Design a double-cover splice for an already ultimate tensile force of 700kN. Main plates are 150mm wide ×20mm thick; two S355 cover plates are 12mm thick. Use Grade 8.8 M20 bolts in 22mm holes, 50mm pitch and 40mm end distance.

Original source: LectureNotes/Ch 2_Connection.pdf — p. 18, p. 19, p. 20.

A given value comes from the question or diagram.

A lookup value comes from the named table.

A calculated value follows from the working.

Each assumption is stated where the calculation needs it.

Known information, diagram labels and unknowns

A bolt diameter is not a hole diameter

Check that bolts fit and leave enough material between holes and plate boundaries.

pdd₀Clear ligament
The inner circle represents bolt diameter d. The outer circle represents hole diameter d₀. Pitch and gauge join hole centres.

Prediction, then explanation. At fixed pitch, a larger hole leaves a shorter clear ligament. Increasing bolt diameter may also increase minimum edge-distance requirements.

Measure pitch along the bolt line and gauge across lines. Distinguish end distance along the load from edge distance across it.

lc=p−d0l_c=p-d_0

lc is clear ligament between holes; p is centre-to-centre pitch; d₀ is hole diameter. All use mm.

Scope. Apply the supplied edge-preparation and minimum/maximum spacing rules. Passing a bearing calculation does not prove the layout passes.

Check and takeaway. For pitch 60 mm and hole diameter 22 mm, the ligament is 38 mm. Using a 20 mm bolt diameter here gives the wrong ligament.

Change the ruler, keep the quantity

A section table uses centimetres, but the strength calculation uses millimetres. The numbers must describe the same section.

Length1 factorArea2 factors3 factorsEach centimetre becomes ten millimetres.
In the diagram, the length, square and cube contain one, two and three length factors. Each factor changes when the ruler changes.

Prediction, then explanation. Would every property increase by ten? No. The exponent determines how many factors of ten are needed.

First identify the physical quantity. Next convert each length factor. Keep force and length conversions separate when converting a moment.

1 cmn=10n mmn,1 kN m=106 N mm1\,\mathrm{cm}^n=10^n\,\mathrm{mm}^n,\qquad 1\,\mathrm{kN\,m}=10^6\,\mathrm{N\,mm}

Here n is the length exponent: 2 for area, 3 for section modulus and 4 for second moment of area.

Scope. Changing units changes neither the load nor the section. A conversion factor cannot repair a formula for the wrong physical quantity.

Check and takeaway. Illustration: 2 cm4=20,000 mm42\,\mathrm{cm}^4=20{,}000\,\mathrm{mm}^4. The fourth power belongs to the unit, not the number 2.

A table value has conditions

Find a design property without mixing a row, column or standard from a different case.

The row and column meet at one cell. The table heading supplies the units and the conditions that give the cell meaning.
The row and column meet at one cell. The table heading supplies the units and the conditions that give the cell meaning.

Prediction, then explanation. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Match the complete section designation. Read the relevant axis and unit. For strength tables, select material, thickness and curve before interpolating.

Given values come from the question. Lookup values come from a named table. Assumed values require an explicit condition.

Scope. A missing row or omitted restraint cannot be recovered from a schematic’s scale. Keep the result conditional when required data are absent.

Check and takeaway. Record the table, row, column and unit beside the substitution. That makes a later check possible.

Apply the reasoning to this section’s data and conditions

InputOrigin
Given demand

700kN ultimate.

No further factor.

Given thicknesses

Main t2=20mm.

Each cover t1=12mm; cross-section view labels each ply.

Given hole/pitch/endM20 → d=20; stated hole d0=22; longitudinal pitch 50; end 40mm.
Selected layoutp.19 drawing: two rows, gauge 90mm, side edges 30mm, two columns per half-splice.
Lookup

As=245mm2, ps=375, pbb=1,000; S355 pbs=550, Us=510, Ke=1.1.

Main py=345 for 20mm; covers py=355 for 12mm.

All stress units Nmm2.

Why this method applies

Count cuts through each loaded bolt

Find how many shear planes transfer the force through one side of the connection.

The middle plate moves against two cover plates. The two interfaces cut each bolt at two planes.
The middle plate moves against two cover plates. The two interfaces cut each bolt at two planes.

Prediction, then explanation. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Select the area at the actual shear plane. Multiply by bolt shear strength. Count only the bolts and planes in the same transfer stage.

Ps=psAs,Pgroup=nbnsPsP_s=p_sA_s,\qquad P_{group}=n_b n_s P_s

ps is bolt shear strength in N/mm²; As is the appropriate area in mm². nb counts bolts; ns counts equally loaded shear planes.

Scope. Use the thread area when threads cross the plane as required. Check bearing, plate failure and detailing separately.

Check and takeaway. Both halves of a butt splice carry the full transmitted force in sequence. Counting both halves together would double the apparent resistance.

Follow contact pressure into the plate

The bolt may survive shear while the connected plate deforms or tears near the hole.

The labels distinguish bolt diameter d from hole diameter d₀. The arrow at the hole edge shows the bearing contact action.
The labels distinguish bolt diameter d from hole diameter d₀. The arrow at the hole edge shows the bearing contact action.

Prediction, then explanation. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.

Calculate every bound required by the supplied rule. The smallest applicable bound limits the connection at that layer.

Pbearing≤pbsdtP_{bearing}\le p_{bs}dt

pbs is the applicable bearing strength in N/mm²; d is nominal bolt diameter in mm; t is plate thickness in mm.

Scope. This diameter term alone is not the complete check. End-distance and clear-ligament limits, bolt bearing and each connected layer also matter.

Check and takeaway. Two covers and one main plate do not necessarily have the same thickness or strength. Compare the actual force share in each layer.

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

Each half-splice must transfer the full 700kN from a main plate into the covers.

The covers each take half that force.

Bolts have two shear planes; compare main thickness 20 with total cover thickness 24 for the bearing path.

Select bolt count from the weakest per-bolt mode, round up, arrange the bolts, then check the plates cut by those holes.

1. Establish the capacity of one bolt and its bearing path

Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.

Use the same mechanism: A bolt diameter is not a hole diameter. At fixed pitch, a larger hole leaves a shorter clear ligament. Increasing bolt diameter may also increase minimum edge-distance requirements.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Count where the bolt can be sheared

The plate interfaces are the places trying to cut across the bolt.

Count where the bolt can be sheared — The plate interfaces are the places trying to cut across the bolt.

Sketch, not to scale; use the original dimensions.

  1. Count actual loaded shear planes, not merely visible plates.
  2. Choose shank or threaded area for the plane concerned.
  3. Compare group resistance with the force that group transfers.

Remember: Bolts on opposite sides of a splice do not all act in parallel.

Related concept and full method

Double shear: Ps=2×375×2451,000=183.75kNtp=min(20,2×12)=20mmBolt bearing: Pbb=20×20×1,0001,000=400kNlc=pitch−hole diameter=50−22=28mmB1=1×20×20×5501,000=220kNB2=0.5×1×40×20×5501,000=220kNNet-clearance term between holes: 1.5×28×20×5101,000=428.4kNUpper cap: 2×20×20×8001,000=640kNConnected-plate resistance: min(220,220,428.4,640)=220kNGoverning resistance per bolt: min(183.75,400,220)=183.75kN

Using total cover thickness 24 is valid here because the two identical covers share the force symmetrically.

An unequal cover arrangement would need separate load-sharing checks.

Mechanism detailsCount the bolt shear planes4 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Load must cross an interface between the connected plates.
  2. A lap joint gives one shear plane through a bolt.
  3. A symmetric double-cover joint may provide two shear planes.

    Count load-transfer interfaces, not just visible plates.

  4. Use the source’s area and shear strength.

    Then check bearing, plate resistance and detailing separately.

2. Select bolts on each side of the splice

Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Apply the reasoning to this section’s data and conditions

n≥700183.75=3.80952→ Select 4 bolts per half-joint. Resistance per half: 4×183.75=735kN>700kNDemand per bolt: 7004=175kN<183.75kN

Provide four on the left and four on the right: eight physical bolts in total.

The eight do not jointly give “1,470kN” across the splice, because the left and right groups carry the same force in series.

Mechanism detailsCount the bolt shear planes1 concept · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Load must cross an interface between the connected plates.
  2. A lap joint gives one shear plane through a bolt.
  3. A symmetric double-cover joint may provide two shear planes.

    Count load-transfer interfaces, not just visible plates.

  4. Use the source’s area and shear strength.

    Then check bearing, plate resistance and detailing separately.

3. Verify the selected layout

Use the same mechanism: A bolt diameter is not a hole diameter. At fixed pitch, a larger hole leaves a shorter clear ligament. Increasing bolt diameter may also increase minimum edge-distance requirements.

Apply the reasoning to this section’s data and conditions

The two transverse rows are separated by 90mm.

Width closure:30+90+30=150mm.

Longitudinal pitch 50 and end 40 are the specified values.

Use the source’s rolled-edge condition in Table 9.3, M20 row: minimum 26mm.

Minimum pitch: 2.5×20=50mm≤provided50Maximum pitch/gauge: min(12×12,150)=144mm50 and 90≤144. General minimum gauge: 3×20=60mm<90The minimum end/edge distance requirement is 26mm. The provided end and edge distances respectively satisfy 26mm<40mm26mm<30mmMaximum cover-plate edge distance: 11×12×275355=116.18mm>30Maximum main-plate edge distance: 11×20×275345=196.42mm>30

Mechanism detailsBolt centres, holes and edges1 concept · 3 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Hole diameter d₀ differs from nominal bolt diameter d.

    Net-section deductions use the specified hole.

  2. Pitch runs along the load direction; gauge measures spacing across rows.
  3. End and edge distances start at the hole centre.

    The remaining ligament starts at the hole boundary.

  4. Minimum spacing, edge distances, grip and plate thickness come from the specified rules, not this scaled illustration.

4. Check main-plate tension across two holes

Test every possible fracture cut

Find the remaining steel area across a candidate tension-failure path.

The dashed fracture line crosses two hole centres. Subtract only the holes crossed by that candidate line.
The dashed fracture line crosses two hole centres. Subtract only the holes crossed by that candidate line.

Prediction, then explanation. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.

Subtract the hole widths crossed by the path, then multiply by thickness. Compare all plausible paths using the applicable course rule.

An=(b−nd0)tA_n=(b-nd_0)t

An is net area in mm²; b is plate width; d₀ is hole diameter; t is thickness, all in mm. n counts holes on this straight path.

Scope. This expression is for a straight cut. Effective area can require further shear-lag rules. Gross, net and effective areas must remain distinct.

Check and takeaway. Use the hole diameter, not the bolt diameter, when removing missing steel. The plate contains a hole, not solid steel around the bolt shank.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Why holes reduce tension resistance

The pull must squeeze through the steel left beside the holes.

Why holes reduce tension resistance — The pull must squeeze through the steel left beside the holes.

Sketch, not to scale; use the original dimensions.

  1. Choose a possible fracture line across the member.
  2. Subtract the holes crossed by that line using hole diameter.
  3. Apply the course effective-area rule and its gross-area limit.

Remember: Do not subtract every hole anywhere in the connection.

Related concept and full method

The critical straight transverse line crosses one hole in each row: two 22mm holes.

Do not deduct all four holes along a half-splice.

Thickness 20mm selects py=345Nmm2.

Ag=150×20=3,000mm2An=(150−2×22)×20=106×20=2,120mm2Ae=min(1.1×2,120,3,000)=2,332mm2Pt=2,332×3451,000=804.54kN>700Passes.

Mechanism detailsSubtract holes on the failure path1 concept · 2 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Gross area counts the complete plate width and thickness.
  2. The highlighted transverse path passes through the bolt holes.
  3. For the straight illustrative path, .

    Staggered paths require their specified correction.

  4. Net area is not always effective area.

    Include the course’s strength ratio or shear-lag rule when applicable.

5. Check both covers and conclude

Use the same mechanism: Test every possible fracture cut. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.

Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Apply the reasoning to this section’s data and conditions

Each cover plate: Ag=150×12=1,800mm2An=(150−44)×12=1,272mm2Ae=min(1.1×1,272,1,800)=1,399.2mm2Pt=1,399.2×3551,000=496.716kN>350kNBoth plates together: Pt=2×496.716=993.432kN>700kN

All requested checks pass under the stated rolled-edge layout.

The least load-path resistance is bolt shear 735kN.

The source gives approximately 993.2kN for covers after intermediate rounding; carrying full precision gives 993.43kN.

Mechanism detailsSubtract holes on the failure path2 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. Gross area counts the complete plate width and thickness.
  2. The highlighted transverse path passes through the bolt holes.
  3. For the straight illustrative path, .

    Staggered paths require their specified correction.

  4. Net area is not always effective area.

    Include the course’s strength ratio or shear-lag rule when applicable.

Result and concise exam wording

Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Use the same mechanism: Test every possible fracture cut. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.

Use the same mechanism: A bolt diameter is not a hole diameter. At fixed pitch, a larger hole leaves a shorter clear ligament. Increasing bolt diameter may also increase minimum edge-distance requirements.

Apply the reasoning to this section’s data and conditions

Four M20 Grade 8.8 bolts per side (eight total), two rows with 90mm gauge,50mm pitch,40mm ends and 30mm rolled edges.

Double-shear resistance 735kN per half; bearing exceeds this.

Main tension 804.54kN; combined cover tension 993.43kN.

Each exceeds 700kN.

Layout passes for the source’s rolled-edge assumption.

Misconceptions and checks

Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Use the same mechanism: Test every possible fracture cut. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

  • Do not factor the already ultimate 700kN.
  • Four bolts are required on each side of the plate butt.
  • Double shear doubles bolt shear, not the main-plate thickness.
  • A transverse net section crosses two holes, not four.

How the method transfers to a new variant

Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.

Use the same mechanism: Test every possible fracture cut. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.

Apply the reasoning to this section’s data and conditions

  1. Trace one half-splice at full force and each cover at its share.
  2. Calculate per-bolt shear/bearing and take the minimum.
  3. Round up bolt count and draw a feasible layout.
  4. Check every pitch/edge rule using the thinner ply and correct edge finish.
  5. Check main and cover effective tension areas independently.

Prediction with explained answer

Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Use the same mechanism: Test every possible fracture cut. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.

Apply the reasoning to this section’s data and conditions

Prediction and explained answer.

If the required ultimate force becomes 760kN but the splice is unchanged, which calculated resistance fails first?

Hint

Compare 760 with the complete group resistance, not just one bolt.

Answer and reasoning

Bolt shear 735kN is inadequate.

Main-plate tension 804.54kN and cover-pair tension 993.43kN still exceed 760.

Adding bolts changes the layout and may change the fracture path, so repeat layout/net-area checks.