2022–2024 · Exam-focused route
2023 FT/PTD — answer navigator
This is the paper dated 5 January 2023 (AY 2022/23), filename 22ENGTY006. It is a different paper from the 2023 PTE paper 22ENGTY033 already on the site.
Original source: 22ENGTY006.pdf · physical page 1
Use the supplied exam format
Two hours. Section A is compulsory: 40 marks. Choose any TWO of the three Section B questions, 30 marks each. Answer 100 marks out of 130 offered. These are printed allocations, not an invented marking scheme.
Suggested timing: 5 minutes to read and choose, 42 minutes for Section A, 32 minutes per chosen Section B question, 9 minutes to check. Choose using the entire question, including the smaller subparts and missing assumptions.
Introduction / short theory
| Printed question / marks | Full solution | Status |
|---|---|---|
| AQ1(b) / 4 | AQ1(b) — two fire-protection methods | Checked within requested strength scope |
Connections
| Printed question / marks | Full solution | Status |
|---|---|---|
| BQ2(a)(i) / 2 | BQ2(a)(i) — double-shear bolts | Checked within requested strength scope |
| BQ2(a)(ii) / 2 | BQ2(a)(ii) — bolt bearing | Checked within requested strength scope |
| BQ2(a)(iii) / 6 | BQ2(a)(iii) — angle bearing | Checked within requested strength scope |
| BQ2(a)(iv) / 7 | BQ2(a)(iv) — double-angle tension | Checked within requested strength scope |
| BQ2(b) / 13 | BQ2(b) — check the web and flange welds | Conditional — final adequacy incomplete |
Beams, floor actions and LTB
| Printed question / marks | Full solution | Status |
|---|---|---|
| AQ1(a)(i) / 4 | AQ1(a)(i) — slab design intensity | Checked within requested strength scope |
| AQ1(a)(ii) / 8 | AQ1(a)(ii) — actions on both beams | Checked within requested strength scope |
| AQ1(a)(iii) / 4 | AQ1(a)(iii) — classification | Checked within requested strength scope |
| AQ1(a)(iv) / 10 | AQ1(a)(iv) — B1 adequacy | Checked within requested strength scope |
| AQ1(a)(v) / 10 | AQ1(a)(v) — B3 adequacy | Checked within requested strength scope |
| BQ4(a) / 3 | BQ4(a) — support reactions | Checked within requested strength scope |
| BQ4(b) / 4 | BQ4(b) — annotated SFD and BMD | Checked within requested strength scope |
| BQ4(c) / 13 | BQ4(c) — segment BC | Conditional — final adequacy incomplete |
| BQ4(d) / 10 | BQ4(d) — cantilever AB, conditional branches | Conditional — final adequacy incomplete |
Columns
| Printed question / marks | Full solution | Status |
|---|---|---|
| BQ3(a) / 3 | BQ3(a) — axial force and moments | Conditional — final adequacy incomplete |
| BQ3(b) / 8 | BQ3(b) — cross-section capacity | Conditional — final adequacy incomplete |
| BQ3(c) / 19 | BQ3(c) — member buckling | Conditional — final adequacy incomplete |
All 18 printed subquestions have a worked teaching answer. Conditional rows include the calculations and assumptions.