STEELWORK / CON4334
Worked examples

Tutorial 3 Q5: design a beam with a 3m overhang

Diagrams, explanations and answers are presented in reading order. No playback or response is required.
All answers shownChinese–English terminology
Diagrams, explanations and answers are presented in reading order. No playback or response is required.

Select a suitable S355 UB for the source beam: supports at 0 and 7m, free end at 10m; characteristic point loads at 2 and 5m, each dead 60 and imposed 35kN; full-length UDL dead 10 and imposed 5kNm, including beam self-weight. Supports provide torsional restraint, no intermediate lateral support, and effective lengths equal actual segment lengths.

Original source: LectureNotes/Ch 3_Beam.pdf — p. 36, p. 37.

A given value comes from the question or diagram.

A lookup value comes from the named table.

A calculated value follows from the working.

Each assumption is stated where the calculation needs it.

Known information, diagram labels and unknowns

Vertical bending can trigger sideways motion

A beam has enough local bending resistance. Check whether its compression flange can move sideways and twist.

The dashed straight line is the initial reference. The curved flange lines illustrate the labelled sideways movement and twist.
The dashed straight line is the initial reference. The curved flange lines illustrate the labelled sideways movement and twist.

Prediction, then explanation. Adding a valid lateral restraint shortens a stability segment. It need not change the beam’s vertical reaction or moment diagram.

Identify the compressed flange and effective restraints. Calculate the specified slenderness, read buckling strength and compare resistance with the segment demand.

λ=LE/ry,Mb=pbSx  (Class 1/2),mLTMmax≤Mb\lambda=L_E/r_y,\qquad M_b=p_bS_x\;\text{(Class 1/2)},\qquad m_{LT}M_{max}\le M_b

LE and ry use the same length unit. pb uses N/mm²; Sx uses mm³; Mb uses N·mm. mLT is dimensionless.

Scope. Use the specified section class, effective-length branch and loading condition. Load height alone does not prove a destabilizing case.

Check and takeaway. Removing a lateral restraint requires a new segment stability check. The old shorter-segment result cannot establish the longer segment’s adequacy.

Balance the isolated beam

Find the two vertical reactions before calculating internal shear or moment.

A / RₐB / RᵦPaL
A and B are vertical supports. The downward load acts at distance a from A. Its distance from B is L − a.

Prediction, then explanation. Move the same load toward B. Reaction B increases because the load has a larger moment arm about A.

Take moments about A. Reaction A has zero lever arm there. Then use vertical force balance to find reaction A.

RBL=Pa,RA+RB=PR_B L=Pa,\qquad R_A+R_B=P

P, RA and RB are forces in kN. L is support spacing and a is load position, both in m.

Scope. These expressions describe one point load on a simply supported beam. Add other loads through equilibrium; keep their actual positions.

Check and takeaway. Illustration: P = 60 kN, L = 6 m and a = 2 m give RB = 20 kN and RA = 40 kN.

Apply the reasoning to this section’s data and conditions

InputOrigin/type
Characteristic point loadsGiven eachP: dead 60, imposed 35kN; two points total.
Characteristic UDLGiven dead 10, imposed 5kNm over 10m; self-weight included, so do not add the selected mass again.
LTB lengthsGiven actual segment lengths: main span 7,000mm; overhang 3,000mm.
Selected result

533×210×122 UB is a checked trial from the supplied Data File.

It is not claimed to be the globally lightest possible design.

Why this method applies

Use the same mechanism: Vertical bending can trigger sideways motion. Adding a valid lateral restraint shortens a stability segment. It need not change the beam’s vertical reaction or moment diagram.

Use the same mechanism: Balance the isolated beam. Move the same load toward B. Reaction B increases because the load has a larger moment arm about A.

Apply the reasoning to this section’s data and conditions

First solve the full 10m free body; using wL28 for this overhanging beam would be wrong.

Peak sagging lies between the two point loads where shear crosses zero.

The roller also has hogging moment.

After deriving the LTB demand, test a plausible section and reject it if necessary.

For the overhang use conservative mLT=1.

Do not apply a simply supported triangular-moment shortcut to a free end.

1. Factor the actual loads once

A safe beam can still sag too far

Check whether the beam displacement exceeds the permitted service limit.

The straight beam marks the unloaded position. The curved line and vertical arrow show downward displacement, exaggerated for explanation.
The straight beam marks the unloaded position. The curved line and vertical arrow show downward displacement, exaggerated for explanation.

Prediction, then explanation. For the same UDL and stiffness, doubling span multiplies deflection by sixteen. Doubling I halves deflection.

Load bends each beam segment. The curvature accumulates along the span. Material stiffness E and geometric stiffness I resist that deformation.

δmid=5wL4384EI\delta_{mid}=\frac{5wL^4}{384EI}

Use w in N/mm, L in mm, E in N/mm² and I in mm⁴. The resulting midspan deflection is in mm.

Scope. The formula assumes a prismatic, simply supported, linear-elastic beam with full-span UDL. Use the stated service load and deflection limit.

Check and takeaway. A higher yield grade does not automatically increase E. Passing a strength check therefore does not prove acceptable deflection.

Keep load categories separate

A floor carries permanent material and changing occupancy loads. Find the design load for the stated check.

The two boxes show G and Q with their separate factors. The plus sign joins their factored values.
The two boxes show G and Q with their separate factors. The plus sign joins their factored values.

Prediction, then explanation. Increasing imposed load changes its own term. It does not change the dead-load factor or the steel stiffness.

First convert mass to weight where required. Next collect G and Q in compatible units. Apply the combination specified by the course problem.

Wu=1.4G+1.6QW_u=1.4G+1.6Q

G is characteristic dead load; Q is characteristic imposed load. Wu is the design load for this course gravity combination.

Scope. This combination is not universal. Use the specified service load for deflection and the stated factors for other standards or cases.

Check and takeaway. Illustration: G = 10 kN and Q = 5 kN give 22 kN. Factoring their sum by one guessed factor loses the distinction.

Use the same mechanism: Balance the isolated beam. Move the same load toward B. Reaction B increases because the load has a larger moment arm about A.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Why dead and imposed loads stay separate

Keep permanent load and imposed load separate until their respective factors have been applied.

Why dead and imposed loads stay separate — Keep two shopping baskets until their different multipliers are applied.

Sketch, not to scale; use the original dimensions.

  1. Include self-weight and permanent finishes in permanent load.
  2. Include the specified occupancy load in imposed load.
  3. For this course’s stated gravity combination: 1.4G+1.6Q.

Remember: That ULS combination is not the imposed-load deflection load.

Related concept and full method

Each point load: P=1.4×60+1.6×35=84+56=140kNw=1.4×10+1.6×5=14+8=22kNmTotal downward load: 2×140+22×10=500kNFull-length UDL resultant 220kN, acting at distance 102=5m.

Self-weight is already included in dead 10kNm.

All subsequent strength results use these ultimate loads.

The serviceability calculation later returns to imposed 35kN and 5kNm.

Mechanism detailsSee stiffness and deflection3 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Use the specified SLS load, span and support arrangement.

    The demonstrator has a full-span UDL.

  2. The loaded beam bends.

    The deformation is exaggerated so its shape can be seen.

  3. For a simply supported full-span UDL, .

    Double L with w, E and I unchanged: δ becomes 16 times as large.

  4. The readout uses , and .

    Select the finish/support-specific limit from the original table.

2. Reactions, shear and bending over the full beam

Use the same mechanism: Balance the isolated beam. Move the same load toward B. Reaction B increases because the load has a larger moment arm about A.

A cut reveals the internal actions

Find where the beam moment is largest. A large load arrow alone does not locate that point.

The dashed imaginary cut separates two beam pieces. The opposing arrows represent the shear action between those pieces.
The dashed imaginary cut separates two beam pieces. The opposing arrows represent the shear action between those pieces.

Prediction, then explanation. Under a uniform downward load, shear falls steadily. Moment reaches a stationary value where shear becomes zero.

Balance the forces on the cut piece to get V. Balance their moments about the cut to get M. Evaluate each load region separately.

V(x)=RA−wx,M(x)=RAx−wx22V(x)=R_A-wx,\qquad M(x)=R_Ax-\frac{wx^2}{2}

x and L use m; w uses kN/m; V uses kN; M uses kN·m. These lines apply before any point load.

Scope. A point load adds a shear jump. A concentrated couple adds a moment jump. Check load points, supports and overhang roots too.

Check and takeaway. A UDL gives a sloping shear line and a curved moment line. A flat moment diagram therefore cannot represent a loaded UDL region.

Apply the reasoning to this section’s data and conditions

Set A at 0m, support B at 7m, and free end C at 10m. ΣMA=0:7RB−140×2−140×5−220×5=0RB=280+700+1,1007=297.142857kNRA=500−297.142857=202.857143kNx is measured in m, define ⟨x−a⟩=max(x−a,0). M(x)=202.857143x−11x2−140⟨x−2⟩−140⟨x−5⟩+297.142857⟨x−7⟩kN·mV is the slope dMdx, with a jump at each point force.
IntervalShear equation (kN)End shear levels
0<x<2
2<x<5
5<x<7
7<x<10
In the interval 2 to 5m, V=0 gives x=62.85714322=2.857143m. Mmax=202.857143×2.857143−11×2.8571432−140×(2.857143−2)=369.795918kN·mis sagging moment.M(2)=361.714286; M(5)=319.285714kN·m. M(7)=202.857143×7−11×49−140×5−140×2=−99kN·mOverhang: M(x)=−22(10−x)22; M(10)=0. Immediately left of B, |V|max=231.142857kN.

Support reaction 297.142857kN is local bearing demand, not the beam's maximum internal shear.

The shear diagram has four sloping straight segments, with jumps 140, 140, 297.142857kN.

The moment diagram is piecewise parabolic, continuous at point loads, with the above peak and the roller moment −99kN·m.

Mechanism detailsBalance reactions and moments2 concepts · 6 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. This demonstrator is a simply supported 6 m beam with a 60 kN point load.

    It is not the page’s original loading diagram.

  2. .

    Moving the load towards B increases .

  3. .

    The two upward reactions must sum to P.

  4. With the load at midspan, .

    End couples, UDLs and overhangs require their own equilibrium terms.

3. Obtain LTB demand and reject an insufficient trial

Use the same mechanism: Vertical bending can trigger sideways motion. Adding a valid lateral restraint shortens a stability segment. It need not change the beam’s vertical reaction or moment diagram.

Moment shape matters within one segment

Represent a nonuniform moment distribution in the applicable member-buckling equation.

The two diagrams have equal peaks. The left high-moment region is short; the right high-moment region extends across more of the segment.
The two diagrams have equal peaks. The left high-moment region is short; the right high-moment region extends across more of the segment.

Prediction, then explanation. Two segments can have equal peak moment but different distributions. Their equivalent moment factors can therefore differ.

Evaluate moments from the true whole-beam analysis at the required positions. Apply the exact table’s weights, signs and lower bound.

mLT is an LTB factor. mx and my belong to the specified flexural checks. They are not interchangeable.

Scope. Some rules use magnitudes; others require signed ordinates. A factor does not reduce the actual moment used in a local section check.

Check and takeaway. Measure quarter points from the segment start, not automatically from the beam’s left support.

A table value has conditions

Find a design property without mixing a row, column or standard from a different case.

The row and column meet at one cell. The table heading supplies the units and the conditions that give the cell meaning.
The row and column meet at one cell. The table heading supplies the units and the conditions that give the cell meaning.

Prediction, then explanation. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Match the complete section designation. Read the relevant axis and unit. For strength tables, select material, thickness and curve before interpolating.

Given values come from the question. Lookup values come from a named table. Assumed values require an explicit condition.

Scope. A missing row or omitted restraint cannot be recovered from a schematic’s scale. Keep the result conditional when required data are absent.

Check and takeaway. Record the table, row, column and unit beside the substitution. That makes a later check possible.

Apply the reasoning to this section’s data and conditions

There is no lateral restraint at either point load.

The main span is one 7m LTB segment.

Its local quarter positions are 1.75,3.5 and 5.25m, and the maximum magnitude in that segment is 369.795918kN·m.

M2=M(1.75)=202.857143×1.75−11×1.752=321.3125kN·mM3=M(3.5)=202.857143×3.5−11×3.52−140×1.5=365.25kN·mM4=M(5.25)=202.857143×5.25−11×5.252−140×3.25−140×0.25=271.8125kN·mTable 8.4b: mLT=0.2+0.15×321.3125+0.5×365.25+0.15×271.8125369.795918=0.934442>0.44Demand: mLTMmax=345.552934kN·m

Try 533×210×109 UB.

Its large plastic moment capacity is not enough evidence; compute its 7m LTB resistance.

Lookup: Data File pp.9–10, exact 533×210×109 UB row.

Dimensions on p.9; properties on p.10.

D is overall depth.

d is the clear web depth between root fillets, not the nominal designation.

PropertyLookup value / conversion
DimensionsD539.5, web t 11.6, flange T18.8, root r 12.7, clear d 476.5, all mm
Local ratiosbT=5.61;dt=41.1。
Major-axis propertiesIx=66820cm4=6.682×108mm4; Zx=2477cm3; Sx=2828cm3.
LTB propertiesry=4.6cm=46mm; u=0.875; torsional index x=30.9.
S355, flange T=18.8mm, so py=345Nmm2. ε=275345=0.892805. Flange bT=5.61<9ε=8.035248; web in bending dt=41.1<80ε=71.424431. Both are Class 1, so βW=1; plastic bending resistance is permitted.dt=41.1<70ε=62.496377; no shear-buckling calculation is required under the course limit.

Normal-load effective length is the given segment length.

All quantities in λ and λᴸᵀ are dimensionless.

This Class 1 section has βW=1.

λ=LEry=700046=152.173913v=[1+0.05(λx)2]−14=[1+0.05(152.17391330.9)2]−14=0.819921λLT=uvλβW=0.875×0.819921×152.173913×1=109.174285

Table 8.3a, Data File p.5, pᵧ345 column:

105 row gives 128; 110 row gives 119Nmm2. Interpolation fraction: 109.174285−105110−105=0.834857pb=128+0.834857×(119−128)=120.486287Nmm2Mb=pbSx1,000=120.486287×28281,000=340.735220kN·mEquivalent uniform demand: mLTMmax=345.552934kN·mUtilisation: 345.552934340.735220=1.014139Fails.

The trial fails:340.735220<345.552934kN·m.

Choose the next heavier row in this depth series,533×210×122 UB, and re-read all its properties.

Do not reuse the109 kg/m thickness or radius.

Lookup: Data File pp.9–10, exact 533×210×122 UB row.

Dimensions on p.9; properties on p.10.

D is overall depth.

d is the clear web depth between root fillets, not the nominal designation.

PropertyLookup value / conversion
DimensionsD544.5, web t 12.7, flange T21.3, root r 12.7, clear d 476.5, all mm
Local ratiosbT=4.97;dt=37.5。
Major-axis propertiesIx=76040cm4=7.604×108mm4; Zx=2793cm3; Sx=3196cm3.
LTB propertiesry=4.67cm=46.7mm; u=0.877; torsional index x=27.6.
S355, flange T=21.3mm, so py=345Nmm2. ε=275345=0.892805. Flange bT=4.97<9ε=8.035248; web in bending dt=37.5<80ε=71.424431. Both are Class 1, so βW=1; plastic bending resistance is permitted.dt=37.5<70ε=62.496377; no shear-buckling calculation is required under the course limit.

Mechanism detailsA beam bends sideways and twists3 concepts · 23 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. For the illustrated sagging beam the top flange is compressed.
  2. The unrestrained compression flange can move sideways while the complete cross-section twists.
  3. Only effective restraints divide the member into unbraced segments.

    They do not automatically add vertical supports.

  4. Use the segment effective length, section properties and matching moment factor.

    This is an exaggerated mode shape, not a calculated displacement.

4. Check both segments of the selected 533×210×122 UB

Use the same mechanism: Vertical bending can trigger sideways motion. Adding a valid lateral restraint shortens a stability segment. It need not change the beam’s vertical reaction or moment diagram.

Use the same mechanism: Moment shape matters within one segment. Two segments can have equal peak moment but different distributions. Their equivalent moment factors can therefore differ.

Move between two known values

The required slenderness lies between two table rows. Estimate the strength on the straight segment between those rows.

xy(70, 200)(74, 192)(80, 180)70748040% of input interval → 40% of output change
The marked position lies partway along the horizontal interval. Use the same fraction of the vertical change.

Prediction, then explanation. If the second strength is lower, moving toward that row must reduce the interpolated strength.

Subtract the lower input to find distance travelled. Divide by the input interval. Multiply that fraction by the output change.

f=x−x0x1−x0,y=y0+f(y1−y0)f=\frac{x-x_0}{x_1-x_0},\qquad y=y_0+f(y_1-y_0)

x is the required input. The two known pairs are (x₀, y₀) and (x₁, y₁). f has no unit.

Scope. Use one table, curve and strength column. This interpolation does not permit extrapolation or inventing an intermediate steel section.

Check and takeaway. Illustration: between strengths 200 and 180, a fraction of 0.4 gives 192 N/mm². The result lies between both endpoints.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Why the shape of the moment diagram matters

The same peak moment is more demanding when a long region stays near that peak.

Why the shape of the moment diagram matters — The same peak moment is more demanding when a long region stays near that peak.

Sketch, not to scale; use the original dimensions.

  1. Use the diagram of this unrestrained segment.
  2. Choose the applicable course sketch or quarter-point rule.
  3. Apply its factor to the demand, following the stated check.

Remember: Column flexural-buckling factors and LTB factors are not interchangeable.

Related concept and full method

Main 7m span: use the same load-derived demand but the new section properties.

Normal-load effective length is the given segment length.

All quantities in λ and λᴸᵀ are dimensionless.

This Class 1 section has βW=1.

λ=LEry=700046.7=149.892934v=[1+0.05(λx)2]−14=[1+0.05(149.89293427.6)2]−14=0.797293λLT=uvλβW=0.877×0.797293×149.892934×1=104.808994

Table 8.3a, Data File p.5, pᵧ345 column:

100 row gives 137; 105 row gives 128Nmm2. Interpolation fraction: 104.808994−100105−100=0.961799pb=137+0.961799×(128−137)=128.343811Nmm2Mb=pbSx1,000=128.343811×31961,000=410.186820kN·mEquivalent uniform demand: mLTMmax=345.552934kN·mUtilisation: 345.552934410.186820=0.842428Passes.

Overhang 3m: its maximum hogging magnitude is 99kN·m at B.

Use conservative mLT=1, hence demand 99kN·m.

The problem expressly permits effective length equal to the actual 3m.

Do not silently impose a different cantilever factor.

Normal-load effective length is the given segment length.

All quantities in λ and λᴸᵀ are dimensionless.

This Class 1 section has βW=1.

λ=LEry=300046.7=64.239829v=[1+0.05(λx)2]−14=[1+0.05(64.23982927.6)2]−14=0.941835λLT=uvλβW=0.877×0.941835×64.239829×1=53.061400

Table 8.3a, Data File p.5, pᵧ345 column:

50 row gives 285; 55 row gives 268Nmm2. Interpolation fraction: 53.061400−5055−50=0.612280pb=285+0.612280×(268−285)=274.591241Nmm2Mb=pbSx1,000=274.591241×31961,000=877.593606kN·mEquivalent uniform demand: mLTMmax=99.000000kN·mUtilisation: 99.000000877.593606=0.112808Passes.

Both selected-section LTB checks pass.

Restraint at B must be effective for the specified hogging/compression-flange condition.

The question grants the torsional restraint model.

Mechanism detailsA beam bends sideways and twists4 concepts · 7 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. For the illustrated sagging beam the top flange is compressed.
  2. The unrestrained compression flange can move sideways while the complete cross-section twists.
  3. Only effective restraints divide the member into unbraced segments.

    They do not automatically add vertical supports.

  4. Use the segment effective length, section properties and matching moment factor.

    This is an exaggerated mode shape, not a calculated displacement.

5. Local strength, imposed-load deflection and remaining scope

The web carries the shear check

Compare the applied shear with the resistance of the prescribed shear area.

At the imaginary cut, opposing arrows resist relative sliding. The rolled-UB calculation below assigns the shear area to the web.
At the imaginary cut, opposing arrows resist relative sliding. The rolled-UB calculation below assigns the shear area to the web.

Prediction, then explanation. At fixed design strength and depth, increasing web thickness increases this shear resistance.

Calculate the prescribed shear area. Multiply by the design shear stress from the course rule. Then compare matching force units.

Av=Dt,Vc=pyAv/3A_v=Dt,\qquad V_c=p_yA_v/\sqrt{3}

D is overall depth; t is web thickness, in mm. Av uses mm². py uses N/mm², giving Vc in N.

Scope. Apply this area definition to the stated rolled section. Check web slenderness separately. The factor 0.6 is the low-shear threshold, not this resistance coefficient.

Check and takeaway. A shear pass alone does not prove bending, deflection or local support-web adequacy.

Internal tension and compression resist moment

Find which section resistance applies before comparing it with the moment demand.

In sagging bending, the upper region compresses and the lower region stretches. Together their forces form a resisting couple.
In sagging bending, the upper region compresses and the lower region stretches. Together their forces form a resisting couple.

Prediction, then explanation. A larger appropriate section modulus raises resistance at fixed strength. Local plate buckling can restrict the usable modulus.

Classify the section first. At low shear, use the elastic expression for Class 3 or the prescribed capped plastic expression for Classes 1 and 2.

Mc=min⁡(pyS,1.2pyZ)for Class 1/2 at low shearM_c=\min(p_yS,1.2p_yZ)\quad\text{for Class 1/2 at low shear}

py uses N/mm². S is plastic modulus and Z is elastic modulus, both in mm³. Mc then uses N·mm.

Scope. This is section resistance, not whole-member LTB resistance. High shear and Class 4 require their appropriate treatment.

Check and takeaway. Selecting the larger of the two capped terms defeats the cap. Use their minimum.

Shear and bending share the web

Decide whether the unreduced bending resistance remains applicable at the section being checked.

The same web region participates in shear and longitudinal bending stress. The two demands must be evaluated at one section.
The same web region participates in shear and longitudinal bending stress. The two demands must be evaluated at one section.

Prediction, then explanation. Raising shear beyond the specified threshold can reduce available bending resistance. A distant maximum shear is not the coexistent shear.

Find the moment-check position. Evaluate the shear there. Compare it with the low-shear threshold before selecting the resistance expression.

V≤0.6Vcis the course low-shear conditionV\le0.6V_c\quad\text{is the course low-shear condition}

V is shear at the checked section; Vc is its shear resistance. Both use the same force unit.

Scope. Above the threshold, use the supplied reduction expression. The threshold itself is not a substitute resistance formula.

Check and takeaway. If the maximum shear anywhere is below the threshold, all sections satisfy that low-shear condition. Otherwise check the actual positions.

Apply the reasoning to this section’s data and conditions

Physical interpretation: How much does the beam sag?

Strength asks whether it fails; deflection asks how far it moves.

How much does the beam sag? — Strength asks whether it fails; deflection asks how far it moves.

Sketch, not to scale; use the original dimensions.

  1. Use the serviceability load case specified by the course question.
  2. Choose the expression matching the support and load positions.
  3. Use consistent units for load, length, E and I.

Remember: The largest deflection is not always at midspan.

Related concept and full method

Av=tD=12.7×544.5=6915.15mm2Vc=pyAv3=345×6915.153×1,000=1377.399981kNVmax=231.142857kN<Vc: shear passes.0.6Vc=826.439989kN>Vmax; even peak shear is low, so low-shear bending applies throughout.Mc=min(pySx,1.2pyZx)=min(345×31961,000,1.2×345×27931,000)=min(1102.62,1156.3)=1102.62kN·m|M|max=369.795918kN·m: bending passes.

Serviceability uses each imposed point load P=35,000N, q=5Nmm.

Treat the whole beam as a continuous elastic member passing over two simple supports.

A fixed-cantilever formula would omit rotation of the section at the roller.

Imposed-load reaction: RB,q=35×2+35×5+50×57=70.714286kNRA,q=120−70.714286=49.285714kNE=205,000Nmm2; I=76,040×104mm4. EI=155,882,000,000,000N·mm2

Take downward deflection v positive, x in mm.

Integrating EIv″=−M twice gives the following expression.

The support atx 0 forces the constant displacement term to zero; v(7,000)=0 determines the remaining constant C.

EIv=Cx−49,285.714286x36+5x424+35,000⟨x−2,000⟩36+35,000⟨x−5,000⟩36−70,714.285714⟨x−7,000⟩36In the interval x=7,000: C=[49,285.714286×7,00036−5×7,000424−35,000×5,00036−35,000×2,00036]7,000=[2.8175×1015−5.002083333×1014−7.291666667×1014−4.666666667×1013]7,000=2.202083333×1011N·mm2

Differentiate once and set slope to zero in each interval.

The only internal stationary deflection along the beam is in 2,000<x<5,000mm, where only the first point-load bracket is active:

EIv′=C−49,285.714286x22+5x36+35,000(x−2,000)22=0Collecting like terms:56x3−7,142.857143x2−70,000,000x+290,208,333,333.333=0Root within the applicable interval:x=3,426.666453mmSubstitute into EIv to obtain maximum downward deflection v=3.013388mm. v(0)=v(7,000)=0v(10,000)=−3.408027mmThe free end moves upwards. The other intervals have no internal zero-slope root; their boundaries must still be checked. Even the stricter main-span limit for brittle finishes, 7,000360=19.444444mm, is satisfied. Overhang limit 3,000180=16.666667mm; |−3.408027|<16.666667.

The source does not specify finishes.

Demonstrating the stricter span limit avoids inventing a finish type.

Loading on the main span rotates the support section.

Therefore, the free end can move upwards.

This calculation covers the simultaneous load pattern drawn.

It does not claim an envelope from separate imposed-load patterns.

Mechanism detailsSee shear in the web4 concepts · 9 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Internal shear keeps the two sides of the cut in vertical equilibrium.
  2. For the course’s common I-section case, the web provides the principal shear area.

    Use the specified definition.

  3. A slender web may require a different shear-buckling route before a simple shear-resistance formula is used.
  4. Use where applicable in the course.

    Convert N to kN before comparing with design shear.

Lecturer's answer

ItemLecturer's value
Trial section610×229×113 UB, py=345p_y=345
Loads (self-weight neglected)P=1.4×60+1.6×35=140 kNP=1.4\times60+1.6\times35=140\text{ kN}, w=1.4×10+1.6×5=22 kN/mw=1.4\times10+1.6\times5=22\text{ kN/m}
Case 1: AB fully loaded, BC at 1.0 × dead loadMmax⁡=393.3M_{\max}=393.3, mLT=0.946m_{LT}=0.946, demand 372 kN⋅m372\text{ kN·m}
Case 2: all spans fully loadedV=231.1 kN<Vc=1343 kNV=231.1\text{ kN}<V_c=1343\text{ kN}, MB=−99 kN⋅mM_B=-99\text{ kN·m}
Segment AB (7 m)λLT=109\lambda_{LT}=109, pb=121p_b=121, Mb=397>372 kN⋅mM_b=397>372\text{ kN·m}
Cantilever BC (3 m)pb=278p_b=278, Mb=912.8>1.0×99 kN⋅mM_b=912.8>1.0\times99\text{ kN·m}

Conclusion: 610×229×113 UB is adequate. Use pattern loading for segment AB (Case 1) and full loading for the cantilever (Case 2).

Source: Lecturer's tutorial solution, Ch 3, pp. 13–17.

Result and concise exam wording

Use the same mechanism: A safe beam can still sag too far. For the same UDL and stiffness, doubling span multiplies deflection by sixteen. Doubling I halves deflection.

Use the same mechanism: Vertical bending can trigger sideways motion. Adding a valid lateral restraint shortens a stability segment. It need not change the beam’s vertical reaction or moment diagram.

Apply the reasoning to this section’s data and conditions

P140 kN,w 22 kN/m; RA202.857143,RB297.142857 kN.

Peak internal shear 231.142857kN; saggingM369.795918 kNm atx 2.857143 m, hogging−99 atB.

Main-span LTB demand 345.552934kN·m.

Trial 533×210×109 fails(Mb 340.735220); select 533×210×122: mainMb 410.186820, overhangMb 877.593606 kNm with conservative overhangmLT1.

ShearVc 1377.400 kN and Mc 1102.620 kNm pass.

Imposed deflection 3.013388mm downward in span and 3.408027mm upward at tip.

Bearing/local-web detail checks remain incomplete because source inputs are absent.

Lecturer's method (pattern loading): AB fully loaded, BC at 1.0 × dead load: Mmax⁡=393.2M_{\max}=393.2, mLT=0.946m_{LT}=0.946, demand 371.8<410.2 kN⋅m371.8<410.2\text{ kN·m}; the 533×210×122 UB still passes.

Misconceptions and checks

Use the same mechanism: A safe beam can still sag too far. For the same UDL and stiffness, doubling span multiplies deflection by sixteen. Doubling I halves deflection.

Use the same mechanism: Vertical bending can trigger sideways motion. Adding a valid lateral restraint shortens a stability segment. It need not change the beam’s vertical reaction or moment diagram.

Use the same mechanism: Balance the isolated beam. Move the same load toward B. Reaction B increases because the load has a larger moment arm about A.

Apply the reasoning to this section’s data and conditions

  • Do not read the upper 5m dimension as distance to the roller.
  • Do not add self-weight again.
  • Do not use the support reaction as the maximum beam internal shear.
  • Do not split LTB length at an unrestrained point load.
  • Do not use a fixed-cantilever deflection formula for a rotating support.

How the method transfers to a new variant

Find which plate buckles first

Before using plastic bending resistance, check whether the flange and web can sustain the required stress distribution.

The short waves are local plate buckling. They differ from sideways movement of the whole member.
The short waves are local plate buckling. They differ from sideways movement of the whole member.

Prediction, then explanation. At fixed width, a thinner plate has a larger width-to-thickness ratio. Local buckling then becomes more restrictive.

Calculate the flange and web ratios separately. Compare each with the limits for its stress condition. The worse class governs.

ε=275/py\varepsilon=\sqrt{275/p_y}

py is the design yield strength in N/mm². ε is a dimensionless scale used in the supplied classification limits.

Scope. Pure bending and uniform compression use different web limits. Class 2 allows plastic resistance but not the Class 1 rotation capability.

Check and takeaway. A Class 1 web and Class 2 flange give a Class 2 section. Do not average the class numbers.

Use the same mechanism: Moment shape matters within one segment. Two segments can have equal peak moment but different distributions. Their equivalent moment factors can therefore differ.

Use the same mechanism: A safe beam can still sag too far. For the same UDL and stiffness, doubling span multiplies deflection by sixteen. Doubling I halves deflection.

Apply the reasoning to this section’s data and conditions

  1. Name supports and load positions using the source dimension chains.
  2. Choose a sign convention; include applied couples in moment equilibrium.
  3. Find reactions, then piecewise shear and bending moment.
  4. Locate extrema where shear is zero and at load/support discontinuities.
  5. Divide only at actual effective lateral restraints; classify and read the exact section row.
  6. Calculate segment moment factors and LTB resistance, retaining UDL curvature where present.
  7. Check shear, local bending and serviceability; state any missing bearing/detail inputs.

Prediction with explained answer

Ask two separate design questions

Decide whether the check concerns failure or unacceptable behaviour during use.

The strength branch compares demand with resistance. The service branch compares displacement with its specified limit.
The strength branch compares demand with resistance. The service branch compares displacement with its specified limit.

Prediction, then explanation. A larger section may improve both results, but a pass on one branch does not prove a pass on the other.

ULS addresses relevant strength and stability failure modes. SLS addresses specified service conditions such as deflection.

demand≤resistance,δ≤δlimit\text{demand}\le\text{resistance},\qquad\delta\le\delta_{limit}

δ is the calculated displacement; δlimit is the permitted displacement. Both must use the same length unit.

Scope. Use each check’s own load combination and limit. A strength load factor does not change the physical stiffness.

Check and takeaway. Write separate conclusions for strength, stability and serviceability where requested. A single unexplained “safe” hides those distinctions.

Apply the reasoning to this section’s data and conditions

Prediction and explained answer.

Invented variant: can the rejected 533×210×109 section be accepted by rounding its 340.735kN·m resistance to 350kN·m?

Answer and reasoning

No. The demand 345.553kN·m exceeds the unrounded resistance 340.735kN·m by 4.818kN·m, a utilisation of about 1.01414.

Rounding must not change a failed limit-state check into a pass.

Change the section or restraint arrangement and recalculate.