STEELWORK / CON4334

Detailed edition — terminology and reading guide

The detailed edition explains the material with short sentences, pictures and step-by-step reasoning. Every prediction comes with its answer. Each lesson keeps the original data, formulas and figures.

Change the ruler, keep the quantity

Here n is the length exponent: 2 for area, 3 for section modulus and 4 for second moment of area.

Changing units changes neither the load nor the section. A conversion factor cannot repair a formula for the wrong physical quantity.

Find the missing factor

P is force in N; p is the applicable design strength in N/mm²; A is area in mm².

The area must match the failure model. Gross area, net area and effective throat area are different quantities.

Move between two known values

x is the required input. The two known pairs are (x₀, y₀) and (x₁, y₁). f has no unit.

Use one table, curve and strength column. This interpolation does not permit extrapolation or inventing an intermediate steel section.

Keep load categories separate

G is characteristic dead load; Q is characteristic imposed load. Wu is the design load for this course gravity combination.

This combination is not universal. Use the specified service load for deflection and the stated factors for other standards or cases.

Follow one strip of floor

q is area load in kN/m²; b is tributary width in m; w is line load in kN/m.

Determine b from slab spanning and supports. Add beam self-weight separately. A secondary-beam reaction is not automatically a UDL.

Balance the isolated beam

P, RA and RB are forces in kN. L is support spacing and a is load position, both in m.

These expressions describe one point load on a simply supported beam. Add other loads through equilibrium; keep their actual positions.

A cut reveals the internal actions

x and L use m; w uses kN/m; V uses kN; M uses kN·m. These lines apply before any point load.

A point load adds a shear jump. A concentrated couple adds a moment jump. Check load points, supports and overhang roots too.

A safe beam can still sag too far

Use w in N/mm, L in mm, E in N/mm² and I in mm⁴. The resulting midspan deflection is in mm.

The formula assumes a prismatic, simply supported, linear-elastic beam with full-span UDL. Use the stated service load and deflection limit.

Separate stiffness, strength and ductility

σ is stress in N/mm²; ε is dimensionless strain; E is Young’s modulus in N/mm².

Use this linear relationship only in its elastic range. Ductility concerns deformation before fracture, not the value of E.

Repeated loading can grow a crack

Δσ is stress range in N/mm². Maximum and minimum stresses must refer to the same location and stress component.

The sketch is a mechanism explanation, not a life prediction. Fatigue design requires the applicable detail category and load history.

Interrupt the corrosion process

No universal coating thickness or life follows from this mechanism sketch.

Weathering steel still needs suitable exposure and detailing. A protection label does not replace inspection or maintenance.

Delay heat reaching the steel

The labelled boundaries describe geometry. They do not specify a tested fire-resistance rating.

Required thickness depends on the system, member and required rating. Do not infer thickness or minutes from a schematic.

Use the property for the physical question

I is second moment of area in mm⁴. y is distance from the chosen axis in mm. A is area in mm². r is radius of gyration in mm.

Z is elastic section modulus; S is plastic section modulus in this course. Neither is interchangeable with I.

Find which plate buckles first

py is the design yield strength in N/mm². ε is a dimensionless scale used in the supplied classification limits.

Pure bending and uniform compression use different web limits. Class 2 allows plastic resistance but not the Class 1 rotation capability.

Compression acts on the displaced shape

P is axial force. Δ and δ are the relevant perpendicular displacements. Consistent force and length units give moment units.

Use the amplification or analysis method stated for the frame. Do not amplify an already amplified moment a second time.

Restraints define the analysis model

Simple, continuous and semi-continuous construction describe joint modelling. Sway classification describes overall frame response.

The schematic does not establish restraint stiffness or a stability threshold. Use the stated data and classification rules.

Keep a local failure from spreading

A load path is a sequence of members and connections that transfers actions to support.

The alternate arrows are an explanation, not proof that the remaining members or connections can carry redistributed actions.

A crack can fail without large yielding

Toughness concerns resistance to fracture. Ductility concerns deformation before fracture. Yield strength is a different property.

The sketch does not predict a critical crack size. Apply the supplied material-selection and detailing requirements.

Ask two separate design questions

δ is the calculated displacement; δlimit is the permitted displacement. Both must use the same length unit.

Use each check’s own load combination and limit. A strength load factor does not change the physical stiffness.

A table value has conditions

Given values come from the question. Lookup values come from a named table. Assumed values require an explicit condition.

A missing row or omitted restraint cannot be recovered from a schematic’s scale. Keep the result conditional when required data are absent.

A bolt diameter is not a hole diameter

lc is clear ligament between holes; p is centre-to-centre pitch; d₀ is hole diameter. All use mm.

Apply the supplied edge-preparation and minimum/maximum spacing rules. Passing a bearing calculation does not prove the layout passes.

Count cuts through each loaded bolt

ps is bolt shear strength in N/mm²; As is the appropriate area in mm². nb counts bolts; ns counts equally loaded shear planes.

Use the thread area when threads cross the plane as required. Check bearing, plate failure and detailing separately.

Follow contact pressure into the plate

pbs is the applicable bearing strength in N/mm²; d is nominal bolt diameter in mm; t is plate thickness in mm.

This diameter term alone is not the complete check. End-distance and clear-ligament limits, bolt bearing and each connected layer also matter.

Test every possible fracture cut

An is net area in mm²; b is plate width; d₀ is hole diameter; t is thickness, all in mm. n counts holes on this straight path.

This expression is for a straight cut. Effective area can require further shear-lag rules. Gross, net and effective areas must remain distinct.

A block leaves along two types of path

Shear and tension areas use mm². Their strength coefficients refer to different mechanisms and are not interchangeable.

Do not replace the supplied block-shear expression with the simple net-tension formula. Geometry and deductions depend on the actual path.

One connected leg does not load both legs equally

Ae is the effective area from the applicable angle rule in mm². py is the relevant design strength in N/mm².

Do not assume the whole gross area is effective. Symmetry, connected leg and connection type determine which rule applies.

Add force components at each bolt

e, xi and yi use mm; J uses mm². With M in kN·mm, each moment-force component is in kN.

These expressions use the stated elastic, equal-bolt in-plane model. Out-of-plane tension and prying require another model.

An eccentric bracket pulls bolts differently

M is moment in kN·mm. yi is distance from the stated pivot in mm. Ft,i is tension in kN.

Apply only to the stated active bolt set and pivot model. Flexible plates can create prying; use the supplied assumptions and resistance definitions.

Two simultaneous actions use one component

This is the course bolt interaction rule. Fs and Ft are bolt demands; Ps and Pnom are their specified resistance denominators.

The 1.4 limit and nominal tension denominator do not apply to column equations. Their limits and moment definitions are separate.

A long joint may not share load equally

Joint length is measured along load transfer. Grip is the total clamped thickness relevant to the bolt detail.

Use only reductions required by the stated code model. The sketch does not determine a reduction coefficient.

The weld resists through its throat

s and a are leg and throat in mm. pw is weld strength in N/mm². qcap is resistance in kN/mm.

Use effective length, the correct steel/electrode strength and permitted leg limits. Full-penetration butt welds use a different model.

Penetration changes the resisting section

Penetration describes how deeply the joint is fused. A fillet leg is a different dimension.

Do not apply the fillet factor 0.7 to a butt weld merely because both are welds. Inspection and workmanship remain part of the specified requirements.

Follow tension through the intact plate

b and t use mm; A uses mm²; py uses N/mm². The product gives resistance in N.

This simple expression does not include holes, shear lag, eccentric bending or other required connection checks.

Treat a weld group as lines

J is line polar inertia in mm³. x and y use mm. With M in kN·mm, q is line force in kN/mm.

A solid rectangle has area inertia in mm⁴ and is not this weld-line model. Missing weld sides change the centroid and integrals.

Unequal lever arms require unequal forces

P, F₁ and F₂ are forces. z₁ and z₂ are perpendicular distances from the load line. Use consistent length units.

Equal force shares apply only to the symmetric case. Physical terminated weld length also needs the supplied end deductions.

A force couple carries moment

M is moment in kN·mm; z is the specified force-line separation in mm; F is force in kN.

Use the lever arm defined by the source model. Do not silently replace it with overall section depth or another geometric distance.

The web carries the shear check

D is overall depth; t is web thickness, in mm. Av uses mm². py uses N/mm², giving Vc in N.

Apply this area definition to the stated rolled section. Check web slenderness separately. The factor 0.6 is the low-shear threshold, not this resistance coefficient.

Internal tension and compression resist moment

py uses N/mm². S is plastic modulus and Z is elastic modulus, both in mm³. Mc then uses N·mm.

This is section resistance, not whole-member LTB resistance. High shear and Class 4 require their appropriate treatment.

Shear and bending share the web

V is shear at the checked section; Vc is its shear resistance. Both use the same force unit.

Above the threshold, use the supplied reduction expression. The threshold itself is not a substitute resistance formula.

A concentrated force spreads into the web

b₁ is stiff-bearing length in mm. Web thickness and applicable design strength enter the prescribed local resistance equation.

End and interior cases can differ. A lateral-restraint symbol does not provide a bearing length or a load-introduction detail.

The loaded web can act as a short strut

Local web effective length is not the beam span or the LTB segment length. Use the symbol definition in the selected local formula.

The short-strut picture explains a mechanism; it is not a derivation of every coefficient in the supplied web rule.

Vertical bending can trigger sideways motion

LE and ry use the same length unit. pb uses N/mm²; Sx uses mm³; Mb uses N·mm. mLT is dimensionless.

Use the specified section class, effective-length branch and loading condition. Load height alone does not prove a destabilizing case.

Moment shape matters within one segment

mLT is an LTB factor. mx and my belong to the specified flexural checks. They are not interchangeable.

Some rules use magnitudes; others require signed ordinates. A factor does not reduce the actual moment used in a local section check.

Check buckling about both axes

Effective lengths and radii use mm. pc is compressive strength in N/mm²; Ag is gross area in mm²; Pc is in N.

Do not select the governing axis using radius alone. Effective length and buckling curve can differ. A combined column also needs interaction checks.

A strong cross-section can belong to an unstable member

AgpyA_g p_y is a section axial resistance. AgpcA_g p_c is a member compression resistance. Elastic pyZp_y Z and prescribed McM_c are different bending denominators.

Preserve the course barred-moment definitions and Eq. 8.81 convention. Do not substitute plastic moduli into an elastic denominator.

An eccentric beam reaction bends the column

R is reaction; e is perpendicular eccentricity. K denotes the stiffness measure prescribed for moment sharing.

Equal sharing requires equal stated stiffness. Use actual storey length where the special simple-construction LTB rule requires it.

Make the next decision from the known conditions

A conditional answer states the exact condition required for its conclusion. It does not fill missing data with a guess.

A repeated result is not an independent verification. Use equilibrium, dimensions, a reverse substitution or an appropriate limiting case.