Steelwork · Exam learning

2022–2024 · Exam-focused route

2023 FT/PTD — answer navigator

All answers shown

This is the paper dated 5 January 2023 (AY 2022/23), filename 22ENGTY006.

It is a different paper from the 2023 PTE paper 22ENGTY033 already on the site.

Original source: 22ENGTY006.pdf · physical page 1

Use the supplied exam format

Ask two separate design questions

Decide whether the check concerns failure or unacceptable behaviour during use.

The strength branch compares demand with resistance. The service branch compares displacement with its specified limit.
The strength branch compares demand with resistance. The service branch compares displacement with its specified limit.

Prediction, then explanation. A larger section may improve both results, but a pass on one branch does not prove a pass on the other.

ULS addresses relevant strength and stability failure modes. SLS addresses specified service conditions such as deflection.

demand≤resistance,δ≤δlimit\text{demand}\le\text{resistance},\qquad\delta\le\delta_{limit}

δ is the calculated displacement; δlimit is the permitted displacement. Both must use the same length unit.

Scope. Use each check’s own load combination and limit. A strength load factor does not change the physical stiffness.

Check and takeaway. Write separate conclusions for strength, stability and serviceability where requested. A single unexplained “safe” hides those distinctions.

Apply the reasoning to this section’s data and conditions

Two hours.

Section A is compulsory: 40 marks.

Choose any TWO of the three Section B questions, 30 marks each.

Answer 100 marks out of 130 offered.

These are printed allocations, not an invented marking scheme.

Suggested timing: 5 minutes to read and choose, 42 minutes for Section A.

Allow 32 minutes per chosen Section B question, 9 minutes to check.

Choose using the entire question, including the smaller subparts and missing assumptions.

Introduction / short theory

Delay heat reaching the steel

Identify how the protection surrounds a steel section. Then explain its purpose in a fire.

SolidHollowProfileSteel outline and protection boundary are separate.
Solid casing fills around the section. Hollow casing encloses an air space. Profile protection follows the section outline.

Prediction, then explanation. An insulating layer can slow heating. It does not mean the steel remains at room temperature indefinitely.

Heat changes steel behaviour. Protection delays that change by restricting heat transfer. Show the steel and protection boundaries separately.

The labelled boundaries describe geometry. They do not specify a tested fire-resistance rating.

Scope. Required thickness depends on the system, member and required rating. Do not infer thickness or minutes from a schematic.

Check and takeaway. For a sketch answer, distinguish all three shapes and state that protection delays steel heating.

Apply the reasoning to this section’s data and conditions

Printed question / marksFull solutionStatus
AQ1(b) / 4AQ1(b) — two fire-protection methodsChecked within requested strength scope

Connections

Count cuts through each loaded bolt

Find how many shear planes transfer the force through one side of the connection.

The middle plate moves against two cover plates. The two interfaces cut each bolt at two planes.
The middle plate moves against two cover plates. The two interfaces cut each bolt at two planes.

Prediction, then explanation. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Select the area at the actual shear plane. Multiply by bolt shear strength. Count only the bolts and planes in the same transfer stage.

Ps=psAs,Pgroup=nbnsPsP_s=p_sA_s,\qquad P_{group}=n_b n_s P_s

ps is bolt shear strength in N/mm²; As is the appropriate area in mm². nb counts bolts; ns counts equally loaded shear planes.

Scope. Use the thread area when threads cross the plane as required. Check bearing, plate failure and detailing separately.

Check and takeaway. Both halves of a butt splice carry the full transmitted force in sequence. Counting both halves together would double the apparent resistance.

Follow contact pressure into the plate

The bolt may survive shear while the connected plate deforms or tears near the hole.

The labels distinguish bolt diameter d from hole diameter d₀. The arrow at the hole edge shows the bearing contact action.
The labels distinguish bolt diameter d from hole diameter d₀. The arrow at the hole edge shows the bearing contact action.

Prediction, then explanation. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.

Calculate every bound required by the supplied rule. The smallest applicable bound limits the connection at that layer.

Pbearing≤pbsdtP_{bearing}\le p_{bs}dt

pbs is the applicable bearing strength in N/mm²; d is nominal bolt diameter in mm; t is plate thickness in mm.

Scope. This diameter term alone is not the complete check. End-distance and clear-ligament limits, bolt bearing and each connected layer also matter.

Check and takeaway. Two covers and one main plate do not necessarily have the same thickness or strength. Compare the actual force share in each layer.

One connected leg does not load both legs equally

An angle carries tension through only one leg. Determine how much section area the design rule permits.

The force enters the connected leg first. The outstanding leg receives force through the angle corner and adjoining material.
The force enters the connected leg first. The outstanding leg receives force through the angle corner and adjoining material.

Prediction, then explanation. Keeping the same gross area does not guarantee the same tension resistance when the connection arrangement changes.

Separate connected and outstanding leg areas. Include the actual holes. Then use the supplied single-angle or double-angle effective-area rule.

Pt=pyAeP_t=p_yA_e

Ae is the effective area from the applicable angle rule in mm². py is the relevant design strength in N/mm².

Scope. Do not assume the whole gross area is effective. Symmetry, connected leg and connection type determine which rule applies.

Check and takeaway. The outstanding leg contributes through load transfer; the rule need not either count all of it or discard all of it.

Apply the reasoning to this section’s data and conditions

Printed question / marksFull solutionStatus
BQ2(a)(i) / 2BQ2(a)(i) — double-shear boltsChecked within requested strength scope
BQ2(a)(ii) / 2BQ2(a)(ii) — bolt bearingChecked within requested strength scope
BQ2(a)(iii) / 6BQ2(a)(iii) — angle bearingChecked within requested strength scope
BQ2(a)(iv) / 7BQ2(a)(iv) — double-angle tensionChecked within requested strength scope
BQ2(b) / 13BQ2(b) — check the web and flange weldsConditional — final adequacy incomplete

Beams, floor actions and LTB

Vertical bending can trigger sideways motion

A beam has enough local bending resistance. Check whether its compression flange can move sideways and twist.

The dashed straight line is the initial reference. The curved flange lines illustrate the labelled sideways movement and twist.
The dashed straight line is the initial reference. The curved flange lines illustrate the labelled sideways movement and twist.

Prediction, then explanation. Adding a valid lateral restraint shortens a stability segment. It need not change the beam’s vertical reaction or moment diagram.

Identify the compressed flange and effective restraints. Calculate the specified slenderness, read buckling strength and compare resistance with the segment demand.

λ=LE/ry,Mb=pbSx  (Class 1/2),mLTMmax≤Mb\lambda=L_E/r_y,\qquad M_b=p_bS_x\;\text{(Class 1/2)},\qquad m_{LT}M_{max}\le M_b

LE and ry use the same length unit. pb uses N/mm²; Sx uses mm³; Mb uses N·mm. mLT is dimensionless.

Scope. Use the specified section class, effective-length branch and loading condition. Load height alone does not prove a destabilizing case.

Check and takeaway. Removing a lateral restraint requires a new segment stability check. The old shorter-segment result cannot establish the longer segment’s adequacy.

Apply the reasoning to this section’s data and conditions

Printed question / marksFull solutionStatus
AQ1(a)(i) / 4AQ1(a)(i) — slab design intensityChecked within requested strength scope
AQ1(a)(ii) / 8AQ1(a)(ii) — actions on both beamsChecked within requested strength scope
AQ1(a)(iii) / 4AQ1(a)(iii) — classificationChecked within requested strength scope
AQ1(a)(iv) / 10AQ1(a)(iv) — B1 adequacyChecked within requested strength scope
AQ1(a)(v) / 10AQ1(a)(v) — B3 adequacyChecked within requested strength scope
BQ4(a) / 3BQ4(a) — support reactionsChecked within requested strength scope
BQ4(b) / 4BQ4(b) — annotated SFD and BMDChecked within requested strength scope
BQ4(c) / 13BQ4(c) — segment BCConditional — final adequacy incomplete
BQ4(d) / 10BQ4(d) — cantilever AB, conditional branchesConditional — final adequacy incomplete

Columns

A strong cross-section can belong to an unstable member

A column carries axial compression and bending. Explain why more than one check is required.

The three boxes name separate checks: Section, Flexural and LTB. The bottom caption explains that passing one does not pass the others.
The three boxes name separate checks: Section, Flexural and LTB. The bottom caption explains that passing one does not pass the others.

Prediction, then explanation. At fixed moments and resistances, increasing compression increases utilisation. A section pass cannot remove the length-dependent instability checks.

Separate cross-section, flexural-buckling and LTB interaction equations. Use each equation’s own denominators and first-order or amplified moments.

AgpyA_g p_y is a section axial resistance. AgpcA_g p_c is a member compression resistance. Elastic pyZp_y Z and prescribed McM_c are different bending denominators.

Scope. Preserve the course barred-moment definitions and Eq. 8.81 convention. Do not substitute plastic moduli into an elastic denominator.

Check and takeaway. Report each requested utilisation and the governing check. The largest properly calculated ratio identifies the closest limit.

Apply the reasoning to this section’s data and conditions

Printed question / marksFull solutionStatus
BQ3(a) / 3BQ3(a) — axial force and momentsConditional — final adequacy incomplete
BQ3(b) / 8BQ3(b) — cross-section capacityConditional — final adequacy incomplete
BQ3(c) / 19BQ3(c) — member bucklingConditional — final adequacy incomplete

All 18 printed subquestions have a worked teaching answer.

Conditional rows include the calculations and assumptions.