Steelwork · Exam learning

2014–2019 · Reference answers

2016-05-11 — connection answers

All answers shown

All connection subparts from this paper, including the specified checks and source qualifications.

Independent teaching answer, not an official solution or marking scheme.

Printed marks are retained.

Read the source conditions beside each result.

Recognise the connection model

Add force components at each bolt

An in-plane load acts away from the bolt-group centre. Find the largest resultant bolt force.

The direct-force arrows are parallel. The moment-force arrows run tangentially around the bolt-group centre.
The direct-force arrows are parallel. The moment-force arrows run tangentially around the bolt-group centre.

Prediction, then explanation. At fixed force, increasing eccentricity increases the moment component. Its direction differs between bolts.

Locate the bolt-group centre and coordinates. Add horizontal components together and vertical components together before finding each resultant.

M=Pe,J=∑(xi2+yi2),FMx=−Myi/J,FMy=Mxi/JM=Pe,\quad J=\sum(x_i^2+y_i^2),\quad F_{Mx}=-My_i/J,\quad F_{My}=Mx_i/J

e, xi and yi use mm; J uses mm². With M in kN·mm, each moment-force component is in kN.

Scope. These expressions use the stated elastic, equal-bolt in-plane model. Out-of-plane tension and prying require another model.

Check and takeaway. Do not add force magnitudes before resolving directions. Two perpendicular forces of 3 and 4 kN give 5 kN, not 7 kN.

An eccentric bracket pulls bolts differently

An out-of-plane moment rotates the bracket about the stated pivot. Determine the bolt tension pattern.

The pivot is the compression reference. Bolts farther from it have longer lever arms in the course elastic model.
The pivot is the compression reference. Bolts farther from it have longer lever arms in the course elastic model.

Prediction, then explanation. For unchanged geometry, doubling the applied moment doubles the modelled bolt tensions. Changing the pivot changes the distribution.

Use compatibility to relate tension to distance. Moment equilibrium then determines the proportionality factor.

Ft,i=Myi∑yj2F_{t,i}=\frac{My_i}{\sum y_j^2}

M is moment in kN·mm. yi is distance from the stated pivot in mm. Ft,i is tension in kN.

Scope. Apply only to the stated active bolt set and pivot model. Flexible plates can create prying; use the supplied assumptions and resistance definitions.

Check and takeaway. A bolt’s lever arm is measured from the pivot used in the equation. It is not automatically its distance from the group centroid.

Test every possible fracture cut

Find the remaining steel area across a candidate tension-failure path.

The dashed fracture line crosses two hole centres. Subtract only the holes crossed by that candidate line.
The dashed fracture line crosses two hole centres. Subtract only the holes crossed by that candidate line.

Prediction, then explanation. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.

Subtract the hole widths crossed by the path, then multiply by thickness. Compare all plausible paths using the applicable course rule.

An=(b−nd0)tA_n=(b-nd_0)t

An is net area in mm²; b is plate width; d₀ is hole diameter; t is thickness, all in mm. n counts holes on this straight path.

Scope. This expression is for a straight cut. Effective area can require further shear-lag rules. Gross, net and effective areas must remain distinct.

Check and takeaway. Use the hole diameter, not the bolt diameter, when removing missing steel. The plate contains a hole, not solid steel around the bolt shank.

Apply the reasoning to this section’s data and conditions

Units: 1 kN = 1,000 N; 1 m = 1,000 mm; 1 cm³ = 1,000 mm³; 1 cm⁴ = 10,000 mm⁴.

Demand is the load effect.

Resistance is the permitted capacity for the selected failure mode.

Compare matching units.

A splice transfers axial force through stages.

A side-plate bracket creates in-plane torsion.

An end-plate bracket creates bolt tension.

Identify which picture applies before selecting a formula.

Bolt shear [3 marks]

Count cuts through each loaded bolt

Find how many shear planes transfer the force through one side of the connection.

The middle plate moves against two cover plates. The two interfaces cut each bolt at two planes.
The middle plate moves against two cover plates. The two interfaces cut each bolt at two planes.

Prediction, then explanation. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Select the area at the actual shear plane. Multiply by bolt shear strength. Count only the bolts and planes in the same transfer stage.

Ps=psAs,Pgroup=nbnsPsP_s=p_sA_s,\qquad P_{group}=n_b n_s P_s

ps is bolt shear strength in N/mm²; As is the appropriate area in mm². nb counts bolts; ns counts equally loaded shear planes.

Scope. Use the thread area when threads cross the plane as required. Check bearing, plate failure and detailing separately.

Check and takeaway. Both halves of a butt splice carry the full transmitted force in sequence. Counting both halves together would double the apparent resistance.

Apply the reasoning to this section’s data and conditions

Given main plate 16 mm, two covers each 10 mm, Grade 8.8 M12 bolts with 14 mm holes.

The transverse dimension chain gives main width 190 mm and cover width 170 mm.

Count 4 bolts on ONE side of the butt.

The other side is in series and does not double the transferable force.

Source: LectureNotes/Ch2_Connection.pdf · p.3, p.4, p.5, p.9, p.10
Source: LectureNotes/CON4334-Data File-20260730.pdf · p.1, p.4

Grade 8.8: shear strength ps = 375, bolt bearing pbb = 1000, ultimate bolt strength Ub = 800 N/mm².

S355 plate: pbs = 550, Us = 510 N/mm², Ke = 1.1.

Use threaded stress area As for the conservative shear plane, nominal d for bearing, and hole diameter d0 for material removed.

Physical interpretation and limits

The force must cross the left bolt group, travel through the covers, then cross the right group.

The weakest stage limits the whole splice, like the weakest link in a chain.

This checks the requested resistance modes.

Check edge preparation and ordinary minimum pitch separately.

A bearing pass alone does not prove all detailing.

Ps,plane=Asps/1000=84.3(375)/1000=31.6125 kNP_{s,plane}=A_sp_s/1000=84.3(375)/1000=31.6125\,\mathrm{kN}
Ps,bolt=2(31.6125)=63.225 kN,Rs=4(2)(31.6125)=252.9 kNP_{s,bolt}=2(31.6125)=63.225\,\mathrm{kN},\quad R_s=4(2)(31.6125)=252.9\,\mathrm{kN}

Each bolt has two shear planes, one at each cover/main interface.

Result and concise exam wording — key result lines

Ps,plane=Asps/1000=84.3(375)/1000=31.6125 kNP_{s,plane}=A_sp_s/1000=84.3(375)/1000=31.6125\,\mathrm{kN}
Ps,bolt=2(31.6125)=63.225 kN,Rs=4(2)(31.6125)=252.9 kNP_{s,bolt}=2(31.6125)=63.225\,\mathrm{kN},\quad R_s=4(2)(31.6125)=252.9\,\mathrm{kN}

Each bolt has two shear planes, one at each cover/main interface.

Bolt bearing [3 marks]

Follow contact pressure into the plate

The bolt may survive shear while the connected plate deforms or tears near the hole.

The labels distinguish bolt diameter d from hole diameter d₀. The arrow at the hole edge shows the bearing contact action.
The labels distinguish bolt diameter d from hole diameter d₀. The arrow at the hole edge shows the bearing contact action.

Prediction, then explanation. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.

Calculate every bound required by the supplied rule. The smallest applicable bound limits the connection at that layer.

Pbearing≤pbsdtP_{bearing}\le p_{bs}dt

pbs is the applicable bearing strength in N/mm²; d is nominal bolt diameter in mm; t is plate thickness in mm.

Scope. This diameter term alone is not the complete check. End-distance and clear-ligament limits, bolt bearing and each connected layer also matter.

Check and takeaway. Two covers and one main plate do not necessarily have the same thickness or strength. Compare the actual force share in each layer.

Apply the reasoning to this section’s data and conditions

tbearing=min⁡(16,2(10))=16 mmt_{bearing}=\min(16,2(10))=16\,\mathrm{mm}
Pbb=dtbearingpbb/1000=12(16)(1000)/1000=192 kN/boltP_{bb}=dt_{bearing}p_{bb}/1000=12(16)(1000)/1000=192\,\mathrm{kN/bolt}
Rbb=4(192)=768 kNR_{bb}=4(192)=768\,\mathrm{kN}

Result and concise exam wording — key result lines

tbearing=min⁡(16,2(10))=16 mmt_{bearing}=\min(16,2(10))=16\,\mathrm{mm}
Pbb=dtbearingpbb/1000=12(16)(1000)/1000=192 kN/boltP_{bb}=dt_{bearing}p_{bb}/1000=12(16)(1000)/1000=192\,\mathrm{kN/bolt}
Rbb=4(192)=768 kNR_{bb}=4(192)=768\,\mathrm{kN}

Plate bearing [5 marks]

Use the same mechanism: Follow contact pressure into the plate. At fixed geometry and strength, a thicker plate raises plate resistance. Moving a hole too near the end can still govern.

Apply the reasoning to this section’s data and conditions

Main plate

Rbs=min⁡(dtpbs,0.5etpbs,1.5lctUs,2dtUb)/1000R_{bs}=\min(dt p_{bs},0.5etp_{bs},1.5l_ctU_s,2dtU_b)/1000
lc=p−d0=70−14=56 mml_c=p-d_0=70-14=56\,\mathrm{mm}
Rbs=min⁡(12(16)(550),0.5(50)(16)(550),1.5(56)(16)(510),2(12)(16)(800))/1000R_{bs}=\min(12(16)(550),0.5(50)(16)(550),1.5(56)(16)(510),2(12)(16)(800))/1000
Rbs=min⁡(105.6,220,685.44,307.2)=105.6 kN/boltR_{bs}=\min(105.6,220,685.44,307.2)=105.6\,\mathrm{kN/bolt}

Each cover plate

Rbs=min⁡(dtpbs,0.5etpbs,1.5lctUs,2dtUb)/1000R_{bs}=\min(dt p_{bs},0.5etp_{bs},1.5l_ctU_s,2dtU_b)/1000
lc=p−d0=70−14=56 mml_c=p-d_0=70-14=56\,\mathrm{mm}
Rbs=min⁡(12(10)(550),0.5(50)(10)(550),1.5(56)(10)(510),2(12)(10)(800))/1000R_{bs}=\min(12(10)(550),0.5(50)(10)(550),1.5(56)(10)(510),2(12)(10)(800))/1000
Rbs=min⁡(66,137.5,428.4,192)=66 kN/boltR_{bs}=\min(66,137.5,428.4,192)=66\,\mathrm{kN/bolt}
Rmain,bearing=4(105.6)=422.4 kN,Rcovers,bearing=2(4)(66)=528 kNR_{main,bearing}=4(105.6)=422.4\,\mathrm{kN},\quad R_{covers,bearing}=2(4)(66)=528\,\mathrm{kN}

Result and concise exam wording — key result lines

Rbs=min⁡(dtpbs,0.5etpbs,1.5lctUs,2dtUb)/1000R_{bs}=\min(dt p_{bs},0.5etp_{bs},1.5l_ctU_s,2dtU_b)/1000
lc=p−d0=70−14=56 mml_c=p-d_0=70-14=56\,\mathrm{mm}
Rbs=min⁡(12(10)(550),0.5(50)(10)(550),1.5(56)(10)(510),2(12)(10)(800))/1000R_{bs}=\min(12(10)(550),0.5(50)(10)(550),1.5(56)(10)(510),2(12)(10)(800))/1000
Rbs=min⁡(66,137.5,428.4,192)=66 kN/boltR_{bs}=\min(66,137.5,428.4,192)=66\,\mathrm{kN/bolt}
Rmain,bearing=4(105.6)=422.4 kN,Rcovers,bearing=2(4)(66)=528 kNR_{main,bearing}=4(105.6)=422.4\,\mathrm{kN},\quad R_{covers,bearing}=2(4)(66)=528\,\mathrm{kN}

Each cover plate

Main plate tension [3 marks]

Use the same mechanism: Test every possible fracture cut. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.

Apply the reasoning to this section’s data and conditions

Main plate, two holes across the critical transverse section.

Ag=bt=190(16)=3040 mm2,An=(b−2d0)t=(190−2(14))(16)=2592 mm2A_g=bt=190(16)=3040\,\mathrm{mm^2},\quad A_n=(b-2d_0)t=(190-2(14))(16)=2592\,\mathrm{mm^2}
Ae=min⁡(Ag,KeAn)=min⁡(3040,1.1(2592))=2851.2 mm2A_e=\min(A_g,K_eA_n)=\min(3040,1.1(2592))=2851.2\,\mathrm{mm^2}
Pt=pyAe/1000=355(2851.2)/1000=1012.176 kNP_t=p_yA_e/1000=355(2851.2)/1000=1012.176\,\mathrm{kN}

Result and concise exam wording — key result lines

Ag=bt=190(16)=3040 mm2,An=(b−2d0)t=(190−2(14))(16)=2592 mm2A_g=bt=190(16)=3040\,\mathrm{mm^2},\quad A_n=(b-2d_0)t=(190-2(14))(16)=2592\,\mathrm{mm^2}
Ae=min⁡(Ag,KeAn)=min⁡(3040,1.1(2592))=2851.2 mm2A_e=\min(A_g,K_eA_n)=\min(3040,1.1(2592))=2851.2\,\mathrm{mm^2}
Pt=pyAe/1000=355(2851.2)/1000=1012.176 kNP_t=p_yA_e/1000=355(2851.2)/1000=1012.176\,\mathrm{kN}

Main plate, two holes across the critical transverse section.

Cover plate tension [3 marks]

Use the same mechanism: Test every possible fracture cut. At fixed plate size, larger holes reduce the straight-path net area. A diagonal path needs its own stagger correction.

Apply the reasoning to this section’s data and conditions

Each cover plate: use its own width and thickness.

Ag=bt=170(10)=1700 mm2,An=(b−2d0)t=(170−2(14))(10)=1420 mm2A_g=bt=170(10)=1700\,\mathrm{mm^2},\quad A_n=(b-2d_0)t=(170-2(14))(10)=1420\,\mathrm{mm^2}
Ae=min⁡(Ag,KeAn)=min⁡(1700,1.1(1420))=1562 mm2A_e=\min(A_g,K_eA_n)=\min(1700,1.1(1420))=1562\,\mathrm{mm^2}
Pt=pyAe/1000=355(1562)/1000=554.51 kNP_t=p_yA_e/1000=355(1562)/1000=554.51\,\mathrm{kN}
Pt,covers=2(554.51)=1109.02 kNP_{t,covers}=2(554.51)=1109.02\,\mathrm{kN}

Result and concise exam wording — key result lines

Ag=bt=170(10)=1700 mm2,An=(b−2d0)t=(170−2(14))(10)=1420 mm2A_g=bt=170(10)=1700\,\mathrm{mm^2},\quad A_n=(b-2d_0)t=(170-2(14))(10)=1420\,\mathrm{mm^2}
Ae=min⁡(Ag,KeAn)=min⁡(1700,1.1(1420))=1562 mm2A_e=\min(A_g,K_eA_n)=\min(1700,1.1(1420))=1562\,\mathrm{mm^2}
Pt=pyAe/1000=355(1562)/1000=554.51 kNP_t=p_yA_e/1000=355(1562)/1000=554.51\,\mathrm{kN}
Pt,covers=2(554.51)=1109.02 kNP_{t,covers}=2(554.51)=1109.02\,\mathrm{kN}

Each cover plate: use its own width and thickness.

Failure mode [1 marks]

Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Apply the reasoning to this section’s data and conditions

Rsplice=min⁡(252.9,768,422.4,528,1012.176,1109.02)=252.9 kNR_{splice}=\min(252.9,768,422.4,528,1012.176,1109.02)=252.9\,\mathrm{kN}
P=300 kN,P/Rsplice=1.18624P=300\,\mathrm{kN},\quad P/R_{splice}=1.18624

FAIL

The governing mode is bolt shear: 300 kN exceeds the four-bolt double-shear group resistance.

Result and concise exam wording — key result lines

Rsplice=min⁡(252.9,768,422.4,528,1012.176,1109.02)=252.9 kNR_{splice}=\min(252.9,768,422.4,528,1012.176,1109.02)=252.9\,\mathrm{kN}
P=300 kN,P/Rsplice=1.18624P=300\,\mathrm{kN},\quad P/R_{splice}=1.18624

The governing mode is bolt shear: 300 kN exceeds the four-bolt double-shear group resistance.

UB bracket welds [12 marks]

A force couple carries moment

Separate the force couple used to carry moment from the force used to carry web shear.

The flange forces act in opposite directions. Their separation z gives the lever arm. The web arrow represents shear.
The flange forces act in opposite directions. Their separation z gives the lever arm. The web arrow represents shear.

Prediction, then explanation. For the same moment, a larger lever arm requires a smaller couple force. It does not remove the web shear.

Moment is force multiplied by perpendicular separation. Divide the required moment by the specified separation to obtain each couple force.

F=M/zF=M/z

M is moment in kN·mm; z is the specified force-line separation in mm; F is force in kN.

Scope. Use the lever arm defined by the source model. Do not silently replace it with overall section depth or another geometric distance.

Check and takeaway. Check flange welds for the couple forces and web welds for the stated shear model. Both force paths need a satisfactory detail.

The weld resists through its throat

Convert a visible fillet leg into resistance per effective length.

The two outer sides are the legs. The shorter perpendicular line through the ideal triangle is the throat.
The two outer sides are the legs. The shorter perpendicular line through the ideal triangle is the throat.

Prediction, then explanation. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

For the course right-angle equal-leg fillet, take throat as 0.7 times leg. Multiply throat area per unit length by weld strength.

a=0.7s,qcap=0.7spw/1000a=0.7s,\qquad q_{cap}=0.7sp_w/1000

s and a are leg and throat in mm. pw is weld strength in N/mm². qcap is resistance in kN/mm.

Scope. Use effective length, the correct steel/electrode strength and permitted leg limits. Full-penetration butt welds use a different model.

Check and takeaway. Illustration: a 6 mm leg at 250 N/mm² gives 0.7(6)(250)/1000=1.05 kN/mm0.7(6)(250)/1000=1.05\,\mathrm{kN/mm}.

A table value has conditions

Find a design property without mixing a row, column or standard from a different case.

The row and column meet at one cell. The table heading supplies the units and the conditions that give the cell meaning.
The row and column meet at one cell. The table heading supplies the units and the conditions that give the cell meaning.

Prediction, then explanation. A different flange thickness can select a lower design strength even when the steel grade name remains unchanged.

Match the complete section designation. Read the relevant axis and unit. For strength tables, select material, thickness and curve before interpolating.

Given values come from the question. Lookup values come from a named table. Assumed values require an explicit condition.

Scope. A missing row or omitted restraint cannot be recovered from a schematic’s scale. Keep the result conditional when required data are absent.

Check and takeaway. Record the table, row, column and unit beside the substitution. That makes a later check possible.

Apply the reasoning to this section’s data and conditions

Source: LectureNotes/Ch2_Connection.pdf · p.31, p.33, p.41
Source: LectureNotes/CON4334-Data File-20260730.pdf · p.9, p.10

Lookup the exact 305 × 127 × 37 UB row.

Read dimensions first, properties second.

D = overall depth; t = web thickness; T = flange thickness; d = clear web depth.

The designation identifies a section-table row.

Read exact dimensions from that row.

D=304.4, t=7.1, T=10.7, d=265.2(mm)D=304.4,\ t=7.1,\ T=10.7,\ d=265.2\quad(\mathrm{mm})
b/T=5.77, d/t=37.4, Ix=7171 cm4, Zx=471 cm3, Sx=539 cm3b/T=5.77,\ d/t=37.4,\ I_x=7171\,\mathrm{cm^4},\ Z_x=471\,\mathrm{cm^3},\ S_x=539\,\mathrm{cm^3}
ry=26.7 mm,u=0.872,x=29.7r_y=26.7\,\mathrm{mm},\quad u=0.872,\quad x=29.7

Follow the specified separated model: the two web welds carry all shear.

The upper and lower flange welds form a force couple carrying moment.

The web-weld length is not the couple arm.

Use the smaller flange-centroid separation D−T conservatively because the exact weld-centroid spacing is not dimensioned.

P=252 kN,M=Pe=252(200)=50400 kN mmP=252\,\mathrm{kN},\quad M=Pe=252(200)=50400\,\mathrm{kN\,mm}
z=D−T=304.4−10.7=293.7 mm,Ff=M/z=50400/293.7=171.603677 kNz=D-T=304.4-10.7=293.7\,\mathrm{mm},\quad F_f=M/z=50400/293.7=171.603677\,\mathrm{kN}
Vw,Rd=2(250−2(6))(0.7)(6)(250)/1000=499.8 kNV_{w,Rd}=2(250-2(6))(0.7)(6)(250)/1000=499.8\,\mathrm{kN}

PASS

Ff,Rd=(120−2(10))(0.7)(10)(250)/1000=175 kNF_{f,Rd}=(120-2(10))(0.7)(10)(250)/1000=175\,\mathrm{kN}

PASS

sweb,max=t−2=7.1−2=5.1 mm,sflange,max=T−2=10.7−2=8.7 mms_{web,max}=t-2=7.1-2=5.1\,\mathrm{mm},\quad s_{flange,max}=T-2=10.7-2=8.7\,\mathrm{mm}

Strength alone passes.

However, the given 6 mm web and 10 mm flange edge welds exceed t−2 and T−2 respectively in the course rule.

The connection cannot be called fully adequate as an ordinary edge-fillet detail.

Result and concise exam wording — key result lines

P=252 kN,M=Pe=252(200)=50400 kN mmP=252\,\mathrm{kN},\quad M=Pe=252(200)=50400\,\mathrm{kN\,mm}
z=D−T=304.4−10.7=293.7 mm,Ff=M/z=50400/293.7=171.603677 kNz=D-T=304.4-10.7=293.7\,\mathrm{mm},\quad F_f=M/z=50400/293.7=171.603677\,\mathrm{kN}
Vw,Rd=2(250−2(6))(0.7)(6)(250)/1000=499.8 kNV_{w,Rd}=2(250-2(6))(0.7)(6)(250)/1000=499.8\,\mathrm{kN}
Ff,Rd=(120−2(10))(0.7)(10)(250)/1000=175 kNF_{f,Rd}=(120-2(10))(0.7)(10)(250)/1000=175\,\mathrm{kN}
sweb,max=t−2=7.1−2=5.1 mm,sflange,max=T−2=10.7−2=8.7 mms_{web,max}=t-2=7.1-2=5.1\,\mathrm{mm},\quad s_{flange,max}=T-2=10.7-2=8.7\,\mathrm{mm}

Strength alone passes.

However, the given 6 mm web and 10 mm flange edge welds exceed t−2 and T−2 respectively in the course rule.

The connection cannot be called fully adequate as an ordinary edge-fillet detail.

Reusable procedure and common errors

Use the same mechanism: Count cuts through each loaded bolt. For equal sharing and unchanged bolt area, two active planes provide twice one plane’s shear resistance.

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Apply the reasoning to this section’s data and conditions

  1. Draw the load-transfer stages.

    Count bolts and shear planes for one stage, then compare all failure modes.

  2. Resolve eccentric forces as vectors.

    Never add perpendicular components arithmetically.

  3. Use effective weld length and check size limits after strength; “strong enough” does not fix an impossible detail.

Explained variant — invented example

Use the same mechanism: The weld resists through its throat. At fixed weld strength, doubling the leg doubles throat and line resistance in this model. Detailing limits can prevent that choice.

Change the ruler, keep the quantity

A section table uses centimetres, but the strength calculation uses millimetres. The numbers must describe the same section.

Length1 factorArea2 factors3 factorsEach centimetre becomes ten millimetres.
In the diagram, the length, square and cube contain one, two and three length factors. Each factor changes when the ruler changes.

Prediction, then explanation. Would every property increase by ten? No. The exponent determines how many factors of ten are needed.

First identify the physical quantity. Next convert each length factor. Keep force and length conversions separate when converting a moment.

1 cmn=10n mmn,1 kN m=106 N mm1\,\mathrm{cm}^n=10^n\,\mathrm{mm}^n,\qquad 1\,\mathrm{kN\,m}=10^6\,\mathrm{N\,mm}

Here n is the length exponent: 2 for area, 3 for section modulus and 4 for second moment of area.

Scope. Changing units changes neither the load nor the section. A conversion factor cannot repair a formula for the wrong physical quantity.

Check and takeaway. Illustration: 2 cm4=20,000 mm42\,\mathrm{cm}^4=20{,}000\,\mathrm{mm}^4. The fourth power belongs to the unit, not the number 2.

Apply the reasoning to this section’s data and conditions

Invented variant: all applied loads are 10% larger but geometry is unchanged.

What scales, and what does not?

Hint

Isolate one load-transfer stage, then distinguish demand from fixed resistance.

Explained answer

For these linear elastic models, bolt forces and weld force per unit length rise 10%; required strength-only weld throat also rises 10%.

Bolt areas, section capacities, effective lengths of already specified welds and detailing limits stay unchanged.

Recheck every utilisation.