2014–2019 · Reference answers
2016-05-11 — beam answers
All independent beam subquestions, including the required sketches and restraint variants.
Independent teaching answer, not an official solution or marking scheme.
Printed marks are retained.
Read the source conditions beside each result.
Read the diagram and choose the checks
A safe beam can still sag too far
Check whether the beam displacement exceeds the permitted service limit.
Prediction, then explanation. For the same UDL and stiffness, doubling span multiplies deflection by sixteen. Doubling I halves deflection.
Load bends each beam segment. The curvature accumulates along the span. Material stiffness E and geometric stiffness I resist that deformation.
Use w in N/mm, L in mm, E in N/mm² and I in mm⁴. The resulting midspan deflection is in mm.
Scope. The formula assumes a prismatic, simply supported, linear-elastic beam with full-span UDL. Use the stated service load and deflection limit.
Check and takeaway. A higher yield grade does not automatically increase E. Passing a strength check therefore does not prove acceptable deflection.
Keep load categories separate
A floor carries permanent material and changing occupancy loads. Find the design load for the stated check.
Prediction, then explanation. Increasing imposed load changes its own term. It does not change the dead-load factor or the steel stiffness.
First convert mass to weight where required. Next collect G and Q in compatible units. Apply the combination specified by the course problem.
G is characteristic dead load; Q is characteristic imposed load. Wu is the design load for this course gravity combination.
Scope. This combination is not universal. Use the specified service load for deflection and the stated factors for other standards or cases.
Check and takeaway. Illustration: G = 10 kN and Q = 5 kN give 22 kN. Factoring their sum by one guessed factor loses the distinction.
Change the ruler, keep the quantity
A section table uses centimetres, but the strength calculation uses millimetres. The numbers must describe the same section.
Prediction, then explanation. Would every property increase by ten? No. The exponent determines how many factors of ten are needed.
First identify the physical quantity. Next convert each length factor. Keep force and length conversions separate when converting a moment.
Here n is the length exponent: 2 for area, 3 for section modulus and 4 for second moment of area.
Scope. Changing units changes neither the load nor the section. A conversion factor cannot repair a formula for the wrong physical quantity.
Check and takeaway. Illustration: . The fourth power belongs to the unit, not the number 2.
Apply the reasoning to this section’s data and conditions
Units: 1 kN = 1,000 N; 1 m = 1,000 mm; 1 cm³ = 1,000 mm³; 1 cm⁴ = 10,000 mm⁴.
Demand is the load effect.
Resistance is the permitted capacity for the selected failure mode.
Compare matching units.
The member is 406 × 178 × 74 UB, S355, simply supported over 5.5 m, with compression-flange restraints at its ends.
Read M and V as ultimate design actions; Q is the unfactored imposed load for deflection.
Do not factor a given design moment again.
Lookup the exact 406 × 178 × 74 UB row.
Read dimensions first, properties second.
D = overall depth; t = web thickness; T = flange thickness; d = clear web depth.
The designation identifies a section-table row.
Read exact dimensions from that row.
Two ULS and two SLS examples [4 marks]
Ask two separate design questions
Decide whether the check concerns failure or unacceptable behaviour during use.
Prediction, then explanation. A larger section may improve both results, but a pass on one branch does not prove a pass on the other.
ULS addresses relevant strength and stability failure modes. SLS addresses specified service conditions such as deflection.
δ is the calculated displacement; δlimit is the permitted displacement. Both must use the same length unit.
Scope. Use each check’s own load combination and limit. A strength load factor does not change the physical stiffness.
Check and takeaway. Write separate conclusions for strength, stability and serviceability where requested. A single unexplained “safe” hides those distinctions.
Apply the reasoning to this section’s data and conditions
- ULS — strength: shear yielding, bending failure or connection failure can prevent the structure carrying the design load.
- ULS — stability: member buckling or overall loss of equilibrium can cause collapse.
- SLS — deflection: excessive movement can damage finishes or stop doors/services working even before collapse.
- SLS — vibration: excessive response causes discomfort or interferes with use.
Give two examples from each category; ULS concerns load-carrying safety, SLS concerns acceptable use.
Result and concise exam wording — key result lines
- ULS — strength: shear yielding, bending failure or connection failure can prevent the structure carrying the design load.
- ULS — stability: member buckling or overall loss of equilibrium can cause collapse.
- SLS — deflection: excessive movement can damage finishes or stop doors/services working even before collapse.
- SLS — vibration: excessive response causes discomfort or interferes with use.
Give two examples from each category; ULS concerns load-carrying safety, SLS concerns acceptable use.
Ultimate actions [6 marks]
Balance the isolated beam
Find the two vertical reactions before calculating internal shear or moment.
Prediction, then explanation. Move the same load toward B. Reaction B increases because the load has a larger moment arm about A.
Take moments about A. Reaction A has zero lever arm there. Then use vertical force balance to find reaction A.
P, RA and RB are forces in kN. L is support spacing and a is load position, both in m.
Scope. These expressions describe one point load on a simply supported beam. Add other loads through equilibrium; keep their actual positions.
Check and takeaway. Illustration: P = 60 kN, L = 6 m and a = 2 m give RB = 20 kN and RA = 40 kN.
Vertical bending can trigger sideways motion
A beam has enough local bending resistance. Check whether its compression flange can move sideways and twist.
Prediction, then explanation. Adding a valid lateral restraint shortens a stability segment. It need not change the beam’s vertical reaction or moment diagram.
Identify the compressed flange and effective restraints. Calculate the specified slenderness, read buckling strength and compare resistance with the segment demand.
LE and ry use the same length unit. pb uses N/mm²; Sx uses mm³; Mb uses N·mm. mLT is dimensionless.
Scope. Use the specified section class, effective-length branch and loading condition. Load height alone does not prove a destabilizing case.
Check and takeaway. Removing a lateral restraint requires a new segment stability check. The old shorter-segment result cannot establish the longer segment’s adequacy.
Apply the reasoning to this section’s data and conditions
Use g = 9.81 m/s², the numerical convention printed in this paper’s AQ1.
Add the section’s own weight once to the 10 kN/m dead load.
Result and concise exam wording — key result lines
Use g = 9.81 m/s², the numerical convention printed in this paper’s AQ1.
Add the section’s own weight once to the 10 kN/m dead load.
Section classification [2 marks]
Find which plate buckles first
Before using plastic bending resistance, check whether the flange and web can sustain the required stress distribution.
Prediction, then explanation. At fixed width, a thinner plate has a larger width-to-thickness ratio. Local buckling then becomes more restrictive.
Calculate the flange and web ratios separately. Compare each with the limits for its stress condition. The worse class governs.
py is the design yield strength in N/mm². ε is a dimensionless scale used in the supplied classification limits.
Scope. Pure bending and uniform compression use different web limits. Class 2 allows plastic resistance but not the Class 1 rotation capability.
Check and takeaway. A Class 1 web and Class 2 flange give a Class 2 section. Do not average the class numbers.
Apply the reasoning to this section’s data and conditions
S355 design strength depends on the actual flange thickness.
Local classification decides whether plastic bending resistance is allowed.
In pure bending the web limit is different from uniform compression.
Compare the flange class with the web class.
Use the more restrictive class.
Class 1 or 2 permits the capped plastic modulus.
Class 3 uses the elastic modulus.
Result and concise exam wording — key result lines
Compare the flange class with the web class.
Use the more restrictive class.
Class 1 or 2 permits the capped plastic modulus.
Class 3 uses the elastic modulus.
Shear and section resistance [3 marks]
The web carries the shear check
Compare the applied shear with the resistance of the prescribed shear area.
Prediction, then explanation. At fixed design strength and depth, increasing web thickness increases this shear resistance.
Calculate the prescribed shear area. Multiply by the design shear stress from the course rule. Then compare matching force units.
D is overall depth; t is web thickness, in mm. Av uses mm². py uses N/mm², giving Vc in N.
Scope. Apply this area definition to the stated rolled section. Check web slenderness separately. The factor 0.6 is the low-shear threshold, not this resistance coefficient.
Check and takeaway. A shear pass alone does not prove bending, deflection or local support-web adequacy.
Internal tension and compression resist moment
Find which section resistance applies before comparing it with the moment demand.
Prediction, then explanation. A larger appropriate section modulus raises resistance at fixed strength. Local plate buckling can restrict the usable modulus.
Classify the section first. At low shear, use the elastic expression for Class 3 or the prescribed capped plastic expression for Classes 1 and 2.
py uses N/mm². S is plastic modulus and Z is elastic modulus, both in mm³. Mc then uses N·mm.
Scope. This is section resistance, not whole-member LTB resistance. High shear and Class 4 require their appropriate treatment.
Check and takeaway. Selecting the larger of the two capped terms defeats the cap. Use their minimum.
Apply the reasoning to this section’s data and conditions
The following shear model assigns the shear area to the web.
For a rolled UB use Av = Dt, then the course shear resistance pyAv/√3.
The factor 0.6 defines the low-shear threshold below.
The shear-resistance coefficient remains the one in the displayed formula.
PASS
PASS
The maximum shear is below 0.6Vc.
Therefore every section satisfies this low-shear condition.
Result and concise exam wording — key result lines
The maximum shear is below 0.6Vc.
Therefore every section satisfies this low-shear condition.
Lateral-torsional buckling [12 marks]
Use the same mechanism: Vertical bending can trigger sideways motion. Adding a valid lateral restraint shortens a stability segment. It need not change the beam’s vertical reaction or moment diagram.
Apply the reasoning to this section’s data and conditions
First locate the quarter, half and three-quarter points of this restraint segment.
Read the moment magnitude at each point.
Divide each magnitude by the largest moment magnitude anywhere in that segment.
The stations belong to the segment, not necessarily to the whole beam.
Apply the lower bound 0.44.
Use the stated normal-loading effective-length branch: LE equals the distance between effective lateral/torsional restraints.
A lateral restraint changes the stability model.
Add a vertical support only if the detail actually provides one.
Class 1/2 gives βW = 1.
Table 8.3, py = 355 N/mm² column; bracketing λLT rows 95 and 100.
Interpolate in this column only.
PASS
Result and concise exam wording — key result lines
PASS
Imposed-load deflection [3 marks]
Use the same mechanism: A safe beam can still sag too far. For the same UDL and stiffness, doubling span multiplies deflection by sixteen. Doubling I halves deflection.
Apply the reasoning to this section’s data and conditions
Use imposed load only: 3 kN/m over the whole span.
E = 205,000 N/mm².
Convert I from cm⁴ to mm⁴ by multiplying by 10,000.
Use span in mm. 1 kN/m is numerically 1 N/mm.
PASS
Result and concise exam wording — key result lines
PASS
Reusable procedure and traps
Moment shape matters within one segment
Represent a nonuniform moment distribution in the applicable member-buckling equation.
Prediction, then explanation. Two segments can have equal peak moment but different distributions. Their equivalent moment factors can therefore differ.
Evaluate moments from the true whole-beam analysis at the required positions. Apply the exact table’s weights, signs and lower bound.
mLT is an LTB factor. mx and my belong to the specified flexural checks. They are not interchangeable.
Scope. Some rules use magnitudes; others require signed ordinates. A factor does not reduce the actual moment used in a local section check.
Check and takeaway. Measure quarter points from the segment start, not automatically from the beam’s left support.
Use the same mechanism: A safe beam can still sag too far. For the same UDL and stiffness, doubling span multiplies deflection by sixteen. Doubling I halves deflection.
Use the same mechanism: Vertical bending can trigger sideways motion. Adding a valid lateral restraint shortens a stability segment. It need not change the beam’s vertical reaction or moment diagram.
Apply the reasoning to this section’s data and conditions
Separate ultimate resistance from imposed-load serviceability.
Keep kN/m and mm-based formulas consistent.
Establish the whole-beam reactions first.
For each restraint segment use its own length, quarter-point moments and maximum moment.
A high Mc does not prove LTB passes.
Check mLT M ≤ Mb as well as the applicable section resistance.
A smaller unrestrained length normally increases Mb.
However, its moment factor changes too.
Recalculate rather than scaling the old ratio.
Explained variant — invented example
Use the same mechanism: A safe beam can still sag too far. For the same UDL and stiffness, doubling span multiplies deflection by sixteen. Doubling I halves deflection.
Use the same mechanism: Vertical bending can trigger sideways motion. Adding a valid lateral restraint shortens a stability segment. It need not change the beam’s vertical reaction or moment diagram.
A force couple carries moment
Separate the force couple used to carry moment from the force used to carry web shear.
Prediction, then explanation. For the same moment, a larger lever arm requires a smaller couple force. It does not remove the web shear.
Moment is force multiplied by perpendicular separation. Divide the required moment by the specified separation to obtain each couple force.
M is moment in kN·mm; z is the specified force-line separation in mm; F is force in kN.
Scope. Use the lever arm defined by the source model. Do not silently replace it with overall section depth or another geometric distance.
Check and takeaway. Check flange welds for the couple forces and web welds for the stated shear model. Both force paths need a satisfactory detail.
Apply the reasoning to this section’s data and conditions
Invented variant: add a lateral brace at a quarter-span point without changing vertical supports or loads.
Which calculations change?
Hint
Separate the vertical-load model from the lateral-restraint model.
Explained answer
Reactions, SFD, BMD and vertical-load deflection remain unchanged in this ideal restraint model.
Create new LTB segments, then recalculate each LE, quarter-station moments, mLT, λLT, pb and utilisation.
The brace needs a stable load path and cannot be treated as a new vertical support.