Design welds connecting a bracket cut from 533×210×82 UB S355 to a column. Ultimate vertical load is 600kN at eccentricity 250mm. Use Class 42 electrode and the question’s assumption that flange welds resist moment while web welds resist shear.

Original source: LectureNotes/Ch 2_Connection.pdf — p. 45, p. 48.

A given value comes from the question or diagram.

A lookup value comes from the named table.

A calculated value follows from the working.

Each assumption is stated where the calculation needs it.

Known information, diagram labels and unknowns

A force couple carries moment

Separate the force couple used to carry moment from the force used to carry web shear.

The flange forces act in opposite directions. Their separation z gives the lever arm. The web arrow represents shear.
The flange forces act in opposite directions. Their separation z gives the lever arm. The web arrow represents shear.

Prediction, then explanation. For the same moment, a larger lever arm requires a smaller couple force. It does not remove the web shear.

Moment is force multiplied by perpendicular separation. Divide the required moment by the specified separation to obtain each couple force.

F=M/zF=M/z

M is moment in kN·mm; z is the specified force-line separation in mm; F is force in kN.

Scope. Use the lever arm defined by the source model. Do not silently replace it with overall section depth or another geometric distance.

Check and takeaway. Check flange welds for the couple forces and web welds for the stated shear model. Both force paths need a satisfactory detail.

The weld resists through its throat

Convert a visible fillet leg into resistance per effective length.

The two outer sides are the legs. The shorter perpendicular line through the ideal triangle is the throat.
The two outer sides are the legs. The shorter perpendicular line through the ideal triangle is the throat.

Prediction, then explanation. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

For the course right-angle equal-leg fillet, take throat as 0.7 times leg. Multiply throat area per unit length by weld strength.

a=0.7s,qcap=0.7spw/1000a=0.7s,\qquad q_{cap}=0.7sp_w/1000

s and a are leg and throat in mm. pw is weld strength in N/mm². qcap is resistance in kN/mm.

Scope. Use effective length, the correct steel/electrode strength and permitted leg limits. Full-penetration butt welds use a different model.

Check and takeaway. Illustration: a 6 mm leg at 250 N/mm² gives 0.7(6)(250)/1000=1.05 kN/mm0.7(6)(250)/1000=1.05\,\mathrm{kN/mm}.

A table value has conditions

Find a design property without mixing a row, column or standard from a different case.

The row and column meet at one cell. The table heading supplies the units and the conditions that give the cell meaning.
The row and column meet at one cell. The table heading supplies the units and the conditions that give the cell meaning.

Prediction, then explanation. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Match the complete section designation. Read the relevant axis and unit. For strength tables, select material, thickness and curve before interpolating.

Given values come from the question. Lookup values come from a named table. Assumed values require an explicit condition.

Scope. A missing row or omitted restraint cannot be recovered from a schematic’s scale. Keep the result conditional when required data are absent.

Check and takeaway. Record the table, row, column and unit beside the substitution. That makes a later check possible.

Apply the reasoning to this section’s data and conditions

InputMeaning
Moment force coupleUse the source example’s overall-depth lever-arm approximation D=528.3mm between flange force lines.
Flange runOne 190mm physical weld line at each flange, carrying the flange couple force.
Web runsTwo 340mm physical runs share 600kN direct shear.
Section thicknessData File p.9 row 533×210×82: flange 13.2mm,web 9.6mm.
Unspecified input

Column flange thickness is absent, affecting the minimum permitted weld size at the web/column joint.

The strength design can be calculated; unconditional detailing depends on that thickness.

Why this method applies

Treat a weld group as lines

An eccentric force creates direct line force and torsional line force in the same weld group.

The four perimeter lines represent weld runs. The interior label says No weld here: the enclosed plate area is not weld length.
The four perimeter lines represent weld runs. The interior label says No weld here: the enclosed plate area is not weld length.

Prediction, then explanation. Increasing eccentricity increases the torsional contribution. The governing corner depends on vector addition, not distance alone.

Find the line centroid. Integrate squared distance along the effective lines. Add direct and torsional components at every candidate critical point.

J=∫r2 dl,qMx=−My/J,qMy=Mx/JJ=\int r^2\,dl,\qquad q_{Mx}=-My/J,\quad q_{My}=Mx/J

J is line polar inertia in mm³. x and y use mm. With M in kN·mm, q is line force in kN/mm.

Scope. A solid rectangle has area inertia in mm⁴ and is not this weld-line model. Missing weld sides change the centroid and integrals.

Check and takeaway. Compare the largest resultant line force with the selected throat resistance. Keep kN/mm distinct from total force in kN.

Use the same mechanism: A force couple carries moment. For the same moment, a larger lever arm requires a smaller couple force. It does not remove the web shear.

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

Use the stated simplified load split rather than a full elastic weld-group analysis.

Moment M=Pe becomes an equal-and-opposite pair of flange forces MD.

The web takes the vertical shear.

Size each family of welds using its own effective length.

Because Leff=L−2s, changing the leg also changes the effective length; recheck the chosen trial.

1. Moment and flange welds

Use the same mechanism: A force couple carries moment. For the same moment, a larger lever arm requires a smaller couple force. It does not remove the web shear.

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

Physical interpretation: How two flange forces make a moment

Two opposite forces form a turning pair, like two hands turning a wheel.

How two flange forces make a moment — Two opposite forces form a turning pair, like two hands turning a wheel.

Sketch, not to scale; use the original dimensions.

  1. Identify the separation between their actual force lines.
  2. Required force equals moment divided by that separation.
  3. Design the relevant flange group for that force.

Remember: The force-line separation is not automatically the overall section depth.

Related concept and full method

M=600×250=150,000kN·mm=150kN·mFlange force: F=MD=150,000528.3=283.929585kNFor trial weld leg s, resistance per flange weld: (190−2s)×0.175skNTrial 8mm: effective length 174mm,q=1.4kNmm, resistance 243.6kN, fails. Trial 9mm: effective length 172mm,q=1.575kNmm, resistance 270.9kN, fails. Trial 10mm: effective length 170mm,q=1.75kNmm, resistance 297.5kN>283.929585kN: passes.

Provide 10mm fillet along each 190mm flange run.

For 13.2mm flange edge, maximum leg 13.2−2=11.2mm permits 10.

The thicker-part minimum is at most 8mm in the supplied table, so 10 meets it even if the column flange is thicker.

Effective 170≥max(4×10,40)=40mm.

The force in each flange is 283.93kN.

Do not divide it by two merely because the couple has two flanges.

This MD force-couple idealization is explicitly tied to the lecturer’s corresponding bracket method.

A refined connection analysis would establish the actual flange force resultants.

The nominal 528.3mm lever arm is not a newly measured weld-centroid separation.

Mechanism detailsSeparate the moment couple and shear3 concepts · 3 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. A simplified moment connection assigns different actions to different fastener groups.
  2. Opposite flange forces separated by z resist moment: .
  3. The web fasteners or welds carry the assigned vertical shear in this model.
  4. Flange force, web shear, plate bearing and detailing each need their specified checks.

2. Web shear welds and detailing condition

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Use the same mechanism: A force couple carries moment. For the same moment, a larger lever arm requires a smaller couple force. It does not remove the web shear.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Why the weld throat is smaller than its leg

The shortest cut through the weld is thinner than the outside leg.

Why the weld throat is smaller than its leg — The shortest cut through the weld is thinner than the outside leg.

Sketch, not to scale; use the original dimensions.

  1. For the stated equal-leg 90° fillet, throat is approximately 0.7 × leg.
  2. Multiply throat area by the matching weld design strength.
  3. For force per length, use a one-millimetre weld strip.

Remember: Choose strength from both the steel grade and electrode class.

Related concept and full method

Two web welds share V=600kN, each taking 300kN. Trial 5mm: effective length per weld 340−10=330mm; combined resistance 2×330×0.175×5=577.5kN, fails. Trial 6mm: effective length per weld 340−12=328mm; combined resistance 2×328×0.175×6=688.8kN>600kN, passes. Resistance per weld 328×1.05=344.4kN>300kN. Effective length 328≥max(4×6,40)=40mm. Maximum weld leg at the web edge 9.6−2=7.6mm, so 6mm satisfies this cap.

The 6mm web weld meets the thicker-part minimum if the column flange thickness is at most 19mm under the supplied table.

If it exceeds 19mm, the minimum would be 8mm, incompatible with the 7.6mm edge maximum in this edge-detail model.

A different detail would be needed.

Since column flange thickness is not stated, report 6mm as the completed strength selection with this explicit detailing condition, not an unconditional fabrication approval.

Provide any required end returns of at least 2s where the actual joint permits; their geometry is not dimensioned here.

Mechanism detailsFrom fillet leg to effective throat2 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat .

    It is shorter than the leg.

  3. Effective resisting area = .

    With here, capacity per length is .

  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.

Lecturer's answer

ItemLecturer's value
Flange welds (moment)FT=600×250528.3×(190−2×10)=1.67 kN/mmF_T=\dfrac{600\times250}{528.3\times(190-2\times10)}=1.67\text{ kN/mm} → s=9.5 mms=9.5\text{ mm}
Web welds (shear)Fs=6002×(340−2×6)=0.91 kN/mmF_s=\dfrac{600}{2\times(340-2\times6)}=0.91\text{ kN/mm} → s=5.2 mms=5.2\text{ mm}

Conclusion: Use 10 mm fillet welds on the flanges and 6 mm fillet welds on the web.

Source: Lecturer's tutorial solution, Ch 2, p. 8.

Result and concise exam wording

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

M150 kNm; source lever arm 528.3mm gives flange force 283.9296kN.

Use 10mm flange fillets on 190mm runs: effective 170mm, capacity 297.5kN each.

For web shear use 6mm fillets on two 340mm runs: effective 328mm each, pair capacity 688.8 kN>600.

Web minimum-size compliance remains conditional on the omitted column flange thickness (6mm selection permitted by the supplied minimum table only up to 19mm thicker part).

Misconceptions and checks

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

  • Use the given 190mm weld run rather than nominal 210mm section width.
  • Each flange carries the full couple force.
  • Use both web runs for shear, but deduct 2s from each.
  • Do not claim an omitted column thickness has been checked.

How the method transfers to a new variant

Use the same mechanism: A force couple carries moment. For the same moment, a larger lever arm requires a smaller couple force. It does not remove the web shear.

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

  1. Factor loads if required, then calculate Pe.
  2. Convert moment into flange force using the stated force-couple model.
  3. Try flange leg sizes and update each effective length.
  4. Size the pair of web welds for the full shear force.
  5. Check known maximum/minimum size and length conditions; state missing detailing inputs.

Prediction with explained answer

Use the same mechanism: A force couple carries moment. For the same moment, a larger lever arm requires a smaller couple force. It does not remove the web shear.

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Keep load categories separate

A floor carries permanent material and changing occupancy loads. Find the design load for the stated check.

The two boxes show G and Q with their separate factors. The plus sign joins their factored values.
The two boxes show G and Q with their separate factors. The plus sign joins their factored values.

Prediction, then explanation. Increasing imposed load changes its own term. It does not change the dead-load factor or the steel stiffness.

First convert mass to weight where required. Next collect G and Q in compatible units. Apply the combination specified by the course problem.

Wu=1.4G+1.6QW_u=1.4G+1.6Q

G is characteristic dead load; Q is characteristic imposed load. Wu is the design load for this course gravity combination.

Scope. This combination is not universal. Use the specified service load for deflection and the stated factors for other standards or cases.

Check and takeaway. Illustration: G = 10 kN and Q = 5 kN give 22 kN. Factoring their sum by one guessed factor loses the distinction.

Apply the reasoning to this section’s data and conditions

Prediction and explained answer.

Invented variant: ultimate load remains 600kN but its eccentricity rises to 300mm.

Can the selected flange weld remain 10mm?

Answer and reasoning

F=600×300528.3=340.7155kN, above the 10mm weld resistance 297.5kN.

The web shear remains 600kN.

Therefore, its strength demand is unchanged.

A larger flange weld is limited by the 13.2−2=11.2mm edge maximum; even 11mm gives(190−22)×1.925=323.4kN, still insufficient.

A changed flange weld layout/detail is needed.

Mechanism detailsSeparate the moment couple and shear2 concepts · 3 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. A simplified moment connection assigns different actions to different fastener groups.
  2. Opposite flange forces separated by z resist moment: .
  3. The web fasteners or welds carry the assigned vertical shear in this model.
  4. Flange force, web shear, plate bearing and detailing each need their specified checks.