STEELWORK / CON4334
Mock solutions

Mock Q2: full solution and invented marking guide

Diagrams, explanations and answers are presented in reading order. No playback or response is required.
All answers shownChinese–English terminology
Diagrams, explanations and answers are presented in reading order. No playback or response is required.

Return to question.

All marking guidance is invented.

MOCK Q2(a) · double-cover splice, plan; all geometry repeated in the adjacent question.

Invented mock-question diagram: double-cover splice in plan.

Four bolts per half, with one cover plate on each main-plate face.

The dashed line is the main-plate butt joint.

Each nearest bolt centre is 40mm from the joint.

Longitudinal pitch 60mm.

The cover plate projects 40mm beyond the outermost bolt centre.

Transverse dimensions 30, 80, 30mm.

Main-plate thickness 12mm; cover-plate thickness 8mm; width 140mm.

All diagram dimensions are in mm.

Not to scale; dimension labels govern.Open full-size image.

(a) Follow one splice half and every requested failure mode

Count cuts through each loaded bolt

Find how many shear planes transfer the force through one side of the connection.

The middle plate moves against two cover plates. The two interfaces cut each bolt at two planes.
The middle plate moves against two cover plates. The two interfaces cut each bolt at two planes.

Prediction, then explanation. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Select the area at the actual shear plane. Multiply by bolt shear strength. Count only the bolts and planes in the same transfer stage.

Ps=psAs,Pgroup=nbnsPsP_s=p_sA_s,\qquad P_{group}=n_b n_s P_s

ps is bolt shear strength in N/mm²; As is the appropriate area in mm². nb counts bolts; ns counts equally loaded shear planes.

Scope. Use the thread area when threads cross the plane as required. Check bearing, plate failure and detailing separately.

Check and takeaway. Both halves of a butt splice carry the full transmitted force in sequence. Counting both halves together would double the apparent resistance.

Follow contact pressure into the plate

The bolt may survive shear while the connected plate deforms or tears near the hole.

The labels distinguish bolt diameter d from hole diameter d₀. The arrow at the hole edge shows the bearing contact action.
The labels distinguish bolt diameter d from hole diameter d₀. The arrow at the hole edge shows the bearing contact action.

Prediction, then explanation. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.

Calculate every bound required by the supplied rule. The smallest applicable bound limits the connection at that layer.

Pbearing≤pbsdtP_{bearing}\le p_{bs}dt

pbs is the applicable bearing strength in N/mm²; d is nominal bolt diameter in mm; t is plate thickness in mm.

Scope. This diameter term alone is not the complete check. End-distance and clear-ligament limits, bolt bearing and each connected layer also matter.

Check and takeaway. Two covers and one main plate do not necessarily have the same thickness or strength. Compare the actual force share in each layer.

Test every possible fracture cut

Find the remaining steel area across a candidate tension-failure path.

The dashed fracture line crosses two hole centres. Subtract only the holes crossed by that candidate line.
The dashed fracture line crosses two hole centres. Subtract only the holes crossed by that candidate line.

Prediction, then explanation. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.

Subtract the hole widths crossed by the path, then multiply by thickness. Compare all plausible paths using the applicable course rule.

An=(b−nd0)tA_n=(b-nd_0)t

An is net area in mm²; b is plate width; d₀ is hole diameter; t is thickness, all in mm. n counts holes on this straight path.

Scope. This expression is for a straight cut. Effective area can require further shear-lag rules. Gross, net and effective areas must remain distinct.

Check and takeaway. Use the hole diameter, not the bolt diameter, when removing missing steel. The plate contains a hole, not solid steel around the bolt shank.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Count where the bolt can be sheared

The plate interfaces are the places trying to cut across the bolt.

Count where the bolt can be sheared — The plate interfaces are the places trying to cut across the bolt.

Sketch, not to scale; use the original dimensions.

  1. Count actual loaded shear planes, not merely visible plates.
  2. Choose shank or threaded area for the plane concerned.
  3. Compare group resistance with the force that group transfers.

Remember: Bolts on opposite sides of a splice do not all act in parallel.

Related concept and full method

Physical interpretation: Why holes reduce tension resistance

The pull must squeeze through the steel left beside the holes.

Why holes reduce tension resistance — The pull must squeeze through the steel left beside the holes.

Sketch, not to scale; use the original dimensions.

  1. Choose a possible fracture line across the member.
  2. Subtract the holes crossed by that line using hole diameter.
  3. Apply the course effective-area rule and its gross-area limit.

Remember: Do not subtract every hole anywhere in the connection.

Related concept and full method

Each transfer half carries the full 300kN.

Four bolts share it:75kN per bolt.

Each cover/plane takes 37.5kN.

Eight bolts exist overall, but halves transfer load in series.

Do not divide 300 by 8.

M20 lookup At=245mm2, ps=375, pbb=1000Nmm2. Shear resistance per plane: 245×3751000=91.875kNTwo shear planes per bolt give 183.75; four bolts per half give 735kN>300. Bolt bearing at the main plate: 20×12×10001000=240kNThe two cover-plate contacts of each bolt: 2×20×8×10001000=320kNGoverning bearing resistance for four bolts: 4×min(240,320)=960kN>300

Connected-part bearing uses the least of all applicable terms.

Main and cover end distances are 40; clear hole ligament 60−22=38mm.

Main web/plate load per bolt 75kN; cover load per bolt 37.5kN.

Main-plate diameter term: 20×12×5501000=132kNMain-plate end-distance term: 0.5×40×12×5501000=132kNMain-plate net-clearance term and cap: min(1.5×38×12×510,2×20×12×800)1000=min(348.84,384)=348.84kNMain plate, per bolt: min(132,132,348.84)=132>75Half-joint resistance 528kN. For each 8mm cover plate, reduce each term by 812: 88, 88, min(232.56,256)=232.56, giving the governing per-bolt value 88>37.5kN. Bearing resistance of one half of each cover plate: 4×88=352kN>150

A critical transverse tension section crosses TWO holes, one in each bolt line.

Longitudinally separated holes are not all deducted at the same cut.

Main plate: Ag=140×12=1680mm2An=(140−2×22)×12=1152mm2Ae=min(1.1×1152,1680)=1267.2mm212mm S355 uses py=355; Pt=1267.2×3551000=449.856kN>300Each cover plate: Ag=140×8=1120mm2An=96×8=768mm2Ae=min(844.8,1120)=844.8mm2Pt,each=844.8×3551000=299.904kN>150
M20 minimum edge distance for rolled edges 26mm; end distance 40 and side edge distance 30 both pass.
Longitudinal pitch 60≥2.5×20=50; transverse spacing 80≥3×20=60.
Governing maximum spacing min(12×8,150)=96mm; 60/80 both pass.
Maximum cover-plate edge distance 11×8×275355=77.452848mm; 30 passes. The thicker main plate permits a larger maximum edge distance.
Width check: 30+80+30=140mm.

All requested checks pass.

Main net tension 449.856kN is the lowest calculated full-half resistance.

This scoped result does not claim an unrequested complete block-shear design.

Mechanism detailsCount the bolt shear planes5 concepts · 5 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Load must cross an interface between the connected plates.
  2. A lap joint gives one shear plane through a bolt.
  3. A symmetric double-cover joint may provide two shear planes.

    Count load-transfer interfaces, not just visible plates.

  4. Use the source’s area and shear strength.

    Then check bearing, plate resistance and detailing separately.

MOCK Q2(b) · closed rectangular weld; all geometry repeated in the adjacent question.

Invented mock-question diagram: closed rectangular weld.

B=200mm is width.

H=300mm is height; dashed lines intersect at the centroid.

The downward design force P=200kN acts at eccentricity e=250mm from the centroid.

Green lines are the continuous effective weld centrelines.

Plate thickness 12 and 18mm.

Not to scale; stated dimensions govern.Open full-size image.

(b) Direct shear plus torsion at the reinforcing corner

Treat a weld group as lines

An eccentric force creates direct line force and torsional line force in the same weld group.

The four perimeter lines represent weld runs. The interior label says No weld here: the enclosed plate area is not weld length.
The four perimeter lines represent weld runs. The interior label says No weld here: the enclosed plate area is not weld length.

Prediction, then explanation. Increasing eccentricity increases the torsional contribution. The governing corner depends on vector addition, not distance alone.

Find the line centroid. Integrate squared distance along the effective lines. Add direct and torsional components at every candidate critical point.

J=∫r2 dl,qMx=−My/J,qMy=Mx/JJ=\int r^2\,dl,\qquad q_{Mx}=-My/J,\quad q_{My}=Mx/J

J is line polar inertia in mm³. x and y use mm. With M in kN·mm, q is line force in kN/mm.

Scope. A solid rectangle has area inertia in mm⁴ and is not this weld-line model. Missing weld sides change the centroid and integrals.

Check and takeaway. Compare the largest resultant line force with the selected throat resistance. Keep kN/mm distinct from total force in kN.

The weld resists through its throat

Convert a visible fillet leg into resistance per effective length.

The two outer sides are the legs. The shorter perpendicular line through the ideal triangle is the throat.
The two outer sides are the legs. The shorter perpendicular line through the ideal triangle is the throat.

Prediction, then explanation. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

For the course right-angle equal-leg fillet, take throat as 0.7 times leg. Multiply throat area per unit length by weld strength.

a=0.7s,qcap=0.7spw/1000a=0.7s,\qquad q_{cap}=0.7sp_w/1000

s and a are leg and throat in mm. pw is weld strength in N/mm². qcap is resistance in kN/mm.

Scope. Use effective length, the correct steel/electrode strength and permitted leg limits. Full-penetration butt welds use a different model.

Check and takeaway. Illustration: a 6 mm leg at 250 N/mm² gives 0.7(6)(250)/1000=1.05 kN/mm0.7(6)(250)/1000=1.05\,\mathrm{kN/mm}.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Only the weld lines resist as weld

Imagine a wire rectangle: its empty middle is not more wire.

Only the weld lines resist as weld — Imagine a wire rectangle: its empty middle is not more wire.

Sketch, not to scale; use the original dimensions.

  1. Count only the weld runs actually shown.
  2. Use their total length and line second moments.
  3. Combine direct and torsional forces at the critical location.

Remember: Line second moments have units mm3; plate-area moments use mm4.

Related concept and full method

Physical interpretation: Add arrows before taking the magnitude

Walking east and walking north do not point in the same direction.

Add arrows before taking the magnitude — Walking east and walking north do not point in the same direction.

Sketch, not to scale; use the original dimensions.

  1. Choose signed horizontal and vertical directions.
  2. Add contributions along each direction separately.
  3. For perpendicular components, use the right-triangle resultant.

Remember: Check the corner where direct and torsional components reinforce each other.

Related concept and full method

Use the weld-length centroid at the rectangle centre.

Corner x=±100, y=±150mm.

Direct downward shear adds to torsional vertical shear on one side.

That side governs.

Weld-line inertias have units of mm3.

L=2(200+300)=1000mmqs=PL=2001000=0.2kNmmM=Pe=200×250=50000kN·mmIx=30036+200×30022=1.35×107mm3Iy=20036+300×20022=7333333.333333mm3J=Ix+Iy=20833333.333333mm3qv=0.2+50000×100J=0.440000000kNmm|qh|=50000×150J=0.360000000kNmmqmax=qv2+qh2=0.568506816kNmmqcap=0.7s×2501000=0.175sRequired weld leg: s≥0.5685068160.175=3.248610mm

The strength requirement alone would permit a small leg.

However, the 18mm thicker plate gives minimum 6mm.

At the 12mm thinner edge maximum=12−2=10mm.

Choose 6mm: qcap 1.05 kN/mm, which exceeds the calculated demand.

This closed effective-line mock does not use two-end deductions on each rectangle side.

The geometry was expressly defined as continuous.

Selected 6mm weld-leg utilisation 0.5685068161.05=0.541435<1; size 6 lie on opposite sides of the 6 to 10mm is within the range.

Mechanism detailsA weld group is a set of lines2 concepts · 5 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. The centre is empty: resistance comes from the weld lines, not a solid plate filling the group.
  2. Use line lengths for centroid weighting.

    Line second moments have units .

    Add the parallel-axis terms.

  3. Direct force per length is .

    The eccentric moment adds tangential flow proportional to distance from the centroid.

  4. Combine signed components at every candidate corner, then compare the maximum with throat resistance per length.

Compact script and invented marking guide

Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.

Use the same mechanism: Test every possible fracture cut. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.

Apply the reasoning to this section’s data and conditions

(a) Four bolts/half, double shear:735kN; bolt bearing 960; main plate bearing 528; main tension 449.856.

Each cover bearing 352 and tension 299.904kN.

All exceed corresponding 300/150kN actions; layout passes. (b) qmax=0.568507kNmm; strength leg≥3.249mm; detailing governs choose 6mm.

Invented credit: (a) force sharing 2, bolt checks 4, connected-part bearing 4, tension 4, layout/conclusion 4. (b) centroid/eccentric moment 2, length/inertias 3, corner components/resultant 3, size/detail/conclusion 4.

Mechanism detailsFollow the calculation sequence6 concepts · 2 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Locate the load, supports, connection geometry and any stated assumptions.
  2. Keep given values, table lookups and calculated values distinct; reconcile their units.
  3. The calculation player steps through the existing expressions in their original order.
  4. Compare demand with resistance or the relevant limit.

    Keep missing inputs and conditional conclusions explicit.