Assignment 1 Q2: a bolted splice
Check bolt shear, bolt bearing, plate bearing and plate tension for the source S355 splice: main plate, two covers, Grade 8.8 M30 bolts in holes, ultimate tension .
Original source: Assignment/AY2627s 1-CON4334-Assignment 1.pdf — p. 2.
A given value comes from the question or diagram.
A lookup value comes from the named table.
A calculated value follows from the working.
Each assumption is stated where the calculation needs it.
Known information, diagram labels and unknowns
Test every possible fracture cut
Find the remaining steel area across a candidate tension-failure path.
Prediction, then explanation. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.
Subtract the hole widths crossed by the path, then multiply by thickness. Compare all plausible paths using the applicable course rule.
An is net area in mm²; b is plate width; d₀ is hole diameter; t is thickness, all in mm. n counts holes on this straight path.
Scope. This expression is for a straight cut. Effective area can require further shear-lag rules. Gross, net and effective areas must remain distinct.
Check and takeaway. Use the hole diameter, not the bolt diameter, when removing missing steel. The plate contains a hole, not solid steel around the bolt shank.
A table value has conditions
Find a design property without mixing a row, column or standard from a different case.
Prediction, then explanation. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.
Match the complete section designation. Read the relevant axis and unit. For strength tables, select material, thickness and curve before interpolating.
Given values come from the question. Lookup values come from a named table. Assumed values require an explicit condition.
Scope. A missing row or omitted restraint cannot be recovered from a schematic’s scale. Keep the result conditional when required data are absent.
Check and takeaway. Record the table, row, column and unit beside the substitution. That makes a later check possible.
Apply the reasoning to this section’s data and conditions
| Value | Origin/type |
|---|---|
| Tension | Given ultimate . Do not multiply by or . Each half-splice transfers this full force. |
| Fasteners | Given M30, Grade 8.8 and hole diameter . Ch 2 table: , , , . |
| Plates | Given S355; , . Main plate , giving ; cover plate , giving . |
| End distance | Cover end is explicitly dimensioned. For a numerical main-plate end check assume the butt lies centrally within the gap, e_m=. This split is a stated symmetry assumption, not a measured drawing length. |
| Distribution | Six bolts per half; main force/bolt . Each of two covers takes . |
Why this method applies
Count cuts through each loaded bolt
Find how many shear planes transfer the force through one side of the connection.
Prediction, then explanation. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.
Select the area at the actual shear plane. Multiply by bolt shear strength. Count only the bolts and planes in the same transfer stage.
ps is bolt shear strength in N/mm²; As is the appropriate area in mm². nb counts bolts; ns counts equally loaded shear planes.
Scope. Use the thread area when threads cross the plane as required. Check bearing, plate failure and detailing separately.
Check and takeaway. Both halves of a butt splice carry the full transmitted force in sequence. Counting both halves together would double the apparent resistance.
Use the same mechanism: Test every possible fracture cut. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.
Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.
Apply the reasoning to this section’s data and conditions
Cut the joint at one half and follow force from the main plate through six double-shear bolts into the two covers.
The other half performs the same transfer in reverse; twelve bolts are not one parallel group carrying .
Check each material layer’s actual force and thickness, then the two-hole net section.
(i) Bolt shear capacity
Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.
Apply the reasoning to this section’s data and conditions
Physical interpretation: Count where the bolt can be sheared
The plate interfaces are the places trying to cut across the bolt.
Sketch, not to scale; use the original dimensions.
- Count actual loaded shear planes, not merely visible plates.
- Choose shank or threaded area for the plane concerned.
- Compare group resistance with the force that group transfers.
Remember: Bolts on opposite sides of a splice do not all act in parallel.
Using the threaded stress area is the conservative course model when thread location is not specified.
Do not use the hole area as the bolt shear area.
Mechanism detailsCount the bolt shear planes
The complete mechanism is explained below.
Read each stage together with its stated conditions; playback and interaction are not required.
- Load must cross an interface between the connected plates.
- A lap joint gives one shear plane through a bolt.
A symmetric double-cover joint may provide two shear planes.
Count load-transfer interfaces, not just visible plates.
Use the source’s area and shear strength.
Then check bearing, plate resistance and detailing separately.
(ii) Bolt bearing against all connected layers
Follow contact pressure into the plate
The bolt may survive shear while the connected plate deforms or tears near the hole.
Prediction, then explanation. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.
Calculate every bound required by the supplied rule. The smallest applicable bound limits the connection at that layer.
pbs is the applicable bearing strength in N/mm²; d is nominal bolt diameter in mm; t is plate thickness in mm.
Scope. This diameter term alone is not the complete check. End-distance and clear-ligament limits, bolt bearing and each connected layer also matter.
Check and takeaway. Two covers and one main plate do not necessarily have the same thickness or strength. Compare the actual force share in each layer.
Apply the reasoning to this section’s data and conditions
Bolt bearing uses nominal bolt diameter and projected contact thickness.
The bolt’s two cover contacts share the load.
The thinner effective thickness is .
The is a bolt-material bearing limit.
It is not the resistance of the weaker S355 plate material, which needs the next check.
Mechanism detailsBearing and the remaining ligament
The complete mechanism is explained below.
Read each stage together with its stated conditions; playback and interaction are not required.
- Force transfers through contact between bolt and connected plate.
The plate around the hole carries bearing stress.
Bolt bearing and plate bearing are separate checks.
A short ligament can tear out towards the end.
The direction of force determines the relevant edge.
- Evaluate every specified bearing and ligament bound for each layer and retain the smallest applicable resistance.
(iii) Plate bearing and ligament limits
Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.
Apply the reasoning to this section’s data and conditions
Physical interpretation: The bolt can crush or tear the plate
A strong bolt can still push through a weak hole edge.
Sketch, not to scale; use the original dimensions.
- Check the bolt and each connected plate’s bearing bounds.
- Use nominal bolt diameter for bearing; hole size for removed material.
- The smallest applicable resistance controls.
Remember: A short end distance may govern even when bolt shear passes.
Use Ch 2 pp.9–10: the ordinary, non-countersunk hole model uses ; nominal , longitudinal spacing , hole diameter , hence clear ligament between holes .
For each plate, take the minimum of the three course bearing bounds.
| Bound per bolt | Main (e_m 55 assumed) | One cover (e 55 given) |
|---|---|---|
| ceiling | ||
| Minimum |
If the butt is not centered, retain the actual main end distancee_m.
For the end-distance bearing bound alone:
This is only the strength-derived minimum; detailing may require substantially more.
For a standard M30 bolt, edge preparation determines the minimum end/edge distance.
A sheared or hand flame-cut edge requires .
A rolled or machine gas-cut edge requires .
The known transverse therefore satisfies the latter but not the former.
The longitudinal spacing is ; transverse spacing ; maximum spacing .
Therefore, the transverse spacing is exactly at the maximum.
Confirm the edge preparation and the main-plate end distances on both sides of the butt joint before declaring the detail unconditionally satisfactory.
Mechanism detailsBearing and the remaining ligament
The complete mechanism is explained below.
Read each stage together with its stated conditions; playback and interaction are not required.
- Force transfers through contact between bolt and connected plate.
The plate around the hole carries bearing stress.
Bolt bearing and plate bearing are separate checks.
A short ligament can tear out towards the end.
The direction of force determines the relevant edge.
- Evaluate every specified bearing and ligament bound for each layer and retain the smallest applicable resistance.
(iv) Main and cover tensile capacities
Use the same mechanism: Test every possible fracture cut. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.
Apply the reasoning to this section’s data and conditions
Physical interpretation: Why holes reduce tension resistance
The pull must squeeze through the steel left beside the holes.
Sketch, not to scale; use the original dimensions.
- Choose a possible fracture line across the member.
- Subtract the holes crossed by that line using hole diameter.
- Apply the course effective-area rule and its gross-area limit.
Remember: Do not subtract every hole anywhere in the connection.
A transverse net-section cut through an aligned bolt column crosses two holes, not all six holes along a half-splice.
Course effective areaAe=min(Ag,KeAn), with Ke 1.1 for the stated S355 course model.
The cover pair’s tension resistance gives the smallest of the requested numerical group capacities.
Strength passes under the stated end-bearing assumption, with only capacity above demand in cover tension.
The transverse edge preparation caveat remains a separate detailing issue.
Mechanism detailsSubtract holes on the failure path
The complete mechanism is explained below.
Read each stage together with its stated conditions; playback and interaction are not required.
- Gross area counts the complete plate width and thickness.
- The highlighted transverse path passes through the bolt holes.
For the straight illustrative path, .
Staggered paths require their specified correction.
Net area is not always effective area.
Include the course’s strength ratio or shear-lag rule when applicable.
Result and concise exam wording
Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.
Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.
Use the same mechanism: Test every possible fracture cut. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.
Apply the reasoning to this section’s data and conditions
Per half: sixM30 in double shear.
Shear ; bolt bearing ; plate bearing main and cover pair (centered-butt e_m 55 assumed).
Tensile main and cover pair .
All exceed .
Cover tension controls. side edges require an edge category permitting ; they fail the sheared-edge minimum.
Confirm the main end-distance split before final approval.
Misconceptions and checks
Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.
Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.
Apply the reasoning to this section’s data and conditions
- Do not divide by twelve bolts for a half-splice check.
- Do not add the full thickness for the controlling bolt bearing.
- Use for hole deductions and for projected bearing.
- Do not use in the main tensile calculation.
How the method transfers to a new variant
Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.
Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.
Use the same mechanism: Test every possible fracture cut. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.
Apply the reasoning to this section’s data and conditions
- Draw the half-splice force path.
- Count shear planes and forces per plate.
- Check bolt shear and bearing.
- Evaluate every plate-bearing bound and detailing condition.
- Cut the correct net section, cap effective area at gross, and check main and covers separately.
Prediction with explained answer
Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.
Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.
Use the same mechanism: Test every possible fracture cut. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.
Apply the reasoning to this section’s data and conditions
Prediction and explained answer.
Invented variant: ultimate tension increases to with no geometry change.
Which demonstrated requested check first fails?
Answer and reasoning
The cover-pair tensile resistance remains , below .
The main tensile, shear and the stated bearing capacities still exceed , but any failed required check makes the detail inadequate.
Cover tension cannot be rescued by surplus bolt shear resistance.