maximum tension is in the top row

Simple explanation: Why the top bolt row is pulled hardest

The bracket tries to peel away from the support about the assumed contact line.

Why the top bolt row is pulled hardest — The bracket tries to peel away from the support about the assumed contact line.
Sketch, not to scale; use the original dimensions.
  1. Use the rotation/contact line assumed by the course model.
  2. Measure each bolt row’s distance from that line.
  3. Check maximum tension, direct shear and their interaction.

Remember: A row at the pivot can still carry direct shear.

Related concept and full method

Tension varies in proportion to distance y. Let Fi=Cyi; moment equilibrium gives M=CΣy2. Thus C=MJ and the top bolt at y=360mm has the largest tension.

FT,max=50,000×360486,000=37.037kN37.037<70.336kN: individual tension check passes.
Animation labOut-of-plane bolt tension and prying1 concept · 5 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. A bracket moment can create compression at the plate contact and tension in the bolt rows.
  2. The original assumed pivot/compression line determines each row distance.
  3. Under the elastic row model, a farther tension row attracts more tension. Direct shear may act simultaneously.
  4. Flexible plates can add prying force. Use nominal tension and interaction rules exactly as specified by the course.

4. Uniform direct shear

Fs=Pn=25010=25kN25<58.875kN: individual shear check passes.
Animation labCount the bolt shear planes1 concept · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. Load must cross an interface between the connected plates.
  2. A lap joint gives one shear plane through a bolt.
  3. A symmetric double-cover joint may provide two shear planes. Count load-transfer interfaces, not just visible plates.
  4. Use the source’s area and shear strength. Then check bearing, plate resistance and detailing separately.

5. Combined action and conclusion

Simple explanation: Two passing checks may still interact

One bolt is doing two jobs at the same time.

Two passing checks may still interact — One bolt is doing two jobs at the same time.
Sketch, not to scale; use the original dimensions.
  1. Check shear on its own and tension on its own.
  2. Calculate the course’s combined-action expression.
  3. Apply its own limit, not a limit borrowed from columns.

Remember: The supplied bolt interaction limit of 1.4 does not replace the individual checks.

Related concept and full method

FsPs+FTPnom=2558.875+37.03770.336=0.424628+0.526573=0.951201≤1.4Passes.

The bolts satisfy all three calculated shear/tension conditions under the lecturer’s approximate model. This is the requested bolt result. Plate thickness, detailed bearing-edge geometry and flange gauge are not supplied sufficiently to certify every other joint limit state; do not claim those have been checked.

Animation labOut-of-plane bolt tension and prying2 concepts · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. A bracket moment can create compression at the plate contact and tension in the bolt rows.
  2. The original assumed pivot/compression line determines each row distance.
  3. Under the elastic row model, a farther tension row attracts more tension. Direct shear may act simultaneously.
  4. Flexible plates can add prying force. Use nominal tension and interaction rules exactly as specified by the course.

Compact exam answer

Ps=58.875kN; Pnom=70.336kN. Σy2=486,000mm2 about bottom bolt line. FT,max=250×200×360486,000=37.037kN. Fs=25kN. Individual limits pass and interaction=0.9512<1.4. Bolts are adequate under the specified approximate shear/tension model.

Mistakes to avoid

  • Do not factor 250kN again.
  • Do not measure y from the group centroid for this bottom-pivot model.
  • Do not omit the bottom bolts from direct shear.
  • Passing the 1.4 interaction does not replace individual shear/tension limits.

Procedure for an unfamiliar variant

  1. Identify out-of-plane rotation and the stated pivot.
  2. Write all y distances and include all physical bolts in Σy2.
  3. Calculate maximum tension and uniform shear.
  4. Check each individual resistance and then the interaction.
  5. State the model and any unprovided plate/prying information.

Independent self-check

Try it yourself. Move the same load to 400mm eccentricity. Does the existing bolt group pass?

Reveal answer and reasoning

Tension doubles to 74.074kN, exceeding 70.336. Interaction becomes 2558.875+74.07470.336≈1.478>1.4. Both tension and interaction fail; shear remains 25kN.

Animation labOut-of-plane bolt tension and prying2 concepts · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. A bracket moment can create compression at the plate contact and tension in the bolt rows.
  2. The original assumed pivot/compression line determines each row distance.
  3. Under the elastic row model, a farther tension row attracts more tension. Direct shear may act simultaneously.
  4. Flexible plates can add prying force. Use nominal tension and interaction rules exactly as specified by the course.
Connection example 5: separate moment and shear bolt groups

Design the bolt groups joining a 610×229×140 UB floor beam to a 254×254×132 UC. Steel is S355 and bolts are Grade 8.8 M24. Characteristic moments are 160kN·m dead and 90kN·m imposed; characteristic shears are 250kN dead and 160kN imposed.

Original source: LectureNotes/Ch 2_Connection.pdf — p. 29, p. 30. Values tagged given are in the question or diagram; lookup values come from a named table; calculated values follow from the working; assumptions are stated explicitly.

Read the diagram and collect the data

InputOrigin
Given actionsSeparate moment and shear dead/imposed components in question table; factor each once.
Given force-couple arm595mm between flange force lines in lecturer diagram/solution; not the nominal 610mm beam depth.
Selected fastenersFour upper flange bolts; four lower for opposite moment direction; eight web bolts, all M24.
Selected bearing detailLecturer p.30 selects 12mm end plate,55mm end distance and 70mm pitch. These are design choices, not task givens.
LookupM24 As=353mm2; Grade 8.8 pt=560,ps=375,pbb=1,000; S355 pbs=550,Us=510; Ub=800Nmm2.

Before calculating: recognition and strategy

Use the source idealisation: bending is a tension/compression force couple at the flanges; vertical shear is carried by a separate web-bolt group. Moment divided by the perpendicular couple arm gives flange force. Because groups have separate assigned actions, do not distribute the flange tensile force among the web bolts.

1. Design the tension flange group

Simple explanation: How two flange forces make a moment

Two opposite forces form a turning pair, like two hands turning a wheel.

How two flange forces make a moment — Two opposite forces form a turning pair, like two hands turning a wheel.
Sketch, not to scale; use the original dimensions.
  1. Identify the separation between their actual force lines.
  2. Required force equals moment divided by that separation.
  3. Design the relevant flange group for that force.

Remember: The force-line separation is not automatically the overall section depth.

Related concept and full method

M=1.4×160+1.6×90=224+144=368kN·mFflange=Mz=3680.595=618.487kNPnom,one=0.8×560×3531,000=158.144kNn≥618.487158.144=3.911→select4Nominal tension resistance of the whole group: Pnom=4×158.144=632.576kN>618.487Passes.

For the moment direction shown, the lower flange region supplies compression and the upper group tension. The extra lower four bolts are not added to the upper group’s capacity; they provide the corresponding group for the opposite moment direction/detail.

Animation labOut-of-plane bolt tension and prying2 concepts · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. A bracket moment can create compression at the plate contact and tension in the bolt rows.
  2. The original assumed pivot/compression line determines each row distance.
  3. Under the elastic row model, a farther tension row attracts more tension. Direct shear may act simultaneously.
  4. Flexible plates can add prying force. Use nominal tension and interaction rules exactly as specified by the course.

2. Design the shear group

Simple explanation: Count where the bolt can be sheared

The plate interfaces are the places trying to cut across the bolt.

Count where the bolt can be sheared — The plate interfaces are the places trying to cut across the bolt.
Sketch, not to scale; use the original dimensions.
  1. Count actual loaded shear planes, not merely visible plates.
  2. Choose shank or threaded area for the plane concerned.
  3. Compare group resistance with the force that group transfers.

Remember: Bolts on opposite sides of a splice do not all act in parallel.

Related concept and full method

V=1.4×250+1.6×160=350+256=606kNPs,one=375×3531,000=132.375kNFor 8 web bolts, demand per bolt: 6068=75.75kNPs,group=8×132.375=1,059.0kN>606Passes.
Animation labCount the bolt shear planes2 concepts · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. Load must cross an interface between the connected plates.
  2. A lap joint gives one shear plane through a bolt.
  3. A symmetric double-cover joint may provide two shear planes. Count load-transfer interfaces, not just visible plates.
  4. Use the source’s area and shear strength. Then check bearing, plate resistance and detailing separately.

3. Check selected end-plate bearing

Use d=24mm and standard hole d0=26mm. The chosen 12mm plate and 70mm pitch give clear ligament 44mm. The chosen end distance is 55mm.

Pbb=24×12×1,0001,000=288kNlc=70−26=44mmB1=24×12×5501,000=158.4kNB2=0.5×55×12×5501,000=181.5kNNet-clearance term between holes: 1.5×44×12×5101,000=403.92kNUpper cap: 2×24×12×8001,000=460.8kNPbs=min(158.4,181.5,403.92,460.8)=158.4kN

Both bearing resistances exceed the 75.75kN per-bolt demand and also exceed the 132.375kN shear resistance, so shear governs the web group.

Animation labBearing and the remaining ligament1 concept · 3 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. Force transfers through contact between bolt and connected plate.
  2. The plate around the hole carries bearing stress. Bolt bearing and plate bearing are separate checks.
  3. A short ligament can tear out towards the end. The direction of force determines the relevant edge.
  4. Evaluate every specified bearing and ligament bound for each layer and retain the smallest applicable resistance.

4. State what has actually been designed

Simple explanation: What to do when one input is missing

A calculator cannot supply a dimension that the drawing never gave.

What to do when one input is missing — A calculator cannot supply a dimension that the drawing never gave.
Sketch, not to scale; use the original dimensions.
  1. Separate given values, table values and calculated values.
  2. Complete the checks whose required inputs are available.
  3. State the missing input beside the remaining conditional result.

Remember: An illustrative assumption must not become an unstated exam given.

Related concept and full method

The flange tension and web shear/bearing bolt checks pass under the source’s force-couple idealisation. The source explicitly says only bolts have been designed; welds, end plates, stiffeners, column flange and column web require separate design. The 12mm end-plate bearing calculation is not a complete end-plate bending/prying check.

Animation labSeparate the moment couple and shear5 concepts

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. A simplified moment connection assigns different actions to different fastener groups.
  2. Opposite flange forces separated by z resist moment: .
  3. The web fasteners or welds carry the assigned vertical shear in this model.
  4. Flange force, web shear, plate bearing and detailing each need their specified checks.

Compact exam answer

ULS M=368kN·m; flange force=618.487kN. Four M24 Grade 8.8 flange bolts give nominal tension 632.576kN. ULS V=606kN; eight M24 web bolts give shear 1,059.0kN. Selected 12mm plate gives bolt bearing 288kN and plate bearing 158.4kN per bolt, both>75.75kN. Bolts pass; remaining connection components are outside the source calculation.

Mistakes to avoid

  • Use 595mm force-couple arm, not nominal beam depth 610mm.
  • Do not add bottom compression-side bolts to the upper tensile group.
  • Do not call the end plate fully designed after checking only bearing.

Procedure for an unfamiliar variant

  1. Factor moment and shear components separately.
  2. Resolve bending moment into flange force using the stated couple arm.
  3. Size the tension group using nominal bolt tension.
  4. Assign shear to the web group and check its bearing path.
  5. Document which other joint components are not included in the bolt-only exercise.

Independent self-check

Try it yourself. If the ultimate moment becomes 400kN·m, keeping 595mm arm and four flange bolts, is the tension group adequate?

Reveal answer and reasoning

F=4000.595=672.269kN>632.576kN, so no. Required count≥672.269158.144=4.251; at least 5 by strength alone, but the final symmetric layout and plate/prying design must also be revised.

Animation labOut-of-plane bolt tension and prying1 concept · 2 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. A bracket moment can create compression at the plate contact and tension in the bolt rows.
  2. The original assumed pivot/compression line determines each row distance.
  3. Under the elastic row model, a farther tension row attracts more tension. Direct shear may act simultaneously.
  4. Flexible plates can add prying force. Use nominal tension and interaction rules exactly as specified by the course.
Animation labOut-of-plane bolt tension and prying2 concepts · 3 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. A bracket moment can create compression at the plate contact and tension in the bolt rows.
  2. The original assumed pivot/compression line determines each row distance.
  3. Under the elastic row model, a farther tension row attracts more tension. Direct shear may act simultaneously.
  4. Flexible plates can add prying force. Use nominal tension and interaction rules exactly as specified by the course.

Long joints and large grip Background

Source: Chapter 2 p.24.More than two bolts and a joint longer than 500 mm → reduce the shear capacity under clause 9.3.6.1.4. Total clamped thickness over 5 bolt diameters for ordinary bolts → the large-grip clause 9.3.6.1.5 applies. The course material does not give these formulas, so just state that a reduction is needed; do not invent a factor.

Animation labLoad sharing along a long joint1 concept

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. Several bolts share a connection force, but a long joint need not distribute it perfectly evenly.
  2. Compatibility between the connected plates influences force attracted by bolts near the ends.
  3. Joint length is measured along the load path; grip is through the connected thickness.
  4. Apply long-joint or large-grip provisions only when their conditions are met. Arrows here are qualitative.

Fillet welds: throat and strength per millimetre Always examined

Simple explanation: Why the weld throat is smaller than its leg

The shortest cut through the weld is thinner than the outside leg.

Why the weld throat is smaller than its leg — The shortest cut through the weld is thinner than the outside leg.
Sketch, not to scale; use the original dimensions.
  1. For the stated equal-leg 90° fillet, throat is approximately 0.7 × leg.
  2. Multiply throat area by the matching weld design strength.
  3. For force per length, use a one-millimetre weld strip.

Remember: Choose strength from both the steel grade and electrode class.

Related concept and full method

Source: Chapter 2 pp.31–33.A 90° fillet weld with equal legs ss has an effective throat a≈0.7sa\approx0.7s, the shortest cut through the weld. The simplified method compares the resultant force per millimetre of weld qq with the throat’s strength per millimetre.

qcapacity=apw1,000=0.7spw1,000Units: kNmm. Required weld leg: s=1,000qrequired0.7pwUnits: mm.

pwp_w depends on both the steel and the electrode: S355 with Class 42 → 250 N/mm² (“42” is not pwp_w); S275 → 220; S355 with Class 35 → 220; S460 with Class 50 → 280.

(Recognition only.) The directional method splits the force into a part along the weld FLF_L and a part across it FTF_T; the transverse strength may be raised by KK, then (FL/PL)2+(FT/PT)2≤1(F_L/P_L)^2+(F_T/P_T)^2\le1. All the course’s numerical examples use the simplified method; do not mix them.

Concept map: How a fillet weld carries load: throat, strength per millimetre and effective length

Concept map

How a fillet weld carries load: throat, strength per millimetre and effective length

Every weld question starts from three ideas: a weld breaks at its narrowest part (the throat); how much each millimetre carries; and not all of the drawn length counts. Forgetting ×0.7 or −2s is the most common weld mistake.

Text version (from cause to result)

  1. Cause

    ss The leg of a fillet weld

    A fillet weld has a triangular cross-section. An “8 mm weld” means its leg s=8 mms=8\text{ mm}.

  2. Key ideaWhere marks are lost

    a≈0.7sa\approx0.7s The narrowest cut: the throat

    The shortest cut through the weld is the throat of the triangle, about 0.7 × the leg, so that is where the weld breaks most easily.

    The throat is about 0.7 × the leg
  3. What changes itWhere marks are lost

    pwp_w Weld strength: steel + electrode

    S355 with Class 42 electrodes → 250 N/mm² (“42” is not pwp_w); S275 → 220; S355 with Class 35 → 220.

  4. What changes it

    The ends are not fully formed

    The start and end of every weld run are not fully formed and cannot be counted.

    Not all of the drawn length counts
  5. Key idea

    qq Strength per millimetre (kN/mm)

    Throat × weld strength is the force each millimetre of weld can carry. Handy S355/E42 values: 6 mm → 1.05; 8 mm → 1.40; 10 mm → 1.75 kN/mm.

    Formula

    q=0.7 s pw1000  (kN/mm)q=\frac{0.7\,s\,p_w}{1000}\;(\text{kN/mm})
  6. Key ideaWhere marks are lost

    LeffL_{\text{eff}} Effective length = actual − 2s

    Deduct ss at each end of every run. When designing, go the other way: required effective length + 2s2s, rounded up.

    Formula

    Leff=Lactual−2sL_{\text{eff}}=L_{\text{actual}}-2s
  7. What changes it

    Size rules

    Minimum effective length: the larger of 4s4s and 40 mm; minimum leg by the thicker plate; maximum leg along a plate edge: thickness − 2 mm for plates ≥ 6 mm; in an end connection each longitudinal weld must be at least the transverse distance between the welds.

  8. Result

    q×Leffq\times L_{\text{eff}} Weld capacity

    Strength per millimetre times effective length is what the run can carry.

  9. How design deals with it

    Where it is used

    Eccentric weld groups: compare the resultant qRq_R with qq (see the eccentric-weld map); welded double angles: share the two lengths by the centroid distances; UB brackets: web welds take shear, flange welds take the moment.

    Why the two welds have different lengths
  10. Exam answer

    Exam: q first, then length and size checks

    E.g. q=0.7×8×250/1000=1.4 kN/mmq=0.7\times8\times250/1000=1.4\text{ kN/mm}; Leff=R/qL_{\text{eff}}=R/q; L=Leff+2sL=L_{\text{eff}}+2s, then check the size rules. In 2023 PTE the rule “length ≥ transverse spacing 200 mm” made the welds longer.

Tour steps

  1. 1. A weld breaks at its narrowest

    Leg ss → throat about 0.7s0.7s.

  2. 2. Strength per millimetre

    Throat × pwp_w ÷ 1000 → kN/mm. pwp_w depends on both the steel and the electrode.

  3. 3. Not all the length counts

    Deduct ss at each end of every run, and meet the size rules.

  4. 4. Capacity and where it is used

    q×Leffq\times L_{\text{eff}}, used for weld groups, double angles and brackets.

  5. 5. In the exam

    Write qq, then the lengths, then the size checks.

Animation labFrom fillet leg to effective throat1 concept · 6 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat . It is shorter than the leg.
  3. Effective resisting area = . With here, capacity per length is .
  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.

Example: how much can 6 mm of weld carry per millimetre? Often examined

Simple explanation: Keep the units on the same scale

Changing units is like changing the ruler, not the object.

Keep the units on the same scale — Changing units is like changing the ruler, not the object.
Sketch, not to scale; use the original dimensions.
  1. 1kN=1,000N; 1m=1,000mm.
  2. Area needs two length conversions; inertia needs four.
  3. Convert before substituting, then check the final unit.

Remember: A kN·m moment becomes 1,000,000 N·mm, not 1,000.

Related concept and full method

Source: Chapter 2 p.31 and L2 slide 6.Find: the strength per millimetre of weld. Given leg s=6 mms=6\text{ mm}, S355 with Class 42 electrodes → Table 9.2a gives pw=250 N/mm2p_w=250\text{ N/mm}^2.

Throat area in a one-millimetre strip

A one-millimetre strip has throat area a×1mm. First calculate the throat; this is why the factor 0.7 appears.

a=0.7×6=4.2mm; Astrip=4.2mm×1mm=4.2mm2.
Animation labFrom fillet leg to effective throat1 concept · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat . It is shorter than the leg.
  3. Effective resisting area = . With here, capacity per length is .
  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.

Multiply throat area by design strength

Pstrip=4.2mm2×250Nmm2=1,050N=1.05kNq=1.05kN1mm=1.05kNmm

Exam script: q=0.7×6×2501,000=1.05kNmm. This is capacity per effective length; multiply by effective weld length for total capacity.

Animation labFrom fillet leg to effective throat2 concepts · 2 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat . It is shorter than the leg.
  3. Effective resisting area = . With here, capacity per length is .
  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.

Try it yourself. What is the corresponding strength of an 8mm weld with the same materials?

Reveal answer and reasoning

a=0.7×8=5.6mm. q=5.6×2501,000=1.40kNmm. Capacity scales with leg size when materials remain the same.

Animation labFrom fillet leg to effective throat1 concept · 2 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat . It is shorter than the leg.
  3. Effective resisting area = . With here, capacity per length is .
  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.
Animation labFrom fillet leg to effective throat1 concept · 2 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat . It is shorter than the leg.
  3. Effective resisting area = . With here, capacity per length is .
  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.

Weld effective length and size rules Often examined

Simple explanation: Drawn length and useful length differ

The start and end of a weld are not credited as fully effective in this course model.

Drawn length and useful length differ — The start and end of a weld are not credited as fully effective in this course model.
Sketch, not to scale; use the original dimensions.
  1. Find the effective length required by strength.
  2. Add the specified end allowance to each separate run.
  3. Round up, then check minimum size, spacing and returns.

Remember: Strength alone does not prove a weld detail is acceptable.

Related concept and full method

Chapter 2 p.34, Figure 9.3. End returns continue weld around corners; they are not the main longitudinal load-transfer lengths.
Chapter 2 p.34, Figure 9.3: an end return continues the weld around a corner; it is not the main longitudinal load-transfer weld. The source labels Return, 2s, meaning return length 2s; s is the weld leg. Other labels identify the Seat Bracket, Tension Member, End Connection Plate, Connection Angle and Beam End Connection.Open full-size image

Source: Chapter 2 pp.33–34.For a straight weld: effective length Leff=Lactual−2sL_{\text{eff}}=L_{\text{actual}}-2s (start and end deducted). When designing, go the other way: required effective length + 2s2s, rounded up. Deduct for every run, not once for the whole connection.

Minimum effective length: the larger of 4s4s and 40 mm. Minimum leg (by the thicker plate): ≤6 mm → 3 mm; 7–13 mm → 5 mm; 14–19 mm → 6 mm; >19 mm → 8 mm. Maximum leg along a plate edge: plate < 6 mm → plate thickness; ≥ 6 mm → thickness − 2 mm.

Corner returns at least 2s2s; lap length at least max⁡(5t, 25 mm)\max(5t,\,25\text{ mm}) (tt = thinner plate). In an end connection, each longitudinal weld must be at least as long as the transverse distance between the welds. Intermittent welds are not suitable where fatigue matters. In answers, write these size checks as well as strength.

Connection example 6: balance two weld lengths about the load line

Design the side fillet welds for a 65×50×8 angle carrying 60kN characteristic dead tension and 70kN characteristic imposed tension through its centroid. Use S355 steel and Class 42 electrode.

Original source: LectureNotes/Ch 2_Connection.pdf — p. 38. Values tagged given are in the question or diagram; lookup values come from a named table; calculated values follow from the working; assumptions are stated explicitly.

Read the diagram and collect the data

InputOrigin
Given loads60kN dead,70kN imposed, arrows through dashed centroidal axis.
Given geometryThe left sketch labels 65×50×8 L; connected-leg width 65mm, centroid distance 21.1 and 43.9mm.
Design choiceLecturer tries 6mm fillet and final side lengths 140mm (X),75mm (Y), shown at right.
LookupTable 9.2a, S355 row/Class 42 column: pw=250Nmm2. Throat a=0.7s.

Before calculating: recognition and strategy

A longer weld must be put on the side closer to the load line. Treat the two parallel weld lines as supports of the tensile force across the 65mm separation: force equilibrium gives RX+RY=P; moment equilibrium about X gives RY×65=P×21.1. Equal weld lengths would move the connection resultant away from the angle centroid.

1. Factored tensile force

P=1.4×60+1.6×70=84+112=196kN
Animation labFrom characteristic to design load1 concept · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. G is permanent load; Q is imposed load. A surface load and a line load also have different units.
  2. This illustration uses the course gravity case . Other combinations in the original text retain their own factors.
  3. For illustrative , change Q and watch each separate contribution.
  4. Do not carry this ULS total automatically into deflection. Follow the stated SLS load case.

2. Select a trial leg and find capacity per length

Simple explanation: Why the weld throat is smaller than its leg

The shortest cut through the weld is thinner than the outside leg.

Why the weld throat is smaller than its leg — The shortest cut through the weld is thinner than the outside leg.
Sketch, not to scale; use the original dimensions.
  1. For the stated equal-leg 90° fillet, throat is approximately 0.7 × leg.
  2. Multiply throat area by the matching weld design strength.
  3. For force per length, use a one-millimetre weld strip.

Remember: Choose strength from both the steel grade and electrode class.

Related concept and full method

s=6mm→a=0.7×6=4.2mmq=apw1,000=4.2×2501,000=1.05kNmmRequired total effective length: Pq=1961.05=186.667mm

The angle edge thickness is 8mm, so the source maximum edge-weld leg 8−2=6mm permits this selection. The supporting plate thickness is not given; its effect on the minimum weld-size rule remains a detailing condition.

Animation labFrom fillet leg to effective throat2 concepts · 2 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat . It is shorter than the leg.
  3. Effective resisting area = . With here, capacity per length is .
  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.

3. Share force and effective length between the sides

Simple explanation: Why two weld lengths can be unequal

Two side welds must balance the load about its actual line of action.

Why two weld lengths can be unequal — Two side welds must balance the load about its actual line of action.
Sketch, not to scale; use the original dimensions.
  1. Find the load line and the lever arm to each weld.
  2. Balance moments as well as the total force.
  3. Convert each weld’s force into its own required length.

Remember: Equal-looking legs do not justify equal weld forces without equilibrium.

Related concept and full method

RY=196×21.165=63.6246kNRX=196−63.6246=132.3754kNAlternatively calculate directly 196×43.965. LX,eff=132.37541.05=126.0718mmLY,eff=63.62461.05=60.5949mm

Check: the forces sum 196kN and the required lengths sum 186.6667mm. The larger 43.9mm opposite lever arm produces the larger SideX force.

Animation labBalance two weld forces2 concepts · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. The angle centroid/load line is generally not halfway between the two weld runs.
  2. . Both weld runs contribute to the applied force.
  3. . The run nearer the load line carries more force.
  4. For equal throat resistance per length, the required effective lengths follow the same ratio. Add detailing allowances afterwards.

4. Add end allowances, round up and check the actual lengths

Simple explanation: Drawn length and useful length differ

The start and end of a weld are not credited as fully effective in this course model.

Drawn length and useful length differ — The start and end of a weld are not credited as fully effective in this course model.
Sketch, not to scale; use the original dimensions.
  1. Find the effective length required by strength.
  2. Add the specified end allowance to each separate run.
  3. Round up, then check minimum size, spacing and returns.

Remember: Strength alone does not prove a weld detail is acceptable.

Related concept and full method

Side X actual length: ≥126.0718+2×6=138.0718mm→140mmSide Y actual length: ≥60.5949+12=72.5949mm→75mmProvided effective length: X=140−12=128mm;Y=75−12=63mmResistance: X=128×1.05=134.4kN>132.3754Y=63×1.05=66.15kN>63.6246

Each effective length exceeds max(4×6,40)=40mm. The physical side lengths 140 and 75mm also exceed the 65mm transverse separation, matching the source detailing check. The extra rounding increases available resistance; the actual force split still follows equilibrium. End-return/support-plate details are not fully specified, so this is the completed requested side-weld strength/length design, not a complete fabrication detail.

Animation labFrom fillet leg to effective throat2 concepts · 2 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat . It is shorter than the leg.
  3. Effective resisting area = . With here, capacity per length is .
  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.

Compact exam answer

P=196kN. Use 6mm fillet, q=1.05kNmm. Force split X/Y=132.375/63.625kN. Required effective lengths 126.072/60.595mm. Add 12mm to each and provide 140mm (X),75mm (Y); effective capacities 134.4/66.15kN exceed the assigned forces.

Mistakes to avoid

  • Read the angle label: the source says 8mm thick, not 6mm.
  • Use the opposite centroid lever arm when allocating weld force.
  • Add 2s separately to both weld runs.
  • Do not use total capacity alone if one side is too short.

Procedure for an unfamiliar variant

  1. Locate the centroidal load line and both weld lines.
  2. Factor loads and select a permitted trial weld leg.
  3. Use force and moment equilibrium for the two side forces.
  4. Divide each force by weld strength per length.
  5. Add individual end deductions back, round up, and recheck each side.

Independent self-check

Try it yourself. Suppose the same 196kN force acts midway between the 65mm-spaced weld lines. What physical length is required on each side for 6mm weld?

Reveal answer and reasoning

Each side takes 98kN. Required effective length=981.05=93.333mm. Add 12mm→105.333mm; choose 110mm each. Centred loading makes equal lengths appropriate.

Animation labBalance two weld forces2 concepts · 2 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. The angle centroid/load line is generally not halfway between the two weld runs.
  2. . Both weld runs contribute to the applied force.
  3. . The run nearer the load line carries more force.
  4. For equal throat resistance per length, the required effective lengths follow the same ratio. Add detailing allowances afterwards.
Connection example 9: a welded single unequal angle

Check a 75×50×6 S355 single angle connected by its long leg under 95kN dead plus 40kN imposed tension, and design the two side welds with Class 42 electrode.

Original source: LectureNotes/Ch 2_Connection.pdf — p. 42. Values tagged given are in the question or diagram; lookup values come from a named table; calculated values follow from the working; assumptions are stated explicitly.

Read the diagram and collect the data

InputOrigin
Given loads95kN dead and 40kN imposed, task text.
Given dimensions75×50×6 angle; source diagram shows 72 and 47mm half-heel widths and 12.1mm centroid height.
Lookup centroid24.4mm from SideX stated from section table in solution and labelled in diagram. Opposite arm 75−24.4=50.6mm.
Lookup strengthsS355 thickness 6mm → py=355; S355/Class 42 →pw=250Nmm2.
Design choice4mm fillet, physical lengths 200mm (X),100mm (Y), lecturer solution.

Before calculating: recognition and strategy

First check that the angle itself can carry the force: stronger welds cannot cure a weak angle. With no bolt holes, the gross area is effective, but a single welded connected leg still has the 0.3a2 reduction for the unconnected leg. Then balance the two parallel weld forces about the centroid using their opposite lever arms.

1. Factored force and welded-angle resistance

Simple explanation: One connected leg does not load both legs equally

The connected leg receives the pull first; the other leg receives it through the angle.

One connected leg does not load both legs equally — The connected leg receives the pull first; the other leg receives it through the angle.
Sketch, not to scale; use the original dimensions.
  1. Identify connected and outstanding legs from the drawing.
  2. Use the relevant bolted or welded angle rule.
  3. Keep the lecturer’s area convention consistent.

Remember: Bolted and welded reduction expressions are not the same rule.

Related concept and full method

P=1.4×95+1.6×40=133+64=197kNa1=(75−62)×6=72×6=432mm2a2=(50−62)×6=47×6=282mm2Ae=Ag=432+282=714mm2No holes.Pt=355(714−0.3×282)1,000=355(714−84.6)1,000=355×629.41,000=223.437kN>197Passes.

The 0.3 factor comes from the single welded angle rule on Ch 2 p.14. The bolted value 0.5 would be a different connection model.

Animation labWhy a connected angle leg matters2 concepts · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. Locate the connected leg, outstanding leg and centroid before using the table.
  2. Only the connected leg directly receives the fastener force.
  3. The outstanding area may not become equally effective at the same section; this motivates the effective-area rule.
  4. Bolted, welded, single-angle and double-angle details can have different rules. Preserve the formula attached to the original case.

2. Trial 4mm weld and balanced required lengths

Simple explanation: Why two weld lengths can be unequal

Two side welds must balance the load about its actual line of action.

Why two weld lengths can be unequal — Two side welds must balance the load about its actual line of action.
Sketch, not to scale; use the original dimensions.
  1. Find the load line and the lever arm to each weld.
  2. Balance moments as well as the total force.
  3. Convert each weld’s force into its own required length.

Remember: Equal-looking legs do not justify equal weld forces without equilibrium.

Related concept and full method

q=0.7×4×2501,000=0.70kNmmTotal effective length: Leff=1970.70=281.4286mmRX=197×50.675=132.9093kNRY=197×24.475=64.0907kNLX,eff=132.90930.70=189.8705mmLY,eff=64.09070.70=91.5581mm

The 12.1mm centroid height is visible in the section but is not the transverse lever arm for sharing these two side-weld forces. The side-to-side 24.4/50.6 dimensions are the relevant ones.

Animation labBalance two weld forces2 concepts · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. The angle centroid/load line is generally not halfway between the two weld runs.
  2. . Both weld runs contribute to the applied force.
  3. . The run nearer the load line carries more force.
  4. For equal throat resistance per length, the required effective lengths follow the same ratio. Add detailing allowances afterwards.

3. Final lengths, capacities and source correction

Simple explanation: Drawn length and useful length differ

The start and end of a weld are not credited as fully effective in this course model.

Drawn length and useful length differ — The start and end of a weld are not credited as fully effective in this course model.
Sketch, not to scale; use the original dimensions.
  1. Find the effective length required by strength.
  2. Add the specified end allowance to each separate run.
  3. Round up, then check minimum size, spacing and returns.

Remember: Strength alone does not prove a weld detail is acceptable.

Related concept and full method

End allowance per weld =2s=8mm. Side X actual length: ≥189.8705+8=197.8705mm→200mmSide Y actual length: ≥91.5581+8=99.5581mm→100mmProvided effective length on side X =200−8=192mm, resistance 134.4kN>132.9093. Side Y effective length =100−8=92mm, resistance 64.4kN>64.0907.

Both effective lengths exceed max(16,40)=40mm, and both physical lengths exceed 75mm separation. For the 6mm angle edge the maximum leg is 6−2=4mm, matching the selection. The minimum-size rule depends on the unknown supporting plate thickness; do not assume it from the sketch.

Animation labFrom fillet leg to effective throat3 concepts · 4 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat . It is shorter than the leg.
  3. Effective resisting area = . With here, capacity per length is .
  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.

Compact exam answer

P=197kN. Welded single-angle capacity=355(714−0.3×282)1,000=223.437kN. Use 4mm fillets with q=0.70kNmm. Required effective X/Y lengths 189.870/91.558mm. Provide 200/100mm physical lengths (192/92mm effective), giving 134.4/64.4kN against 132.909/64.091kN. Angle and weld strength pass; support-thickness detailing is unprovided.

Mistakes to avoid

  • Do not subtract holes from a welded angle with no holes.
  • The unconnected leg still needs the 0.3 reduction.
  • For the 4mm weld, the source writes “Add 12” (add 12) is a textual error; it should be 2s=8.
  • Do not use 12.1mm centroid height in the 75mm transverse weld-force split.

Procedure for an unfamiliar variant

  1. Check angle area and the appropriate welded single-leg resistance.
  2. Read centroid location from the source/table.
  3. Select a weld leg permitted by the angle edge.
  4. Balance side forces, calculate effective lengths, then add 2s to each.
  5. Verify each rounded side and the detailing conditions.

Independent self-check

Try it yourself. If the imposed load rises to 45kN, do the existing 200/100mm welds still pass?

Reveal answer and reasoning

P=133+72=205kN. SideX demand=205×50.675=138.307kN>134.4; SideY=66.693kN>64.4. Both weld sides fail although angle capacity 223.437 still passes.

Animation labBalance two weld forces3 concepts · 3 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. The angle centroid/load line is generally not halfway between the two weld runs.
  2. . Both weld runs contribute to the applied force.
  3. . The run nearer the load line carries more force.
  4. For equal throat resistance per length, the required effective lengths follow the same ratio. Add detailing allowances afterwards.
Connection example 10: welded splice and a minimum-size discrepancy

Design a welded double-cover splice transferring 700kN ultimate tension between 150×20mm S355 main plates. Cover thickness is 12mm. Use Class 42 electrode. Explain the lecturer’s 6mm-weld solution, then reconcile it with the chapter’s minimum weld-size table.

Original source: LectureNotes/Ch 2_Connection.pdf — p. 43, p. 44. Values tagged given are in the question or diagram; lookup values come from a named table; calculated values follow from the working; assumptions are stated explicitly.

Read the diagram and collect the data

InputOrigin
Given demand700kN ultimate; do not factor again.
Given platesMain width 150mm and thickness 20mm; two covers 12mm thick.
Selected cover widthLecturer chooses 100mm to leave flat room for edge welds; not a given dimension.
LookupS355 py=345 for 20mm main,355 for 12mm covers. pw=250Nmm2 for Class 42.
Detailing lookupChapter 2 p.33 Table 9.1: thicker part over 19mm requires minimum leg 8mm. Here the thicker connected main plate is 20mm.

Before calculating: recognition and strategy

The force enters one half-splice from the main plate and divides equally between two covers. Each cover has two longitudinal weld runs, so four runs share the 700kN on each side of the butt. Size runs using effective length, check laps/returns and check unperforated plate tension. The lecturer’s strength arithmetic is reproducible, but a final choice must also satisfy the supplied minimum-size rule.

1. Select and interpret the covers

Selected cover-plate width =100mm. Allowance on each side: 150−1002=25mm

This is an explicit design choice providing space to place the weld on the main plate. Two 12mm covers have combined thickness 24mm but are checked individually at half force 350kN. The source uses the full welded plate area: no bolt-hole deductions.

Animation labTension through an unperforated plate2 concepts · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. For this concentric, unperforated plate, the full width and thickness form the resisting section. There are no bolt holes to deduct.
  2. The illustrative width is 100 mm. Adjust thickness t: , in .
  3. Using illustrative , in kN. Use the actual material and thickness band for the original question.
  4. The covers are moved apart for visibility. A symmetric pair each carries half the force. Check the main plate, each cover and the welds separately.

2. Reproduce the lecturer’s strength calculation

Simple explanation: Drawn length and useful length differ

The start and end of a weld are not credited as fully effective in this course model.

Drawn length and useful length differ — The start and end of a weld are not credited as fully effective in this course model.
Sketch, not to scale; use the original dimensions.
  1. Find the effective length required by strength.
  2. Add the specified end allowance to each separate run.
  3. Round up, then check minimum size, spacing and returns.

Remember: Strength alone does not prove a weld detail is acceptable.

Related concept and full method

The source trials s=6mm: q=0.7×6×2501,000=1.05kNmmRequired total effective length per half: 7001.05=666.6667mm4 welds each require effective length: 666.66674=166.6667mmActual length per weld: ≥166.6667+2×6=178.6667mm→180mmProvided effective length per weld: 180−12=168mmHalf-splice resistance: 4×168×1.05=705.6kN>700kN

The four runs on the other side of the butt transfer the same 700kN in series. Do not add both halves to claim 1,411.2kN splice resistance.

Animation labFrom fillet leg to effective throat1 concept · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat . It is shorter than the leg.
  3. Effective resisting area = . With here, capacity per length is .
  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.

3. Reconcile the minimum-size table and give a corrected detail

The lecturer checks lap≥5×12=60mm, physical run 180≥100mm transverse spacing, and returns 15≥2×6=12mm. However the 20mm main plate triggers the 8mm minimum in Table 9.1 on p.33; the 6mm selection is inconsistent with that supplied table.

Select s=8mm: q=0.7×8×2501,000=1.40kNmmRequired effective length per weld: 7004×1.40=125mmActual length: ≥125+2×8=141mm→select145mmProvided effective length: 145−16=129mmResistance per half: 4×129×1.40=722.4kN>700Minimum effective length: max(4×8,40)=40mm<129Lap length: 145mm≥max(5×12,25)=60mmActual weld length 145mm≥100mm transverse spacing. Provide end return 20mm≥2×8=16mm. 12mm cover-plate edge, maximum weld leg =12−2=10mm≥8mm.

The corrected detail uses 8mm fillets,145mm physical longitudinal runs on each half of each cover edge, and 20mm returns. This is an authored correction, clearly distinguished from the lecturer’s dimensions.

Animation labFrom fillet leg to effective throat2 concepts · 4 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat . It is shorter than the leg.
  3. Effective resisting area = . With here, capacity per length is .
  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.

4. Verify main and cover plate tension

Simple explanation: Why holes reduce tension resistance

The pull must squeeze through the steel left beside the holes.

Why holes reduce tension resistance — The pull must squeeze through the steel left beside the holes.
Sketch, not to scale; use the original dimensions.
  1. Choose a possible fracture line across the member.
  2. Subtract the holes crossed by that line using hole diameter.
  3. Apply the course effective-area rule and its gross-area limit.

Remember: Do not subtract every hole anywhere in the connection.

Related concept and full method

Main plate: A=150×20=3,000mm2Pt=3,000×3451,000=1,035kN>700Each cover plate: A=100×12=1,200mm2Pt=1,200×3551,000=426kN>350Both plates together: Pt=2×426=852kN>700

The corrected welded load path is governed by 722.4kN weld resistance, above 700kN. Main and cover tension pass. Every area is unperforated, so it equals the effective area for this concentric plate connection.

Animation labTension through an unperforated plate1 concept · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. For this concentric, unperforated plate, the full width and thickness form the resisting section. There are no bolt holes to deduct.
  2. The illustrative width is 100 mm. Adjust thickness t: , in .
  3. Using illustrative , in kN. Use the actual material and thickness band for the original question.
  4. The covers are moved apart for visibility. A symmetric pair each carries half the force. Check the main plate, each cover and the welds separately.

Compact exam answer

Source arithmetic:6mm fillets,180mm physical runs give 705.6kN per half; plates give 1,035kN main and 852kN cover pair. But Table 9.1 requires 8mm for the 20mm thicker part. Corrected detail:8mm fillets,145mm physical runs on each of four runs per half,20mm returns. Effective length 129mm/run gives 722.4kN; lap, length and edge-leg limits pass.

Mistakes to avoid

  • Four parallel runs occur on each half-splice; opposite halves are in series.
  • The cover width 100mm is selected, not the 150mm main width.
  • Strength adequacy does not override the supplied minimum weld-size table.
  • Increasing leg size changes the 2s length deduction.

Procedure for an unfamiliar variant

  1. Select cover width with room for welds and check plate strength.
  2. Count parallel weld runs on one transfer side only.
  3. Find required effective length, add 2s and round up.
  4. Check minimum/maximum leg, lap, returns and transverse-spacing rules.
  5. Resolve source discrepancies explicitly and verify the corrected detail.

Independent self-check

Try it yourself. For the corrected 8mm welds, would 140mm physical longitudinal runs be sufficient?

Hint

Recompute effective length after selecting the physical length.

Reveal answer and reasoning

Effective length 140−16=124mm. Resistance=4×124×1.40=694.4kN<700kN, so no. Rounding the 141mm minimum down to 140mm loses required capacity.

Animation labFrom fillet leg to effective throat1 concept · 2 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat . It is shorter than the leg.
  3. Effective resisting area = . With here, capacity per length is .
  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.
Animation labFrom fillet leg to effective throat2 concepts · 2 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat . It is shorter than the leg.
  3. Effective resisting area = . With here, capacity per length is .
  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.

Butt welds and inspection Background

Source: Chapter 2 p.34.If the weld metal is at least as strong as the parent plate, a full-penetration butt weld can be taken as equally strong. Full penetration is achieved by back-gouging and welding the second side, or by using a backing plate. A partial-penetration joint does not automatically have the full plate strength. In a sketch, show the prepared plate edges and make clear whether penetration is full or partial.

Animation labFull and partial weld penetration1 concept

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. Two plates meet edge to edge. The open groove in this schematic exposes the thickness that must be joined.
  2. A full-penetration butt weld joins through the complete thickness. The gold section shows the continuous weld metal.
  3. A partial-penetration weld leaves part of the thickness unjoined. The dark root gap is not resisting weld metal.
  4. The course permits parent-metal strength for full penetration when weld metal is not weaker. Confirm penetration and inspection; do not give the same capacity automatically to a partial joint.

Eccentric weld group: use line properties Always examined

Simple explanation: Only the weld lines resist as weld

Imagine a wire rectangle: its empty middle is not more wire.

Only the weld lines resist as weld — Imagine a wire rectangle: its empty middle is not more wire.
Sketch, not to scale; use the original dimensions.
  1. Count only the weld runs actually shown.
  2. Use their total length and line second moments.
  3. Combine direct and torsional forces at the critical location.

Remember: Line second moments have units mm3; plate-area moments use mm4.

Related concept and full method

Simple explanation: Add arrows before taking the magnitude

Walking east and walking north do not point in the same direction.

Add arrows before taking the magnitude — Walking east and walking north do not point in the same direction.
Sketch, not to scale; use the original dimensions.
  1. Choose signed horizontal and vertical directions.
  2. Add contributions along each direction separately.
  3. For perpendicular components, use the right-triangle resultant.

Remember: Check the corner where direct and torsional components reinforce each other.

Related concept and full method

Source: Chapter 2 pp.35–37.For a closed rectangular weld bb wide and hh high, all four sides share the direct shear equally; the plate inside is not weld. Because every side has the same throat, the throat cancels when working in force per millimetre, so the “line inertia” is in mm³, not mm⁴.

L=2(b+h)Ix,line=2(h312)+2b(h2)2=h36+bh22Iy,line=2(b312)+2h(b2)2=b36+hb22Ip,line=Ix,line+Iy,line

Where the formula comes from: the two vertical sides each give h3/12h^3/12; the two horizontal sides, length bb at h/2h/2 from the centre, each give b(h/2)2b(h/2)^2 (parallel-axis rule). Swap bb and hh for IyI_y. A corner is at x=b/2x=b/2, y=h/2y=h/2. Measure the eccentricity ee from the weld centroid to the load line, not necessarily from the column face.

qs=PLqT=PerIp,lineBoth have units kNmm. qmax=(PL+Pe|x|Ip,line)2+(Pe|y|Ip,line)2

The critical corner is on the side where the vertical twist adds to the direct shear. Find the leg size from qmax⁡q_{\max} and pwp_w, then check the size rules. Note two different cases: load in the plane of the weld → use this section; bracket load perpendicular to the weld plane → use the “flanges take moment, web takes shear” method of example 8. A three-sided weld has a different centroid, length and inertia; work them out again.

Understanding map: Eccentric weld: “straight down” plus “twist”, combined at the furthest corner

Understanding map

Eccentric weld: “straight down” plus “twist”, combined at the furthest corner

The load is off the weld centre, so the weld carries two things at once: direct shear shared equally, and extra force at the corners from the twist. The two routes meet at qRq_R, which sets the weld size. The values are from 2024 BQ2(b).

Text version (in working order)

  1. From the question

    GG, QQ Dead, imposed load

    The unfactored loads (kN).

  2. From the question

    b×hb\times h Weld rectangle

    The four welds form a rectangle bb wide and hh high (mm). Treat the weld as a line; the empty middle is not weld.

  3. From the question

    load line\text{load line} Load position

    The load acts on the line of the right-hand weld.

  4. DemandWhere marks are lost

    PP Design load

    Dead × 1.4, imposed × 1.6.

    Formula

    P=1.4G+1.6QP=1.4G+1.6Q

    2024 BQ2(b)

    1.4×250+1.6×150=590 kN1.4\times250+1.6\times150=590\text{ kN}
  5. Worked outWhere marks are lost

    ee Eccentricity

    Measured from the weld centroid to the load line. A rectangle’s centroid is in the middle, so e=b/2e=b/2.

    2024 BQ2(b)

    e=2502=125 mme=\frac{250}{2}=125\text{ mm}
  6. Demand

    M=PeM=Pe Twisting moment

    The off-centre load tries to turn the plate — like a spanner: the further your hand, the bigger the twist.

    2024 BQ2(b)

    590×125=73 750 kN⋅mm590\times125=73\,750\text{ kN·mm}
  7. Worked out

    LL Total weld length

    All four sides added. Direct shear is shared equally over every millimetre.

    Formula

    L=2(b+h)L=2(b+h)

    2024 BQ2(b)

    2(250+200)=900 mm2(250+200)=900\text{ mm}
  8. Worked outWhere marks are lost

    JJ Polar inertia of the weld line

    How well the weld loop resists twisting. The weld is a line, so the unit is mm³.

    Formula

    Ix=h36+bh22Iy=b36+hb22J=Ix+IyI_x=\frac{h^3}{6}+\frac{bh^2}{2}\qquad I_y=\frac{b^3}{6}+\frac{hb^2}{2}\qquad J=I_x+I_y

    2024 BQ2(b)

    Ix=6.333×106,  Iy=8.854×106,  J=15.1875×106 mm3I_x=6.333\times10^6,\;I_y=8.854\times10^6,\;J=15.1875\times10^6\text{ mm}^3
  9. Worked out

    xx, yy Furthest corner

    The corner furthest from the centroid is twisted hardest: x=b/2x=b/2, y=h/2y=h/2.

  10. Demand

    qsq_s Direct shear per mm

    The load pulls “straight down”, shared equally along the whole weld.

    Formula

    qs=PL  (kN/mm)q_s=\frac{P}{L}\;(\text{kN/mm})

    2024 BQ2(b)

    590900=0.6556 kN/mm\frac{590}{900}=0.6556\text{ kN/mm}
  11. Demand

    MxJ\tfrac{Mx}{J} Twist: vertical part

    The twist force at the corner, vertical part (uses xx).

    2024 BQ2(b)

    73 750×12515.1875×106=0.6070 kN/mm\frac{73\,750\times125}{15.1875\times10^6}=0.6070\text{ kN/mm}
  12. Demand

    MyJ\tfrac{My}{J} Twist: horizontal part

    The twist force at the corner, horizontal part (uses yy).

    2024 BQ2(b)

    73 750×10015.1875×106=0.4856 kN/mm\frac{73\,750\times100}{15.1875\times10^6}=0.4856\text{ kN/mm}
  13. From the tablesWhere marks are lost

    pwp_w Weld design strength

    S355 with Class 42 or 50 electrodes → 250 N/mm²; S275 → 220; S355 with Class 35 electrodes → 220.

    Where it comes from: Data File p.3.

  14. DemandWhere marks are lost

    qRq_R Resultant per mm

    At the corner where the twist adds to the direct shear: add the vertical parts first, then combine with the horizontal part by Pythagoras.

    Formula

    qR=(qs+MxJ)2+(MyJ)2q_R=\sqrt{\left(q_s+\frac{Mx}{J}\right)^2+\left(\frac{My}{J}\right)^2}

    2024 BQ2(b)

    (0.6556+0.6070)2+0.48562=1.3527 kN/mm\sqrt{(0.6556+0.6070)^2+0.4856^2}=1.3527\text{ kN/mm}
  15. Worked out

    sreqs_{\text{req}} Required leg size

    The narrowest part, the throat, is about 0.7 × the leg; the strength per mm 0.7spw/10000.7sp_w/1000 must reach qRq_R.

    Formula

    s≥1000 qR0.7 pws\ge\frac{1000\,q_R}{0.7\,p_w}

    2024 BQ2(b)

    1000×1.35270.7×250=7.73 mm\frac{1000\times1.3527}{0.7\times250}=7.73\text{ mm}
  16. CheckWhere marks are lost

    s=8 mms=8\text{ mm} Weld chosen

    Round up to a standard size (6, 8, 10 mm) and check once more.

    2024 BQ2(b)

    0.7×8×2501000=1.4>1.3527 kN/mm  ✓\frac{0.7\times8\times250}{1000}=1.4>1.3527\text{ kN/mm}\;\checkmark

Tour steps

  1. 1. Design load

    P=1.4G+1.6Q=590 kNP=1.4G+1.6Q=590\text{ kN}.

  2. 2. Eccentricity and twist

    From the weld centroid to the load line: e=125e=125; twist M=PeM=Pe.

  3. 3. Treat the weld as a line

    The total length LL is for direct shear; JJ and the furthest corner x,yx,y are for the twist.

  4. 4. Two kinds of force

    Direct shear qs=P/Lq_s=P/L; the twist splits into vertical Mx/JMx/J and horizontal My/JMy/J.

  5. 5. Combine at the corner

    The two routes meet here: add the vertical parts, then use Pythagoras.

  6. 6. Find the weld size

    s≥1000qR/(0.7pw)=7.73s\ge1000q_R/(0.7p_w)=7.73 → use 8 mm, and check 1.4 > 1.3527 kN/mm.

Connection example 7: calculate a rectangular weld group from first principles

Find the maximum force per unit weld length and select a fillet weld for one side plate carrying 60kN dead plus 90kN imposed load. The weld is on all four sides of a 200mm×300mm rectangle; the force eccentricity from its centre is 300mm. Steel is S355 with Class 42 electrode.

Original source: LectureNotes/Ch 2_Connection.pdf — p. 39, p. 40. Values tagged given are in the question or diagram; lookup values come from a named table; calculated values follow from the working; assumptions are stated explicitly.

Read the diagram and collect the data

InputOrigin
Given geometryb=200mm,h=300mm; four weld sides. Centre is at half width/height: x=100,y=150mm at a corner.
Given load arme=300mm from group centroid, not from the right edge.
Given materialsS355/Class 42 → lookup pw=250Nmm2, Table 9.2a.
AssumptionUniform fillet size, rigid plate and line-weld elastic distribution, as in Ch 2 pp.35–37.

Before calculating: recognition and strategy

Separate direct shear PL from torsional force caused by Pe. Use the weld lines for centroid and inertia; the plate interior does not carry weld force. Derive line inertias with the parallel-axis rule. Then combine the horizontal and vertical force-per-length components at the right-hand corner, where vertical components add.

1. Geometry and factored force

L=2(b+h)=2(200+300)=1,000mmP=1.4×60+1.6×90=84+144=228kNM=Pe=228×300=68,400kN·mmr=1002+1502=32,500=180.278mm
Animation labA weld group is a set of lines2 concepts · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. The centre is empty: resistance comes from the weld lines, not a solid plate filling the group.
  2. Use line lengths for centroid weighting. Line second moments have units ; add the parallel-axis terms.
  3. Direct force per length is . The eccentric moment adds tangential flow proportional to distance from the centroid.
  4. Combine signed components at every candidate corner, then compare the maximum with throat resistance per length.

2. Derive both line second moments

Simple explanation: Only the weld lines resist as weld

Imagine a wire rectangle: its empty middle is not more wire.

Only the weld lines resist as weld — Imagine a wire rectangle: its empty middle is not more wire.
Sketch, not to scale; use the original dimensions.
  1. Count only the weld runs actually shown.
  2. Use their total length and line second moments.
  3. Combine direct and torsional forces at the critical location.

Remember: Line second moments have units mm3; plate-area moments use mm4.

Related concept and full method

About the horizontal centroidal x axis: two vertical welds each contribute h312; two horizontal welds each contribute b(h2)2. About the vertical axis reverse the roles.

Ix=2(300312)+2×200×1502=4,500,000+9,000,000=13,500,000mm3Iy=2(200312)+2×300×1002=1,333,333.333+6,000,000=7,333,333.333mm3Ip=Ix+Iy=20,833,333.333mm3

Why is the unit mm3? Weld-line length (mm) multiplied by distance squared (mm2) gives that unit. Do not substitute the second moment of area of a solid rectangular plate, bh312, whose unit is mm4.

Animation labA weld group is a set of lines1 concept · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. The centre is empty: resistance comes from the weld lines, not a solid plate filling the group.
  2. Use line lengths for centroid weighting. Line second moments have units ; add the parallel-axis terms.
  3. Direct force per length is . The eccentric moment adds tangential flow proportional to distance from the centroid.
  4. Combine signed components at every candidate corner, then compare the maximum with throat resistance per length.

3. Uniform direct shear per length

qs=PL=228kN1,000mm=0.228kNmm
Animation labA weld group is a set of lines1 concept · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. The centre is empty: resistance comes from the weld lines, not a solid plate filling the group.
  2. Use line lengths for centroid weighting. Line second moments have units ; add the parallel-axis terms.
  3. Direct force per length is . The eccentric moment adds tangential flow proportional to distance from the centroid.
  4. Combine signed components at every candidate corner, then compare the maximum with throat resistance per length.

4. Torsional components at the critical corner

qT=MrIp=68,400×180.27820,833,333.333=0.591888kNmmVertical component: MxIp=68,400×10020,833,333.333=0.32832kNmmHorizontal component: MyIp=68,400×15020,833,333.333=0.49248kNmm

The source uses cosφ=100r≈0.555 for the angle between the vertical direct shear and the tangential torsion force. The corner radius itself is not the force direction.

Animation labA weld group is a set of lines1 concept · 2 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. The centre is empty: resistance comes from the weld lines, not a solid plate filling the group.
  2. Use line lengths for centroid weighting. Line second moments have units ; add the parallel-axis terms.
  3. Direct force per length is . The eccentric moment adds tangential flow proportional to distance from the centroid.
  4. Combine signed components at every candidate corner, then compare the maximum with throat resistance per length.

5. Add components and calculate the maximum

Simple explanation: Add arrows before taking the magnitude

Walking east and walking north do not point in the same direction.

Add arrows before taking the magnitude — Walking east and walking north do not point in the same direction.
Sketch, not to scale; use the original dimensions.
  1. Choose signed horizontal and vertical directions.
  2. Add contributions along each direction separately.
  3. For perpendicular components, use the right-triangle resultant.

Remember: Check the corner where direct and torsional components reinforce each other.

Related concept and full method

qvertical=0.228+0.32832=0.55632kNmmqmax=0.556322+0.492482=0.742986kNmm

The opposite column of weld has vertical components subtracting, hence a smaller resultant. The upper and lower right corners have the same maximum magnitude.

Animation labA weld group is a set of lines1 concept · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. The centre is empty: resistance comes from the weld lines, not a solid plate filling the group.
  2. Use line lengths for centroid weighting. Line second moments have units ; add the parallel-axis terms.
  3. Direct force per length is . The eccentric moment adds tangential flow proportional to distance from the centroid.
  4. Combine signed components at every candidate corner, then compare the maximum with throat resistance per length.

6. Size the fillet and check its resistance

Simple explanation: Why the weld throat is smaller than its leg

The shortest cut through the weld is thinner than the outside leg.

Why the weld throat is smaller than its leg — The shortest cut through the weld is thinner than the outside leg.
Sketch, not to scale; use the original dimensions.
  1. For the stated equal-leg 90° fillet, throat is approximately 0.7 × leg.
  2. Multiply throat area by the matching weld design strength.
  3. For force per length, use a one-millimetre weld strip.

Remember: Choose strength from both the steel grade and electrode class.

Related concept and full method

srequired=1,000qmax0.7pw=1,000×0.7429860.7×250=4.24564mmThe lecturer selects s=6mm. qcapacity=0.7×6×2501,000=1.05kNmm>0.742986Weld strength passes.

The closed four-side weld is treated as the full line rectangle by the source method. This differs from separately terminated side welds with 2s start/end deductions. The plate thickness is absent, so the numerical strength result is complete but minimum/maximum permitted leg size cannot be confirmed from Table 9.1/edge-thickness rules. The 6mm choice is the lecturer’s selection, conditional on those missing detailing inputs.

Animation labFrom fillet leg to effective throat1 concept · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat . It is shorter than the leg.
  3. Effective resisting area = . With here, capacity per length is .
  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.

Compact exam answer

P=228kN,e=300mm,L=1,000mm,Ip,line=20.83333×106mm3. qs=0.228; torsion components 0.32832 vertical and 0.49248 horizontal kN/mm. qmax=0.742986kNmm. s≥4.246mm;6mm fillet supplies 1.05kNmm and passes weld strength. Plate-thickness detailing remains unverified because it is not given.

Mistakes to avoid

  • The two 300mm dimensions mean different things: height and eccentricity.
  • Use line inertia in mm3, not solid-plate inertia in mm4.
  • The dashed right edge still belongs to the stated four-side weld.
  • Do not certify minimum/maximum weld size without the plate thickness.

Procedure for an unfamiliar variant

  1. Identify every actual weld line and its load path.
  2. Find centroid, length and line inertias.
  3. Measure load eccentricity from the centroid.
  4. Calculate direct and torsional components and the critical resultant.
  5. Solve for leg size and check detailing separately.

Independent self-check

Try it yourself. Keep the same load and rectangle but move the load line through the weld centroid. Find required strength and leg by strength alone.

Reveal answer and reasoning

e=0 so torsion vanishes. q=2281,000=0.228kNmm. s≥1,000×0.228175=1.303mm by strength alone. The actual selected leg is still controlled by minimum/detailing rules; a 1.3mm design cannot be adopted just from this strength result.

Animation labA weld group is a set of lines1 concept · 3 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. The centre is empty: resistance comes from the weld lines, not a solid plate filling the group.
  2. Use line lengths for centroid weighting. Line second moments have units ; add the parallel-axis terms.
  3. Direct force per length is . The eccentric moment adds tangential flow proportional to distance from the centroid.
  4. Combine signed components at every candidate corner, then compare the maximum with throat resistance per length.
Connection example 8: flange welds carry moment, web welds carry shear

Design the bracket welds for 100kN dead plus 140kN imposed load at 250mm from the support. The bracket is cut from a 356×171×67 UB. The specified web-weld leg is half the flange-weld leg. Use S355 and Class 42 electrode.

Original source: LectureNotes/Ch 2_Connection.pdf — p. 41. Values tagged given are in the question or diagram; lookup values come from a named table; calculated values follow from the working; assumptions are stated explicitly.

Read the diagram and collect the data

InputOrigin
Given load100kN dead,140kN imposed; downward arrow at e=250mm from connection face.
Given weld geometryB=150mm across flange run; D=364.6mm vertical arm; a=280mm web run; all explicitly dimensioned.
Given size relationshipsweb=sflange2。
Lookup/modelpw=250Nmm2. Rotate about X1–X1 at bottom flange; flange weld takes moment, two web welds take direct shear. This is the source’s simplified force allocation.

Before calculating: recognition and strategy

Do not treat this as a rectangular in-plane torsion weld. The vertical load outside the supporting face produces flange tension and compression. Moment equilibrium gives tensile flange force F=MD. Divide that force by the effective flange weld length to get demand per millimetre. Because effective length depends on chosen leg, select a trial leg and verify it self-consistently.

1. Design force and force couple

P=1.4×100+1.6×140=140+224=364kNM=Pe=364×250=91,000kN·mmFlange force: F=MD=91,000364.6=249.589kN
Animation labSeparate the moment couple and shear1 concept · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. A simplified moment connection assigns different actions to different fastener groups.
  2. Opposite flange forces separated by z resist moment: .
  3. The web fasteners or welds carry the assigned vertical shear in this model.
  4. Flange force, web shear, plate bearing and detailing each need their specified checks.

2. Trial 12mm flange fillets

Simple explanation: How two flange forces make a moment

Two opposite forces form a turning pair, like two hands turning a wheel.

How two flange forces make a moment — Two opposite forces form a turning pair, like two hands turning a wheel.
Sketch, not to scale; use the original dimensions.
  1. Identify the separation between their actual force lines.
  2. Required force equals moment divided by that separation.
  3. Design the relevant flange group for that force.

Remember: The force-line separation is not automatically the overall section depth.

Related concept and full method

The source tries 12mm. The available 150mm run loses 2s=24mm at its ends, leaving 126mm effective. Use the printed weld run B, not the nominal 171mm section width.

Lflange,eff=150−2×12=126mmqflange=FLeff=249.589126=1.980862kNmmsneeded=1,000×1.9808620.7×250=11.3192mm12mm≥11.3192mm;qcap=0.7×12×2501,000=2.10kNmmFlange-weld resistance: 2.10×126=264.6kN>249.589Passes.

This also solves the implicit inequality 0.7pws(B−2s)1,000≥MD by a verified trial. Increasing s improves throat but shortens effective length, so do not omit the recheck.

Animation labFrom fillet leg to effective throat2 concepts · 3 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat . It is shorter than the leg.
  3. Effective resisting area = . With here, capacity per length is .
  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.

3. Apply the required half-size rule and check shear

Simple explanation: Why the weld throat is smaller than its leg

The shortest cut through the weld is thinner than the outside leg.

Why the weld throat is smaller than its leg — The shortest cut through the weld is thinner than the outside leg.
Sketch, not to scale; use the original dimensions.
  1. For the stated equal-leg 90° fillet, throat is approximately 0.7 × leg.
  2. Multiply throat area by the matching weld design strength.
  3. For force per length, use a one-millimetre weld strip.

Remember: Choose strength from both the steel grade and electrode class.

Related concept and full method

sweb=122=6mmEffective length per weld: Lweb,eff=280−2×6=268mmTotal effective web-weld length: 2×268=536mmqweb=364536=0.679104kNmmsneeded,web=1,000×0.679104175=3.88060mmThe provided 6mm gives qcap=1.05kNmm; web-weld resistance: 536×1.05=562.8kN>364Passes.

Even though strength alone needs only about 3.9mm, use 6mm to satisfy the given relationship to the 12mm flange weld.

Animation labFrom fillet leg to effective throat2 concepts · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat . It is shorter than the leg.
  3. Effective resisting area = . With here, capacity per length is .
  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.

4. Check lengths and identify the remaining thickness condition

Simple explanation: Drawn length and useful length differ

The start and end of a weld are not credited as fully effective in this course model.

Drawn length and useful length differ — The start and end of a weld are not credited as fully effective in this course model.
Sketch, not to scale; use the original dimensions.
  1. Find the effective length required by strength.
  2. Add the specified end allowance to each separate run.
  3. Round up, then check minimum size, spacing and returns.

Remember: Strength alone does not prove a weld detail is acceptable.

Related concept and full method

Minimum effective flange-weld length: max(4×12,40)=48mm<126Minimum effective web-weld length: max(4×6,40)=40mm<268

The source dimensions describe weld runs on the cut bracket, not a licence to infer other fabrication details from scale. The supporting column thickness is not stated. The result therefore establishes flange/web weld strength and the size ratio; applicability of the thicker-part minimum-size rule to the support must be confirmed separately.

Animation labFrom fillet leg to effective throat2 concepts · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat . It is shorter than the leg.
  3. Effective resisting area = . With here, capacity per length is .
  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.

Compact exam answer

P=364kN,M=91kN·m. About X1–X1, flange force=249.589kN.12mm flange weld has 126mm effective length and 264.6kN resistance.6mm web welds each have 268mm effective length, combined resistance 562.8kN. Both pass and web leg is half flange leg. Support thickness for minimum weld-size verification is not supplied.

Mistakes to avoid

  • The moment arm D is 364.6mm; the web run a is 280mm. They are not interchangeable.
  • Use two web welds, but the source’s tension-flange force is resisted by the specified flange run.
  • Subtract 2s using that run’s own leg size.

Procedure for an unfamiliar variant

  1. Identify the source pivot and the flange-force arm.
  2. Factor load and calculate moment/force couple.
  3. Try a flange leg, calculate its effective length and verify capacity.
  4. Apply the specified web/flange size relationship and check web shear.
  5. Check effective-length/detailing rules and state unprovided support data.

Independent self-check

Try it yourself. Keep the selected welds and increase the eccentricity to 300mm. What happens to the flange strength check?

Reveal answer and reasoning

Flange force becomes 364×300364.6=299.506kN, greater than 264.6kN. The flange weld fails while the unchanged direct web shear remains 364kN and still passes.

Animation labSeparate the moment couple and shear2 concepts · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. A simplified moment connection assigns different actions to different fastener groups.
  2. Opposite flange forces separated by z resist moment: .
  3. The web fasteners or welds carry the assigned vertical shear in this model.
  4. Flange force, web shear, plate bearing and detailing each need their specified checks.
Animation labA weld group is a set of lines1 concept · 5 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. The centre is empty: resistance comes from the weld lines, not a solid plate filling the group.
  2. Use line lengths for centroid weighting. Line second moments have units ; add the parallel-axis terms.
  3. Direct force per length is . The eccentric moment adds tangential flow proportional to distance from the centroid.
  4. Combine signed components at every candidate corner, then compare the maximum with throat resistance per length.

Practise this chapter: tutorials, assignments and past-paper answers →

Older-paper answers for this chapter (reference)