Steelwork · Exam learning

2014–2019 · Reference answers

2019-01-08 — floor and foundations

All answers shown

Solve the complete compulsory question, using the original diagram beside the calculation.

Independent teaching answer, not an official solution or marking scheme.

Printed marks are retained.

Read the source conditions beside each result.

Read the load path first

Vertical bending can trigger sideways motion

A beam has enough local bending resistance. Check whether its compression flange can move sideways and twist.

The dashed straight line is the initial reference. The curved flange lines illustrate the labelled sideways movement and twist.
The dashed straight line is the initial reference. The curved flange lines illustrate the labelled sideways movement and twist.

Prediction, then explanation. Adding a valid lateral restraint shortens a stability segment. It need not change the beam’s vertical reaction or moment diagram.

Identify the compressed flange and effective restraints. Calculate the specified slenderness, read buckling strength and compare resistance with the segment demand.

λ=LE/ry,Mb=pbSx  (Class 1/2),mLTMmax≤Mb\lambda=L_E/r_y,\qquad M_b=p_bS_x\;\text{(Class 1/2)},\qquad m_{LT}M_{max}\le M_b

LE and ry use the same length unit. pb uses N/mm²; Sx uses mm³; Mb uses N·mm. mLT is dimensionless.

Scope. Use the specified section class, effective-length branch and loading condition. Load height alone does not prove a destabilizing case.

Check and takeaway. Removing a lateral restraint requires a new segment stability check. The old shorter-segment result cannot establish the longer segment’s adequacy.

Follow one strip of floor

An area load must become a beam load before beam reactions can be calculated.

The highlighted tributary strip supplies one beam. The right-hand labels show area load multiplied by width becoming line load.
The highlighted tributary strip supplies one beam. The right-hand labels show area load multiplied by width becoming line load.

Prediction, then explanation. At fixed area load, twice the tributary width gives twice the line load. An end reaction remains a concentrated force.

Consider one metre along the beam. The associated floor area is b square metres. Multiply area load by that width.

w=qbw=qb

q is area load in kN/m²; b is tributary width in m; w is line load in kN/m.

Scope. Determine b from slab spanning and supports. Add beam self-weight separately. A secondary-beam reaction is not automatically a UDL.

Check and takeaway. Illustration: 3 kN/m2×2 m=6 kN/m3\,\mathrm{kN/m^2}\times2\,\mathrm{m}=6\,\mathrm{kN/m}. The width cancels one length unit.

Keep load categories separate

A floor carries permanent material and changing occupancy loads. Find the design load for the stated check.

The two boxes show G and Q with their separate factors. The plus sign joins their factored values.
The two boxes show G and Q with their separate factors. The plus sign joins their factored values.

Prediction, then explanation. Increasing imposed load changes its own term. It does not change the dead-load factor or the steel stiffness.

First convert mass to weight where required. Next collect G and Q in compatible units. Apply the combination specified by the course problem.

Wu=1.4G+1.6QW_u=1.4G+1.6Q

G is characteristic dead load; Q is characteristic imposed load. Wu is the design load for this course gravity combination.

Scope. This combination is not universal. Use the specified service load for deflection and the stated factors for other standards or cases.

Check and takeaway. Illustration: G = 10 kN and Q = 5 kN give 22 kN. Factoring their sum by one guessed factor loses the distinction.

Apply the reasoning to this section’s data and conditions

The slab arrows point across adjacent B1 beams.

Each interior B1 collects half the 2.5 m bay on either side: tributary width 2.5 m.

Its labelled span is 6 m.

The supporting B2 spans 5 m between the drawn columns and receives 1 B1 end reaction(s), at its middle.

Beams aligned directly with a column deliver their end reaction to that column, not as an extra midspan load on B2.

The B2 point load is already factored.

Do not factor it again.

The slab gives full compression-flange restraint.

Therefore, this is section resistance rather than an LTB design.

Units: 1 kN = 1,000 N; 1 m = 1,000 mm; 1 cm³ = 1,000 mm³; 1 cm⁴ = 10,000 mm⁴.

Demand is the load effect.

Resistance is the permitted capacity for the selected failure mode.

Compare matching units.

Physical interpretation and limits

Think of a tray resting on small bars, then on two larger edge bars.

Follow where each bar ends: that determines which reaction goes onto the next bar.

Load intensity [4 marks]

Use the same mechanism: Keep load categories separate. Increasing imposed load changes its own term. It does not change the dead-load factor or the steel stiffness.

Apply the reasoning to this section’s data and conditions

Given slab thickness 120 mm, finishes 0.5 kN/m², imposed load 3 kN/m².

Convert thickness to metres.

Permanent area load includes concrete and finishes; beam weight is added later as a line load.

gk=hγc+gfin=0.12(24.5)+0.5=3.44 kN/m2g_k=h\gamma_c+g_{fin}=0.12(24.5)+0.5=3.44\,\mathrm{kN/m^2}
qu=1.4gk+1.6qk=1.4(3.44)+1.6(3)=9.616 kN/m2q_u=1.4g_k+1.6q_k=1.4(3.44)+1.6(3)=9.616\,\mathrm{kN/m^2}

Result and concise exam wording — key result lines

gk=hγc+gfin=0.12(24.5)+0.5=3.44 kN/m2g_k=h\gamma_c+g_{fin}=0.12(24.5)+0.5=3.44\,\mathrm{kN/m^2}
qu=1.4gk+1.6qk=1.4(3.44)+1.6(3)=9.616 kN/m2q_u=1.4g_k+1.6q_k=1.4(3.44)+1.6(3)=9.616\,\mathrm{kN/m^2}

Given slab thickness 120 mm, finishes 0.5 kN/m², imposed load 3 kN/m².

Convert thickness to metres.

Permanent area load includes concrete and finishes; beam weight is added later as a line load.

Beam actions [8 marks]

Use the same mechanism: Follow one strip of floor. At fixed area load, twice the tributary width gives twice the line load. An end reaction remains a concentrated force.

Balance the isolated beam

Find the two vertical reactions before calculating internal shear or moment.

A / RₐB / RᵦPaL
A and B are vertical supports. The downward load acts at distance a from A. Its distance from B is L − a.

Prediction, then explanation. Move the same load toward B. Reaction B increases because the load has a larger moment arm about A.

Take moments about A. Reaction A has zero lever arm there. Then use vertical force balance to find reaction A.

RBL=Pa,RA+RB=PR_B L=Pa,\qquad R_A+R_B=P

P, RA and RB are forces in kN. L is support spacing and a is load position, both in m.

Scope. These expressions describe one point load on a simply supported beam. Add other loads through equilibrium; keep their actual positions.

Check and takeaway. Illustration: P = 60 kN, L = 6 m and a = 2 m give RB = 20 kN and RA = 40 kN.

A table value has conditions

Find a design property without mixing a row, column or standard from a different case.

The row and column meet at one cell. The table heading supplies the units and the conditions that give the cell meaning.
The row and column meet at one cell. The table heading supplies the units and the conditions that give the cell meaning.

Prediction, then explanation. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Match the complete section designation. Read the relevant axis and unit. For strength tables, select material, thickness and curve before interpolating.

Given values come from the question. Lookup values come from a named table. Assumed values require an explicit condition.

Scope. A missing row or omitted restraint cannot be recovered from a schematic’s scale. Keep the result conditional when required data are absent.

Check and takeaway. Record the table, row, column and unit beside the substitution. That makes a later check possible.

Apply the reasoning to this section’s data and conditions

Source: Pastpaper/22ENGTY033.pdf · p.20, p.21

Lookup the exact 254 × 146 × 37 UB row.

Read dimensions first, properties second.

D = overall depth; t = web thickness; T = flange thickness; d = clear web depth.

The designation identifies a section-table row.

Read exact dimensions from that row.

D=256, t=6.3, T=10.9, d=219(mm)D=256,\ t=6.3,\ T=10.9,\ d=219\quad(\mathrm{mm})
b/T=6.72, d/t=34.8, Ix=5537 cm4, Zx=433 cm3, Sx=483 cm3b/T=6.72,\ d/t=34.8,\ I_x=5537\,\mathrm{cm^4},\ Z_x=433\,\mathrm{cm^3},\ S_x=483\,\mathrm{cm^3}
ry=34.8 mm,u=0.89,x=24.3r_y=34.8\,\mathrm{mm},\quad u=0.89,\quad x=24.3
Source: LectureNotes/CON4334-Data File-20260730.pdf · p.9, p.10

Lookup the exact 356 × 127 × 39 UB row.

Read dimensions first, properties second.

D = overall depth; t = web thickness; T = flange thickness; d = clear web depth.

The designation identifies a section-table row.

Read exact dimensions from that row.

D=353.4, t=6.6, T=10.7, d=311.6(mm)D=353.4,\ t=6.6,\ T=10.7,\ d=311.6\quad(\mathrm{mm})
b/T=5.89, d/t=47.2, Ix=10170 cm4, Zx=576 cm3, Sx=659 cm3b/T=5.89,\ d/t=47.2,\ I_x=10170\,\mathrm{cm^4},\ Z_x=576\,\mathrm{cm^3},\ S_x=659\,\mathrm{cm^3}
ry=26.8 mm,u=0.871,x=35.2r_y=26.8\,\mathrm{mm},\quad u=0.871,\quad x=35.2

Lookup mass in kg/m and multiply by g/1000 to get kN/m.

Multiply the slab area load by the tributary width, not by the full slab area.

wg1=37(10)/1000=0.37,wg2=39.1(10)/1000=0.391(kN/m)w_{g1}=37(10)/1000=0.37,\quad w_{g2}=39.1(10)/1000=0.391\quad(\mathrm{kN/m})
wu1=qub+1.4wg1=9.616(2.5)+1.4(0.37)=24.558 kN/mw_{u1}=q_ub+1.4w_{g1}=9.616(2.5)+1.4(0.37)=24.558\,\mathrm{kN/m}
V1=R1=wu1L1/2=24.558(6)/2=73.674 kNV_1=R_1=w_{u1}L_1/2=24.558(6)/2=73.674\,\mathrm{kN}
M1=wu1L12/8=24.558(62)/8=110.511 kN mM_1=w_{u1}L_1^2/8=24.558(6^2)/8=110.511\,\mathrm{kN\,m}

For B2 use superposition: the B1 point reactions plus B2 self-weight.

Equilibrium divides the symmetric total load equally between the supports.

wu2=1.4(0.391)=0.5474 kN/m,P=R1=73.674 kNw_{u2}=1.4(0.391)=0.5474\,\mathrm{kN/m},\quad P=R_1=73.674\,\mathrm{kN}
V2=1P+wu2L22=1(73.674)+0.5474(5)2=38.2055 kNV_2=\frac{1P+w_{u2}L_2}{2}=\frac{1(73.674)+0.5474(5)}{2}=38.2055\,\mathrm{kN}
M2=PL24+wu2L228=73.674(5)4+0.5474(52)8=93.803125 kN mM_2=\frac{PL_2}{4}+\frac{w_{u2}L_2^2}{8}=\frac{73.674(5)}{4}+\frac{0.5474(5^2)}{8}=93.803125\,\mathrm{kN\,m}

Result and concise exam wording — key result lines

V1=R1=wu1L1/2=24.558(6)/2=73.674 kNV_1=R_1=w_{u1}L_1/2=24.558(6)/2=73.674\,\mathrm{kN}
M1=wu1L12/8=24.558(62)/8=110.511 kN mM_1=w_{u1}L_1^2/8=24.558(6^2)/8=110.511\,\mathrm{kN\,m}
wu2=1.4(0.391)=0.5474 kN/m,P=R1=73.674 kNw_{u2}=1.4(0.391)=0.5474\,\mathrm{kN/m},\quad P=R_1=73.674\,\mathrm{kN}
V2=1P+wu2L22=1(73.674)+0.5474(5)2=38.2055 kNV_2=\frac{1P+w_{u2}L_2}{2}=\frac{1(73.674)+0.5474(5)}{2}=38.2055\,\mathrm{kN}
M2=PL24+wu2L228=73.674(5)4+0.5474(52)8=93.803125 kN mM_2=\frac{PL_2}{4}+\frac{w_{u2}L_2^2}{8}=\frac{73.674(5)}{4}+\frac{0.5474(5^2)}{8}=93.803125\,\mathrm{kN\,m}

For B2 use superposition: the B1 point reactions plus B2 self-weight.

Equilibrium divides the symmetric total load equally between the supports.

Section classes [4 marks]

Find which plate buckles first

Before using plastic bending resistance, check whether the flange and web can sustain the required stress distribution.

The short waves are local plate buckling. They differ from sideways movement of the whole member.
The short waves are local plate buckling. They differ from sideways movement of the whole member.

Prediction, then explanation. At fixed width, a thinner plate has a larger width-to-thickness ratio. Local buckling then becomes more restrictive.

Calculate the flange and web ratios separately. Compare each with the limits for its stress condition. The worse class governs.

ε=275/py\varepsilon=\sqrt{275/p_y}

py is the design yield strength in N/mm². ε is a dimensionless scale used in the supplied classification limits.

Scope. Pure bending and uniform compression use different web limits. Class 2 allows plastic resistance but not the Class 1 rotation capability.

Check and takeaway. A Class 1 web and Class 2 flange give a Class 2 section. Do not average the class numbers.

Apply the reasoning to this section’s data and conditions

Source: LectureNotes/CON4334-Data File-20260730.pdf · p.1

S355 design strength depends on the actual flange thickness.

Local classification decides whether plastic bending resistance is allowed.

In pure bending the web limit is different from uniform compression.

py=355 N/mm2,ϵ=275/355=0.880141p_y=355\,\mathrm{N/mm^2},\quad\epsilon=\sqrt{275/355}=0.880141
b/T=6.72,9ϵ=7.921,10ϵ=8.801,13ϵ=11.442b/T=6.72,\quad9\epsilon=7.921,\quad10\epsilon=8.801,\quad13\epsilon=11.442
d/t=34.8<80ϵ=70.411⟹Class 1d/t=34.8<80\epsilon=70.411\quad\Longrightarrow\quad\mathrm{Class}\ 1

Compare the flange class with the web class.

Use the more restrictive class.

Class 1 or 2 permits the capped plastic modulus.

Class 3 uses the elastic modulus.

Source: LectureNotes/CON4334-Data File-20260730.pdf · p.1

S355 design strength depends on the actual flange thickness.

Local classification decides whether plastic bending resistance is allowed.

In pure bending the web limit is different from uniform compression.

py=355 N/mm2,ϵ=275/355=0.880141p_y=355\,\mathrm{N/mm^2},\quad\epsilon=\sqrt{275/355}=0.880141
b/T=5.89,9ϵ=7.921,10ϵ=8.801,13ϵ=11.442b/T=5.89,\quad9\epsilon=7.921,\quad10\epsilon=8.801,\quad13\epsilon=11.442
d/t=47.2<80ϵ=70.411⟹Class 1d/t=47.2<80\epsilon=70.411\quad\Longrightarrow\quad\mathrm{Class}\ 1

Compare the flange class with the web class.

Use the more restrictive class.

Class 1 or 2 permits the capped plastic modulus.

Class 3 uses the elastic modulus.

Result and concise exam wording — key result lines

b/T=6.72,9ϵ=7.921,10ϵ=8.801,13ϵ=11.442b/T=6.72,\quad9\epsilon=7.921,\quad10\epsilon=8.801,\quad13\epsilon=11.442
d/t=34.8<80ϵ=70.411⟹Class 1d/t=34.8<80\epsilon=70.411\quad\Longrightarrow\quad\mathrm{Class}\ 1
py=355 N/mm2,ϵ=275/355=0.880141p_y=355\,\mathrm{N/mm^2},\quad\epsilon=\sqrt{275/355}=0.880141
b/T=5.89,9ϵ=7.921,10ϵ=8.801,13ϵ=11.442b/T=5.89,\quad9\epsilon=7.921,\quad10\epsilon=8.801,\quad13\epsilon=11.442
d/t=47.2<80ϵ=70.411⟹Class 1d/t=47.2<80\epsilon=70.411\quad\Longrightarrow\quad\mathrm{Class}\ 1

Compare the flange class with the web class.

Use the more restrictive class.

Class 1 or 2 permits the capped plastic modulus.

Class 3 uses the elastic modulus.

B1 checks [10 marks]

The web carries the shear check

Compare the applied shear with the resistance of the prescribed shear area.

At the imaginary cut, opposing arrows resist relative sliding. The rolled-UB calculation below assigns the shear area to the web.
At the imaginary cut, opposing arrows resist relative sliding. The rolled-UB calculation below assigns the shear area to the web.

Prediction, then explanation. At fixed design strength and depth, increasing web thickness increases this shear resistance.

Calculate the prescribed shear area. Multiply by the design shear stress from the course rule. Then compare matching force units.

Av=Dt,Vc=pyAv/3A_v=Dt,\qquad V_c=p_yA_v/\sqrt{3}

D is overall depth; t is web thickness, in mm. Av uses mm². py uses N/mm², giving Vc in N.

Scope. Apply this area definition to the stated rolled section. Check web slenderness separately. The factor 0.6 is the low-shear threshold, not this resistance coefficient.

Check and takeaway. A shear pass alone does not prove bending, deflection or local support-web adequacy.

Internal tension and compression resist moment

Find which section resistance applies before comparing it with the moment demand.

In sagging bending, the upper region compresses and the lower region stretches. Together their forces form a resisting couple.
In sagging bending, the upper region compresses and the lower region stretches. Together their forces form a resisting couple.

Prediction, then explanation. A larger appropriate section modulus raises resistance at fixed strength. Local plate buckling can restrict the usable modulus.

Classify the section first. At low shear, use the elastic expression for Class 3 or the prescribed capped plastic expression for Classes 1 and 2.

Mc=min⁡(pyS,1.2pyZ)for Class 1/2 at low shearM_c=\min(p_yS,1.2p_yZ)\quad\text{for Class 1/2 at low shear}

py uses N/mm². S is plastic modulus and Z is elastic modulus, both in mm³. Mc then uses N·mm.

Scope. This is section resistance, not whole-member LTB resistance. High shear and Class 4 require their appropriate treatment.

Check and takeaway. Selecting the larger of the two capped terms defeats the cap. Use their minimum.

A safe beam can still sag too far

Check whether the beam displacement exceeds the permitted service limit.

The straight beam marks the unloaded position. The curved line and vertical arrow show downward displacement, exaggerated for explanation.
The straight beam marks the unloaded position. The curved line and vertical arrow show downward displacement, exaggerated for explanation.

Prediction, then explanation. For the same UDL and stiffness, doubling span multiplies deflection by sixteen. Doubling I halves deflection.

Load bends each beam segment. The curvature accumulates along the span. Material stiffness E and geometric stiffness I resist that deformation.

δmid=5wL4384EI\delta_{mid}=\frac{5wL^4}{384EI}

Use w in N/mm, L in mm, E in N/mm² and I in mm⁴. The resulting midspan deflection is in mm.

Scope. The formula assumes a prismatic, simply supported, linear-elastic beam with full-span UDL. Use the stated service load and deflection limit.

Check and takeaway. A higher yield grade does not automatically increase E. Passing a strength check therefore does not prove acceptable deflection.

Apply the reasoning to this section’s data and conditions

Source: LectureNotes/CON4334-Data File-20260730.pdf · p.2

The following shear model assigns the shear area to the web.

For a rolled UB use Av = Dt, then the course shear resistance pyAv/√3.

The factor 0.6 defines the low-shear threshold below.

The shear-resistance coefficient remains the one in the displayed formula.

Av=256(6.3)=1612.8 mm2A_v=256(6.3)=1612.8\,\mathrm{mm^2}
Vc=pyAv3=355(1612.8)3(1000)=330.558433 kNV_c=\frac{p_yA_v}{\sqrt3}=\frac{355(1612.8)}{\sqrt3(1000)}=330.558433\,\mathrm{kN}
V=73.674 kN,V/Vc=0.222877,0.6Vc=198.33506 kNV=73.674\,\mathrm{kN},\quad V/V_c=0.222877,\quad0.6V_c=198.33506\,\mathrm{kN}

PASS

Mc=min⁡(pySx,1.2pyZx)/1000=min⁡(355(483),1.2(355)(433))/1000=171.465 kN mM_c=\min(p_yS_x,1.2p_yZ_x)/1000=\min(355(483),1.2(355)(433))/1000=171.465\,\mathrm{kN\,m}
M/Mc=110.511/171.465=0.644511M/M_c=110.511/171.465=0.644511

PASS

The maximum shear is below 0.6Vc.

Therefore every section satisfies this low-shear condition.

For serviceability use unfactored imposed load only, E = 205,000 N/mm², I in mm⁴ and span in mm.

Do not include the ULS factors or dead load in this course deflection limit.

δ1=5wQL14384EI1=5(3(2.5))(6000)4384(205000)(5537×104)=11.150046 mm\delta_1=\frac{5w_QL_1^4}{384EI_1}=\frac{5(3(2.5))(6000)^4}{384(205000)(5537\times10^4)}=11.150046\,\mathrm{mm}
δlim=L/360=6000/360=16.666667 mm\delta_{lim}=L/360=6000/360=16.666667\,\mathrm{mm}

PASS

Result and concise exam wording — key result lines

V=73.674 kN,V/Vc=0.222877,0.6Vc=198.33506 kNV=73.674\,\mathrm{kN},\quad V/V_c=0.222877,\quad0.6V_c=198.33506\,\mathrm{kN}
Mc=min⁡(pySx,1.2pyZx)/1000=min⁡(355(483),1.2(355)(433))/1000=171.465 kN mM_c=\min(p_yS_x,1.2p_yZ_x)/1000=\min(355(483),1.2(355)(433))/1000=171.465\,\mathrm{kN\,m}
M/Mc=110.511/171.465=0.644511M/M_c=110.511/171.465=0.644511
δ1=5wQL14384EI1=5(3(2.5))(6000)4384(205000)(5537×104)=11.150046 mm\delta_1=\frac{5w_QL_1^4}{384EI_1}=\frac{5(3(2.5))(6000)^4}{384(205000)(5537\times10^4)}=11.150046\,\mathrm{mm}
δlim=L/360=6000/360=16.666667 mm\delta_{lim}=L/360=6000/360=16.666667\,\mathrm{mm}

PASS

B2 checks [10 marks]

Use the same mechanism: The web carries the shear check. At fixed design strength and depth, increasing web thickness increases this shear resistance.

Use the same mechanism: Internal tension and compression resist moment. A larger appropriate section modulus raises resistance at fixed strength. Local plate buckling can restrict the usable modulus.

Use the same mechanism: A safe beam can still sag too far. For the same UDL and stiffness, doubling span multiplies deflection by sixteen. Doubling I halves deflection.

Apply the reasoning to this section’s data and conditions

Source: LectureNotes/CON4334-Data File-20260730.pdf · p.2

The following shear model assigns the shear area to the web.

For a rolled UB use Av = Dt, then the course shear resistance pyAv/√3.

The factor 0.6 defines the low-shear threshold below.

The shear-resistance coefficient remains the one in the displayed formula.

Av=353.4(6.6)=2332.44 mm2A_v=353.4(6.6)=2332.44\,\mathrm{mm^2}
Vc=pyAv3=355(2332.44)3(1000)=478.055376 kNV_c=\frac{p_yA_v}{\sqrt3}=\frac{355(2332.44)}{\sqrt3(1000)}=478.055376\,\mathrm{kN}
V=38.2055 kN,V/Vc=0.079919,0.6Vc=286.833226 kNV=38.2055\,\mathrm{kN},\quad V/V_c=0.079919,\quad0.6V_c=286.833226\,\mathrm{kN}

PASS

Mc=min⁡(pySx,1.2pyZx)/1000=min⁡(355(659),1.2(355)(576))/1000=233.945 kN mM_c=\min(p_yS_x,1.2p_yZ_x)/1000=\min(355(659),1.2(355)(576))/1000=233.945\,\mathrm{kN\,m}
M/Mc=93.803125/233.945=0.400962M/M_c=93.803125/233.945=0.400962

PASS

The maximum shear is below 0.6Vc.

Therefore every section satisfies this low-shear condition.

For serviceability use unfactored imposed load only, E = 205,000 N/mm², I in mm⁴ and span in mm.

Do not include the ULS factors or dead load in this course deflection limit.

PQ=qkbL1/2=3(2.5)(6)/2=22.5 kNP_Q=q_kbL_1/2=3(2.5)(6)/2=22.5\,\mathrm{kN}
δ2=PQL2348EI2=22.5(1000)(5000)348(205000)(10170×104)=2.810454 mm\delta_2=\frac{P_QL_2^3}{48EI_2}=\frac{22.5(1000)(5000)^3}{48(205000)(10170\times10^4)}=2.810454\,\mathrm{mm}
δlim=L/360=5000/360=13.888889 mm\delta_{lim}=L/360=5000/360=13.888889\,\mathrm{mm}

PASS

Result and concise exam wording — key result lines

Mc=min⁡(pySx,1.2pyZx)/1000=min⁡(355(659),1.2(355)(576))/1000=233.945 kN mM_c=\min(p_yS_x,1.2p_yZ_x)/1000=\min(355(659),1.2(355)(576))/1000=233.945\,\mathrm{kN\,m}
M/Mc=93.803125/233.945=0.400962M/M_c=93.803125/233.945=0.400962
PQ=qkbL1/2=3(2.5)(6)/2=22.5 kNP_Q=q_kbL_1/2=3(2.5)(6)/2=22.5\,\mathrm{kN}
δ2=PQL2348EI2=22.5(1000)(5000)348(205000)(10170×104)=2.810454 mm\delta_2=\frac{P_QL_2^3}{48EI_2}=\frac{22.5(1000)(5000)^3}{48(205000)(10170\times10^4)}=2.810454\,\mathrm{mm}
δlim=L/360=5000/360=13.888889 mm\delta_{lim}=L/360=5000/360=13.888889\,\mathrm{mm}

PASS

Short theory: fire [4 marks]

Delay heat reaching the steel

Identify how the protection surrounds a steel section. Then explain its purpose in a fire.

SolidHollowProfileSteel outline and protection boundary are separate.
Solid casing fills around the section. Hollow casing encloses an air space. Profile protection follows the section outline.

Prediction, then explanation. An insulating layer can slow heating. It does not mean the steel remains at room temperature indefinitely.

Heat changes steel behaviour. Protection delays that change by restricting heat transfer. Show the steel and protection boundaries separately.

The labelled boundaries describe geometry. They do not specify a tested fire-resistance rating.

Scope. Required thickness depends on the system, member and required rating. Do not infer thickness or minutes from a schematic.

Check and takeaway. For a sketch answer, distinguish all three shapes and state that protection delays steel heating.

Apply the reasoning to this section’s data and conditions

Source: LectureNotes/Ch1_Introduction.pdf · p.3
Labelled teaching sketches: sprayed insulation and board encasement.

Labelled teaching sketches: sprayed insulation and board encasement.

Full-size image

  • Sprayed protection: draw a continuous insulating layer following the I-section profile; label steel and protective layer.

    It slows heating and delays strength/stiffness loss.

  • Board encasement: draw a box of fire-resisting boards around the section, including supported joints.

    The enclosure delays heat reaching the steel.

    A fire rating requires a specified tested system.

Result and concise exam wording — key result lines

Source: LectureNotes/Ch1_Introduction.pdf · p.3
Labelled teaching sketches: sprayed insulation and board encasement.

Labelled teaching sketches: sprayed insulation and board encasement.

Full-size image

  • Sprayed protection: draw a continuous insulating layer following the I-section profile; label steel and protective layer.

    It slows heating and delays strength/stiffness loss.

  • Board encasement: draw a box of fire-resisting boards around the section, including supported joints.

    The enclosure delays heat reaching the steel.

    A fire rating requires a specified tested system.

Reusable exam procedure and mistakes

Use the same mechanism: A safe beam can still sag too far. For the same UDL and stiffness, doubling span multiplies deflection by sixteen. Doubling I halves deflection.

Use the same mechanism: Keep load categories separate. Increasing imposed load changes its own term. It does not change the dead-load factor or the steel stiffness.

Use the same mechanism: A table value has conditions. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Apply the reasoning to this section’s data and conditions

  1. Trace the slab arrows and count reactions before doing arithmetic.
  2. Use each member’s exact table row.

    Class 2 is not Class 1.

    However, both allow capped plastic bending.

  3. Never factor an already factored reaction twice; never include beam dead weight in imposed-load deflection.

Explained variant — invented example

Use the same mechanism: A safe beam can still sag too far. For the same UDL and stiffness, doubling span multiplies deflection by sixteen. Doubling I halves deflection.

Ask two separate design questions

Decide whether the check concerns failure or unacceptable behaviour during use.

The strength branch compares demand with resistance. The service branch compares displacement with its specified limit.
The strength branch compares demand with resistance. The service branch compares displacement with its specified limit.

Prediction, then explanation. A larger section may improve both results, but a pass on one branch does not prove a pass on the other.

ULS addresses relevant strength and stability failure modes. SLS addresses specified service conditions such as deflection.

demand≤resistance,δ≤δlimit\text{demand}\le\text{resistance},\qquad\delta\le\delta_{limit}

δ is the calculated displacement; δlimit is the permitted displacement. Both must use the same length unit.

Scope. Use each check’s own load combination and limit. A strength load factor does not change the physical stiffness.

Check and takeaway. Write separate conclusions for strength, stability and serviceability where requested. A single unexplained “safe” hides those distinctions.

Apply the reasoning to this section’s data and conditions

Invented variant: imposed load rises by 20%, with dead load unchanged.

What changes?

Hint

Separate permanent and imposed terms before changing a load.

Explained answer

Multiply imposed-only deflections by 1.2.

Rebuild ULS load as 1.4G + 1.6(1.2Q).

Do not multiply the total ULS action by 1.2.

Section capacities and classes stay unchanged.