2022–2024 · Exam-focused route
2022 BQ2 — column with biaxial bending
Complete the axial-force, section and member checks, following this paper’s moment model.
Marks are as printed in the paper; the working is a teaching guide, not an official marking scheme.
Choose the column model first
An eccentric beam reaction bends the column
A simple beam joint delivers a vertical reaction away from the column centre. Find the resulting column moments.
Prediction, then explanation. Equal opposite-face reactions can cancel a joint moment. Their downward forces still add to column compression.
Sum axial forces first. Calculate the signed eccentric moments. Share the net joint moment between upper and lower columns using the stated stiffness model.
R is reaction; e is perpendicular eccentricity. K denotes the stiffness measure prescribed for moment sharing.
Scope. Equal sharing requires equal stated stiffness. Use actual storey length where the special simple-construction LTB rule requires it.
Check and takeaway. A pin-like beam connection can still cause an eccentric reaction moment in the column. Joint rotation and reaction location are separate facts.
Restraints define the analysis model
Choose an analysis model that represents the actual joints, restraints and possible sway.
Prediction, then explanation. A joint that permits beam rotation does not automatically remove all column moment. Eccentric reactions may still bend the column.
First identify the joint behaviour. Next identify how horizontal forces reach the foundations. Then assess sway sensitivity using the course criterion.
Simple, continuous and semi-continuous construction describe joint modelling. Sway classification describes overall frame response.
Scope. The schematic does not establish restraint stiffness or a stability threshold. Use the stated data and classification rules.
Check and takeaway. An ideal straight frame may still require notional horizontal forces to represent imperfections under the applicable method.
Moment shape matters within one segment
Represent a nonuniform moment distribution in the applicable member-buckling equation.
Prediction, then explanation. Two segments can have equal peak moment but different distributions. Their equivalent moment factors can therefore differ.
Evaluate moments from the true whole-beam analysis at the required positions. Apply the exact table’s weights, signs and lower bound.
mLT is an LTB factor. mx and my belong to the specified flexural checks. They are not interchangeable.
Scope. Some rules use magnitudes; others require signed ordinates. A factor does not reduce the actual moment used in a local section check.
Check and takeaway. Measure quarter points from the segment start, not automatically from the beam’s left support.
Apply the reasoning to this section’s data and conditions
Both papers use 305 × 305 × 158 UC, but they do not give the moments in the same way.
In 2022, signed end moments are supplied.
Use the continuous non-sway branch conditionally.
In 2023, eccentric beam reactions act at a joint.
Use the course simple-construction model, share the joint moment by stiffness, and use the explicitly given moment factors.
Physical interpretation and limits
A short steel block may survive squeezing while a long ruler with the same cross-section bends sideways.
The section check asks whether the steel at one slice is strong enough.
The member checks also ask whether the whole column can buckle.
Passing one does not replace the others.
These are lookups from the exact UC row.
The flange thickness selects the S355 design strength 345 N/mm².
A is area, r radius of gyration, Z elastic modulus, S plastic modulus, T flange thickness and t web thickness. u and x are the LTB section parameters, not geometric coordinates.
Given end moments and amplification
Compression acts on the displaced shape
A compressed member moves away from its initial load line. Explain why the bending moment can increase.
Prediction, then explanation. At fixed axial force, a larger offset creates a larger additional moment. This can further increase the displacement.
Force acting through an offset forms a moment. Second-order analysis includes that changed geometry in equilibrium.
P is axial force. Δ and δ are the relevant perpendicular displacements. Consistent force and length units give moment units.
Scope. Use the amplification or analysis method stated for the frame. Do not amplify an already amplified moment a second time.
Check and takeaway. Zero offset removes this additional moment in the ideal sketch. Real design may still require imperfections and code checks.
Apply the reasoning to this section’s data and conditions
Given effective height 4.5 m and axial force 3,000 kN.
Clockwise applied end moments are positive: x-axis top −90, bottom +70 kN·m; y-axis top −60, bottom −50 kN·m.
Amplification factors are 1.10 and 1.15.
The stated LTB moment is 99 kN·m.
Keep first-order moments separate from amplified ones.
BQ2(a) — section class [4 marks]
Find which plate buckles first
Before using plastic bending resistance, check whether the flange and web can sustain the required stress distribution.
Prediction, then explanation. At fixed width, a thinner plate has a larger width-to-thickness ratio. Local buckling then becomes more restrictive.
Calculate the flange and web ratios separately. Compare each with the limits for its stress condition. The worse class governs.
py is the design yield strength in N/mm². ε is a dimensionless scale used in the supplied classification limits.
Scope. Pure bending and uniform compression use different web limits. Class 2 allows plastic resistance but not the Class 1 rotation capability.
Check and takeaway. A Class 1 web and Class 2 flange give a Class 2 section. Do not average the class numbers.
Apply the reasoning to this section’s data and conditions
The web receives axial compression and bending stress together.
Use the Class 1 general-stress expression for this combined stress state.
Its stress-ratio parameter is capped at one.
The most restrictive web bound is 40ε.
The web thickness is below 16 mm.
Therefore, its S355 strength is 355 N/mm².
The flange uses 345 N/mm².
Both satisfy Class 1 limits for this combined axial-force-and-bending branch.
BQ2(b) — cross-section capacity [7 marks]
Use the same mechanism: Compression acts on the displaced shape. At fixed axial force, a larger offset creates a larger additional moment. This can further increase the displacement.
Check buckling about both axes
Determine which buckling direction limits the compressed member.
Prediction, then explanation. At fixed radius, longer effective length raises slenderness. The supplied buckling curve generally gives lower compressive strength.
Calculate slenderness about each axis. Select each axis’s curve from section type and thickness. Then obtain and compare the two compressive resistances.
Effective lengths and radii use mm. pc is compressive strength in N/mm²; Ag is gross area in mm²; Pc is in N.
Scope. Do not select the governing axis using radius alone. Effective length and buckling curve can differ. A combined column also needs interaction checks.
Check and takeaway. A short-section yield resistance is not the same as long-member buckling resistance. Keep py and pc distinct.
Apply the reasoning to this section’s data and conditions
The cross-section check combines axial compression and two bending components at one section.
Use amplified moments, gross compression resistance and the Class 1 capped plastic bending resistances.
Every ratio must be dimensionless.
The section passes this branch.
The minor-axis elastic cap controls; using the uncapped plastic value there would overstate resistance.
BQ2(c) — member buckling [19 marks]
A strong cross-section can belong to an unstable member
A column carries axial compression and bending. Explain why more than one check is required.
Prediction, then explanation. At fixed moments and resistances, increasing compression increases utilisation. A section pass cannot remove the length-dependent instability checks.
Separate cross-section, flexural-buckling and LTB interaction equations. Use each equation’s own denominators and first-order or amplified moments.
is a section axial resistance. is a member compression resistance. Elastic and prescribed are different bending denominators.
Scope. Preserve the course barred-moment definitions and Eq. 8.81 convention. Do not substitute plastic moduli into an elastic denominator.
Check and takeaway. Report each requested utilisation and the governing check. The largest properly calculated ratio identifies the closest limit.
Apply the reasoning to this section’s data and conditions
For the rolled UC with flange thickness below 40 mm, choose strut curve b about x and curve c about y.
Effective length divided by the corresponding radius gives slenderness.
Use the 345 N/mm² column of each curve’s compression-strength table.
Choose Data File p.8, curve b.
Interpolate between the two surrounding slenderness rows in the same design-strength column.
Do not mix columns.
Choose Data File p.8, curve c.
Interpolate between the two surrounding slenderness rows in the same design-strength column.
Do not mix columns.
Moment factors use the internal bending diagram, not the raw clockwise arrows at opposite end faces.
Hold the top sign and reverse the bottom-face applied moment when forming the internal end ratio.
For x this gives same-sign internal end moments.
For y, opposite-sign.
Then select the positive or negative ratio branch of Table 8.9.
Use the continuous-column LTB branch with the stated effective height, and the section u/x parameters.
Do not substitute the simple-construction half-height rule.
Choose Data File p.5, Table 8.3, 345 N/mm² column.
Interpolate between the two surrounding slenderness rows in the same design-strength column.
Do not mix columns.
For the member interaction equations, the course uses ELASTIC section bending resistances.
These are different from the capped plastic resistances used in the section check.
The first member equation uses the smaller compression resistance and amplified moments.
The second member equation combines minor-axis compression buckling with major-axis LTB.
It uses MLT as stated above and the first-order minor-axis moment (the barred moment in the course summary).
Do not insert the amplified minor-axis moment again.
Both member equations pass in the stated branch.
Retain the source qualification.
A numerical pass cannot remove a missing or contradictory input.
Result and concise exam wording
Use the same mechanism: Moment shape matters within one segment. Two segments can have equal peak moment but different distributions. Their equivalent moment factors can therefore differ.
A table value has conditions
Find a design property without mixing a row, column or standard from a different case.
Prediction, then explanation. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.
Match the complete section designation. Read the relevant axis and unit. For strength tables, select material, thickness and curve before interpolating.
Given values come from the question. Lookup values come from a named table. Assumed values require an explicit condition.
Scope. A missing row or omitted restraint cannot be recovered from a schematic’s scale. Keep the result conditional when required data are absent.
Check and takeaway. Record the table, row, column and unit beside the substitution. That makes a later check possible.
Apply the reasoning to this section’s data and conditions
Concise exam wording
All are below one under the stated interpretation.
Give the table brackets, moment factors and source qualification in the script.
Misconceptions and checks
Vertical bending can trigger sideways motion
A beam has enough local bending resistance. Check whether its compression flange can move sideways and twist.
Prediction, then explanation. Adding a valid lateral restraint shortens a stability segment. It need not change the beam’s vertical reaction or moment diagram.
Identify the compressed flange and effective restraints. Calculate the specified slenderness, read buckling strength and compare resistance with the segment demand.
LE and ry use the same length unit. pb uses N/mm²; Sx uses mm³; Mb uses N·mm. mLT is dimensionless.
Scope. Use the specified section class, effective-length branch and loading condition. Load height alone does not prove a destabilizing case.
Check and takeaway. Removing a lateral restraint requires a new segment stability check. The old shorter-segment result cannot establish the longer segment’s adequacy.
Use the same mechanism: Check buckling about both axes. At fixed radius, longer effective length raises slenderness. The supplied buckling curve generally gives lower compressive strength.
Use the property for the physical question
A section table contains several numbers. Choose the property that matches the calculation and bending axis.
Prediction, then explanation. Moving equal area away from an axis increases I about that axis. It does not increase total area.
Each small area contributes its area multiplied by squared distance. Sum those contributions to obtain I.
I is second moment of area in mm⁴. y is distance from the chosen axis in mm. A is area in mm². r is radius of gyration in mm.
Scope. Z is elastic section modulus; S is plastic section modulus in this course. Neither is interchangeable with I.
Check and takeaway. A nominal section designation is a row identifier. Use the actual dimensions and units in that exact row.
Apply the reasoning to this section’s data and conditions
- Never interchange elastic and plastic modulus denominators between section and member checks.
- Only joint moment is shared between upper/lower columns; axial load is not halved.
- For the 2023 simple model, LTB uses 4.5 m actual height, compression uses 4.0 m effective length.
Procedure for a new variant
Use the same mechanism: Compression acts on the displaced shape. At fixed axial force, a larger offset creates a larger additional moment. This can further increase the displacement.
Use the same mechanism: Vertical bending can trigger sideways motion. Adding a valid lateral restraint shortens a stability segment. It need not change the beam’s vertical reaction or moment diagram.
A force couple carries moment
Separate the force couple used to carry moment from the force used to carry web shear.
Prediction, then explanation. For the same moment, a larger lever arm requires a smaller couple force. It does not remove the web shear.
Moment is force multiplied by perpendicular separation. Divide the required moment by the specified separation to obtain each couple force.
M is moment in kN·mm; z is the specified force-line separation in mm; F is force in kN.
Scope. Use the lever arm defined by the source model. Do not silently replace it with overall section depth or another geometric distance.
Check and takeaway. Check flange welds for the couple forces and web welds for the stated shear model. Both force paths need a satisfactory detail.
Apply the reasoning to this section’s data and conditions
- Determine the construction model, axes and signs.
- Separate first-order, amplified and LTB moments.
- Look up both strut curves and the applicable LTB strength.
- Perform section and both member equations; state conditions.
Prediction with explained answer — invented variant
Two simultaneous actions use one component
Check a component that carries shear and tension, or compression and bending, at the same time.
Prediction, then explanation. At fixed resistances, increasing one demand increases its utilisation. The permitted sum is not always one.
First apply the individual checks. Next use the exact combined equation and its definitions. Keep demands from the same load case.
This is the course bolt interaction rule. Fs and Ft are bolt demands; Ps and Pnom are their specified resistance denominators.
Scope. The 1.4 limit and nominal tension denominator do not apply to column equations. Their limits and moment definitions are separate.
Check and takeaway. A sum above one can pass this bolt rule while still needing individual checks. A pass must name the actual equation used.
Apply the reasoning to this section’s data and conditions
Invented variant: in the 2023 joint, the lower column is twice as stiff as the upper.
What changes before any strength check?
Hint
Use lower stiffness divided by total stiffness.
Answer and reasoning
All interaction ratios must be recalculated.
The load share is based on stiffness; equal halves would now be wrong.