Steelwork · Exam learning

2014–2019 · Reference answers

2015-05-12 — beam answers

All independent beam subquestions, including the required sketches and restraint variants.

Independent teaching answer, not an official solution or marking scheme. Printed marks are retained. Read the source conditions beside each result.

Read the diagram and choose the checks

Units: 1 kN = 1,000 N; 1 m = 1,000 mm; 1 cm³ = 1,000 mm³; 1 cm⁴ = 10,000 mm⁴. A demand is the load effect; a resistance is what the member can carry. Compare matching units.

The member is 457 × 152 × 52 UB, S355, simply supported over 6 m, with compression-flange restraints at its ends. Read M and V as ultimate design actions; Q is the unfactored imposed load for deflection. Do not factor a given design moment again.

Source: LectureNotes/CON4334-Data File-20260730.pdf · p.9, p.10

Lookup the exact 457 × 152 × 52 UB row. Read dimensions first, properties second. D = overall depth; t = web thickness; T = flange thickness; d = clear web depth. The designation is not an exact dimension.

D=449.8, t=7.6, T=10.9, d=407.6(mm)D=449.8,\ t=7.6,\ T=10.9,\ d=407.6\quad(\mathrm{mm})
b/T=6.99, d/t=53.6, Ix=21370 cm4, Zx=950 cm3, Sx=1096 cm3b/T=6.99,\ d/t=53.6,\ I_x=21370\,\mathrm{cm^4},\ Z_x=950\,\mathrm{cm^3},\ S_x=1096\,\mathrm{cm^3}
ry=31.1 mm,u=0.859,x=43.9r_y=31.1\,\mathrm{mm},\quad u=0.859,\quad x=43.9

Section classification [4 marks]

Source: LectureNotes/CON4334-Data File-20260730.pdf · p.1

S355 design strength depends on the actual flange thickness. Local classification decides whether plastic bending resistance is allowed. In pure bending the web limit is different from uniform compression.

py=355 N/mm2,ϵ=275/355=0.880141p_y=355\,\mathrm{N/mm^2},\quad\epsilon=\sqrt{275/355}=0.880141
b/T=6.99,9ϵ=7.921,10ϵ=8.801,13ϵ=11.442b/T=6.99,\quad9\epsilon=7.921,\quad10\epsilon=8.801,\quad13\epsilon=11.442
d/t=53.6<80ϵ=70.411⟹Class 1d/t=53.6<80\epsilon=70.411\quad\Longrightarrow\quad\mathrm{Class}\ 1

Take the worse flange/web class. Class 1 or 2 permits the capped plastic modulus; Class 3 uses the elastic modulus.

Compact exam answer — key result lines
py=355 N/mm2,ϵ=275/355=0.880141p_y=355\,\mathrm{N/mm^2},\quad\epsilon=\sqrt{275/355}=0.880141
b/T=6.99,9ϵ=7.921,10ϵ=8.801,13ϵ=11.442b/T=6.99,\quad9\epsilon=7.921,\quad10\epsilon=8.801,\quad13\epsilon=11.442
d/t=53.6<80ϵ=70.411⟹Class 1d/t=53.6<80\epsilon=70.411\quad\Longrightarrow\quad\mathrm{Class}\ 1

Take the worse flange/web class. Class 1 or 2 permits the capped plastic modulus; Class 3 uses the elastic modulus.

Shear and section resistance [5 marks]

Source: LectureNotes/CON4334-Data File-20260730.pdf · p.2

The web carries shear. For a rolled UB use Av = Dt, then the course shear resistance pyAv/√3. The 0.6 factor below is the low-shear threshold; it is not the coefficient in the shear-resistance formula.

Av=449.8(7.6)=3418.48 mm2A_v=449.8(7.6)=3418.48\,\mathrm{mm^2}
Vc=pyAv3=355(3418.48)3(1000)=700.649424 kNV_c=\frac{p_yA_v}{\sqrt3}=\frac{355(3418.48)}{\sqrt3(1000)}=700.649424\,\mathrm{kN}
V=80 kN,V/Vc=0.11418,0.6Vc=420.389654 kNV=80\,\mathrm{kN},\quad V/V_c=0.11418,\quad0.6V_c=420.389654\,\mathrm{kN}

PASS

Mc=min⁡(pySx,1.2pyZx)/1000=min⁡(355(1096),1.2(355)(950))/1000=389.08 kN mM_c=\min(p_yS_x,1.2p_yZ_x)/1000=\min(355(1096),1.2(355)(950))/1000=389.08\,\mathrm{kN\,m}
M/Mc=160/389.08=0.411226M/M_c=160/389.08=0.411226

PASS

Even the maximum shear is below 0.6Vc, so the low-shear moment resistance applies throughout.

Compact exam answer — key result lines
Av=449.8(7.6)=3418.48 mm2A_v=449.8(7.6)=3418.48\,\mathrm{mm^2}
Vc=pyAv3=355(3418.48)3(1000)=700.649424 kNV_c=\frac{p_yA_v}{\sqrt3}=\frac{355(3418.48)}{\sqrt3(1000)}=700.649424\,\mathrm{kN}
V=80 kN,V/Vc=0.11418,0.6Vc=420.389654 kNV=80\,\mathrm{kN},\quad V/V_c=0.11418,\quad0.6V_c=420.389654\,\mathrm{kN}
Mc=min⁡(pySx,1.2pyZx)/1000=min⁡(355(1096),1.2(355)(950))/1000=389.08 kN mM_c=\min(p_yS_x,1.2p_yZ_x)/1000=\min(355(1096),1.2(355)(950))/1000=389.08\,\mathrm{kN\,m}
M/Mc=160/389.08=0.411226M/M_c=160/389.08=0.411226

Even the maximum shear is below 0.6Vc, so the low-shear moment resistance applies throughout.

Lateral-torsional buckling [16 marks]

Source: LectureNotes/CON4334-Data File-20260730.pdf · p.3

For this restraint segment, take the absolute moments at its quarter, half and three-quarter points; divide by the largest absolute moment anywhere in the same segment. The stations belong to the segment, not necessarily to the whole beam. Apply the lower bound 0.44.

M2=120,M3=160,M4=120,Mmax=160(kN m)M_2=120,\quad M_3=160,\quad M_4=120,\quad M_{max}=160\quad(\mathrm{kN\,m})
mLT=max⁡[0.44,0.2+0.15∣120∣+0.5∣160∣+0.15∣120∣160]=0.925m_{LT}=\max\left[0.44,0.2+\frac{0.15|120|+0.5|160|+0.15|120|}{160}\right]=0.925

Use the stated normal-loading effective-length branch: LE equals the distance between effective lateral/torsional restraints. A restraint does not create a new vertical support. Class 1/2 gives βW = 1.

λ=LEry=600031.1=192.926045\lambda=\frac{L_E}{r_y}=\frac{6000}{31.1}=192.926045
v=[1+0.05(192.92604543.9)2]−1/4=0.844546v=\left[1+0.05\left(\frac{192.926045}{43.9}\right)^2\right]^{-1/4}=0.844546
λLT=uvλ=0.859(0.844546)(192.926045)=139.961026\lambda_{LT}=uv\lambda=0.859(0.844546)(192.926045)=139.961026
Source: LectureNotes/CON4334-Data File-20260730.pdf · p.5

Table 8.3, py = 355 N/mm² column; bracketing λLT rows 135 and 140. Interpolate in this column only.

pb=85+139.961026−135140−135(80−85)=80.038974 N/mm2p_b=85+\frac{139.961026-135}{140-135}(80-85)=80.038974\,\mathrm{N/mm^2}
Mb=pbSx/1000=80.038974(1096)/1000=87.722716 kN mM_b=p_bS_x/1000=80.038974(1096)/1000=87.722716\,\mathrm{kN\,m}
mLTMmax=0.925(160)=148 kN mm_{LT}M_{max}=0.925(160)=148\,\mathrm{kN\,m}
ηLT=148/87.722716=1.687134\eta_{LT}=148/87.722716=1.687134

FAIL

Compact exam answer — key result lines
λLT=uvλ=0.859(0.844546)(192.926045)=139.961026\lambda_{LT}=uv\lambda=0.859(0.844546)(192.926045)=139.961026
pb=85+139.961026−135140−135(80−85)=80.038974 N/mm2p_b=85+\frac{139.961026-135}{140-135}(80-85)=80.038974\,\mathrm{N/mm^2}
Mb=pbSx/1000=80.038974(1096)/1000=87.722716 kN mM_b=p_bS_x/1000=80.038974(1096)/1000=87.722716\,\mathrm{kN\,m}
mLTMmax=0.925(160)=148 kN mm_{LT}M_{max}=0.925(160)=148\,\mathrm{kN\,m}
ηLT=148/87.722716=1.687134\eta_{LT}=148/87.722716=1.687134

FAIL

Imposed-load deflection [5 marks]

Use imposed load only: 5 kN/m over the whole span. E = 205,000 N/mm². Convert I from cm⁴ to mm⁴ by multiplying by 10,000; use span in mm. 1 kN/m is numerically 1 N/mm.

δ=5qL4384EI=5(5)(6000)4384(205000)(21370)(10000)=1.925996 mm\delta=\frac{5qL^4}{384EI}=\frac{5(5)(6000)^4}{384(205000)(21370)(10000)}=1.925996\,\mathrm{mm}
δlim=L/360=6000/360=16.666667 mm\delta_{lim}=L/360=6000/360=16.666667\,\mathrm{mm}

PASS

Compact exam answer — key result lines
δ=5qL4384EI=5(5)(6000)4384(205000)(21370)(10000)=1.925996 mm\delta=\frac{5qL^4}{384EI}=\frac{5(5)(6000)^4}{384(205000)(21370)(10000)}=1.925996\,\mathrm{mm}
δlim=L/360=6000/360=16.666667 mm\delta_{lim}=L/360=6000/360=16.666667\,\mathrm{mm}

PASS

Reusable procedure and traps

  1. Separate ultimate resistance from imposed-load serviceability. Keep kN/m and mm-based formulas consistent.
  2. Establish the whole-beam reactions first. For each restraint segment use its own length, quarter-point moments and maximum moment.
  3. A high Mc does not prove LTB passes. Check mLT M ≤ Mb as well as the applicable section resistance.
  4. A smaller unrestrained length normally increases Mb, but its moment factor changes too; recalculate rather than scaling the old ratio.

Independent practice — invented variant

Invented variant: add a lateral brace at a quarter-span point without changing vertical supports or loads. Which calculations change?

Hint

Separate the vertical-load model from the lateral-restraint model.

Reveal answer

Reactions, SFD, BMD and vertical-load deflection remain unchanged in this ideal restraint model. Create new LTB segments, then recalculate each LE, quarter-station moments, mLT, λLT, pb and utilisation. The brace needs a stable load path and cannot be treated as a new vertical support.