All connection subparts from this paper, including the specified checks and source qualifications.
Independent teaching answer, not an official solution or marking scheme. Printed marks are retained. Read the source conditions beside each result.
Recognise the connection model
Units: 1 kN = 1,000 N; 1 m = 1,000 mm; 1 cm³ = 1,000 mm³; 1 cm⁴ = 10,000 mm⁴. A demand is the load effect; a resistance is what the member can carry. Compare matching units.
A splice transfers axial force through stages. A side-plate bracket creates in-plane torsion. An end-plate bracket creates bolt tension. Identify which picture applies before selecting a formula.
Bolt shear [3 marks]
Given main plate 16 mm, two covers each 10 mm, Grade 8.8 M12 bolts with 14 mm holes. The transverse dimension chain gives main width 190 mm and cover width 170 mm. Count 4 bolts on ONE side of the butt. The other side is in series and does not double the transferable force.
Grade 8.8: shear strength ps = 375, bolt bearing pbb = 1000, ultimate bolt strength Ub = 800 N/mm². S355 plate: pbs = 550, Us = 510 N/mm², Ke = 1.1. Use threaded stress area As for the conservative shear plane, nominal d for bearing, and hole diameter d0 for material removed.
Simple explanation — open only if needed
The force must cross the left bolt group, travel through the covers, then cross the right group. The weakest stage limits the whole splice, like the weakest link in a chain.
This checks the requested resistance modes. Check edge preparation and ordinary minimum pitch separately; a bearing pass alone does not prove all detailing.
Lookup the exact 305 × 127 × 37 UB row. Read dimensions first, properties second. D = overall depth; t = web thickness; T = flange thickness; d = clear web depth. The designation is not an exact dimension.
Follow the specified separated model: the two web welds carry all shear; the upper and lower flange welds form a force couple carrying moment. The web-weld length is not the couple arm. Use the smaller flange-centroid separation D−T conservatively because the exact weld-centroid spacing is not dimensioned.
Strength alone passes, but the given 6 mm web and 10 mm flange edge welds exceed t−2 and T−2 respectively in the course rule. The connection cannot be called fully adequate as an ordinary edge-fillet detail.
Strength alone passes, but the given 6 mm web and 10 mm flange edge welds exceed t−2 and T−2 respectively in the course rule. The connection cannot be called fully adequate as an ordinary edge-fillet detail.
Reusable procedure and common errors
Draw the load-transfer stages. Count bolts and shear planes for one stage, then compare all failure modes.
Resolve eccentric forces as vectors. Never add perpendicular components arithmetically.
Use effective weld length and check size limits after strength; “strong enough” does not fix an impossible detail.
Independent practice — invented variant
Invented variant: all applied loads are 10% larger but geometry is unchanged. What scales, and what does not?
Hint
Isolate one load-transfer stage, then distinguish demand from fixed resistance.
Reveal answer
For these linear elastic models, bolt forces and weld force per unit length rise 10%; required strength-only weld throat also rises 10%. Bolt areas, section capacities, effective lengths of already specified welds and detailing limits stay unchanged. Recheck every utilisation.