STEELWORK / CON4334
Mock solutions

Mock Q1: full solution and invented marking guide

Diagrams, explanations and answers are presented in reading order. No playback or response is required.
All answers shownChinese–English terminology
Diagrams, explanations and answers are presented in reading order. No playback or response is required.

Open only after attempting the question.

Return to question.

All marking guidance here is invented.

MOCK Q1 · slab → B1 → B2; all geometry repeated in the adjacent question.

Invented mock-question diagram.

Slab → B1 → B2 shows slab load passing first to B1, then B2.

The slab spans one way; interior denotes an internal beam.

Squares mark corner columns providing vertical support.

B1 spans 6m.

The two slab spans on the right are each 3m.

Schematic, not to scale; stated dimensions govern.Open full-size image.

(a) Load intensity

Keep load categories separate

A floor carries permanent material and changing occupancy loads. Find the design load for the stated check.

The two boxes show G and Q with their separate factors. The plus sign joins their factored values.
The two boxes show G and Q with their separate factors. The plus sign joins their factored values.

Prediction, then explanation. Increasing imposed load changes its own term. It does not change the dead-load factor or the steel stiffness.

First convert mass to weight where required. Next collect G and Q in compatible units. Apply the combination specified by the course problem.

Wu=1.4G+1.6QW_u=1.4G+1.6Q

G is characteristic dead load; Q is characteristic imposed load. Wu is the design load for this course gravity combination.

Scope. This combination is not universal. Use the specified service load for deflection and the stated factors for other standards or cases.

Check and takeaway. Illustration: G = 10 kN and Q = 5 kN give 22 kN. Factoring their sum by one guessed factor loses the distinction.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Why dead and imposed loads stay separate

Keep permanent load and imposed load separate until their respective factors have been applied.

Why dead and imposed loads stay separate — Keep two shopping baskets until their different multipliers are applied.

Sketch, not to scale; use the original dimensions.

  1. Include self-weight and permanent finishes in permanent load.
  2. Include the specified occupancy load in imposed load.
  3. For this course’s stated gravity combination: 1.4G+1.6Q.

Remember: That ULS combination is not the imposed-load deflection load.

Related concept and full method

G=0.160m×24.5kNm3+0.6=4.52kNm2U=1.4×4.52+1.6×3=11.128kNm2

Mechanism detailsFrom characteristic to design load1 concept · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. G is permanent load; Q is imposed load.

    A surface load and a line load also have different units.

  2. This illustration uses the course gravity case .

    Other combinations in the original text retain their own factors.

  3. For illustrative , the separate load contributions show what changes when Q increases.
  4. Do not carry this ULS total automatically into deflection.

    Follow the stated SLS load case.

(b) Trace the load path and calculate actions

Follow one strip of floor

An area load must become a beam load before beam reactions can be calculated.

The highlighted tributary strip supplies one beam. The right-hand labels show area load multiplied by width becoming line load.
The highlighted tributary strip supplies one beam. The right-hand labels show area load multiplied by width becoming line load.

Prediction, then explanation. At fixed area load, twice the tributary width gives twice the line load. An end reaction remains a concentrated force.

Consider one metre along the beam. The associated floor area is b square metres. Multiply area load by that width.

w=qbw=qb

q is area load in kN/m²; b is tributary width in m; w is line load in kN/m.

Scope. Determine b from slab spanning and supports. Add beam self-weight separately. A secondary-beam reaction is not automatically a UDL.

Check and takeaway. Illustration: 3 kN/m2×2 m=6 kN/m3\,\mathrm{kN/m^2}\times2\,\mathrm{m}=6\,\mathrm{kN/m}. The width cancels one length unit.

Use the same mechanism: Keep load categories separate. Increasing imposed load changes its own term. It does not change the dead-load factor or the steel stiffness.

Balance the isolated beam

Find the two vertical reactions before calculating internal shear or moment.

A / RₐB / RᵦPaL
A and B are vertical supports. The downward load acts at distance a from A. Its distance from B is L − a.

Prediction, then explanation. Move the same load toward B. Reaction B increases because the load has a larger moment arm about A.

Take moments about A. Reaction A has zero lever arm there. Then use vertical force balance to find reaction A.

RBL=Pa,RA+RB=PR_B L=Pa,\qquad R_A+R_B=P

P, RA and RB are forces in kN. L is support spacing and a is load position, both in m.

Scope. These expressions describe one point load on a simply supported beam. Add other loads through equilibrium; keep their actual positions.

Check and takeaway. Illustration: P = 60 kN, L = 6 m and a = 2 m give RB = 20 kN and RA = 40 kN.

Apply the reasoning to this section’s data and conditions

Physical interpretation: How a floor load reaches a beam

Each beam collects the load from its own strip of floor.

How a floor load reaches a beam — Each beam collects the load from its own strip of floor.

Sketch, not to scale; use the original dimensions.

  1. Find the tributary width from the actual plan.
  2. Area load × tributary width gives load per beam length.
  3. A supporting beam receives the other beam’s end reaction.

Remember: A reaction becomes a point load, not automatically a UDL.

Related concept and full method

Interior B1 collects half of each 3m slab bay:1.5+1.5=3m.

The B2 midpoint receives one B1 end reaction; top/bottom edge B1 reactions arrive directly at columns.

Those edge reactions do not add midpoint bending to B2.

B1 self-weight: 59.8×101000=0.598kNmwG=4.52×3+0.598=14.158wQ=3×3=9kNmwu=1.4×14.158+1.6×9=34.2212kNmRA=RB=wuL2=34.2212×62=102.664kNMmax=wuL28=34.2212×368=153.995kN·mAt B2 midspan, P=102.664kN, already factored. B2 UDL: 1.4×92.1×101000=1.2894kNmReaction at each B2 support: P2+wL2=102.6642+1.2894×62=55.2kNB2 maximum moment: Mmax=PL4+wL28=102.664×64+1.2894×368=159.798kN·m

Mechanism detailsFollow the floor load in 3D4 concepts · 2 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. The floor carries pressure in .

    The highlighted strip belongs to one secondary beam.

  2. Multiply pressure by tributary width: .

    The illustration uses .

  3. A primary beam receives the secondary beam reaction at their connection, not a new full-span UDL.
  4. Trace reactions down to columns and foundations.

    Count each loaded area once.

(c) Read exact rows and classify

Find which plate buckles first

Before using plastic bending resistance, check whether the flange and web can sustain the required stress distribution.

The short waves are local plate buckling. They differ from sideways movement of the whole member.
The short waves are local plate buckling. They differ from sideways movement of the whole member.

Prediction, then explanation. At fixed width, a thinner plate has a larger width-to-thickness ratio. Local buckling then becomes more restrictive.

Calculate the flange and web ratios separately. Compare each with the limits for its stress condition. The worse class governs.

ε=275/py\varepsilon=\sqrt{275/p_y}

py is the design yield strength in N/mm². ε is a dimensionless scale used in the supplied classification limits.

Scope. Pure bending and uniform compression use different web limits. Class 2 allows plastic resistance but not the Class 1 rotation capability.

Check and takeaway. A Class 1 web and Class 2 flange give a Class 2 section. Do not average the class numbers.

A table value has conditions

Find a design property without mixing a row, column or standard from a different case.

The row and column meet at one cell. The table heading supplies the units and the conditions that give the cell meaning.
The row and column meet at one cell. The table heading supplies the units and the conditions that give the cell meaning.

Prediction, then explanation. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Match the complete section designation. Read the relevant axis and unit. For strength tables, select material, thickness and curve before interpolating.

Given values come from the question. Lookup values come from a named table. Assumed values require an explicit condition.

Scope. A missing row or omitted restraint cannot be recovered from a schematic’s scale. Keep the result conditional when required data are absent.

Check and takeaway. Record the table, row, column and unit beside the substitution. That makes a later check possible.

Apply the reasoning to this section’s data and conditions

Physical interpretation: A thin part can wrinkle first

A thin plate may wrinkle before the whole steel member reaches its intended resistance.

A thin part can wrinkle first — A thin plate may wrinkle before the whole steel member reaches its intended resistance.

Sketch, not to scale; use the original dimensions.

  1. Check flange and web slenderness using their own definitions.
  2. Compare each ratio with the correct class limits.
  3. The element with the more restrictive class determines the section class.

Remember: Bending limits and uniform-compression limits are different.

Related concept and full method

Lookup: Data File pp.9–10, exact 457×152×60 UB row.

Dimensions on p.9; properties on p.10.

D is overall depth.

d is the clear web depth between root fillets, not the nominal designation.

PropertyLookup value / conversion
DimensionsD454.6, web t 8.1, flange T13.3, root r 10.2, clear d 407.6, all mm
Local ratiosbT=5.75;dt=50.3。
Major-axis propertiesIx=25500cm4=2.55×108mm4; Zx=1122cm3; Sx=1287cm3.
LTB propertiesry=3.23cm=32.3mm; u=0.868; torsional index x=37.5.
S355, flange T=13.3mm, giving py=355Nmm2. ε=275355=0.880141Flange: bT=5.75<9ε=7.921268Web in bending: dt=50.3<80ε=70.411267Both are Class 1, so βW=1; plastic bending resistance is permitted.dt=50.3<70ε=61.609858No separate shear-buckling calculation is needed under the course limit.

Lookup: Data File pp.9–10, exact 533×210×92 UB row.

Dimensions on p.9; properties on p.10.

D is overall depth.

d is the clear web depth between root fillets, not the nominal designation.

PropertyLookup value / conversion
DimensionsD533.1, web t 10.1, flange T15.6, root r 12.7, clear d 476.5, all mm
Local ratiosbT=6.71;dt=47.2。
Major-axis propertiesIx=55230cm4=5.523×108mm4; Zx=2072cm3; Sx=2360cm3.
LTB propertiesry=4.51cm=45.1mm; u=0.872; torsional index x=36.5.
S355, flange T=15.6mm, giving py=355Nmm2. ε=275355=0.880141Flange: bT=6.71<9ε=7.921268Web in bending: dt=47.2<80ε=70.411267Both are Class 1, so βW=1; plastic bending resistance is permitted.dt=47.2<70ε=61.609858No separate shear-buckling calculation is needed under the course limit.

Mechanism detailsWhy thin elements buckle locally2 concepts · 18 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. The flange outstand and web have different widths, thicknesses and edge support conditions.
  2. A thinner plate can wrinkle locally before the complete member loses stability.
  3. Class 1 allows plastic rotation.

    Class 2 reaches plastic resistance.

    Class 3 reaches elastic resistance.

    Class 4 requires effective properties.

  4. Check every relevant compression element with the supplied limits and stress distribution.

    The deformation shown is qualitative.

(d) B1 resistance and deflection

The web carries the shear check

Compare the applied shear with the resistance of the prescribed shear area.

At the imaginary cut, opposing arrows resist relative sliding. The rolled-UB calculation below assigns the shear area to the web.
At the imaginary cut, opposing arrows resist relative sliding. The rolled-UB calculation below assigns the shear area to the web.

Prediction, then explanation. At fixed design strength and depth, increasing web thickness increases this shear resistance.

Calculate the prescribed shear area. Multiply by the design shear stress from the course rule. Then compare matching force units.

Av=Dt,Vc=pyAv/3A_v=Dt,\qquad V_c=p_yA_v/\sqrt{3}

D is overall depth; t is web thickness, in mm. Av uses mm². py uses N/mm², giving Vc in N.

Scope. Apply this area definition to the stated rolled section. Check web slenderness separately. The factor 0.6 is the low-shear threshold, not this resistance coefficient.

Check and takeaway. A shear pass alone does not prove bending, deflection or local support-web adequacy.

Internal tension and compression resist moment

Find which section resistance applies before comparing it with the moment demand.

In sagging bending, the upper region compresses and the lower region stretches. Together their forces form a resisting couple.
In sagging bending, the upper region compresses and the lower region stretches. Together their forces form a resisting couple.

Prediction, then explanation. A larger appropriate section modulus raises resistance at fixed strength. Local plate buckling can restrict the usable modulus.

Classify the section first. At low shear, use the elastic expression for Class 3 or the prescribed capped plastic expression for Classes 1 and 2.

Mc=min⁡(pyS,1.2pyZ)for Class 1/2 at low shearM_c=\min(p_yS,1.2p_yZ)\quad\text{for Class 1/2 at low shear}

py uses N/mm². S is plastic modulus and Z is elastic modulus, both in mm³. Mc then uses N·mm.

Scope. This is section resistance, not whole-member LTB resistance. High shear and Class 4 require their appropriate treatment.

Check and takeaway. Selecting the larger of the two capped terms defeats the cap. Use their minimum.

Shear and bending share the web

Decide whether the unreduced bending resistance remains applicable at the section being checked.

The same web region participates in shear and longitudinal bending stress. The two demands must be evaluated at one section.
The same web region participates in shear and longitudinal bending stress. The two demands must be evaluated at one section.

Prediction, then explanation. Raising shear beyond the specified threshold can reduce available bending resistance. A distant maximum shear is not the coexistent shear.

Find the moment-check position. Evaluate the shear there. Compare it with the low-shear threshold before selecting the resistance expression.

V≤0.6Vcis the course low-shear conditionV\le0.6V_c\quad\text{is the course low-shear condition}

V is shear at the checked section; Vc is its shear resistance. Both use the same force unit.

Scope. Above the threshold, use the supplied reduction expression. The threshold itself is not a substitute resistance formula.

Check and takeaway. If the maximum shear anywhere is below the threshold, all sections satisfy that low-shear condition. Otherwise check the actual positions.

Apply the reasoning to this section’s data and conditions

Physical interpretation: How much does the beam sag?

Strength asks whether it fails; deflection asks how far it moves.

How much does the beam sag? — Strength asks whether it fails; deflection asks how far it moves.

Sketch, not to scale; use the original dimensions.

  1. Use the serviceability load case specified by the course question.
  2. Choose the expression matching the support and load positions.
  3. Use consistent units for load, length, E and I.

Remember: The largest deflection is not always at midspan.

Related concept and full method

Av=tD=8.1×454.6=3682.26mm2Vc=pyAv3=355×3682.263×1,000=754.713600kNVmax=102.663600kN<VcShear passes.0.6Vc=452.828160kN>VmaxEven maximum shear is low, so the low-shear bending formula applies throughout the beam.Mc=min(pySx,1.2pyZx)=min(355×12871,000,1.2×355×11221,000)=min(456.885,477.972)=456.885kN·m|M|max=153.995400kN·mBending passes.
Imposed line load: w=9kNm=9NmmI=25500×10000=255000000mm4δ=5wL4384EI=5×9×60004384×205000×255000000=2.905308mmLimit 6000360=16.666667mm; δ: passes.

Mechanism detailsSee shear in the web4 concepts · 2 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Internal shear keeps the two sides of the cut in vertical equilibrium.
  2. For the course’s common I-section case, the web provides the principal shear area.

    Use the specified definition.

  3. A slender web may require a different shear-buckling route before a simple shear-resistance formula is used.
  4. Use where applicable in the course.

    Convert N to kN before comparing with design shear.

(e) B2 resistance and deflection

Use the same mechanism: The web carries the shear check. At fixed design strength and depth, increasing web thickness increases this shear resistance.

Use the same mechanism: Internal tension and compression resist moment. A larger appropriate section modulus raises resistance at fixed strength. Local plate buckling can restrict the usable modulus.

Use the same mechanism: Shear and bending share the web. Raising shear beyond the specified threshold can reduce available bending resistance. A distant maximum shear is not the coexistent shear.

Apply the reasoning to this section’s data and conditions

Av=tD=10.1×533.1=5384.31mm2Vc=pyAv3=355×5384.313×1,000=1103.564654kNVmax=55.200000kN<VcShear passes.0.6Vc=662.138792kN>VmaxEven maximum shear is low, so the low-shear bending formula applies throughout the beam.Mc=min(pySx,1.2pyZx)=min(355×23601,000,1.2×355×20721,000)=min(837.8,882.672)=837.8kN·m|M|max=159.797700kN·mBending passes.
B1 end reaction from imposed load only: Pq=9×62=27kNI=55230×10000=552300000mm4δ=PqL348EI=27000×6000348×205000×552300000=1.073118mmLimit 6000360=16.666667mm; δ: passes.

Full lateral restraint is explicitly supplied, so no LTB check is needed here.

This does not establish an unspecified web-contact detail.

The mock expressly excludes that scope.

Mechanism detailsSee shear in the web4 concepts · 2 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Internal shear keeps the two sides of the cut in vertical equilibrium.
  2. For the course’s common I-section case, the web provides the principal shear area.

    Use the specified definition.

  3. A slender web may require a different shear-buckling route before a simple shear-resistance formula is used.
  4. Use where applicable in the course.

    Convert N to kN before comparing with design shear.

(f) Strength versus stiffness

A safe beam can still sag too far

Check whether the beam displacement exceeds the permitted service limit.

The straight beam marks the unloaded position. The curved line and vertical arrow show downward displacement, exaggerated for explanation.
The straight beam marks the unloaded position. The curved line and vertical arrow show downward displacement, exaggerated for explanation.

Prediction, then explanation. For the same UDL and stiffness, doubling span multiplies deflection by sixteen. Doubling I halves deflection.

Load bends each beam segment. The curvature accumulates along the span. Material stiffness E and geometric stiffness I resist that deformation.

δmid=5wL4384EI\delta_{mid}=\frac{5wL^4}{384EI}

Use w in N/mm, L in mm, E in N/mm² and I in mm⁴. The resulting midspan deflection is in mm.

Scope. The formula assumes a prismatic, simply supported, linear-elastic beam with full-span UDL. Use the stated service load and deflection limit.

Check and takeaway. A higher yield grade does not automatically increase E. Passing a strength check therefore does not prove acceptable deflection.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Strong enough and stiff enough are two questions

A shelf can avoid breaking yet still sag too much.

Strong enough and stiff enough are two questions — A shelf can avoid breaking yet still sag too much.

Sketch, not to scale; use the original dimensions.

  1. ULS checks safety against the relevant failure modes.
  2. SLS checks the specified everyday-use limit.
  3. Use the load case required for each check.

Remember: Check deflection separately after checking bending resistance.

The two checks use different limits.

Related concept and full method

Strength concerns resistance to yielding/failure, using design strength and capacities.

Stiffness concerns elastic deformation, usingE andI.

A higher grade can raise bending resistance without changing the courseE; changing section depth can substantially increaseI and reduce deflection.

Therefore a member may pass strength and fail serviceability.

Mechanism detailsSee stiffness and deflection1 concept

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Use the specified SLS load, span and support arrangement.

    The demonstrator has a full-span UDL.

  2. The loaded beam bends.

    The deformation is exaggerated so its shape can be seen.

  3. For a simply supported full-span UDL, .

    Double L with w, E and I unchanged: δ becomes 16 times as large.

  4. The readout uses , and .

    Select the finish/support-specific limit from the original table.

Compact script and invented marking guide

Use the same mechanism: Follow one strip of floor. At fixed area load, twice the tributary width gives twice the line load. An end reaction remains a concentrated force.

Use the same mechanism: The web carries the shear check. At fixed design strength and depth, increasing web thickness increases this shear resistance.

Use the same mechanism: Internal tension and compression resist moment. A larger appropriate section modulus raises resistance at fixed strength. Local plate buckling can restrict the usable modulus.

Apply the reasoning to this section’s data and conditions

PartResults / suggested credit
a /4G=4.52, U=11.128kNm2; correct thickness units, each worth 2 marks.
b /8

B1 w 34.2212,V102.664,M153.995; B2 P102.664,w 1.2894,V55.2,M159.798.

Credit load path 2, line loads 2, reactions 2, moments 2.

c /4BothClass 1;2 per correctly justified section.
d /10

Shear 2, low-shear/bending 3, service load 2, deflection/limit 3.

δB1=2.9053mm.

e /10

Same distribution.

δB2=1.0731mm.

Use imposed reaction only.

f /42 per explained distinction, including one implication.

Mechanism detailsFollow the calculation sequence5 concepts · 4 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Locate the load, supports, connection geometry and any stated assumptions.
  2. Keep given values, table lookups and calculated values distinct; reconcile their units.
  3. The calculation player steps through the existing expressions in their original order.
  4. Compare demand with resistance or the relevant limit.

    Keep missing inputs and conditional conclusions explicit.