STEELWORK / CON4334
Worked examples

2024 AQ1: compulsory floor-beam design and theory

Open “Animation lab” beside a teaching step for a visual explanation or a walkthrough of its original expressions. Models are illustrative; source answers remain unchanged.

Chinese–English terminology

Need a simpler picture? Open “Simple explanation” beside a difficult step. These optional notes do not replace the full solution.

Complete the 40-mark compulsory question. Slab thickness 180mm, concrete unit weight 24.5kNm3, finishes 0.4kNm2, imposed load 4.5kNm2. B1 is 356×127×39 UB and B2 as 406×140×46 UB, all S355. Include self-weight using g=10ms2. The beams are simply supported, fully laterally restrained and carry brittle finishes.

Original source: Pastpaper/23ENGTY004.pdf — p. 2. Values tagged given are in the question or diagram; lookup values come from a named table; calculated values follow from the working; assumptions are stated explicitly.

Read the diagram and collect the data

Input typeExact source feature
Given slab dataQuestion paragraph:180mm thickness,24.5 unit weight,finish 0.4,imposed 4.5.
Given supports/spansDimension chains and column symbols inFigureAQ1; use the explanation alongside the original crop.
Calculated widthsInterior B1 tributary width 2.52+2.52=2.5m.
Lookup self-weightData File p.9 gives B1 mass 39.1kgm;B2 mass 46kgm. Nominal section labels may round the mass.
Method applicabilitySlab is expressly a full lateral restraint; no composite-section enhancement is assumed.

Before calculating: recognition and strategy

This compulsory family tests the same chain repeatedly: slab intensity → tributary beam line load → reaction onto supporting beam → section class → shear/bending → imposed-only deflection. Work from the actual plan orientation; the names B1/B2 alone do not tell you which way a beam spans.

(a)(i) Slab factored intensity —4 printed marks

Simple explanation: Why dead and imposed loads stay separate

Keep two shopping baskets until their different multipliers are applied.

Why dead and imposed loads stay separate — Keep two shopping baskets until their different multipliers are applied.
Original teaching sketch • not to scale • click to enlarge. Use the question’s original diagram for all dimensions.
  1. Put self-weight and permanent finishes in the dead-load basket.
  2. Put the specified use load in the imposed-load basket.
  3. For this course’s stated gravity combination: 1.4G+1.6Q.

Remember: That ULS combination is not the imposed-load deflection load.

Related concept and full method

Slab thickness: 180mm=0.18mConcrete dead load: 0.18×24.5=4.41kNm2gk=4.41+0.4=4.81kNm2qk=4.5kNm2Ultimate area load: 1.4×4.81+1.6×4.5=13.934kNm2

Concrete unit weight is in kNm3, so multiply by slab thickness in metres to obtain kNm2. A surface intensity is not yet a beam line load; the next step supplies the tributary width.

Animation labFrom characteristic to design load1 concept · 1 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. G is permanent load; Q is imposed load. A surface load and a line load also have different units.
  2. This illustration uses the course gravity case . Other combinations in the original text retain their own factors.
  3. For illustrative , change Q and watch each separate contribution.
  4. Do not carry this ULS total automatically into deflection. Follow the stated SLS load case.

(a)(ii) Verify B1 actions —3 printed marks

Tributary width: 2.52+2.52=2.5mB1 self-weight: 39.1kgm×10ms21,000=0.391kNmDead line load: 4.81×2.5+0.391=12.416000kNmImposed line load: 4.5×2.5=11.25kNmUltimate line load: w=1.4×12.416000+1.6×11.25=35.382400kNmReaction at each end: R=wL2=35.382400×72=123.838400kNVmax=R=123.838400kNShear V(x)=Rwx lie on opposite sides of the x=3.5m is zero at this position.Mmax=wL28=35.382400×728=216.717200kN·m

Here 39kgm is the nominal designation; the exact section-table mass is 39.1kgm. Use one stated convention consistently. B1’s vertical support spacing is 7m even though the slab tributary width is 2.5m.

Rounded to one decimal place, V=123.8kN andM=216.7 kNm, matching the paper’s 123.8/216.7. These are printed target values, not an official full solution.

Animation labFollow the floor load in 3D4 concepts · 2 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. The floor carries pressure in . The highlighted strip belongs to one secondary beam.
  2. Multiply pressure by tributary width: . The illustration uses .
  3. A primary beam receives the secondary beam reaction at their connection, not a new full-span UDL.
  4. Trace reactions down to columns and foundations. Count each loaded area once.

(a)(iii) Verify B2 actions —5 printed marks

Simple explanation: How a floor load reaches a beam

Each beam collects the load from its own strip of floor.

How a floor load reaches a beam — Each beam collects the load from its own strip of floor.
Original teaching sketch • not to scale • click to enlarge. Use the question’s original diagram for all dimensions.
  1. Find the tributary width from the actual plan.
  2. Area load × tributary width gives load per beam length.
  3. A supporting beam receives the other beam’s end reaction.

Remember: A reaction becomes a point load, not automatically a UDL.

Related concept and full method

Each B2 receives one B1 end reaction at midspan, P=123.838400kN. B2 self-weight: 46×101,000=0.46kNmB2 ultimate UDL: w=1.4×0.46=0.644kNmSpan: L=2.5+2.5=5mReaction at each end: R=P2+wL2=123.8384002+0.644×52=63.529200kNVmax=63.529200kNMmax=PL4+wL28=123.838400×54+0.644×528=156.810500kN·m

The transferred P is already factored. Do not factor it again. The full-span UDL on B2 here is only its own weight: the one-way slab loads pass through B1 or arrive at supported end joints, rather than being spread arbitrarily along B2.

Rounded to one decimal place, V=63.5kN andM=156.8 kNm, matching the paper’s 63.5/156.8. Retain the unrounded actions for the following checks.

Animation labFollow the floor load in 3D4 concepts · 2 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. The floor carries pressure in . The highlighted strip belongs to one secondary beam.
  2. Multiply pressure by tributary width: . The illustration uses .
  3. A primary beam receives the secondary beam reaction at their connection, not a new full-span UDL.
  4. Trace reactions down to columns and foundations. Count each loaded area once.

(a)(iv) Both section classes —4 printed marks

Simple explanation: A thin part can wrinkle first

A thin plate may wrinkle before the whole steel member reaches its intended resistance.

A thin part can wrinkle first — A thin plate may wrinkle before the whole steel member reaches its intended resistance.
Original teaching sketch • not to scale • click to enlarge. Use the question’s original diagram for all dimensions.
  1. Check flange and web slenderness using their own definitions.
  2. Compare each ratio with the correct class limits.
  3. The less favourable element determines the section class.

Remember: Bending limits and uniform-compression limits are different.

Related concept and full method

Lookup: Data File pp.9–10, exact 356×127×39 UB row. Dimensions on p.9; properties on p.10. D is overall depth; d is the clear web depth between root fillets, not the nominal designation.

PropertyLookup value / conversion
DimensionsD353.4, web t 6.6, flange T10.7, root r 10.2, clear d 311.6, all mm
Local ratiosbT=5.89dt=47.2
Major-axis propertiesIx=10170cm4=1.017×108mm4; Zx=576cm3; Sx=659cm3.
LTB propertiesry=2.68cm=26.8mm; u=0.871; torsional index x=35.2.
S355, flange T=10.7mm, giving py=355Nmm2. ε=275355=0.880141Flange: bT=5.89<9ε=7.921268Web in bending: dt=47.2<80ε=70.411267Both are Class 1, so βW=1; plastic bending resistance is permitted.dt=47.2<70ε=61.609858No separate shear-buckling calculation is needed under the course limit.

Lookup: Data File pp.9–10, exact 406×140×46 UB row. Dimensions on p.9; properties on p.10. D is overall depth; d is the clear web depth between root fillets, not the nominal designation.

PropertyLookup value / conversion
DimensionsD403.2, web t 6.8, flange T11.2, root r 10.2, clear d 360.4, all mm
Local ratiosbT=6.35dt=53
Major-axis propertiesIx=15690cm4=1.569×108mm4; Zx=778cm3; Sx=888cm3.
LTB propertiesry=3.03cm=30.3mm; u=0.871; torsional index x=38.9.
S355, flange T=11.2mm, so py=355Nmm2. ε=275355=0.880141Flange: bT=6.35<9ε=7.921268Web in bending: dt=53<80ε=70.411267Both are Class 1, so βW=1; plastic moment resistance is permitted.dt=53<70ε=61.609858No shear-buckling calculation is required under the course limit.

Both beams are Class 1. No Class 4 effective-property calculation is needed. Full slab lateral restraint, given in the paper, removes the LTB requirement for these floor-beam questions; it does not remove local shear/bending or deflection checks.

Animation labWhy thin elements buckle locally1 concept · 18 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. The flange outstand and web have different widths, thicknesses and edge support conditions.
  2. A thinner plate can wrinkle locally before the complete member loses stability.
  3. Class 1 allows plastic rotation; Class 2 reaches plastic resistance; Class 3 reaches elastic resistance; Class 4 requires effective properties.
  4. Check every relevant compression element with the supplied limits and stress distribution. The deformation shown is qualitative.

(a)(v) B1 adequacy —10 printed marks

Simple explanation: Why one flange squeezes and the other stretches

Bending makes opposite sides of the section do opposite jobs.

Why one flange squeezes and the other stretches — Bending makes opposite sides of the section do opposite jobs.
Original teaching sketch • not to scale • click to enlarge. Use the question’s original diagram for all dimensions.
  1. Find the moment from the actual loads and supports.
  2. Choose the resistance formula allowed by the section class.
  3. Check whether the coexistent shear changes that formula.

Remember: Use shear at the location being checked, not an unrelated maximum.

Related concept and full method

Av=tD=6.6×353.4=2332.44mm2Vc=pyAv3=355×2332.443×1,000=478.055376kNVmax=123.838400kN<VcShear passes.0.6Vc=286.833226kN>VmaxEven peak shear is low, so the low-shear bending expression applies throughout the beam.Mc=min(pySx,1.2pyZx)=min(355×6591,000,1.2×355×5761,000)=min(233.945,245.376)=233.945kN·m|M|max=216.717200kN·mBending passes.
B1 imposed line load: q=4.5×2.5=11.25kNm=11.25NmmL=7,000mmE=205,000Nmm2Ix=10,170×104mm4δB1=5qL4384EI=5×11.25×7,0004384×205,000×10,170×104=16.869750mmBrittle-finish limit: 7,000360=19.444444mm16.869750<19.444444: passes.
Animation labSee shear in the web4 concepts · 2 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. Internal shear keeps the two sides of the cut in vertical equilibrium.
  2. For the course’s common I-section case, the web provides the principal shear area; use the specified definition.
  3. A slender web may require a different shear-buckling route before a simple shear-resistance formula is used.
  4. Use where applicable in the course. Convert N to kN before comparing with design shear.

(a)(vi) B2 adequacy —10 printed marks

Simple explanation: How much does the beam sag?

Strength asks whether it fails; deflection asks how far it moves.

How much does the beam sag? — Strength asks whether it fails; deflection asks how far it moves.
Original teaching sketch • not to scale • click to enlarge. Use the question’s original diagram for all dimensions.
  1. Use the serviceability load case specified by the course question.
  2. Choose the expression matching the support and load positions.
  3. Use consistent units for load, length, E and I.

Remember: The largest deflection is not always at midspan.

Related concept and full method

Av=tD=6.8×403.2=2741.76mm2Vc=pyAv3=355×2741.763×1,000=561.949335kNVmax=63.529200kN<VcShear passes.0.6Vc=337.169601kN>VmaxEven peak shear is low, so the low-shear bending expression applies throughout the beam.Mc=min(pySx,1.2pyZx)=min(355×8881,000,1.2×355×7781,000)=min(315.24,331.428)=315.24kN·m|M|max=156.810500kN·mBending passes.
B1 reaction delivered to B2, imposed load only: Pq=(4.5×2.5)×72=39.375kNL=5,000mmIx=15,690×104mm4δB2=PL348EI=39375×5,000348×205,000×15,690×104=3.187958mmBrittle-finish limit: 5,000360=13.888889mm3.187958<13.888889: passes.
Animation labSee shear in the web4 concepts · 2 source expressions

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. Internal shear keeps the two sides of the cut in vertical equilibrium.
  2. For the course’s common I-section case, the web provides the principal shear area; use the specified definition.
  3. A slender web may require a different shear-buckling route before a simple shear-resistance formula is used.
  4. Use where applicable in the course. Convert N to kN before comparing with design shear.

(b) Sketch and name four hot-rolled sections —4 printed marks

Original Ch1 p.4 section sketches. For this answer identify the UB, UC, channel and angle profiles.
Original section sketches, Ch 1 p.4. This question asks you to recognise UB, UC, channel and angle profiles. English labels identify Universal Beam, Universal Column, Channel, Equal/Unequal Angle, Structural Tee cut from UB, and Circular/Square/Rectangular Hollow Section. Selectable equivalents of the dimension labels follow. They retain the source ranges, not design inputs for this question: UB D×B is 203×133 to 914×419; UC D×B is 152×152 to 356×406; channel D×B is 76×38 to 432×102; equal angle A×A is 25×25 to 250×250; unequal angle A×B is 40×25 to 200×150; tee B×A is 133×102 to 305×457; circular hollow section D is 21.3 to 457; square hollow section D×D is 20×20 to 400×400; rectangular hollow section D×B is 50×30 to 450×250. The individual arrows identify overall depth, overall width or angle-leg length. Do not measure additional dimensions from drawing scale.Open full-size image
NameShape to sketch and label
Universal beam (UB)An I profile, generally relatively deep with narrower flanges: web and two flanges.
Universal column (UC)An H/I profile with relatively broad flanges and similar width/depth; label it distinctly from UB.
ChannelA C/U profile with one web and two flanges on the same side.
AngleAn L profile with two perpendicular legs; specify equal or unequal angle.

Draw recognizable cross-section outlines and place the name beside each. Do not count rotating the same I section as a new section family. The question asks names and sketches; numerical capacity design is not required.

Animation labExplore section geometry and axes1 concept

Supplement to the original lesson. Enable JavaScript to play, step through calculations and rotate 3D models. The following explanation remains readable offline.

  1. The flanges are the wide plates; the web connects them. Rotate the I-section to see both.
  2. The same section has different stiffness and resistance about its two principal axes.
  3. I controls elastic curvature; is elastic section modulus. Plastic modulus S comes from plastic stress blocks.
  4. Nominal section labels are not every actual dimension. Keep the row, axis and units together.

Compact exam answer

ResultB1B2
Ultimate line self/floor modelw=35.382400kNmP=123.838400kNw=0.644kNm
Maximum shear123.838400kN63.529200kN
Maximum moment216.717200kN·m156.810500kN·m
Section class11
Imposed deflection / limit16.86975019.444444mm3.18795813.888889mm
Requested adequacyPassPass

Slab gk=4.81,qk=4.5,ultimate=13.934kNm2. Use the theory explanations above for the 4-mark final part. A concise script should still show units, the plastic ceiling and the serviceability load choice.

Mistakes to avoid

  • Do not read a slab bay width as the supporting beam span.
  • Do not double-factor a transferred reaction.
  • Do not use design load in an imposed-only deflection equation.
  • Do not confuseI(cm4),Z(cm3) andS(cm3).
  • Passing bending does not prove that deflection passes.

Procedure for an unfamiliar variant

  1. Mark slab arrows, support points and member spans.
  2. Find dead/imposed surface and line loads separately.
  3. Transfer each supported beam’s reaction exactly once.
  4. Find ULS actions and classify each exact section.
  5. Check shear/low-shear bending and then imposed-only deflection.
  6. End with an explicit pass/fail statement and answer the short theory part.

Independent self-check

Try it yourself. Invented variant: increase only the imposed surface load 20%. What happens to the two deflection checks?

Reveal answer and reasoning

Multiply only the imposed-load deflection by 1.2: B1 becomes 20.243700mm, and B2 becomes 3.825549mm. Compare respectively with 19.444444 and 13.888889mm; at least one beam exceeds its limit. Recalculate strength actions using 1.4G+1.6×1.2Q. Dead load is unchanged, so do not multiply everything directly by 1.2.