STEELWORK / CON4334
Worked examples

Beam example 4: a tight LTB check with three point loads

Diagrams, explanations and answers are presented in reading order. No playback or response is required.

← Read this lecture example beside its chapter concepts

All answers shownChinese–English terminology
Diagrams, explanations and answers are presented in reading order. No playback or response is required.

Select/check a S355 simply supported beam of 5m span carrying three characteristic point loads, each 22kN dead plus 12kN imposed, and a 2kNm dead UDL. Loading is normal. Ends are restrained against torsion, with compression flange free to rotate in plan; there is no intermediate lateral restraint.

Original source: LectureNotes/Ch 3_Beam.pdf — p. 31, p. 32, p. 33.

A given value comes from the question or diagram.

A lookup value comes from the named table.

A calculated value follows from the working.

Each assumption is stated where the calculation needs it.

Known information, diagram labels and unknowns

Moment shape matters within one segment

Represent a nonuniform moment distribution in the applicable member-buckling equation.

The two diagrams have equal peaks. The left high-moment region is short; the right high-moment region extends across more of the segment.
The two diagrams have equal peaks. The left high-moment region is short; the right high-moment region extends across more of the segment.

Prediction, then explanation. Two segments can have equal peak moment but different distributions. Their equivalent moment factors can therefore differ.

Evaluate moments from the true whole-beam analysis at the required positions. Apply the exact table’s weights, signs and lower bound.

mLT is an LTB factor. mx and my belong to the specified flexural checks. They are not interchangeable.

Scope. Some rules use magnitudes; others require signed ordinates. A factor does not reduce the actual moment used in a local section check.

Check and takeaway. Measure quarter points from the segment start, not automatically from the beam’s left support.

A table value has conditions

Find a design property without mixing a row, column or standard from a different case.

The row and column meet at one cell. The table heading supplies the units and the conditions that give the cell meaning.
The row and column meet at one cell. The table heading supplies the units and the conditions that give the cell meaning.

Prediction, then explanation. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Match the complete section designation. Read the relevant axis and unit. For strength tables, select material, thickness and curve before interpolating.

Given values come from the question. Lookup values come from a named table. Assumed values require an explicit condition.

Scope. A missing row or omitted restraint cannot be recovered from a schematic’s scale. Keep the result conditional when required data are absent.

Check and takeaway. Record the table, row, column and unit beside the substitution. That makes a later check possible.

Apply the reasoning to this section’s data and conditions

InputSource/use
Span and load positionsGiven dimension chain; central point is at 2.5m.
Lateral modelThe question specifies normal loading, end torsional restraint and free in-plane rotation, so LE=L=5,000mm.
Trial sectionThe source properties correspond to 457×152×52 UB: D=449.8, t=7.6, T=10.9mm, bT=6.99, dt=53.6, ry=3.11cm, Zx=950, Sx=1,096cm3, u=0.859, x=43.9.
Table sourceData File pp.9–10 exact section row; p.5 Table 8.3a strength; p.6 moment factors.

Why this method applies

Use the same mechanism: Moment shape matters within one segment. Two segments can have equal peak moment but different distributions. Their equivalent moment factors can therefore differ.

Vertical bending can trigger sideways motion

A beam has enough local bending resistance. Check whether its compression flange can move sideways and twist.

The dashed straight line is the initial reference. The curved flange lines illustrate the labelled sideways movement and twist.
The dashed straight line is the initial reference. The curved flange lines illustrate the labelled sideways movement and twist.

Prediction, then explanation. Adding a valid lateral restraint shortens a stability segment. It need not change the beam’s vertical reaction or moment diagram.

Identify the compressed flange and effective restraints. Calculate the specified slenderness, read buckling strength and compare resistance with the segment demand.

λ=LE/ry,Mb=pbSx  (Class 1/2),mLTMmax≤Mb\lambda=L_E/r_y,\qquad M_b=p_bS_x\;\text{(Class 1/2)},\qquad m_{LT}M_{max}\le M_b

LE and ry use the same length unit. pb uses N/mm²; Sx uses mm³; Mb uses N·mm. mLT is dimensionless.

Scope. Use the specified section class, effective-length branch and loading condition. Load height alone does not prove a destabilizing case.

Check and takeaway. Removing a lateral restraint requires a new segment stability check. The old shorter-segment result cannot establish the longer segment’s adequacy.

Balance the isolated beam

Find the two vertical reactions before calculating internal shear or moment.

A / RₐB / RᵦPaL
A and B are vertical supports. The downward load acts at distance a from A. Its distance from B is L − a.

Prediction, then explanation. Move the same load toward B. Reaction B increases because the load has a larger moment arm about A.

Take moments about A. Reaction A has zero lever arm there. Then use vertical force balance to find reaction A.

RBL=Pa,RA+RB=PR_B L=Pa,\qquad R_A+R_B=P

P, RA and RB are forces in kN. L is support spacing and a is load position, both in m.

Scope. These expressions describe one point load on a simply supported beam. Add other loads through equilibrium; keep their actual positions.

Check and takeaway. Illustration: P = 60 kN, L = 6 m and a = 2 m give RB = 20 kN and RA = 40 kN.

Apply the reasoning to this section’s data and conditions

Symmetry makes analysis simple but does not provide lateral restraint.

Check the entire 5m length for LTB.

Because there are several point loads plus a UDL, the general quarter-point moment factor is appropriate.

The result is close to the resistance.

Therefore, use actual u and v and interpolate without early rounding.

1. Ultimate loading

Keep load categories separate

A floor carries permanent material and changing occupancy loads. Find the design load for the stated check.

The two boxes show G and Q with their separate factors. The plus sign joins their factored values.
The two boxes show G and Q with their separate factors. The plus sign joins their factored values.

Prediction, then explanation. Increasing imposed load changes its own term. It does not change the dead-load factor or the steel stiffness.

First convert mass to weight where required. Next collect G and Q in compatible units. Apply the combination specified by the course problem.

Wu=1.4G+1.6QW_u=1.4G+1.6Q

G is characteristic dead load; Q is characteristic imposed load. Wu is the design load for this course gravity combination.

Scope. This combination is not universal. Use the specified service load for deflection and the stated factors for other standards or cases.

Check and takeaway. Illustration: G = 10 kN and Q = 5 kN give 22 kN. Factoring their sum by one guessed factor loses the distinction.

Apply the reasoning to this section’s data and conditions

Each point load: P=1.4×22+1.6×12=30.8+19.2=50kNw=1.4×2=2.8kNmTotal load: 3×50+2.8×5=164kN

Mechanism detailsFrom characteristic to design load1 concept · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. G is permanent load; Q is imposed load.

    A surface load and a line load also have different units.

  2. This illustration uses the course gravity case .

    Other combinations in the original text retain their own factors.

  3. For illustrative , the separate load contributions show what changes when Q increases.
  4. Do not carry this ULS total automatically into deflection.

    Follow the stated SLS load case.

2. Reactions, moment and quarter-point ordinates

Use the same mechanism: Moment shape matters within one segment. Two segments can have equal peak moment but different distributions. Their equivalent moment factors can therefore differ.

Use the same mechanism: Balance the isolated beam. Move the same load toward B. Reaction B increases because the load has a larger moment arm about A.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Why reactions balance the loads

Think of a seesaw that must neither fall nor turn.

Why reactions balance the loads — Think of a seesaw that must neither fall nor turn.

Sketch, not to scale; use the original dimensions.

  1. Upward and downward forces must balance.
  2. Take moments about a support to eliminate its reaction.
  3. Use perpendicular distance from the point to the force line.

Remember: A lateral restraint is not automatically a vertical support.

Related concept and full method

RA=RB=1642=82kNImmediately left of midspan: V=82−2.8×2.5−50=25kNImmediately right of midspan: V=25−50=−25kNTherefore the maximum moment occurs at midspan.Mmax=82×2.5−2.8×2.522−50(2.5−1)=205−8.75−75=121.25kN·mIn the interval 14 of the span, namely x=1.25m: M2=82×1.25−2.8×1.2522−50(1.25−1)=102.5−2.1875−12.5=87.8125kN·mM3=121.25; by symmetry, M4=87.8125kN·m.

The lower three-quarter point is at 3.75m.

The equality to M2 follows from the symmetric loading; alternatively include both loads to its left in the free body.

No moment contribution is assigned to a load lying to the right of the cut.

Mechanism detailsRead the moment shape within one segment2 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Moment ordinates must belong to the same effective unbraced segment.
  2. Same-side and reverse-curvature diagrams have different signed end ratios.
  3. The markers show ¼, ½ and ¾ of this segment, not of the entire beam.
  4. LTB and column flexural factors are different.

    Preserve their individual bounds and coefficient sets.

3. Trial section and section moment capacity

Internal tension and compression resist moment

Find which section resistance applies before comparing it with the moment demand.

In sagging bending, the upper region compresses and the lower region stretches. Together their forces form a resisting couple.
In sagging bending, the upper region compresses and the lower region stretches. Together their forces form a resisting couple.

Prediction, then explanation. A larger appropriate section modulus raises resistance at fixed strength. Local plate buckling can restrict the usable modulus.

Classify the section first. At low shear, use the elastic expression for Class 3 or the prescribed capped plastic expression for Classes 1 and 2.

Mc=min⁡(pyS,1.2pyZ)for Class 1/2 at low shearM_c=\min(p_yS,1.2p_yZ)\quad\text{for Class 1/2 at low shear}

py uses N/mm². S is plastic modulus and Z is elastic modulus, both in mm³. Mc then uses N·mm.

Scope. This is section resistance, not whole-member LTB resistance. High shear and Class 4 require their appropriate treatment.

Check and takeaway. Selecting the larger of the two capped terms defeats the cap. Use their minimum.

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

Preliminary section-modulus guide: S≥121.25×106355=341,549.3mm3=341.549cm3The lecturer selects 457×152×52, whose Sx=1,096cm3, because LTB is more restrictive than yielding.T=10.9≤16mm→py=355Nmm2Mc=min(355×1,0961,000,1.2×355×9501,000)=min(389.08,404.7)=389.08kN·m>121.25

A small section satisfying M/pᵧ alone would not necessarily pass LTB.

The chosen section is a verified trial, not a proof that every lighter section fails.

Mechanism detailsCompression and tension across a section2 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. For sagging, the top flange is in compression and the bottom in tension; hogging reverses this.
  2. Elastic bending stress varies with distance from the neutral axis: .
  3. The section class governs whether elastic, plastic or effective properties may be used.
  4. Use the shear at the section under examination.

    The largest shear elsewhere is not automatically coexistent.

4. Section class and shear-web threshold

Find which plate buckles first

Before using plastic bending resistance, check whether the flange and web can sustain the required stress distribution.

The short waves are local plate buckling. They differ from sideways movement of the whole member.
The short waves are local plate buckling. They differ from sideways movement of the whole member.

Prediction, then explanation. At fixed width, a thinner plate has a larger width-to-thickness ratio. Local buckling then becomes more restrictive.

Calculate the flange and web ratios separately. Compare each with the limits for its stress condition. The worse class governs.

ε=275/py\varepsilon=\sqrt{275/p_y}

py is the design yield strength in N/mm². ε is a dimensionless scale used in the supplied classification limits.

Scope. Pure bending and uniform compression use different web limits. Class 2 allows plastic resistance but not the Class 1 rotation capability.

Check and takeaway. A Class 1 web and Class 2 flange give a Class 2 section. Do not average the class numbers.

The web carries the shear check

Compare the applied shear with the resistance of the prescribed shear area.

At the imaginary cut, opposing arrows resist relative sliding. The rolled-UB calculation below assigns the shear area to the web.
At the imaginary cut, opposing arrows resist relative sliding. The rolled-UB calculation below assigns the shear area to the web.

Prediction, then explanation. At fixed design strength and depth, increasing web thickness increases this shear resistance.

Calculate the prescribed shear area. Multiply by the design shear stress from the course rule. Then compare matching force units.

Av=Dt,Vc=pyAv/3A_v=Dt,\qquad V_c=p_yA_v/\sqrt{3}

D is overall depth; t is web thickness, in mm. Av uses mm². py uses N/mm², giving Vc in N.

Scope. Apply this area definition to the stated rolled section. Check web slenderness separately. The factor 0.6 is the low-shear threshold, not this resistance coefficient.

Check and takeaway. A shear pass alone does not prove bending, deflection or local support-web adequacy.

Apply the reasoning to this section’s data and conditions

ε=275355=0.880141bT=6.99<9ε=7.92127;dt=53.6<80ε=70.4113is Class 1.dt=53.6<70ε=61.6099No separate web shear-buckling calculation is needed.

Mechanism detailsWhy thin elements buckle locally2 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. The flange outstand and web have different widths, thicknesses and edge support conditions.
  2. A thinner plate can wrinkle locally before the complete member loses stability.
  3. Class 1 allows plastic rotation.

    Class 2 reaches plastic resistance.

    Class 3 reaches elastic resistance.

    Class 4 requires effective properties.

  4. Check every relevant compression element with the supplied limits and stress distribution.

    The deformation shown is qualitative.

5. Shear and low-shear bending applicability

Use the same mechanism: The web carries the shear check. At fixed design strength and depth, increasing web thickness increases this shear resistance.

Shear and bending share the web

Decide whether the unreduced bending resistance remains applicable at the section being checked.

The same web region participates in shear and longitudinal bending stress. The two demands must be evaluated at one section.
The same web region participates in shear and longitudinal bending stress. The two demands must be evaluated at one section.

Prediction, then explanation. Raising shear beyond the specified threshold can reduce available bending resistance. A distant maximum shear is not the coexistent shear.

Find the moment-check position. Evaluate the shear there. Compare it with the low-shear threshold before selecting the resistance expression.

V≤0.6Vcis the course low-shear conditionV\le0.6V_c\quad\text{is the course low-shear condition}

V is shear at the checked section; Vc is its shear resistance. Both use the same force unit.

Scope. Above the threshold, use the supplied reduction expression. The threshold itself is not a substitute resistance formula.

Check and takeaway. If the maximum shear anywhere is below the threshold, all sections satisfy that low-shear condition. Otherwise check the actual positions.

Use the same mechanism: Internal tension and compression resist moment. A larger appropriate section modulus raises resistance at fixed strength. Local plate buckling can restrict the usable modulus.

Apply the reasoning to this section’s data and conditions

Av=7.6×449.8=3,418.48mm2Vc=355×3,418.483×1,000=700.649kNVmax=82kN<700.649: shear passes. Shear at the same midspan section 25kN<0.6×700.649=420.390kN, so the low-shear Mc above applies.

Mechanism detailsSee shear in the web3 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Internal shear keeps the two sides of the cut in vertical equilibrium.
  2. For the course’s common I-section case, the web provides the principal shear area.

    Use the specified definition.

  3. A slender web may require a different shear-buckling route before a simple shear-resistance formula is used.
  4. Use where applicable in the course.

    Convert N to kN before comparing with design shear.

6. Equivalent moment from Table 8.4b

Use the same mechanism: Moment shape matters within one segment. Two segments can have equal peak moment but different distributions. Their equivalent moment factors can therefore differ.

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Why the shape of the moment diagram matters

The same peak moment is more demanding when a long region stays near that peak.

Why the shape of the moment diagram matters — The same peak moment is more demanding when a long region stays near that peak.

Sketch, not to scale; use the original dimensions.

  1. Use the diagram of this unrestrained segment.
  2. Choose the applicable course sketch or quarter-point rule.
  3. Apply its factor to the demand, following the stated check.

Remember: Column flexural-buckling factors and LTB factors are not interchangeable.

Related concept and full method

mLT=0.2+0.15×87.8125+0.5×121.25+0.15×87.8125121.25=0.917268>0.44Equivalent moment: mLTMmax=0.2×121.25+0.3×87.8125+0.5×121.25=111.21875kN·m

This factor applies to member LTB only.

The cross-section still must carry the actual 121.25kN·m.

Mechanism detailsRead the moment shape within one segment2 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Moment ordinates must belong to the same effective unbraced segment.
  2. Same-side and reverse-curvature diagrams have different signed end ratios.
  3. The markers show ¼, ½ and ¾ of this segment, not of the entire beam.
  4. LTB and column flexural factors are different.

    Preserve their individual bounds and coefficient sets.

7. Effective length and equivalent slenderness

Use the same mechanism: Vertical bending can trigger sideways motion. Adding a valid lateral restraint shortens a stability segment. It need not change the beam’s vertical reaction or moment diagram.

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Which length belongs in the calculation?

A sideways tie can shorten the buckling region without shortening the beam’s vertical span.

Which length belongs in the calculation? — A sideways tie can shorten the buckling region without shortening the beam’s vertical span.

Sketch, not to scale; use the original dimensions.

  1. Separate vertical-support spacing from lateral-restraint spacing.
  2. Apply the course rule for the actual end restraint and loading.
  3. Keep the original vertical load analysis unless its supports change.

Remember: Restraints in one direction may not restrain the other direction.

Related concept and full method

LE=5,000mm;ry=3.11cm=31.1mmλ=5,00031.1=160.771704λx=160.77170443.9=3.662226v=[1+0.05(3.662226)2]−0.25=0.879594u=0.859;βw=1λLT=0.859×0.879594×160.771704×1=121.474465

The source rounds λ to 160.8 and v to 0.880, obtaining 121.6.

Both approaches pass.

However, the exact values avoid losing the small margin in this example.

Mechanism detailsA beam bends sideways and twists2 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. For the illustrated sagging beam the top flange is compressed.
  2. The unrestrained compression flange can move sideways while the complete cross-section twists.
  3. Only effective restraints divide the member into unbraced segments.

    They do not automatically add vertical supports.

  4. Use the segment effective length, section properties and matching moment factor.

    This is an exaggerated mode shape, not a calculated displacement.

8. Interpolate strength and compare

Use the same mechanism: Vertical bending can trigger sideways motion. Adding a valid lateral restraint shortens a stability segment. It need not change the beam’s vertical reaction or moment diagram.

Move between two known values

The required slenderness lies between two table rows. Estimate the strength on the straight segment between those rows.

xy(70, 200)(74, 192)(80, 180)70748040% of input interval → 40% of output change
The marked position lies partway along the horizontal interval. Use the same fraction of the vertical change.

Prediction, then explanation. If the second strength is lower, moving toward that row must reduce the interpolated strength.

Subtract the lower input to find distance travelled. Divide by the input interval. Multiply that fraction by the output change.

f=x−x0x1−x0,y=y0+f(y1−y0)f=\frac{x-x_0}{x_1-x_0},\qquad y=y_0+f(y_1-y_0)

x is the required input. The two known pairs are (x₀, y₀) and (x₁, y₁). f has no unit.

Scope. Use one table, curve and strength column. This interpolation does not permit extrapolation or inventing an intermediate steel section.

Check and takeaway. Illustration: between strengths 200 and 180, a fraction of 0.4 gives 192 N/mm². The result lies between both endpoints.

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

Physical interpretation: A beam can escape sideways

The compressed flange can move sideways while the section twists.

A beam can escape sideways — The compressed flange can move sideways while the section twists.

Sketch, not to scale; use the original dimensions.

  1. Divide the beam at effective lateral restraints.
  2. Use each segment’s effective length to obtain its buckling resistance.
  3. Compare that resistance with the segment’s equivalent moment demand.

Remember: A section bending check alone does not check lateral-torsional buckling.

Related concept and full method

Table 8.3a: S355,py=355 column.λLT=120, pb=104; 125, pb=97Nmm2. Interpolation fraction: f=121.474465−120125−120=0.294893pb=104+0.294893(97−104)=101.935748Nmm2Mb=pbSx=101.935748×1,0961,000=111.721580kN·mDemand 111.218750< resistance 111.721580: LTB passes. Margin: 111.721580−111.218750=0.502830kN·mApproximately the following fraction of resistance: 0.45%.

The lecturer’s rounded route gives pᵦ=101.8 and Mᵦ=111.6 kNm against 111.2, also a pass.

Do not claim a large reserve.

The illustrated solution checks shear, section bending and LTB; bearing dimensions are absent.

The characteristic imposed load arrangement is known, but a finish limit is not specified in this example’s question.

Those additional design conditions must be supplied before a blanket full-design conclusion.

Mechanism detailsA beam bends sideways and twists3 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. For the illustrated sagging beam the top flange is compressed.
  2. The unrestrained compression flange can move sideways while the complete cross-section twists.
  3. Only effective restraints divide the member into unbraced segments.

    They do not automatically add vertical supports.

  4. Use the segment effective length, section properties and matching moment factor.

    This is an exaggerated mode shape, not a calculated displacement.

Result and concise exam wording

Use the same mechanism: Vertical bending can trigger sideways motion. Adding a valid lateral restraint shortens a stability segment. It need not change the beam’s vertical reaction or moment diagram.

Use the same mechanism: Move between two known values. If the second strength is lower, moving toward that row must reduce the interpolated strength.

Apply the reasoning to this section’s data and conditions

Use S355 457×152×52 UB, Class 1.

Each P=50kN,w=2.8kNm,R=82kN,Mmax=121.25kN·m.

Vc=700.649kN,Mc=389.08kN·m.

LE=5m; mLT=0.917268, demand 111.21875kN·m.

λ=160.7717, v=0.879594, λLT=121.4745; interpolate pb=101.93575Nmm2.

Mb=111.72158kN·m>111.21875; LTB passes by only a small margin.

Misconceptions and checks

Use the same mechanism: Moment shape matters within one segment. Two segments can have equal peak moment but different distributions. Their equivalent moment factors can therefore differ.

Use the same mechanism: Balance the isolated beam. Move the same load toward B. Reaction B increases because the load has a larger moment arm about A.

Apply the reasoning to this section’s data and conditions

  • Point-load positions do not imply intermediate restraints.
  • Use quarter points 1.25,2.5,3.75m, not the load positions 1,2.5,4m.
  • Read pᵦ using λᴸᵀ, not λ.
  • Do not round a narrow pass into an unsupported generous margin.

How the method transfers to a new variant

Use the same mechanism: Find which plate buckles first. At fixed width, a thinner plate has a larger width-to-thickness ratio. Local buckling then becomes more restrictive.

A safe beam can still sag too far

Check whether the beam displacement exceeds the permitted service limit.

The straight beam marks the unloaded position. The curved line and vertical arrow show downward displacement, exaggerated for explanation.
The straight beam marks the unloaded position. The curved line and vertical arrow show downward displacement, exaggerated for explanation.

Prediction, then explanation. For the same UDL and stiffness, doubling span multiplies deflection by sixteen. Doubling I halves deflection.

Load bends each beam segment. The curvature accumulates along the span. Material stiffness E and geometric stiffness I resist that deformation.

δmid=5wL4384EI\delta_{mid}=\frac{5wL^4}{384EI}

Use w in N/mm, L in mm, E in N/mm² and I in mm⁴. The resulting midspan deflection is in mm.

Scope. The formula assumes a prismatic, simply supported, linear-elastic beam with full-span UDL. Use the stated service load and deflection limit.

Check and takeaway. A higher yield grade does not automatically increase E. Passing a strength check therefore does not prove acceptable deflection.

Use the same mechanism: Vertical bending can trigger sideways motion. Adding a valid lateral restraint shortens a stability segment. It need not change the beam’s vertical reaction or moment diagram.

Apply the reasoning to this section’s data and conditions

  1. Identify the vertical supports, span, lateral restraints and individual load positions.
  2. Keep dead and imposed loads separate; form the required ultimate and serviceability cases.
  3. Find reactions and the maximum shear/moment by equilibrium, with units.
  4. Choose a section-table row, confirm thickness-dependent strength, and classify both flange and web.
  5. Check shear and bending.

    Add segment LTB where restraint is discrete.

  6. Complete the requested web and deflection checks; state the governing result and any missing data.

Prediction with explained answer

Use the same mechanism: Moment shape matters within one segment. Two segments can have equal peak moment but different distributions. Their equivalent moment factors can therefore differ.

Use the same mechanism: Vertical bending can trigger sideways motion. Adding a valid lateral restraint shortens a stability segment. It need not change the beam’s vertical reaction or moment diagram.

Use the same mechanism: Keep load categories separate. Increasing imposed load changes its own term. It does not change the dead-load factor or the steel stiffness.

Apply the reasoning to this section’s data and conditions

Prediction and explained answer.

Invented variant: all ultimate loads increase by 1%, with geometry and section unchanged.

Does the LTB check still pass?

Answer and reasoning

The moment shape and mᴸᵀ stay unchanged; resistance stays 111.72158kN·m.

Demand becomes 111.21875×1.01=112.33094kN·m, exceeding resistance.

The beam fails LTB even though section bending and shear have ample reserve.

Mechanism detailsRead the moment shape within one segment2 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Moment ordinates must belong to the same effective unbraced segment.
  2. Same-side and reverse-curvature diagrams have different signed end ratios.
  3. The markers show ¼, ½ and ¾ of this segment, not of the entire beam.
  4. LTB and column flexural factors are different.

    Preserve their individual bounds and coefficient sets.