Assignment 1 Q3: one-sided rectangular weld group
Determine the fillet-weld leg for the bracket’s four welded edges. One side plate carries characteristic dead and imposed . Steel S355, electrode Class 42; rectangular group wide by high; load eccentricity from the group centreline.
Original source: Assignment/AY2627s 1-CON4334-Assignment 1.pdf — p. 2.
A given value comes from the question or diagram.
A lookup value comes from the named table.
A calculated value follows from the working.
Each assumption is stated where the calculation needs it.
Known information, diagram labels and unknowns
The weld resists through its throat
Convert a visible fillet leg into resistance per effective length.
Prediction, then explanation. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.
For the course right-angle equal-leg fillet, take throat as 0.7 times leg. Multiply throat area per unit length by weld strength.
s and a are leg and throat in mm. pw is weld strength in N/mm². qcap is resistance in kN/mm.
Scope. Use effective length, the correct steel/electrode strength and permitted leg limits. Full-penetration butt welds use a different model.
Check and takeaway. Illustration: a 6 mm leg at 250 N/mm² gives .
A table value has conditions
Find a design property without mixing a row, column or standard from a different case.
Prediction, then explanation. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.
Match the complete section designation. Read the relevant axis and unit. For strength tables, select material, thickness and curve before interpolating.
Given values come from the question. Lookup values come from a named table. Assumed values require an explicit condition.
Scope. A missing row or omitted restraint cannot be recovered from a schematic’s scale. Keep the result conditional when required data are absent.
Check and takeaway. Record the table, row, column and unit beside the substitution. That makes a later check possible.
Apply the reasoning to this section’s data and conditions
| Quantity | Source/type |
|---|---|
| Derived ultimate ; loads labelled dead/live are characteristic despite the general introductory wording “design load”. | |
| Geometry | GivenB340,H560,e 420 mm; centroid offsetsx±170,y±280 mm calculated by rectangle symmetry. |
| Weld model | Use the course elastic line-weld method: uniform throat around a continuous closed rectangle. The S355/Class 42 table gives . |
| Unprovided inputs | Bracket thickness and column-flange thickness are not stated; minimum/maximum weld-leg detailing cannot be numerically certified. |
Why this method applies
Treat a weld group as lines
An eccentric force creates direct line force and torsional line force in the same weld group.
Prediction, then explanation. Increasing eccentricity increases the torsional contribution. The governing corner depends on vector addition, not distance alone.
Find the line centroid. Integrate squared distance along the effective lines. Add direct and torsional components at every candidate critical point.
J is line polar inertia in mm³. x and y use mm. With M in kN·mm, q is line force in kN/mm.
Scope. A solid rectangle has area inertia in mm⁴ and is not this weld-line model. Missing weld sides change the centroid and integrals.
Check and takeaway. Compare the largest resultant line force with the selected throat resistance. Keep kN/mm distinct from total force in kN.
Add force components at each bolt
An in-plane load acts away from the bolt-group centre. Find the largest resultant bolt force.
Prediction, then explanation. At fixed force, increasing eccentricity increases the moment component. Its direction differs between bolts.
Locate the bolt-group centre and coordinates. Add horizontal components together and vertical components together before finding each resultant.
e, xi and yi use mm; J uses mm². With M in kN·mm, each moment-force component is in kN.
Scope. These expressions use the stated elastic, equal-bolt in-plane model. Out-of-plane tension and prying require another model.
Check and takeaway. Do not add force magnitudes before resolving directions. Two perpendicular forces of 3 and 4 kN give 5 kN, not 7 kN.
Change the ruler, keep the quantity
A section table uses centimetres, but the strength calculation uses millimetres. The numbers must describe the same section.
Prediction, then explanation. Would every property increase by ten? No. The exponent determines how many factors of ten are needed.
First identify the physical quantity. Next convert each length factor. Keep force and length conversions separate when converting a moment.
Here n is the length exponent: 2 for area, 3 for section modulus and 4 for second moment of area.
Scope. Changing units changes neither the load nor the section. A conversion factor cannot repair a formula for the wrong physical quantity.
Check and takeaway. Illustration: . The fourth power belongs to the unit, not the number 2.
Apply the reasoning to this section’s data and conditions
Combine direct vertical force per unit length with the torsional line force caused byPe.
Torsion acts tangentially; at the most heavily loaded corner one vertical component adds to direct shear and the horizontal component combines by Pythagoras.
Use line inertias in , not plate inertias in .
1. Centroid, effective line length and corner coordinates
Use the same mechanism: Treat a weld group as lines. Increasing eccentricity increases the torsional contribution. The governing corner depends on vector addition, not distance alone.
Apply the reasoning to this section’s data and conditions
The course rectangular-group model uses the continuous perimeter as its effective line.
Do not subtract separately at each corner of a continuous closed weld.
If fabrication instead provides four separate terminated runs, their actual effective lengths and centroid/inertias require a new model.
Mechanism detailsA weld group is a set of lines
The complete mechanism is explained below.
Read each stage together with its stated conditions; playback and interaction are not required.
- The centre is empty: resistance comes from the weld lines, not a solid plate filling the group.
Use line lengths for centroid weighting.
Line second moments have units .
Add the parallel-axis terms.
Direct force per length is .
The eccentric moment adds tangential flow proportional to distance from the centroid.
- Combine signed components at every candidate corner, then compare the maximum with throat resistance per length.
2. Ultimate load and eccentric moment
Keep load categories separate
A floor carries permanent material and changing occupancy loads. Find the design load for the stated check.
Prediction, then explanation. Increasing imposed load changes its own term. It does not change the dead-load factor or the steel stiffness.
First convert mass to weight where required. Next collect G and Q in compatible units. Apply the combination specified by the course problem.
G is characteristic dead load; Q is characteristic imposed load. Wu is the design load for this course gravity combination.
Scope. This combination is not universal. Use the specified service load for deflection and the stated factors for other standards or cases.
Check and takeaway. Illustration: G = 10 kN and Q = 5 kN give 22 kN. Factoring their sum by one guessed factor loses the distinction.
Use the same mechanism: Treat a weld group as lines. Increasing eccentricity increases the torsional contribution. The governing corner depends on vector addition, not distance alone.
Apply the reasoning to this section’s data and conditions
The eccentricity is already measured from the centroid.
Adding would double-count a geometric offset that is not present in this drawing.
Mechanism detailsFrom characteristic to design load
The complete mechanism is explained below.
Read each stage together with its stated conditions; playback and interaction are not required.
G is permanent load; Q is imposed load.
A surface load and a line load also have different units.
This illustration uses the course gravity case .
Other combinations in the original text retain their own factors.
- For illustrative , the separate load contributions show what changes when Q increases.
Do not carry this ULS total automatically into deflection.
Follow the stated SLS load case.
3. Derive the line polar inertia
Use the same mechanism: Treat a weld group as lines. Increasing eccentricity increases the torsional contribution. The governing corner depends on vector addition, not distance alone.
Apply the reasoning to this section’s data and conditions
Physical interpretation: Only the weld lines resist as weld
Imagine a wire rectangle: its empty middle is not more wire.
Sketch, not to scale; use the original dimensions.
- Count only the weld runs actually shown.
- Use their total length and line second moments.
- Combine direct and torsional forces at the critical location.
Remember: Line second moments have units ; plate-area moments use .
About the horizontal centroid axis, the two vertical runs contribute , and the two horizontal runs at contribute .
SwapB/ for the other axis.
The unit check is essential: ()×distance()/() gives , which can be combined withP/L.
Mechanism detailsA weld group is a set of lines
The complete mechanism is explained below.
Read each stage together with its stated conditions; playback and interaction are not required.
- The centre is empty: resistance comes from the weld lines, not a solid plate filling the group.
Use line lengths for centroid weighting.
Line second moments have units .
Add the parallel-axis terms.
Direct force per length is .
The eccentric moment adds tangential flow proportional to distance from the centroid.
- Combine signed components at every candidate corner, then compare the maximum with throat resistance per length.
4. Corner resultant and required fillet leg
Use the same mechanism: Treat a weld group as lines. Increasing eccentricity increases the torsional contribution. The governing corner depends on vector addition, not distance alone.
Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.
Apply the reasoning to this section’s data and conditions
Physical interpretation: Add arrows before taking the magnitude
Walking east and walking north do not point in the same direction.
Sketch, not to scale; use the original dimensions.
- Choose signed horizontal and vertical directions.
- Add contributions along each direction separately.
- For perpendicular components, use the right-triangle resultant.
Remember: Check the corner where direct and torsional components reinforce each other.
For a equal-leg fillet the throat is .
The smallest side length greatly exceeds the minimum effective-run scale.
The continuous group model remains the assumed geometry.
Mechanism detailsA weld group is a set of lines
The complete mechanism is explained below.
Read each stage together with its stated conditions; playback and interaction are not required.
- The centre is empty: resistance comes from the weld lines, not a solid plate filling the group.
Use line lengths for centroid weighting.
Line second moments have units .
Add the parallel-axis terms.
Direct force per length is .
The eccentric moment adds tangential flow proportional to distance from the centroid.
- Combine signed components at every candidate corner, then compare the maximum with throat resistance per length.
Result and concise exam wording
Use the same mechanism: Treat a weld group as lines. Increasing eccentricity increases the torsional contribution. The governing corner depends on vector addition, not distance alone.
Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.
Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.
Apply the reasoning to this section’s data and conditions
One plate: , .
Four-sided weld group: , .
Governing corner , , resultant .
S355/Class 42: , giving ; passes strength.
Minimum/maximum sizes and connected-part checks still require the unspecified plate/flange thickness.
Misconceptions and checks
Use the same mechanism: Treat a weld group as lines. Increasing eccentricity increases the torsional contribution. The governing corner depends on vector addition, not distance alone.
Apply the reasoning to this section’s data and conditions
- Do not halve a load explicitly carried by one side plate.
- Do not add half the weld width to .
- Do not add perpendicular force components arithmetically.
- Do not use a plane-area polar inertia for a line-weld group.
How the method transfers to a new variant
Use the same mechanism: Treat a weld group as lines. Increasing eccentricity increases the torsional contribution. The governing corner depends on vector addition, not distance alone.
Use the same mechanism: Add force components at each bolt. At fixed force, increasing eccentricity increases the moment component. Its direction differs between bolts.
Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.
Apply the reasoning to this section’s data and conditions
- Read whether load is on one or two plates.
- Locate the weld centroid and actual eccentricity.
- Calculate line length and both centroidal line inertias.
- Resolve torsion and direct force at the governing corner.
- Convert the resultant to throat/leg and then check minimum/maximum detailing with actual member thicknesses.
Prediction with explained answer
Use the same mechanism: Treat a weld group as lines. Increasing eccentricity increases the torsional contribution. The governing corner depends on vector addition, not distance alone.
Apply the reasoning to this section’s data and conditions
Prediction and explained answer.
Invented variant: keepP516 kN but increase eccentricity to .
Is the strength trial still enough?
Answer and reasoning
M258,000 kNmm.
Vertical total=; horizontal=
Resultant exceeds , so narrowly fails strength.
Recompute the exact required leg and choose a larger permitted size; missing detailing inputs still remain.
Mechanism detailsA weld group is a set of lines
The complete mechanism is explained below.
Read each stage together with its stated conditions; playback and interaction are not required.
- The centre is empty: resistance comes from the weld lines, not a solid plate filling the group.
Use line lengths for centroid weighting.
Line second moments have units .
Add the parallel-axis terms.
Direct force per length is .
The eccentric moment adds tangential flow proportional to distance from the centroid.
- Combine signed components at every candidate corner, then compare the maximum with throat resistance per length.