STEELWORK / CON4334
Worked examples

Connection example 10: welded splice and a minimum-size discrepancy

Diagrams, explanations and answers are presented in reading order. No playback or response is required.

← Read this lecture example beside its chapter concepts

All answers shownChinese–English terminology
Diagrams, explanations and answers are presented in reading order. No playback or response is required.

Design a welded double-cover splice transferring 700kN ultimate tension between 150×20mm S355 main plates. Cover thickness is 12mm. Use Class 42 electrode. Explain the lecturer’s 6mm-weld solution, then reconcile it with the chapter’s minimum weld-size table.

Original source: LectureNotes/Ch 2_Connection.pdf — p. 43, p. 44.

A given value comes from the question or diagram.

A lookup value comes from the named table.

A calculated value follows from the working.

Each assumption is stated where the calculation needs it.

Known information, diagram labels and unknowns

A table value has conditions

Find a design property without mixing a row, column or standard from a different case.

The row and column meet at one cell. The table heading supplies the units and the conditions that give the cell meaning.
The row and column meet at one cell. The table heading supplies the units and the conditions that give the cell meaning.

Prediction, then explanation. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Match the complete section designation. Read the relevant axis and unit. For strength tables, select material, thickness and curve before interpolating.

Given values come from the question. Lookup values come from a named table. Assumed values require an explicit condition.

Scope. A missing row or omitted restraint cannot be recovered from a schematic’s scale. Keep the result conditional when required data are absent.

Check and takeaway. Record the table, row, column and unit beside the substitution. That makes a later check possible.

Apply the reasoning to this section’s data and conditions

InputOrigin
Given demand

700kN ultimate.

Do not factor again.

Given platesMain width 150mm and thickness 20mm; two covers 12mm thick.
Selected cover widthLecturer chooses 100mm to leave flat room for edge welds; not a given dimension.
Lookup

S355 py=345 for 20mm main,355 for 12mm covers.

pw=250Nmm2 for Class 42.

Detailing lookup

Chapter 2 p.33 Table 9.1: thicker part over 19mm requires minimum leg 8mm.

Here the thicker connected main plate is 20mm.

Why this method applies

Test every possible fracture cut

Find the remaining steel area across a candidate tension-failure path.

The dashed fracture line crosses two hole centres. Subtract only the holes crossed by that candidate line.
The dashed fracture line crosses two hole centres. Subtract only the holes crossed by that candidate line.

Prediction, then explanation. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.

Subtract the hole widths crossed by the path, then multiply by thickness. Compare all plausible paths using the applicable course rule.

An=(b−nd0)tA_n=(b-nd_0)t

An is net area in mm²; b is plate width; d₀ is hole diameter; t is thickness, all in mm. n counts holes on this straight path.

Scope. This expression is for a straight cut. Effective area can require further shear-lag rules. Gross, net and effective areas must remain distinct.

Check and takeaway. Use the hole diameter, not the bolt diameter, when removing missing steel. The plate contains a hole, not solid steel around the bolt shank.

The weld resists through its throat

Convert a visible fillet leg into resistance per effective length.

The two outer sides are the legs. The shorter perpendicular line through the ideal triangle is the throat.
The two outer sides are the legs. The shorter perpendicular line through the ideal triangle is the throat.

Prediction, then explanation. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

For the course right-angle equal-leg fillet, take throat as 0.7 times leg. Multiply throat area per unit length by weld strength.

a=0.7s,qcap=0.7spw/1000a=0.7s,\qquad q_{cap}=0.7sp_w/1000

s and a are leg and throat in mm. pw is weld strength in N/mm². qcap is resistance in kN/mm.

Scope. Use effective length, the correct steel/electrode strength and permitted leg limits. Full-penetration butt welds use a different model.

Check and takeaway. Illustration: a 6 mm leg at 250 N/mm² gives 0.7(6)(250)/1000=1.05 kN/mm0.7(6)(250)/1000=1.05\,\mathrm{kN/mm}.

Apply the reasoning to this section’s data and conditions

The force enters one half-splice from the main plate and divides equally between two covers.

Each cover has two longitudinal weld runs, so four runs share the 700kN on each side of the butt.

Size runs using effective length, check laps/returns and check unperforated plate tension.

The lecturer’s strength arithmetic is reproducible, but a final choice must also satisfy the supplied minimum-size rule.

1. Select and interpret the covers

Follow tension through the intact plate

Check a plate region without bolt holes under the stated axial tension model.

btPPOne resisting cut: area = width × thickness
The cut rectangle has width b and thickness t. The load passes through this resisting area.

Prediction, then explanation. For unchanged strength and uniform stress, doubling width doubles the area and its yield resistance.

Calculate the resisting area. Multiply by the applicable design strength. Compare that resistance with the force carried by this plate.

A=bt,Pt=pyAA=bt,\qquad P_t=p_yA

b and t use mm; A uses mm²; py uses N/mm². The product gives resistance in N.

Scope. This simple expression does not include holes, shear lag, eccentric bending or other required connection checks.

Check and takeaway. If two identical covers share the load symmetrically, each carries half. The main plate still carries the total force before the split.

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

Selected cover-plate width =100mm. Allowance on each side: 150−1002=25mm

This is an explicit design choice providing space to place the weld on the main plate.

Two 12mm covers have combined thickness 24mm but are checked individually at half force 350kN.

The source uses the full welded plate area: no bolt-hole deductions.

Mechanism detailsTension through an unperforated plate2 concepts · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. For this concentric, unperforated plate, the full width and thickness form the resisting section.

    There are no bolt holes to deduct.

  2. The illustrative width is 100 mm.

    Adjust thickness t: , in .

  3. Using illustrative , in kN.

    Use the actual material and thickness band for the original question.

  4. The covers are moved apart for visibility.

    A symmetric pair each carries half the force.

    Check the main plate, each cover and the welds separately.

2. Reproduce the lecturer’s strength calculation

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Drawn length and useful length differ

The start and end of a weld are not credited as fully effective in this course model.

Drawn length and useful length differ — The start and end of a weld are not credited as fully effective in this course model.

Sketch, not to scale; use the original dimensions.

  1. Find the effective length required by strength.
  2. Add the specified end allowance to each separate run.
  3. Round up, then check minimum size, spacing and returns.

Remember: Strength alone does not prove a weld detail is acceptable.

Related concept and full method

The source trials s=6mm: q=0.7×6×2501,000=1.05kNmmRequired total effective length per half: 7001.05=666.6667mm4 welds each require effective length: 666.66674=166.6667mmActual length per weld: ≥166.6667+2×6=178.6667mm→180mmProvided effective length per weld: 180−12=168mmHalf-splice resistance: 4×168×1.05=705.6kN>700kN

The four runs on the other side of the butt transfer the same 700kN in series.

Do not add both halves to claim 1,411.2kN splice resistance.

Mechanism detailsFrom fillet leg to effective throat1 concept · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat .

    It is shorter than the leg.

  3. Effective resisting area = .

    With here, capacity per length is .

  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.

3. Reconcile the minimum-size table and give a corrected detail

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

The lecturer checks lap≥5×12=60mm, physical run 180≥100mm transverse spacing, and returns 15≥2×6=12mm.

However the 20mm main plate triggers the 8mm minimum in Table 9.1 on p.33.

The 6mm selection is inconsistent with that supplied table.

Select s=8mm: q=0.7×8×2501,000=1.40kNmmRequired effective length per weld: 7004×1.40=125mmActual length: ≥125+2×8=141mm→select145mmProvided effective length: 145−16=129mmResistance per half: 4×129×1.40=722.4kN>700Minimum effective length: max(4×8,40)=40mm<129Lap length: 145mm≥max(5×12,25)=60mmActual weld length 145mm≥100mm transverse spacing. Provide end return 20mm≥2×8=16mm. 12mm cover-plate edge, maximum weld leg =12−2=10mm≥8mm.

The corrected detail uses 8mm fillets,145mm physical longitudinal runs on each half of each cover edge, and 20mm returns.

This is an authored correction, clearly distinguished from the lecturer’s dimensions.

Mechanism detailsFrom fillet leg to effective throat2 concepts · 4 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat .

    It is shorter than the leg.

  3. Effective resisting area = .

    With here, capacity per length is .

  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.

4. Verify main and cover plate tension

Use the same mechanism: Follow tension through the intact plate. For unchanged strength and uniform stress, doubling width doubles the area and its yield resistance.

Apply the reasoning to this section’s data and conditions

Physical interpretation: Why holes reduce tension resistance

The pull must squeeze through the steel left beside the holes.

Why holes reduce tension resistance — The pull must squeeze through the steel left beside the holes.

Sketch, not to scale; use the original dimensions.

  1. Choose a possible fracture line across the member.
  2. Subtract the holes crossed by that line using hole diameter.
  3. Apply the course effective-area rule and its gross-area limit.

Remember: Do not subtract every hole anywhere in the connection.

Related concept and full method

Main plate: A=150×20=3,000mm2Pt=3,000×3451,000=1,035kN>700Each cover plate: A=100×12=1,200mm2Pt=1,200×3551,000=426kN>350Both plates together: Pt=2×426=852kN>700

The corrected welded load path is governed by 722.4kN weld resistance, above 700kN.

Main and cover tension pass.

Every area is unperforated, so it equals the effective area for this concentric plate connection.

Mechanism detailsTension through an unperforated plate1 concept · 1 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. For this concentric, unperforated plate, the full width and thickness form the resisting section.

    There are no bolt holes to deduct.

  2. The illustrative width is 100 mm.

    Adjust thickness t: , in .

  3. Using illustrative , in kN.

    Use the actual material and thickness band for the original question.

  4. The covers are moved apart for visibility.

    A symmetric pair each carries half the force.

    Check the main plate, each cover and the welds separately.

Result and concise exam wording

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

Source arithmetic:6mm fillets,180mm physical runs give 705.6kN per half; plates give 1,035kN main and 852kN cover pair.

But Table 9.1 requires 8mm for the 20mm thicker part.

Corrected detail:8mm fillets,145mm physical runs on each of four runs per half,20mm returns.

Effective length 129mm/run gives 722.4kN; lap, length and edge-leg limits pass.

Misconceptions and checks

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

  • Four parallel runs occur on each half-splice; opposite halves are in series.
  • The cover width 100mm is selected, not the 150mm main width.
  • Strength adequacy does not override the supplied minimum weld-size table.
  • Increasing leg size changes the 2s length deduction.

How the method transfers to a new variant

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

  1. Select cover width with room for welds and check plate strength.
  2. Count parallel weld runs on one transfer side only.
  3. Find required effective length, add 2s and round up.
  4. Check minimum/maximum leg, lap, returns and transverse-spacing rules.
  5. Resolve source discrepancies explicitly and verify the corrected detail.

Prediction with explained answer

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

Prediction and explained answer.

For the corrected 8mm welds, would 140mm physical longitudinal runs be sufficient?

Hint

Recompute effective length after selecting the physical length.

Answer and reasoning

Effective length 140−16=124mm.

Resistance=4×124×1.40=694.4kN<700kN, so no.

Rounding the 141mm minimum down to 140mm loses required capacity.

Mechanism detailsFrom fillet leg to effective throat1 concept · 2 source expressions

The complete mechanism is explained below.

Read each stage together with its stated conditions; playback and interaction are not required.

  1. An equal-leg fillet between perpendicular plates has an approximately right-triangular section.
  2. For this geometry, throat .

    It is shorter than the leg.

  3. Effective resisting area = .

    With here, capacity per length is .

  4. Use the course end allowances, minimum size and length rules; increasing the geometric length alone does not resolve every detailing check.