STEELWORK / CON4334
Worked examples

2024 BQ2(a): back-to-back bolted angles

Diagrams, explanations and answers are presented in reading order. No playback or response is required.
All answers shownChinese–English terminology
Diagrams, explanations and answers are presented in reading order. No playback or response is required.

Check bolt shear, bolt bearing, angle bearing and angle tension for two 125×75×8 S355 unequal angles connected back-to-back to the web of 305×305×118 UC by threeM20 Grade 8.8 bolts in 22mm holes. Design concentric tension is 350kN. The paper excludes checking the supporting UC.

Original source: Pastpaper/23ENGTY004.pdf — p. 3.

A given value comes from the question or diagram.

A lookup value comes from the named table.

A calculated value follows from the working.

Each assumption is stated where the calculation needs it.

Known information, diagram labels and unknowns

Follow contact pressure into the plate

The bolt may survive shear while the connected plate deforms or tears near the hole.

The labels distinguish bolt diameter d from hole diameter d₀. The arrow at the hole edge shows the bearing contact action.
The labels distinguish bolt diameter d from hole diameter d₀. The arrow at the hole edge shows the bearing contact action.

Prediction, then explanation. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.

Calculate every bound required by the supplied rule. The smallest applicable bound limits the connection at that layer.

Pbearing≤pbsdtP_{bearing}\le p_{bs}dt

pbs is the applicable bearing strength in N/mm²; d is nominal bolt diameter in mm; t is plate thickness in mm.

Scope. This diameter term alone is not the complete check. End-distance and clear-ligament limits, bolt bearing and each connected layer also matter.

Check and takeaway. Two covers and one main plate do not necessarily have the same thickness or strength. Compare the actual force share in each layer.

One connected leg does not load both legs equally

An angle carries tension through only one leg. Determine how much section area the design rule permits.

The force enters the connected leg first. The outstanding leg receives force through the angle corner and adjoining material.
The force enters the connected leg first. The outstanding leg receives force through the angle corner and adjoining material.

Prediction, then explanation. Keeping the same gross area does not guarantee the same tension resistance when the connection arrangement changes.

Separate connected and outstanding leg areas. Include the actual holes. Then use the supplied single-angle or double-angle effective-area rule.

Pt=pyAeP_t=p_yA_e

Ae is the effective area from the applicable angle rule in mm². py is the relevant design strength in N/mm².

Scope. Do not assume the whole gross area is effective. Symmetry, connected leg and connection type determine which rule applies.

Check and takeaway. The outstanding leg contributes through load transfer; the rule need not either count all of it or discard all of it.

A table value has conditions

Find a design property without mixing a row, column or standard from a different case.

The row and column meet at one cell. The table heading supplies the units and the conditions that give the cell meaning.
The row and column meet at one cell. The table heading supplies the units and the conditions that give the cell meaning.

Prediction, then explanation. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Match the complete section designation. Read the relevant axis and unit. For strength tables, select material, thickness and curve before interpolating.

Given values come from the question. Lookup values come from a named table. Assumed values require an explicit condition.

Scope. A missing row or omitted restraint cannot be recovered from a schematic’s scale. Keep the result conditional when required data are absent.

Check and takeaway. Record the table, row, column and unit beside the substitution. That makes a later check possible.

Apply the reasoning to this section’s data and conditions

InputSource/type
ForceGiven ultimatePu 350 kN, symmetric pair →175kN per angle.
Bolt materialM20 As=245mm2; Grade 8.8 ps=375, pbb=1,000, Ub=800Nmm2.
Central ply

Data File p.11, 305×305×118 UC web t=12.0mm.

Read the web column, not flange T=18.7mm.

Angle material8mm S355 →py 355; coursepbs 550,Us 510,Ke 1.1.
Area model

Use exact given 125/75/8 rectangular leg split as in the lecture.

The current unequal-angle table has a mislabelled 125×75 thickness row.

Do not import its inconsistent area 22.7cm2 as an 8mm angle.

Why this method applies

Count cuts through each loaded bolt

Find how many shear planes transfer the force through one side of the connection.

The middle plate moves against two cover plates. The two interfaces cut each bolt at two planes.
The middle plate moves against two cover plates. The two interfaces cut each bolt at two planes.

Prediction, then explanation. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Select the area at the actual shear plane. Multiply by bolt shear strength. Count only the bolts and planes in the same transfer stage.

Ps=psAs,Pgroup=nbnsPsP_s=p_sA_s,\qquad P_{group}=n_b n_s P_s

ps is bolt shear strength in N/mm²; As is the appropriate area in mm². nb counts bolts; ns counts equally loaded shear planes.

Scope. Use the thread area when threads cross the plane as required. Check bearing, plate failure and detailing separately.

Check and takeaway. Both halves of a butt splice carry the full transmitted force in sequence. Counting both halves together would double the apparent resistance.

Use the same mechanism: One connected leg does not load both legs equally. Keeping the same gross area does not guarantee the same tension resistance when the connection arrangement changes.

Apply the reasoning to this section’s data and conditions

The section view determines the number of shear planes.

Follow 350kN through three bolts into two angle legs, allocating 175kN to each angle.

For angle tension, deduct one hole on a transverse fracture path, apply effective-area caps and then the double-bolted-angle shear-lag reduction.

(i) Bolt shear —2 printed marks

Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Count where the bolt can be sheared

The plate interfaces are the places trying to cut across the bolt.

Count where the bolt can be sheared — The plate interfaces are the places trying to cut across the bolt.

Sketch, not to scale; use the original dimensions.

  1. Count actual loaded shear planes, not merely visible plates.
  2. Choose shank or threaded area for the plane concerned.
  3. Compare group resistance with the force that group transfers.

Remember: Bolts on opposite sides of a splice do not all act in parallel.

Related concept and full method

Each bolt has two shear interfaces: angle/UC web and UC web/angle. Per shear plane: Ps=245×3751,000=91.875kNDouble shear per bolt: Ps=2×91.875=183.75kNWhole group: 3×183.75=551.25kN>350Passes. Equivalently, demand per interface: 1753=58.333333kN<91.875

Mechanism detailsCount the bolt shear planes1 concept · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Load must cross an interface between the connected plates.
  2. A lap joint gives one shear plane through a bolt.
  3. A symmetric double-cover joint may provide two shear planes.

    Count load-transfer interfaces, not just visible plates.

  4. Use the source’s area and shear strength.

    Then check bearing, plate resistance and detailing separately.

(ii) Bolt bearing —2 printed marks

Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.

Apply the reasoning to this section’s data and conditions

Physical interpretation: The bolt can crush or tear the plate

A strong bolt can still push through a weak hole edge.

The bolt can crush or tear the plate — A strong bolt can still push through a weak hole edge.

Sketch, not to scale; use the original dimensions.

  1. Check the bolt and each connected plate’s bearing bounds.
  2. Use nominal bolt diameter for bearing; hole size for removed material.
  3. The smallest applicable resistance controls.

Remember: A short end distance may govern even when bolt shear passes.

Related concept and full method

Central UC web contact thickness 12mm (table lookup). Combined contact thickness of the two outer angles 8+8=16mm. Governing projected thickness: min(12,16)=12mmBolt bearing per bolt: 20×12×1,0001,000=240kNThree-bolt group: 3×240=720kN>350Passes.

Each outer 8mm contact individually provides 160kN against 58.333333kN.

The paired 320kN exceeds the central 240kN.

This checks the bolt bearing limit.

It does not perform the expressly excluded UC material-bearing or web-strength design.

Mechanism detailsBearing and the remaining ligament1 concept · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Force transfers through contact between bolt and connected plate.
  2. The plate around the hole carries bearing stress.

    Bolt bearing and plate bearing are separate checks.

  3. A short ligament can tear out towards the end.

    The direction of force determines the relevant edge.

  4. Evaluate every specified bearing and ligament bound for each layer and retain the smallest applicable resistance.

(iii) Bearing of the angles —6 printed marks

Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.

Apply the reasoning to this section’s data and conditions

Evaluate one angle under 175kN.

Use d 20 for projected bearing, d₀22 for ligament deductions, pitch 80 and end 50.

The ordinary-hole factor kbs=1.

Net clearance between holes: lc=80−22=58mmB1=kdtpbs=1×20×8×5501,000=88kNB2=0.5ketpbs=0.5×1×50×8×5501,000=110kNNet-clearance term: 1.5×58×8×5101,000=354.96kNUpper cap: 2×20×8×8001,000=256kNB3=min(354.96,256)=256kNBearing per bolt in each angle: min(88,110,256)=88kNThree-bolt resistance for each angle: 3×88=264kN>175For the angle pair, 528kN>350: passes.

Optional detailing observation, beyond the four requested strength checks: the closest transverse edge 41mm exceeds either M20 minimum 34/26.

The opposite 84mm free-edge distance exceeds the ordinary 11tε=11×8×275355=77.452mm maximum, so a complete detail would require review of that provision.

It does not change the arithmetic bearing result above.

Mechanism detailsBearing and the remaining ligament1 concept · 3 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Force transfers through contact between bolt and connected plate.
  2. The plate around the hole carries bearing stress.

    Bolt bearing and plate bearing are separate checks.

  3. A short ligament can tear out towards the end.

    The direction of force determines the relevant edge.

  4. Evaluate every specified bearing and ligament bound for each layer and retain the smallest applicable resistance.

(iv) Tensile capacity of the angles —7 printed marks

Test every possible fracture cut

Find the remaining steel area across a candidate tension-failure path.

The dashed fracture line crosses two hole centres. Subtract only the holes crossed by that candidate line.
The dashed fracture line crosses two hole centres. Subtract only the holes crossed by that candidate line.

Prediction, then explanation. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.

Subtract the hole widths crossed by the path, then multiply by thickness. Compare all plausible paths using the applicable course rule.

An=(b−nd0)tA_n=(b-nd_0)t

An is net area in mm²; b is plate width; d₀ is hole diameter; t is thickness, all in mm. n counts holes on this straight path.

Scope. This expression is for a straight cut. Effective area can require further shear-lag rules. Gross, net and effective areas must remain distinct.

Check and takeaway. Use the hole diameter, not the bolt diameter, when removing missing steel. The plate contains a hole, not solid steel around the bolt shank.

Use the same mechanism: One connected leg does not load both legs equally. Keeping the same gross area does not guarantee the same tension resistance when the connection arrangement changes.

Apply the reasoning to this section’s data and conditions

Physical interpretation: One connected leg does not load both legs equally

The connected leg receives the pull first.

The other leg receives it through the angle.

One connected leg does not load both legs equally — The connected leg receives the pull first; the other leg receives it through the angle.

Sketch, not to scale; use the original dimensions.

  1. Identify connected and outstanding legs from the drawing.
  2. Use the relevant bolted or welded angle rule.
  3. Keep the lecturer’s area convention consistent.

Remember: Bolted and welded reduction expressions are not the same rule.

Related concept and full method

The connected 125mm leg contains the hole.

The outstanding 75mm leg does not.

Split the shared 8mm heel equally so no area is counted twice.

As in the lecture, applyKe to the connected net leg and cap the unconnected leg at its gross area.

Connected-leg gross area: ag1=(125−82)×8=121×8=968mm2Outstanding leg: a2=(75−82)×8=71×8=568mm2Angle gross area: 968+568=1,536mm2Connected-leg net area: an1=(121−22)×8=99×8=792mm2Connected-leg effective area: ae1=min(1.1×792,968)=871.2mm2Outstanding-leg effective area: ae2=min(1.1×568,568)=568mm2Total effective area: Ae=871.2+568=1,439.2mm2Reduction for the bolted double-angle connection: 0.25a2=0.25×568=142mm2Resistance area per angle: 1,439.2−142=1,297.2mm2Pt,each=355×1,297.21,000=460.506kN>175Pt,pair=2×460.506=921.012kN>350Passes.

The fracture path cuts one of the three longitudinally aligned holes.

Deducting all three from the same transverse section is incorrect.

Conversely, multiplying the outstanding 568 by 1.1 without its cap would invent extra gross area.

Among the requested pair/group resistances, angle bearing 528kN is the lowest.

Mechanism detailsSubtract holes on the failure path2 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Gross area counts the complete plate width and thickness.
  2. The highlighted transverse path passes through the bolt holes.
  3. For the straight illustrative path, .

    Staggered paths require their specified correction.

  4. Net area is not always effective area.

    Include the course’s strength ratio or shear-lag rule when applicable.

Result and concise exam wording

Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.

Use the same mechanism: One connected leg does not load both legs equally. Keeping the same gross area does not guarantee the same tension resistance when the connection arrangement changes.

Apply the reasoning to this section’s data and conditions

Pu 350 kN;175 per angle.

ThreeM20 in double shear:551.25kN.

Bolt bearing with centralUCweb 12mm:720kN.

Angle bearing:88kN perbolt perangle, pair 528kN.

Angle effective area 1439.2mm2 less 0.25×568 gives 1297.2; pair tensile 921.012kN.

All four requested strength checks pass; supporting UC strength excluded.

Full detailing still needs the 84mm edge-distance provision reviewed.

Misconceptions and checks

Use the same mechanism: Test every possible fracture cut. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

  • Do not take the UC flange thickness when the bolt passes through its web.
  • Do not confuse two angles with six physical bolts.
  • Deduct one hole from the transverse angle net section.
  • Use the double-bolted coefficient 0.25, not the single-bolted 0.5.

How the method transfers to a new variant

Use the same mechanism: One connected leg does not load both legs equally. Keeping the same gross area does not guarantee the same tension resistance when the connection arrangement changes.

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

  1. Read sectionA–A before counting interfaces.
  2. Allocate the total force to bolts and angle legs.
  3. Compare central and combined outer contact thicknesses.
  4. Compute all angle-bearing bounds.
  5. Build capped effective leg areas and apply the connection-specific reduction.

Prediction with explained answer

Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.

Use the same mechanism: One connected leg does not load both legs equally. Keeping the same gross area does not guarantee the same tension resistance when the connection arrangement changes.

Apply the reasoning to this section’s data and conditions

Prediction and explained answer.

Invented variant: increasePu to 550kN.

Which of the four requested strength modes first fails?

Answer and reasoning

Angle bearing is 528kN<550 and fails.

Bolt shear551.25 kN is a very narrow pass; bolt bearing720 and angle tension921.012 remain higher.

The joint cannot be accepted just because the bolt shear still passes.

Mechanism detailsCount the bolt shear planes3 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Load must cross an interface between the connected plates.
  2. A lap joint gives one shear plane through a bolt.
  3. A symmetric double-cover joint may provide two shear planes.

    Count load-transfer interfaces, not just visible plates.

  4. Use the source’s area and shear strength.

    Then check bearing, plate resistance and detailing separately.