960 kN test question: four checks (Four Checks)
Task: Complete the four test calculations using the taught method; the lecturer gives no complete solution in class.
Go straight to Step 1 ↓Design flow for this type of question: Ordinary bolted connection →

The question in short: Two 24 mm main plates are joined by two 10 mm cover plates with 6 M27 bolts in each half of the joint. The ultimate pull is 960 kN. Complete four checks: bolt shear, bolt bearing, plate bearing, and tension in the plates.
What differs from the previous example of this type: Same type as the earlier double-cover splice, but here the two covers together are thinner than the main plate. So bearing and tension in the covers must also be checked item by item.
| Given | Value and Unit |
|---|---|
| Problem | Ultimate tension 960 kN; main plate 24 mm; two 10 mm covers; S355 |
| Bolts and holes | Grade 8.8 M27, ; 30 mm holes; six bolts per half-joint |
| Geometry | Plate width 35 + 120 + 35 = 190 mm; pitch along the force 90 mm; end distance 45 mm; two holes across |
| Course table values | ; , , , , ; |
Yellow: values given in the question. The same values are marked where they are substituted in the steps below.
Orange box: values read directly from the Data File, the same values boxed orange in the lookup screenshots. A value interpolated between two table rows is a calculation, so it has no box.
Solution Route: Half-joint demand→double-shear bolts→bolt bearing →main/cover bearing→net-section tension in both plate types.
This browser cannot show the 3D model.
The same path as the 750 kN splice: main plate → bolts → two cover plates → bolts → main plate. Here the two covers total 20 mm, thinner than the 24 mm main plate, so the cover checks come closer to the limit.
- Ultimate tension960 kN; six bolts per half, 160 kN each
- Main plate in tension (net section)Demand 960 kNCapacity 1184.04 kNUtilisation 0.81
- Bearing on the main plateDemand 160 kNCapacity 297 kNper boltUtilisation 0.54
- Bolts in double shearDemand 160 kNCapacity 344.25 kNper boltUtilisation 0.46
- Bearing on each cover plateDemand 80 kNCapacity 123.75 kNper cover, per boltUtilisation 0.65
- Each cover plate in tension (net section)Demand 480 kNCapacity 507.65 kNper coverUtilisation 0.95 · closest to the limit
- Step 1 · Demand in each half-joint
Why this step: The pull goes from one main plate through its bolts into the covers, then through the bolts of the other half into the other main plate. This step finds the force each bolt must pass on.
Each half transfers the full 960 kN. The halves act in series; do not divide by twelve across both.
New symbols in this step- , , : Total force, shear per bolt and tension per bolt; kN
- , : Bolt spacing along the force, mm; number of bolts
- Step 2 · Double shear
Why this step: This guards against the bolt being cut at the two faces between the main plate and the covers. With capacity above the demand per bolt, the bolt will not shear off.
M27 effective area comes from the course bolt table; there are two shear planes.
New symbols in this step- , , , : Shear, bolt bearing, plate bearing and plate tension resistances; kN
- , , , : Corresponding course design strengths; N/mm²
Units: in N/mm² times in mm² gives N; dividing by 1000 gives kN.
Data file lookup · Data Page 4 · Bolt tables
The M27 row gives tensile stress area ; the Grade 8.8 row gives and .Yellow: given parameter, row or columnOrange: value read from the table, boxed orange in the text too - Step 3 · Bolt bearing
Why this step: The same bolt presses on the main plate one way and on the two covers the other way. The side with less contact thickness is where the bolt is more easily crushed.
Compare 24 mm main-plate thickness with combined covers of 20 mm; the latter governs.
New symbols in this step- , , , : Bolt diameter, hole diameter, end distance along force and clear hole spacing; mm
Units: and the plate thickness are in mm and is in N/mm², so each product is in N; both lines divide by 1000 to give kN.
- Step 4 · Clear distance between holes
Why this step: Only after deducting the hole do we get the real steel between two holes. This length goes into the bearing calculations for both the main plate and the covers.
Subtract 30 mm hole diameter from 90 mm longitudinal pitch. Standard holes use .
- Step 5 · Four main-plate bearing candidates
Why this step: This guards against the main plate being crushed at the hole or the steel behind the hole being pushed out. The smallest of the four values is the bearing capacity of the main plate.
Substitute 24 mm main-plate thickness and 45 mm end distance in each expression; convert N to kN.
New symbols in this step- , : Hole-type and effective-area factors; dimensionless
Where the numbers come from: from Step 4.
Units: , , and are in mm; , and are in N/mm². Each product is in N, and dividing by 1000 gives kN.
Data file lookup · Data Page 4 · Bearing of connected part
Standard holes give . For S355 plate the bearing strength is and ; for the bolt .Yellow: given parameter, row or columnOrange: value read from the table, boxed orange in the text too Load path · Four limits on plate bearingThe bolt presses on the hole wall, and the plate can fail in four ways: the hole wall crushes, the bolt tears out through the plate end, the plate tears between two holes, and there is a cap set by the bolt strength. The smallest of the four values is used (red frame). - Step 6 · Bearing per cover plate
Why this step: Each cover is much thinner than the main plate, so its hole wall has less contact area and crushes more easily. The demand must also be the force on one cover.
Each 10 mm cover carries 80 kN per bolt. The four candidates are 148.5, 123.75, 459 and 432.
Where the numbers come from: from Step 4; from Step 1.
Units: The lengths and are in mm; , and are in N/mm². Each product is in N; dividing by 1000 gives kN, ready to compare with the demand on one cover.
- Step 7 · Equivalent combined-cover comparison
Why this step: Capacity and demand must cover the same thing: one cover against the share of one cover, or both covers against the whole bolt force. Either way gives the same conclusion.
If using combined resistance 247.5, use the total per-bolt demand 160 as well.
Where the numbers come from: from Step 6.
- Step 8 · Main-plate net section
Why this step: This guards against the main plate being pulled apart along a row of holes. The steel removed is set by the hole size, because the hole is larger than the bolt.
The straight section crosses two holes: deduct 2×30, not 2×27.
- Step 9 · Main-plate effective area and strength
Why this step: This turns the area after deducting holes into the area used for tension capacity. Multiplying it by the design strength in the next step gives the tension capacity of the main plate.
Apply to net area without exceeding gross area . For 24 mm, the course uses .
New symbols in this step- , , , : Bolt effective shear area and gross/net/effective plate areas; mm²
Where the numbers come from: from Step 8.
Data file lookup · Data Page 2 · Tension members
for S355.Yellow: given parameter, row or columnOrange: value read from the table, boxed orange in the text too Data file lookup · Data Page 1 · Design strength
Cover plate 10 mm thick: the row, S355 column gives ; main plate 24 mm thick: the row, S355 column gives . How the grade and thickness choose this row →Yellow: given parameter, row or columnOrange: value read from the table, boxed orange in the text too - Step 10 · Main-plate tension resistance
Why this step: The main plate alone carries the whole pull, so its capacity is compared with the total pull, not with the force per bolt.
Compare with the full connection force of 960 kN.
Where the numbers come from: from Step 9.
Units: is in N/mm² and is in mm², so the product is in N; dividing by 1000 gives kN.
- Step 11 · Tension in both covers
Why this step: In the middle of the joint the pull is carried entirely by the two covers. Together they are thinner than the main plate, so they are more likely to break at the holes.
Each has and . At 10 mm, ; each carries 480 kN.
Units: is in N/mm² and the of one cover is in mm², so the product is in N; dividing by 1000 gives kN.
- Step 12 · Identify the closest margin
Why this step: The item with the highest utilisation reaches its limit first. It shows that if the pull grew, the covers breaking at the holes would be the first failure.
Combined cover tension resistance is 1015.3 kN, closest to 960 among these four checks, with utilisation about 0.946. Other hole-position and complete-connection details still need checking.
With the stated geometry and course table values, all four capacities are adequate. Do not transfer the replayed 750 kN example's thicknesses, holes or 818.2 kN result here.
All the symbols of this example
| Symbols | Meaning and Units |
|---|---|
| , , | Total force, shear per bolt and tension per bolt; kN |
| , , , | Shear, bolt bearing, plate bearing and plate tension resistances; kN |
| , , , | Bolt diameter, hole diameter, end distance along force and clear hole spacing; mm |
| , , , | Bolt effective shear area and gross/net/effective plate areas; mm² |
| , , , | Corresponding course design strengths; N/mm² |
| , | Plate and bolt ultimate tensile strengths; N/mm² |
| , | Hole-type and effective-area factors; dimensionless |
| , | Bolt spacing along the force, mm; number of bolts |
Video positions: 7 November 00:15:00 · 7 November 00:20:00 · 7 November 01:15:00 · 24 October 02:35:00