STEELWORK / CON4334
Worked examples

Tutorial 2 Q5: double-angle weld design and a conflicting size rule

Diagrams, explanations and answers are presented in reading order. No playback or response is required.
All answers shownChinese–English terminology
Diagrams, explanations and answers are presented in reading order. No playback or response is required.

Design the welds for two 65×50×6 unequal angles carrying 350kN ultimate tension, with their longer sides connected to a 12mm gusset. Use S355 and Class 42 electrode, and check angle tension resistance.

Original source: LectureNotes/Ch 2_Connection.pdf — p. 45, p. 47.

A given value comes from the question or diagram.

A lookup value comes from the named table.

A calculated value follows from the working.

Each assumption is stated where the calculation needs it.

Known information, diagram labels and unknowns

One connected leg does not load both legs equally

An angle carries tension through only one leg. Determine how much section area the design rule permits.

The force enters the connected leg first. The outstanding leg receives force through the angle corner and adjoining material.
The force enters the connected leg first. The outstanding leg receives force through the angle corner and adjoining material.

Prediction, then explanation. Keeping the same gross area does not guarantee the same tension resistance when the connection arrangement changes.

Separate connected and outstanding leg areas. Include the actual holes. Then use the supplied single-angle or double-angle effective-area rule.

Pt=pyAeP_t=p_yA_e

Ae is the effective area from the applicable angle rule in mm². py is the relevant design strength in N/mm².

Scope. Do not assume the whole gross area is effective. Symmetry, connected leg and connection type determine which rule applies.

Check and takeaway. The outstanding leg contributes through load transfer; the rule need not either count all of it or discard all of it.

The weld resists through its throat

Convert a visible fillet leg into resistance per effective length.

The two outer sides are the legs. The shorter perpendicular line through the ideal triangle is the throat.
The two outer sides are the legs. The shorter perpendicular line through the ideal triangle is the throat.

Prediction, then explanation. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

For the course right-angle equal-leg fillet, take throat as 0.7 times leg. Multiply throat area per unit length by weld strength.

a=0.7s,qcap=0.7spw/1000a=0.7s,\qquad q_{cap}=0.7sp_w/1000

s and a are leg and throat in mm. pw is weld strength in N/mm². qcap is resistance in kN/mm.

Scope. Use effective length, the correct steel/electrode strength and permitted leg limits. Full-penetration butt welds use a different model.

Check and takeaway. Illustration: a 6 mm leg at 250 N/mm² gives 0.7(6)(250)/1000=1.05 kN/mm0.7(6)(250)/1000=1.05\,\mathrm{kN/mm}.

Apply the reasoning to this section’s data and conditions

InputSource/type
Angle geometry

Given 65×50×6, two angles.

For course rectangular leg areas split the shared corner equally between the two legs.

Centroid

Data File p.12, 65×50 row, t=6: measured from the heel along the long leg, while cx=2.04cm=20.4mm.

cy=1.30cm is the perpendicular coordinate.

Force shareSymmetric two-angle connection: each angle carries 3502=175kN.
Weld resistance

The original website summary writes pv, whereas course weld calculations use pw.

This explanation explicitly uses the latter.

For S355/Class 42, pw=250Nmm2.

The strength model uses only side welds and conservatively ignores the short transverse heel-end weld shown.

Size limitsThicker joined part 12mm → source minimum 5mm; angle edge 6mm → maximum 6−2=4mm.

Why this method applies

Unequal lever arms require unequal forces

Two longitudinal welds must transfer a tensile force through the angle centroid without an unintended moment.

The force line lies between welds. Each weld has its own perpendicular distance from that line.
The force line lies between welds. Each weld has its own perpendicular distance from that line.

Prediction, then explanation. The weld with the shorter lever arm must carry more force to balance the longer-arm weld’s moment.

Use force balance and moment balance together. Then divide each force by its own line resistance to find required effective length.

F1+F2=P,F1z1=F2z2F_1+F_2=P,\qquad F_1z_1=F_2z_2

P, F₁ and F₂ are forces. z₁ and z₂ are perpendicular distances from the load line. Use consistent length units.

Scope. Equal force shares apply only to the symmetric case. Physical terminated weld length also needs the supplied end deductions.

Check and takeaway. If the two lever arms become equal, the equations return equal forces. That limiting case checks the force distribution.

Use the same mechanism: One connected leg does not load both legs equally. Keeping the same gross area does not guarantee the same tension resistance when the connection arrangement changes.

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

First check whether the angle pair can carry the force after the course shear-lag reduction.

Then design unequal side-weld lengths so the weld resultant passes through each angle’s centroid.

Finally check that the chosen leg is permitted by both minimum and maximum rules.

In this particular detail those rules conflict; strength sizing alone cannot produce an acceptable final fillet-weld detail.

1. Check the two angles in tension

Use the same mechanism: One connected leg does not load both legs equally. Keeping the same gross area does not guarantee the same tension resistance when the connection arrangement changes.

A table value has conditions

Find a design property without mixing a row, column or standard from a different case.

The row and column meet at one cell. The table heading supplies the units and the conditions that give the cell meaning.
The row and column meet at one cell. The table heading supplies the units and the conditions that give the cell meaning.

Prediction, then explanation. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Match the complete section designation. Read the relevant axis and unit. For strength tables, select material, thickness and curve before interpolating.

Given values come from the question. Lookup values come from a named table. Assumed values require an explicit condition.

Scope. A missing row or omitted restraint cannot be recovered from a schematic’s scale. Keep the result conditional when required data are absent.

Check and takeaway. Record the table, row, column and unit beside the substitution. That makes a later check possible.

Apply the reasoning to this section’s data and conditions

Physical interpretation: One connected leg does not load both legs equally

The connected leg receives the pull first.

The other leg receives it through the angle.

One connected leg does not load both legs equally — The connected leg receives the pull first; the other leg receives it through the angle.

Sketch, not to scale; use the original dimensions.

  1. Identify connected and outstanding legs from the drawing.
  2. Use the relevant bolted or welded angle rule.
  3. Keep the lecturer’s area convention consistent.

Remember: Bolted and welded reduction expressions are not the same rule.

Related concept and full method

Connected-leg area per angle: a1=(65−62)×6=62×6=372mm2Outstanding-leg area: a2=(50−62)×6=47×6=282mm2A=a1+a2=654mm2There is no bolt-hole deduction. The course reduction factor for welded double angles is 0.15. Effective tension area per angle: A−0.15a2=654−0.15×282=611.7mm2T=6mm, so py=355Nmm2. Per angle: Pt=611.7×3551,000=217.1535kNDouble angles: Pt=2×217.1535=434.307kN>350kNPasses.

The source section table gives rounded gross area 6.59cm2 including root/toe geometry.

The course’s explicit leg-area model gives 6.54cm2 and is used consistently in this shear-lag calculation.

Do not mix the table gross area with a different corner subtraction without explaining the method.

Mechanism detailsWhy a connected angle leg matters2 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Locate the connected leg, outstanding leg and centroid before using the table.
  2. Only the connected leg directly receives the fastener force.
  3. The outstanding area may not become equally effective at the same section.

    This motivates the effective-area rule.

  4. Bolted, welded, single-angle and double-angle details can have different rules.

    Preserve the formula attached to the original case.

2. Balance weld forces, then expose the detailing conflict

Use the same mechanism: Unequal lever arms require unequal forces. The weld with the shorter lever arm must carry more force to balance the longer-arm weld’s moment.

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Why two weld lengths can be unequal

Two side welds must balance the load about its actual line of action.

Why two weld lengths can be unequal — Two side welds must balance the load about its actual line of action.

Sketch, not to scale; use the original dimensions.

  1. Find the load line and the lever arm to each weld.
  2. Balance moments as well as the total force.
  3. Convert each weld’s force into its own required length.

Remember: Equal-looking legs do not justify equal weld forces without equilibrium.

Related concept and full method

Name the side nearer the angle heel H and the free long-leg edge T.

Their transverse spacing is 65mm.

The centroid is 20.4mm from H and 65−20.4=44.6mm from T.

These are table-derived dimensions, not measured from the sketch.

Force per angle P=175kN. Taking moments about H for equilibrium: RT×65=175×20.4RT=54.923077kNRH=175−54.923077=120.076923kNCheck: RH+RT=175kN

For a transparent strength-only trial use 4mm fillet, the largest allowed by the source’s angle-edge maximum.

This trial will be rejected on the minimum-size condition below.

s=4mm: q=0.7×4×2501,000=0.7kNmmRequired H side effective length: 120.0769230.7=171.538462mmRequired T side effective length: 54.9230770.7=78.461538mmH side actual length: ≥171.538462+2×4=179.538462mmSelect 180mm. T side actual length: ≥78.461538+8=86.461538mmSelect 90mm. Provided H side resistance: (180−8)×0.7=120.4kN>120.076923kNT side resistance: (90−8)×0.7=57.4kN>54.923077kN

Repeat on both angles.

Effective lengths 172 and 82 exceed 40mm and 4s.

Both physical lengths exceed the 65mm side spacing.

Returns at least 8mm and lap at least max(5×6,25)=30mm would be required in such a trial.

Thicker part 12mm requires minimum weld leg 5mm. Angle edge thickness 6mm permits maximum weld leg 6−2=4mm. The required range 5≤s≤4 has no feasible value.

Conclusion: the angles pass tension, but no fillet leg satisfies both supplied detailing rules for the stated 6mm angle/12mm gusset detail.

The 4mm lengths 180/90mm are a strength demonstration, not an acceptable final detail.

A changed angle thickness or a separately justified alternative weld detail is required.

The task cannot be concluded by silently adopting 5 or 6mm along a 6mm angle edge.

Gusset net width is not given, so a complete gusset tensile check also cannot be established.

Mechanism detailsBalance two weld forces2 concepts · 5 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. The angle centroid/load line is generally not halfway between the two weld runs.
  2. .

    Both weld runs contribute to the applied force.

  3. .

    The run nearer the load line carries more force.

  4. For equal throat resistance per length, the required effective lengths follow the same ratio.

    Add detailing allowances afterwards.

Lecturer's answer

ItemLecturer's value
Connected / outstanding leg areaa1=2×62×6=744a_1=2\times62\times6=744, a2=2×47×6=564 mm2a_2=2\times47\times6=564\text{ mm}^2
Double-angle tensionPt=355(1308−0.15×564)=434.3 kN>350 kNP_t=355(1308-0.15\times564)=434.3\text{ kN}>350\text{ kN}
6 mm weld, total length350/1.05=333 mm350/1.05=333\text{ mm}, 167 mm per angle
Side X (centroid 20.4 mm from side X)167×44.6/65=115167\times44.6/65=115, add 2s → 130 mm
Side Y167−115=52167-115=52, add 2s → 65 mm; 15 mm returns

Conclusion: The angles are adequate; weld each angle with 6 mm fillets, 130 mm on side X and 65 mm on side Y, with 15 mm returns. Answer the exam this way.

Source: Lecturer's tutorial solution, Ch 2, p. 6.

Result and concise exam wording

Use the same mechanism: One connected leg does not load both legs equally. Keeping the same gross area does not guarantee the same tension resistance when the connection arrangement changes.

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

Double-angle tension: a1=2×62×6=744a_1=2\times62\times6=744, a2=2×47×6=564 mm2a_2=2\times47\times6=564\text{ mm}^2, Pt=355(1308−0.15×564)=434.3 kN>350 kNP_t=355(1308-0.15\times564)=434.3\text{ kN}>350\text{ kN}, adequate.Use 6 mm welds (0.7×6×250=1.05 kN/mm0.7\times6\times250=1.05\text{ kN/mm}): 350/1.05=333 mm350/1.05=333\text{ mm} in all, 167 mm per angle.Split about the centroid (20.4 mm from side X): side X 115 mm, add 2s, use 130 mm;side Y 52 mm, add 2s, use 65 mm; 15 mm returns.(Extra remark: under the weld-size rules a 6 mm angle edge may not allow a 6 mm weld; see section 2.)

Misconceptions and checks

Count cuts through each loaded bolt

Find how many shear planes transfer the force through one side of the connection.

The middle plate moves against two cover plates. The two interfaces cut each bolt at two planes.
The middle plate moves against two cover plates. The two interfaces cut each bolt at two planes.

Prediction, then explanation. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Select the area at the actual shear plane. Multiply by bolt shear strength. Count only the bolts and planes in the same transfer stage.

Ps=psAs,Pgroup=nbnsPsP_s=p_sA_s,\qquad P_{group}=n_b n_s P_s

ps is bolt shear strength in N/mm²; As is the appropriate area in mm². nb counts bolts; ns counts equally loaded shear planes.

Scope. Use the thread area when threads cross the plane as required. Check bearing, plate failure and detailing separately.

Check and takeaway. Both halves of a butt splice carry the full transmitted force in sequence. Counting both halves together would double the apparent resistance.

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

  • Use 175kN per angle, not 350 per angle.
  • Use the long-leg centroid coordinate cx, not cᵧ.
  • Use the double-angle welded reduction 0.15.
  • Check whether minimum and maximum weld-leg bounds overlap before declaring a design.

How the method transfers to a new variant

Use the same mechanism: Unequal lever arms require unequal forces. The weld with the shorter lever arm must carry more force to balance the longer-arm weld’s moment.

Use the same mechanism: One connected leg does not load both legs equally. Keeping the same gross area does not guarantee the same tension resistance when the connection arrangement changes.

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

  1. Identify the connected leg and force per angle.
  2. Calculate the course angle tension area including the correct shear-lag reduction.
  3. Check the permitted weld-size interval.
  4. If a permissible size exists, balance side forces with centroid lever arms.
  5. Convert to effective lengths, add end allowances and check actual capacities/detailing.

Prediction with explained answer

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

Prediction and explained answer.

Invented reasoning variant: would merely lengthening the 4mm welds solve the source minimum-leg problem?

Answer and reasoning

No. More length increases strength but does not change the 4mm leg.

The minimum remains 5mm.

The physical detail/material choice or an explicitly supported alternative detailing provision must change.