Connections and stability
How bolts and welds pass the force on, and why a slender member becomes unstable before the steel is crushed.
Several failure paths in a bolted connection (Bolted Connections)
In an ordinary bearing-type bolted connection, the plates transfer force to the bolts through contact at the hole walls. Failure may occur through bolt shear, bearing at the holes, tearing at a plate end or net-section rupture. Each mode uses different effective areas , dimensions and strengths.
Count shear planes from the side view. Two overlapping plates usually give one shear plane; a main plate sandwiched between two cover plates commonly gives two. The number of shear planes and the number of bolts are independent quantities.
Hole diameter is normally larger than bolt diameter . Use the course's tabulated effective area for bolt shear, deduct hole diameter for plate net area , and use as defined in the bearing expression. Confusing these three areas is a common beginner's mistake.
| Symbol / Unit | Meaning |
|---|---|
| Number of effective shear planes per bolt | |
| Bolt design shear strength | |
| Specified shear area in this course, mm² |
How holes weaken a steel plate (Net and Effective Area)
Take a section perpendicular to the tensile force and identify the steel remaining to transmit it. Gross area is the area before deducting holes. Net area is the area remaining after deducting the holes intersected by the failure path.
For a straight path through circular holes in a plate of thickness , deduct . This removes the hole widths from the tensile section, not the circular plan areas π. Staggered holes or other failure paths require more than this one straight-line check.
Effective area is a design quantity obtained by further adjusting the net area for the material and connection form used in this course. must not exceed . An angle connected through only one leg also requires a reduction for its outstanding leg. These factors are design rules, not purely geometric definitions of area.
| Symbol / Unit | Meaning |
|---|---|
| Plate width | |
| Hole diameter | |
| , , | Net, effective and gross areas |
Leg size, throat and effective length (Fillet Weld Geometry)
The visible side dimension of a fillet weld is its leg size . The course takes effective throat as approximately . For the same weld length, a larger throat gives more effective area for force transfer. A 6 mm leg is not a 6 mm effective throat.
is weld design strength, obtained from the parent material and the course electrode classification table. Resistance per millimetre of effective weld length is in kN/mm. For a total force shared by similar welds, the initial total effective-length requirement is .
Effective weld length differs from the actual length provided. In some course examples, is added to effective length before rounding up to a practical size, followed by checks of minimum length, lap and end returns. An eccentric weld group also needs moment components; total force divided by total length alone is insufficient.
| Symbol / Unit | Meaning |
|---|---|
| Weld leg size, mm | |
| Weld strength, N/mm² | |
| Resistance per unit weld length, kN/mm |
Instability can precede material crushing (Buckling)
Yielding describes a material reaching the relevant stress state; buckling describes a compression member losing its original stable shape. A long ruler compressed lengthwise may bend sideways before all its material is crushed. This is why alone cannot assess a slender column.
Effective length represents the influence of actual end restraints on the buckling shape. It may equal, be shorter than or exceed the physical length, depending on the supports and sway conditions. Slenderness ratio combines length with the section's material distribution.
The course selects a buckling curve by section type, thickness and axis, then reads compressive strength from and . Complete the lookup for each axis before comparing capacities. already includes the reduction from that buckling method; do not treat it as .
| Symbol / Unit | Meaning |
|---|---|
| Compressive strength reduced for buckling | |
| Member compression resistance | |
| Effective-length factor, |
Why a beam moves sideways and twists (Lateral-torsional Buckling)
When a beam bends, one flange is in compression. Without adequate lateral restraint, that flange may move sideways and twist the whole section, causing lateral-torsional buckling (LTB). Adequate cross-sectional bending resistance does not rule out this overall instability.
Locate the lateral and torsional restraints in the drawing before assigning an effective length to each unrestrained segment. The course uses , , , and to convert ordinary slenderness to equivalent slenderness , then reads and calculates . Obtain these parameters from the course method and section tables rather than guessing.
Moment may vary along the unrestrained segment, so an equivalent moment factor adjusts demand. Compare with : acts on demand and on resistance; they are not interchangeable. Select the table case matching the actual bending moment diagram.
| Symbol / Unit | Meaning |
|---|---|
| Parameter depending on section class; commonly 1 for Class 1/2 in this course | |
| Bending buckling strength | |
| Equivalent moment factor |
Combined axial force and bending (Interaction Checks)
A column may bend as well as carry compression because of eccentric beam reactions or frame action. Axial force and bending about both axes draw on its resistance simultaneously. Each separate demand being below its individual capacity does not establish that the combined action passes.
The course uses interaction equations that add dimensionless demand-to-resistance ratios. Section checks use and the corresponding section moment capacities . Member checks use , specified elastic capacities, and moment factors. Similar-looking expressions have different denominators and conditions of use.
Moment amplification addresses the additional effects required by the problem; equivalent moment factors describe the moment distribution. Amplify demand as specified, then apply the factors required by the chosen interaction equation. A sum greater than 1 fails that equation; an oral description of “marginal” does not relax the limit.
| Symbol / Unit | Meaning |
|---|---|
| Design axial compression force | |
| , | Bending moments about both axes for the same design situation |
| , | Must follow the definitions in the selected check |