Steelwork · Exam learning

2014–2019 · Reference answers

2016-01-08 — floor and foundations

Solve the complete compulsory question, using the original diagram beside the calculation.

Independent teaching answer, not an official solution or marking scheme. Printed marks are retained. Read the source conditions beside each result.

Read the load path first

The slab arrows point across adjacent B1 beams. Each interior B1 collects half the 3 m bay on either side: tributary width 3 m. Its labelled span is 7 m. The supporting B2 spans 9 m between the drawn columns and receives 2 B1 end reaction(s), at one-third and two-thirds of its span.

Beams aligned directly with a column deliver their end reaction to that column, not as an extra midspan load on B2. The B2 point load is already factored; do not factor it again. The slab gives full compression-flange restraint, so this is section resistance rather than an LTB design.

Units: 1 kN = 1,000 N; 1 m = 1,000 mm; 1 cm³ = 1,000 mm³; 1 cm⁴ = 10,000 mm⁴. A demand is the load effect; a resistance is what the member can carry. Compare matching units.

Simple explanation — open only if needed

Think of a tray resting on small bars, then on two larger edge bars. Follow where each bar ends: that determines which reaction goes onto the next bar.

Load intensity [4 marks]

Given slab thickness 140 mm, finishes 0.5 kN/m², imposed load 4.5 kN/m². Convert thickness to metres. Permanent area load includes concrete and finishes; beam weight is added later as a line load.

gk=hγc+gfin=0.14(24.5)+0.5=3.93 kN/m2g_k=h\gamma_c+g_{fin}=0.14(24.5)+0.5=3.93\,\mathrm{kN/m^2}
qu=1.4gk+1.6qk=1.4(3.93)+1.6(4.5)=12.702 kN/m2q_u=1.4g_k+1.6q_k=1.4(3.93)+1.6(4.5)=12.702\,\mathrm{kN/m^2}
Compact exam answer — key result lines
gk=hγc+gfin=0.14(24.5)+0.5=3.93 kN/m2g_k=h\gamma_c+g_{fin}=0.14(24.5)+0.5=3.93\,\mathrm{kN/m^2}
qu=1.4gk+1.6qk=1.4(3.93)+1.6(4.5)=12.702 kN/m2q_u=1.4g_k+1.6q_k=1.4(3.93)+1.6(4.5)=12.702\,\mathrm{kN/m^2}

Given slab thickness 140 mm, finishes 0.5 kN/m², imposed load 4.5 kN/m². Convert thickness to metres. Permanent area load includes concrete and finishes; beam weight is added later as a line load.

Beam actions [8 marks]

Source: LectureNotes/CON4334-Data File-20260730.pdf · p.9, p.10

Lookup the exact 406 × 140 × 46 UB row. Read dimensions first, properties second. D = overall depth; t = web thickness; T = flange thickness; d = clear web depth. The designation is not an exact dimension.

D=403.2, t=6.8, T=11.2, d=360.4(mm)D=403.2,\ t=6.8,\ T=11.2,\ d=360.4\quad(\mathrm{mm})
b/T=6.35, d/t=53, Ix=15690 cm4, Zx=778 cm3, Sx=888 cm3b/T=6.35,\ d/t=53,\ I_x=15690\,\mathrm{cm^4},\ Z_x=778\,\mathrm{cm^3},\ S_x=888\,\mathrm{cm^3}
ry=30.3 mm,u=0.871,x=38.9r_y=30.3\,\mathrm{mm},\quad u=0.871,\quad x=38.9
Source: Pastpaper/22ENGTY033.pdf · p.18, p.19

Lookup the exact 610 × 305 × 149 UB row. Read dimensions first, properties second. D = overall depth; t = web thickness; T = flange thickness; d = clear web depth. The designation is not an exact dimension.

D=612.4, t=11.8, T=19.7, d=540(mm)D=612.4,\ t=11.8,\ T=19.7,\ d=540\quad(\mathrm{mm})
b/T=7.74, d/t=45.8, Ix=125900 cm4, Zx=4111 cm3, Sx=4594 cm3b/T=7.74,\ d/t=45.8,\ I_x=125900\,\mathrm{cm^4},\ Z_x=4111\,\mathrm{cm^3},\ S_x=4594\,\mathrm{cm^3}
ry=70 mm,u=0.886,x=32.7r_y=70\,\mathrm{mm},\quad u=0.886,\quad x=32.7

Lookup mass in kg/m and multiply by g/1000 to get kN/m. Multiply the slab area load by the tributary width, not by the full slab area.

wg1=46(10)/1000=0.46,wg2=149.2(10)/1000=1.492(kN/m)w_{g1}=46(10)/1000=0.46,\quad w_{g2}=149.2(10)/1000=1.492\quad(\mathrm{kN/m})
wu1=qub+1.4wg1=12.702(3)+1.4(0.46)=38.75 kN/mw_{u1}=q_ub+1.4w_{g1}=12.702(3)+1.4(0.46)=38.75\,\mathrm{kN/m}
V1=R1=wu1L1/2=38.75(7)/2=135.625 kNV_1=R_1=w_{u1}L_1/2=38.75(7)/2=135.625\,\mathrm{kN}
M1=wu1L12/8=38.75(72)/8=237.34375 kN mM_1=w_{u1}L_1^2/8=38.75(7^2)/8=237.34375\,\mathrm{kN\,m}

For B2 use superposition: the B1 point reactions plus B2 self-weight. Equilibrium divides the symmetric total load equally between the supports.

wu2=1.4(1.492)=2.0888 kN/m,P=R1=135.625 kNw_{u2}=1.4(1.492)=2.0888\,\mathrm{kN/m},\quad P=R_1=135.625\,\mathrm{kN}
V2=2P+wu2L22=2(135.625)+2.0888(9)2=145.0246 kNV_2=\frac{2P+w_{u2}L_2}{2}=\frac{2(135.625)+2.0888(9)}{2}=145.0246\,\mathrm{kN}
M2=PL23+wu2L228=135.625(9)3+2.0888(92)8=428.0241 kN mM_2=\frac{PL_2}{3}+\frac{w_{u2}L_2^2}{8}=\frac{135.625(9)}{3}+\frac{2.0888(9^2)}{8}=428.0241\,\mathrm{kN\,m}
Compact exam answer — key result lines
V1=R1=wu1L1/2=38.75(7)/2=135.625 kNV_1=R_1=w_{u1}L_1/2=38.75(7)/2=135.625\,\mathrm{kN}
M1=wu1L12/8=38.75(72)/8=237.34375 kN mM_1=w_{u1}L_1^2/8=38.75(7^2)/8=237.34375\,\mathrm{kN\,m}
wu2=1.4(1.492)=2.0888 kN/m,P=R1=135.625 kNw_{u2}=1.4(1.492)=2.0888\,\mathrm{kN/m},\quad P=R_1=135.625\,\mathrm{kN}
V2=2P+wu2L22=2(135.625)+2.0888(9)2=145.0246 kNV_2=\frac{2P+w_{u2}L_2}{2}=\frac{2(135.625)+2.0888(9)}{2}=145.0246\,\mathrm{kN}
M2=PL23+wu2L228=135.625(9)3+2.0888(92)8=428.0241 kN mM_2=\frac{PL_2}{3}+\frac{w_{u2}L_2^2}{8}=\frac{135.625(9)}{3}+\frac{2.0888(9^2)}{8}=428.0241\,\mathrm{kN\,m}

For B2 use superposition: the B1 point reactions plus B2 self-weight. Equilibrium divides the symmetric total load equally between the supports.

Section classes [4 marks]

Source: LectureNotes/CON4334-Data File-20260730.pdf · p.1

S355 design strength depends on the actual flange thickness. Local classification decides whether plastic bending resistance is allowed. In pure bending the web limit is different from uniform compression.

py=355 N/mm2,ϵ=275/355=0.880141p_y=355\,\mathrm{N/mm^2},\quad\epsilon=\sqrt{275/355}=0.880141
b/T=6.35,9ϵ=7.921,10ϵ=8.801,13ϵ=11.442b/T=6.35,\quad9\epsilon=7.921,\quad10\epsilon=8.801,\quad13\epsilon=11.442
d/t=53<80ϵ=70.411⟹Class 1d/t=53<80\epsilon=70.411\quad\Longrightarrow\quad\mathrm{Class}\ 1

Take the worse flange/web class. Class 1 or 2 permits the capped plastic modulus; Class 3 uses the elastic modulus.

Source: LectureNotes/CON4334-Data File-20260730.pdf · p.1

S355 design strength depends on the actual flange thickness. Local classification decides whether plastic bending resistance is allowed. In pure bending the web limit is different from uniform compression.

py=345 N/mm2,ϵ=275/345=0.892805p_y=345\,\mathrm{N/mm^2},\quad\epsilon=\sqrt{275/345}=0.892805
b/T=7.74,9ϵ=8.035,10ϵ=8.928,13ϵ=11.606b/T=7.74,\quad9\epsilon=8.035,\quad10\epsilon=8.928,\quad13\epsilon=11.606
d/t=45.8<80ϵ=71.424⟹Class 1d/t=45.8<80\epsilon=71.424\quad\Longrightarrow\quad\mathrm{Class}\ 1

Take the worse flange/web class. Class 1 or 2 permits the capped plastic modulus; Class 3 uses the elastic modulus.

Compact exam answer — key result lines
b/T=6.35,9ϵ=7.921,10ϵ=8.801,13ϵ=11.442b/T=6.35,\quad9\epsilon=7.921,\quad10\epsilon=8.801,\quad13\epsilon=11.442
d/t=53<80ϵ=70.411⟹Class 1d/t=53<80\epsilon=70.411\quad\Longrightarrow\quad\mathrm{Class}\ 1
py=345 N/mm2,ϵ=275/345=0.892805p_y=345\,\mathrm{N/mm^2},\quad\epsilon=\sqrt{275/345}=0.892805
b/T=7.74,9ϵ=8.035,10ϵ=8.928,13ϵ=11.606b/T=7.74,\quad9\epsilon=8.035,\quad10\epsilon=8.928,\quad13\epsilon=11.606
d/t=45.8<80ϵ=71.424⟹Class 1d/t=45.8<80\epsilon=71.424\quad\Longrightarrow\quad\mathrm{Class}\ 1

Take the worse flange/web class. Class 1 or 2 permits the capped plastic modulus; Class 3 uses the elastic modulus.

B1 checks [10 marks]

Source: LectureNotes/CON4334-Data File-20260730.pdf · p.2

The web carries shear. For a rolled UB use Av = Dt, then the course shear resistance pyAv/√3. The 0.6 factor below is the low-shear threshold; it is not the coefficient in the shear-resistance formula.

Av=403.2(6.8)=2741.76 mm2A_v=403.2(6.8)=2741.76\,\mathrm{mm^2}
Vc=pyAv3=355(2741.76)3(1000)=561.949335 kNV_c=\frac{p_yA_v}{\sqrt3}=\frac{355(2741.76)}{\sqrt3(1000)}=561.949335\,\mathrm{kN}
V=135.625 kN,V/Vc=0.241347,0.6Vc=337.169601 kNV=135.625\,\mathrm{kN},\quad V/V_c=0.241347,\quad0.6V_c=337.169601\,\mathrm{kN}

PASS

Mc=min⁡(pySx,1.2pyZx)/1000=min⁡(355(888),1.2(355)(778))/1000=315.24 kN mM_c=\min(p_yS_x,1.2p_yZ_x)/1000=\min(355(888),1.2(355)(778))/1000=315.24\,\mathrm{kN\,m}
M/Mc=237.34375/315.24=0.752899M/M_c=237.34375/315.24=0.752899

PASS

Even the maximum shear is below 0.6Vc, so the low-shear moment resistance applies throughout.

For serviceability use unfactored imposed load only, E = 205,000 N/mm², I in mm⁴ and span in mm. Do not include the ULS factors or dead load in this course deflection limit.

δ1=5wQL14384EI1=5(4.5(3))(7000)4384(205000)(15690×104)=13.121634 mm\delta_1=\frac{5w_QL_1^4}{384EI_1}=\frac{5(4.5(3))(7000)^4}{384(205000)(15690\times10^4)}=13.121634\,\mathrm{mm}
δlim=L/360=7000/360=19.444444 mm\delta_{lim}=L/360=7000/360=19.444444\,\mathrm{mm}

PASS

Compact exam answer — key result lines
V=135.625 kN,V/Vc=0.241347,0.6Vc=337.169601 kNV=135.625\,\mathrm{kN},\quad V/V_c=0.241347,\quad0.6V_c=337.169601\,\mathrm{kN}
Mc=min⁡(pySx,1.2pyZx)/1000=min⁡(355(888),1.2(355)(778))/1000=315.24 kN mM_c=\min(p_yS_x,1.2p_yZ_x)/1000=\min(355(888),1.2(355)(778))/1000=315.24\,\mathrm{kN\,m}
M/Mc=237.34375/315.24=0.752899M/M_c=237.34375/315.24=0.752899
δ1=5wQL14384EI1=5(4.5(3))(7000)4384(205000)(15690×104)=13.121634 mm\delta_1=\frac{5w_QL_1^4}{384EI_1}=\frac{5(4.5(3))(7000)^4}{384(205000)(15690\times10^4)}=13.121634\,\mathrm{mm}
δlim=L/360=7000/360=19.444444 mm\delta_{lim}=L/360=7000/360=19.444444\,\mathrm{mm}

PASS

B2 checks [10 marks]

Source: LectureNotes/CON4334-Data File-20260730.pdf · p.2

The web carries shear. For a rolled UB use Av = Dt, then the course shear resistance pyAv/√3. The 0.6 factor below is the low-shear threshold; it is not the coefficient in the shear-resistance formula.

Av=612.4(11.8)=7226.32 mm2A_v=612.4(11.8)=7226.32\,\mathrm{mm^2}
Vc=pyAv3=345(7226.32)3(1000)=1439.38064 kNV_c=\frac{p_yA_v}{\sqrt3}=\frac{345(7226.32)}{\sqrt3(1000)}=1439.38064\,\mathrm{kN}
V=145.0246 kN,V/Vc=0.100755,0.6Vc=863.628384 kNV=145.0246\,\mathrm{kN},\quad V/V_c=0.100755,\quad0.6V_c=863.628384\,\mathrm{kN}

PASS

Mc=min⁡(pySx,1.2pyZx)/1000=min⁡(345(4594),1.2(345)(4111))/1000=1584.93 kN mM_c=\min(p_yS_x,1.2p_yZ_x)/1000=\min(345(4594),1.2(345)(4111))/1000=1584.93\,\mathrm{kN\,m}
M/Mc=428.0241/1584.93=0.270059M/M_c=428.0241/1584.93=0.270059

PASS

Even the maximum shear is below 0.6Vc, so the low-shear moment resistance applies throughout.

For serviceability use unfactored imposed load only, E = 205,000 N/mm², I in mm⁴ and span in mm. Do not include the ULS factors or dead load in this course deflection limit.

PQ=qkbL1/2=4.5(3)(7)/2=47.25 kNP_Q=q_kbL_1/2=4.5(3)(7)/2=47.25\,\mathrm{kN}
δ2=23PQL23648EI2=23(47.25)(1000)(9000)3648(205000)(125900×104)=4.736991 mm\delta_2=\frac{23P_QL_2^3}{648EI_2}=\frac{23(47.25)(1000)(9000)^3}{648(205000)(125900\times10^4)}=4.736991\,\mathrm{mm}

Here P is each of the two equal third-point loads, not their sum. Setting a/L = 1/3 in the symmetric two-load formula gives 23/648.

δlim=L/360=9000/360=25 mm\delta_{lim}=L/360=9000/360=25\,\mathrm{mm}

PASS

Compact exam answer — key result lines
Mc=min⁡(pySx,1.2pyZx)/1000=min⁡(345(4594),1.2(345)(4111))/1000=1584.93 kN mM_c=\min(p_yS_x,1.2p_yZ_x)/1000=\min(345(4594),1.2(345)(4111))/1000=1584.93\,\mathrm{kN\,m}
M/Mc=428.0241/1584.93=0.270059M/M_c=428.0241/1584.93=0.270059
PQ=qkbL1/2=4.5(3)(7)/2=47.25 kNP_Q=q_kbL_1/2=4.5(3)(7)/2=47.25\,\mathrm{kN}
δ2=23PQL23648EI2=23(47.25)(1000)(9000)3648(205000)(125900×104)=4.736991 mm\delta_2=\frac{23P_QL_2^3}{648EI_2}=\frac{23(47.25)(1000)(9000)^3}{648(205000)(125900\times10^4)}=4.736991\,\mathrm{mm}
δlim=L/360=9000/360=25 mm\delta_{lim}=L/360=9000/360=25\,\mathrm{mm}

PASS

Short theory: fire [4 marks]

Source: LectureNotes/Ch1_Introduction.pdf · p.3
Labelled teaching sketches: sprayed insulation and board encasement.
Labelled teaching sketches: sprayed insulation and board encasement. Full-size image
  • Sprayed protection: draw a continuous insulating layer following the I-section profile; label steel and protective layer. It slows heating and delays strength/stiffness loss.
  • Board encasement: draw a box of fire-resisting boards around the section, including supported joints. The enclosure delays heat reaching the steel. A fire rating requires a specified tested system.
Compact exam answer — key result lines
Source: LectureNotes/Ch1_Introduction.pdf · p.3
Labelled teaching sketches: sprayed insulation and board encasement.
Labelled teaching sketches: sprayed insulation and board encasement. Full-size image
  • Sprayed protection: draw a continuous insulating layer following the I-section profile; label steel and protective layer. It slows heating and delays strength/stiffness loss.
  • Board encasement: draw a box of fire-resisting boards around the section, including supported joints. The enclosure delays heat reaching the steel. A fire rating requires a specified tested system.

Reusable exam procedure and mistakes

  1. Trace the slab arrows and count reactions before doing arithmetic.
  2. Use each member’s exact table row. Class 2 is not Class 1, but both allow capped plastic bending.
  3. Never factor an already factored reaction twice; never include beam dead weight in imposed-load deflection.

Independent practice — invented variant

Invented variant: imposed load rises by 20%, with dead load unchanged. What changes?

Hint

Separate permanent and imposed terms before changing a load.

Reveal answer

Multiply imposed-only deflections by 1.2. Rebuild ULS load as 1.4G + 1.6(1.2Q); do not multiply the total ULS action by 1.2. Section capacities and classes stay unchanged.