Getting started: the question, symbols, units and tables
Four things to get right before any calculation: the words of the question, the symbols, the units and the tables.
What the words in the question ask for
The questions and the Data File are in English. A few words decide which calculation you must do; miss one and every later step may use the wrong number. Circle the words in the table below before you start.
The most important thing is whether a load has already been multiplied by its load factor. A dead load and an imposed load are unfactored: multiply them by 1.4 and 1.6 before a strength check. An ultimate load, factored load or design load has already been multiplied: use it as it is.
The second thing is whether you must check or design. "Check" or "is adequate" means the sizes are given: work out the capacity and compare it with the demand. "Determine", "find the size" or "design" means working back from the demand to the size or number needed, then choosing a standard size not smaller than that.
| Words in the question | Meaning | What you do |
|---|---|---|
| dead load, permanent load | the weight that is always there | unfactored; multiply by 1.4 for strength |
| imposed load, live load | the load from use | unfactored; multiply by 1.6 for strength, use as it is for deflection |
| ultimate load, factored load, design load | a load already multiplied by its factor | use it as it is; do not multiply by 1.4 or 1.6 again |
| check, is adequate | the sizes are given | work out the capacity, compare with the demand, state the result of every check |
| determine, find the size, design | the size or number is wanted | work back from the demand, then choose a standard size |
| Grade S355 | steel grade | read the design strength from the Data File by grade and thickness |
| Grade 8.8, M20 | bolt grade, bolt diameter 20 mm | read strengths and areas from the bolt tables |
| single shear, double shear | one or two shear planes | each bolt is cut on one plane or on two |
| fillet weld, leg length | triangular weld and the length of its leg | the throat is 0.7 times the leg |
| simply supported | free to rotate at both ends | vertical reactions only, no end moments |
| laterally restrained, unrestrained | held sideways, or not | an unrestrained length needs a lateral-torsional buckling check |
| effective length | length used for buckling | multiply the actual length by a factor for the end conditions |
| UB, UC | universal beam, universal column | find its row in the section tables and copy the dimensions and properties |
Reading the symbols: small p is a strength, capital P is a capacity
Steel design formulas seem to have many symbols, but there are only a few families. Once you know which family a letter belongs to, you know its unit and which side of the comparison it goes on.
The most useful rule: a small with a subscript is a strength, the force one square millimetre of steel can take, in N/mm², read from the Data File. A capital with a subscript is a capacity, the force a whole bolt, plate or column can take, in kN, found as strength times area. A capital with a subscript is a demand, the force the loads really put on it, also in kN. Every check ends by comparing a demand with a capacity.
The subscript says which action: for shear, for bearing, for tension, for compression, for weld, for yield. So is the shear strength of a bolt, the shear capacity of one bolt, and the shear force one bolt has to carry.
Greek letters are just more names. The table below gives the ones used in this course, how to say them and what they stand for.
| Written as | Family | Unit | Examples in this course |
|---|---|---|---|
| small with a subscript | strength: force per mm², read from the Data File | N/mm² | , , , , , , |
| capital with a subscript | capacity: force the whole part can take | kN | , , , , |
| capital with a subscript | demand: force caused by the loads | kN | , |
| , | shear demand and shear capacity of a beam | kN | , |
| with a subscript | moment: , are demands; , are capacities | kNm | , , |
| with a subscript | area | mm² or cm² | , , , , |
| , | section modulus: turns a strength into a moment capacity | cm³ | , |
| , | second moment of area, radius of gyration | cm⁴, cm | , |
| Letter | Say | Stands for |
|---|---|---|
| epsilon | the factor used in section classification, | |
| lambda | slenderness, ; the larger it is, the more easily the member buckles | |
| lambda LT | the equivalent slenderness for lateral-torsional buckling | |
| beta | the ratio of the two end moments of a length, used to enter a table | |
| delta | deflection, how many mm the beam sags | |
| sigma | add the terms together | |
| eta | utilisation, demand divided by capacity |
Use units to identify what you are calculating (Units and Dimensions)
Do not start by memorising formulas. Every engineering quantity needs both a magnitude and a physical meaning: 20 kN is a force, 20 kN/m is force per metre of length, and 20 kN/m² is force per square metre. You cannot add these directly. Writing units at every step helps you catch mistakes before using a calculator.
1 kN=1000 N and 1 m=1000 mm. For area, square the length conversion: 1 cm²=100 mm². For volume or section modulus, the cubic conversion is 1 cm³=1000 mm³; for second moment of area , 1 cm⁴=10000 mm⁴. Do not simply multiply by 10 whenever you see cm.
The course section tables commonly use cm², cm³ and cm⁴, whereas material strength is in N/mm². Strength times area gives N; strength times section modulus gives Nmm. Only at the end divide N by 1000 to obtain kN, and Nmm by 1000000 to obtain kNm.
Line loads have a convenient equivalence: 1 kN/m=1000 N/1000 mm=1 N/mm. The numerical values are equal, but this does not mean that unit conversions can generally be omitted.
Reading a table and interpolating
Many values are not calculated but read from the tables of the Data File, such as the design strength , the compressive strength and the bending strength . The routine is always the same: use the data of the question to choose the column, usually the value of ; then use the value you have calculated to choose the row, for example the slenderness . The cell where they meet is the answer.
A table lists round values only, such as equal to 40, 45, 50. Your value usually falls between two rows, such as 42.8. Then you interpolate: assume the change between the two rows is a straight line and take the value in proportion to the distance.
Three steps. First, find the rows above and below and copy four numbers: the two row headings and their table values. Second, work out what fraction of the way your value is from the upper row. Third, move the table value by the same fraction. When the table values fall as the rows go up, the result is smaller than the value of the upper row.
Then look at the result: it must lie between the two table values. If it does not, the sign is usually wrong.
| Symbol / Unit | Meaning |
|---|---|
| the value you calculated, for example | |
| , | the headings of the rows above and below |
| , | the table values of those two rows |
| the interpolated table value |