Connection example 1: single bolted unequal angle
← Read this lecture example beside its chapter concepts
Check a single S355 angle connected through its long leg to a plate by the stated two Grade 8.8 M20 bolts. Dead tension is ; imposed tension is . Check bolt shear, bolt/plate bearing and angle tension.
Original source: LectureNotes/Ch 2_Connection.pdf — p. 16, p. 17.
A given value comes from the question or diagram.
A lookup value comes from the named table.
A calculated value follows from the working.
Each assumption is stated where the calculation needs it.
Known information, diagram labels and unknowns
Count cuts through each loaded bolt
Find how many shear planes transfer the force through one side of the connection.
Prediction, then explanation. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.
Select the area at the actual shear plane. Multiply by bolt shear strength. Count only the bolts and planes in the same transfer stage.
ps is bolt shear strength in N/mm²; As is the appropriate area in mm². nb counts bolts; ns counts equally loaded shear planes.
Scope. Use the thread area when threads cross the plane as required. Check bearing, plate failure and detailing separately.
Check and takeaway. Both halves of a butt splice carry the full transmitted force in sequence. Counting both halves together would double the apparent resistance.
Test every possible fracture cut
Find the remaining steel area across a candidate tension-failure path.
Prediction, then explanation. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.
Subtract the hole widths crossed by the path, then multiply by thickness. Compare all plausible paths using the applicable course rule.
An is net area in mm²; b is plate width; d₀ is hole diameter; t is thickness, all in mm. n counts holes on this straight path.
Scope. This expression is for a straight cut. Effective area can require further shear-lag rules. Gross, net and effective areas must remain distinct.
Check and takeaway. Use the hole diameter, not the bolt diameter, when removing missing steel. The plate contains a hole, not solid steel around the bolt shank.
A bolt diameter is not a hole diameter
Check that bolts fit and leave enough material between holes and plate boundaries.
Prediction, then explanation. At fixed pitch, a larger hole leaves a shorter clear ligament. Increasing bolt diameter may also increase minimum edge-distance requirements.
Measure pitch along the bolt line and gauge across lines. Distinguish end distance along the load from edge distance across it.
lc is clear ligament between holes; p is centre-to-centre pitch; d₀ is hole diameter. All use mm.
Scope. Apply the supplied edge-preparation and minimum/maximum spacing rules. Passing a bearing calculation does not prove the layout passes.
Check and takeaway. For pitch 60 mm and hole diameter 22 mm, the ligament is 38 mm. Using a 20 mm bolt diameter here gives the wrong ligament.
Apply the reasoning to this section’s data and conditions
| Input | Value and exact source |
|---|---|
| Given loads | dead and imposed, question text. The downward arrow is the resulting tension direction. |
| Given geometry | Long leg ; short leg ; . The split dimensions and allocate half the heel thickness to each leg. |
| Given fasteners | Text specifies TWO M20 Grade 8.8 bolts; standard holes; pitch; end distance. |
| Given plate/model | supporting plate; one shear plane explicitly stated. |
| Lookup | Ch 2 p.3 M20 tensile stress area . Ch 2 pp.9–10 Grade 8.8: , , . S355: , , . Data File p.1, thickness : . |
Why this method applies
Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.
Follow contact pressure into the plate
The bolt may survive shear while the connected plate deforms or tears near the hole.
Prediction, then explanation. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.
Calculate every bound required by the supplied rule. The smallest applicable bound limits the connection at that layer.
pbs is the applicable bearing strength in N/mm²; d is nominal bolt diameter in mm; t is plate thickness in mm.
Scope. This diameter term alone is not the complete check. End-distance and clear-ligament limits, bolt bearing and each connected layer also matter.
Check and takeaway. Two covers and one main plate do not necessarily have the same thickness or strength. Compare the actual force share in each layer.
Use the same mechanism: Test every possible fracture cut. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.
Apply the reasoning to this section’s data and conditions
This is concentric tension through one connected angle leg.
The load crosses the angle-to-plate interface as bolt shear, presses on holes as bearing, and remains tension in the angle.
Start with the factored force.
Check each fastener mode, then the reduced angle tension resistance.
Prerequisites: stress×area gives force; “net area” removes holes.
A single-leg connection needs the specific unconnected-leg reduction.
1. Convert characteristic loads to one design force
Keep load categories separate
A floor carries permanent material and changing occupancy loads. Find the design load for the stated check.
Prediction, then explanation. Increasing imposed load changes its own term. It does not change the dead-load factor or the steel stiffness.
First convert mass to weight where required. Next collect G and Q in compatible units. Apply the combination specified by the course problem.
G is characteristic dead load; Q is characteristic imposed load. Wu is the design load for this course gravity combination.
Scope. This combination is not universal. Use the specified service load for deflection and the stated factors for other standards or cases.
Check and takeaway. Illustration: G = 10 kN and Q = 5 kN give 22 kN. Factoring their sum by one guessed factor loses the distinction.
Apply the reasoning to this section’s data and conditions
is the ULS tensile demand in .
Apply the course gravity factors once.
The supplied loads are characteristic, not already ultimate.
Mechanism detailsFrom characteristic to design load
The complete mechanism is explained below.
Read each stage together with its stated conditions; playback and interaction are not required.
G is permanent load; Q is imposed load.
A surface load and a line load also have different units.
This illustration uses the course gravity case .
Other combinations in the original text retain their own factors.
- For illustrative , the separate load contributions show what changes when Q increases.
Do not carry this ULS total automatically into deflection.
Follow the stated SLS load case.
2. Bolt shear across the single interface
Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.
Apply the reasoning to this section’s data and conditions
Physical interpretation: Count where the bolt can be sheared
The plate interfaces are the places trying to cut across the bolt.
Sketch, not to scale; use the original dimensions.
- Count actual loaded shear planes, not merely visible plates.
- Choose shank or threaded area for the plane concerned.
- Compare group resistance with the force that group transfers.
Remember: Bolts on opposite sides of a splice do not all act in parallel.
is the tensile stress area because no thread-free shear plane is guaranteed.
There is one interface between the angle leg and the support plate, so no factor for double shear.
Mechanism detailsCount the bolt shear planes
The complete mechanism is explained below.
Read each stage together with its stated conditions; playback and interaction are not required.
- Load must cross an interface between the connected plates.
- A lap joint gives one shear plane through a bolt.
A symmetric double-cover joint may provide two shear planes.
Count load-transfer interfaces, not just visible plates.
Use the source’s area and shear strength.
Then check bearing, plate resistance and detailing separately.
3. Bearing of the bolts
Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.
Apply the reasoning to this section’s data and conditions
Physical interpretation: The bolt can crush or tear the plate
A strong bolt can still push through a weak hole edge.
Sketch, not to scale; use the original dimensions.
- Check the bolt and each connected plate’s bearing bounds.
- Use nominal bolt diameter for bearing; hole size for removed material.
- The smallest applicable resistance controls.
Remember: A short end distance may govern even when bolt shear passes.
Use the thinner connected thickness : the angle leg governs.
is the bolt diameter, not the hole.
Mechanism detailsBearing and the remaining ligament
The complete mechanism is explained below.
Read each stage together with its stated conditions; playback and interaction are not required.
- Force transfers through contact between bolt and connected plate.
The plate around the hole carries bearing stress.
Bolt bearing and plate bearing are separate checks.
A short ligament can tear out towards the end.
The direction of force determines the relevant edge.
- Evaluate every specified bearing and ligament bound for each layer and retain the smallest applicable resistance.
4. Bearing and ligament resistance of the angle leg
Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.
Apply the reasoning to this section’s data and conditions
The dimension is centre-to-centre pitch along tension.
Subtract one full hole diameter to get the clear inter-hole ligament .
The dimension is end distance from end to nearest bolt centre.
Plate bearing is closer to its limit than bolt shear: utilisation.
This is why the larger bolt-bearing value cannot be used as the joint’s governing resistance.
Mechanism detailsBearing and the remaining ligament
The complete mechanism is explained below.
Read each stage together with its stated conditions; playback and interaction are not required.
- Force transfers through contact between bolt and connected plate.
The plate around the hole carries bearing stress.
Bolt bearing and plate bearing are separate checks.
A short ligament can tear out towards the end.
The direction of force determines the relevant edge.
- Evaluate every specified bearing and ligament bound for each layer and retain the smallest applicable resistance.
5. Effective angle area and single-leg reduction
One connected leg does not load both legs equally
An angle carries tension through only one leg. Determine how much section area the design rule permits.
Prediction, then explanation. Keeping the same gross area does not guarantee the same tension resistance when the connection arrangement changes.
Separate connected and outstanding leg areas. Include the actual holes. Then use the supplied single-angle or double-angle effective-area rule.
Ae is the effective area from the applicable angle rule in mm². py is the relevant design strength in N/mm².
Scope. Do not assume the whole gross area is effective. Symmetry, connected leg and connection type determine which rule applies.
Check and takeaway. The outstanding leg contributes through load transfer; the rule need not either count all of it or discard all of it.
Apply the reasoning to this section’s data and conditions
Physical interpretation: One connected leg does not load both legs equally
The connected leg receives the pull first.
The other leg receives it through the angle.
Sketch, not to scale; use the original dimensions.
- Identify connected and outstanding legs from the drawing.
- Use the relevant bolted or welded angle rule.
- Keep the lecturer’s area convention consistent.
Remember: Bolted and welded reduction expressions are not the same rule.
Use the lecturer’s rectangular leg-area approximation.
The heel is shared: connected leg width ; unconnected width .
A transverse fracture line crosses one hole, not both bolts arranged along the member.
Apply separately to each leg and cap each at its own gross area.
The factor belongs specifically to a single bolted angle connected through one leg (Ch 2 p.14).
It is not a generic reduction for all tension members.
Mechanism detailsWhy a connected angle leg matters
The complete mechanism is explained below.
Read each stage together with its stated conditions; playback and interaction are not required.
- Locate the connected leg, outstanding leg and centroid before using the table.
- Only the connected leg directly receives the fastener force.
The outstanding area may not become equally effective at the same section.
This motivates the effective-area rule.
Bolted, welded, single-angle and double-angle details can have different rules.
Preserve the formula attached to the original case.
6. State the governing result and the scope
Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.
Use the same mechanism: One connected leg does not load both legs equally. Keeping the same gross area does not guarantee the same tension resistance when the connection arrangement changes.
Use the same mechanism: A bolt diameter is not a hole diameter. At fixed pitch, a larger hole leaves a shorter clear ligament. Increasing bolt diameter may also increase minimum edge-distance requirements.
Apply the reasoning to this section’s data and conditions
For the requested resistance checks, the minimum is plate bearing , above .
The angle tension check also passes.
Units close correctly: stress× gives before dividing by .
The pitch equals and is less than .
The end distance exceeds both supplied M20 minimum values ( or ).
The transverse edge distances are not fully dimensioned in this example, so these observations do not prove that the entire arrangement has been verified.
Mechanism detailsFollow the calculation sequence
The complete mechanism is explained below.
Read each stage together with its stated conditions; playback and interaction are not required.
- Locate the load, supports, connection geometry and any stated assumptions.
- Keep given values, table lookups and calculated values distinct; reconcile their units.
- The calculation player steps through the existing expressions in their original order.
Compare demand with resistance or the relevant limit.
Keep missing inputs and conditional conclusions explicit.
Result and concise exam wording
Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.
Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.
Use the same mechanism: One connected leg does not load both legs equally. Keeping the same gross area does not guarantee the same tension resistance when the connection arrangement changes.
Apply the reasoning to this section’s data and conditions
.
Two bolts in single shear: ; bolt bearing ; angle bearing .
; single angle .
All required resistances exceed the demand.
Plate bearing governs, using the two-bolt model specified by the question.
Misconceptions and checks
Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.
Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.
Apply the reasoning to this section’s data and conditions
Do not multiply by two for shear planes.
The given joint is single shear.
- Subtract for a hole, use for bearing.
- Do not multiply the unconnected gross leg area by without its gross-area cap.
- Do not silently replace the written two bolts with four based on the inconsistent sketch.
How the method transfers to a new variant
Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.
Use the same mechanism: Keep load categories separate. Increasing imposed load changes its own term. It does not change the dead-load factor or the steel stiffness.
Apply the reasoning to this section’s data and conditions
- Read the written bolt count and the interface geometry; reconcile any discrepancy.
- Factor characteristic loads and distribute concentric load to the bolts.
- Check shear, bolt bearing and all connected-part bounds.
- Compute gross/net/effective leg areas and the correct single/double connection reduction.
- Compare each complete load path with the same demand and name the governing one.
Prediction with explained answer
Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.
Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.
Use the same mechanism: Test every possible fracture cut. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.
Apply the reasoning to this section’s data and conditions
Prediction and explained answer.
Keep the geometry but increase imposed load to .
Does the connection still pass the calculated strength checks?
Hint
Recalculate demand only.
The capacities do not change when geometry and materials stay the same.
Answer and reasoning
New .
Plate bearing and bolt shear are both inadequate; angle tension still passes.
A stronger angle alone would not fix the fastener path.
Mechanism detailsCount the bolt shear planes
The complete mechanism is explained below.
Read each stage together with its stated conditions; playback and interaction are not required.
- Load must cross an interface between the connected plates.
- A lap joint gives one shear plane through a bolt.
A symmetric double-cover joint may provide two shear planes.
Count load-transfer interfaces, not just visible plates.
Use the source’s area and shear strength.
Then check bearing, plate resistance and detailing separately.